CWDM Cisco CWDM wavelengths (nm)

Similar documents
Transceiver, Chassis Connectors, and Cable and Adapter Specifications

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Cable and Port Specifications

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Pass Cisco Exam

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

WDM -Transmission V-1.

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

Overview. Highlights. General Specification. Datasheet

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

RXT-1200 Modular Test Platform

VePAL UX400 Universal Test Platform

WDM. Coarse WDM. Nortel's WDM System

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Wavelength Multiplexing. The Target

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Passive WDM Networking

Qualifying Fiber for 10G Deployment

Technical Specifications

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Optical Transport Technologies and Trends

Dual & Single Fiber Compact CWDM Mux Demux

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

OPC1600 MUX WDM OADM SPLITTER

Cisco s CLEC Networkers Power Session

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

Technical Specifications

DWDM Dual Fiber series

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

Long-Haul DWDM RF Fiber Optic Link System

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Exam : : Cisco Optical SONET Exam. Title. Ver :

WaveSmart Wave Division Multiplexing (WDM)

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

Optical Passives (ISP)

Prisma DWDM Passives. Features. Optical Passive Components

XSD Single Fiber series DWDM passive optical components

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

Pluggable Transceivers

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

Wavelength-Enhanced Passive Optical Networks with Extended Reach

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Further considerations on objectives for PHYs running over point-to-point DWDM systems

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

PR-12-B-M. 12 GHz PhotoReceiver, Module. Features. Applications. Functional Diagram

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Cisco Prisma Optical Passive Components

Why Using Fiber for transmission

GT Channel Ultra Compact CWDM Mux & DeMux

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000

Digital Return System

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

Cisco ONS Erbium Doped Fiber Amplifier

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

Dr. Monir Hossen ECE, KUET

4 Gigabit CWDM SFP CWDM SFP Transceiver RoHS Compliant Specification: F416S174XX-D

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

QSFP-40G-LR4-S-LEG. 40Gbase QSFP+ Transceiver

Digital Return System

DWDM 101 BRKOPT Rodger Nutt High-End Routing and Optical BU Technical Leader

Module 19 : WDM Components

CM /100/1000BASE-T

LEAD Fiber Optics PRODUCT CATALOGUE

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

WDM in backbone. Péter Barta Alcatel-Lucent

Nortel Networks OPTera Long Haul 1600 Optical Line System. 1600G Amplifier Optical Layer Applications Guide

Technical Specifications

Pluggable Transceiver Modules

OC-48 SR-1 / STM I16.1 Long wavelength SFP Transceiver RoHS, SFF-8472 Compliant Specification: F414S17413-D

2/1x Fiber Channel / Gigabit Ethernet 850 nm SX SFP Transceiver RoHS, SFF-8472 Compliant Specification: MOD-MGSX550-D

Multi-Rate up to 2.7G 18 CH CWDM SFP Transceiver RoHS, SFF-8472 Compliant Specification: F419S174XX-D

AA C 1000BASE-CWDM, Small Form-factor Pluggable (SFP), 1.25Gb/s data rate, 1590nm wavelength, 70Km reach

User Manual. Installation Transmit Receive Module SFP/XFP

Optinex. Alcatel 1686 WM. 32 Channels DWDM System (Regional & Metro)

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA

Transcription:

Cisco Enhanced Wavelength Division Multiplexing Product Line The Cisco enhanced wavelength-division multiplexing (EWDM) product line allows users to scale the speed and capacity of the services offered in a coarse wavelength-division multiplexing (CWDM) network by offering the ability to insert up to 8 dense wavelengthdivision multiplexing (DWDM) wavelengths to the existing 8-wavelength CWDM channel plan. Product Overview The Cisco EWDM product line provides the ability to overlay up to 8 DWDM wavelengths with the 8 CWDM channels (1470, 1490, 1510, 1530, 1550, 1570, 1590, and 1610 nm). The principle is very simple, yet it is a unique approach in that the 8 DWDM wavelengths are inserted in between CWDM channels. EWDM allows 5 DWDM channels to be multiplexed between the 1530-nm and 1550-nm CWDM wavelengths and 3 DWDM channels between the 1550-nm and 1570-nm CWDM wavelengths. A total of 8 CWDM plus 8 DWDM wavelengths can be supported on the same fiber infrastructure (See Figure 1). Figure 1. Cisco EWDM Concept DWDM 1530.33 1560.61 Cisco Metro DWDM wavelength (nm) 1470 1490 1510 1530 1550 1570 1590 1610 CWDM Cisco CWDM wavelengths (nm) The Cisco EWDM product line is composed of three passive units and an optical amplifier designed for EWDM applications (Figure 2). The three passive units support 8 DWDM channels (EWDM-MUX8=), 4 DWDM channels (EWDM-OADM-4=), and 2 DWDM channels (EWDM-OADM- 2=), giving customers the flexibility to add 8, 4, or 2 DWDM channels to a CWDM network. The channel plan for the EWDM channels is depicted in Figure 3. Since CWDM passive series filters tolerate for a drift of as much as +/-6 nm around the CWDM center wavelength, the 8 DWDM channels are selected such that they do not interfere with the CWDM spectral range. All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 9

Figure 2. EWDM Passive Units Front Panel EWDM-MUX8= (8-channels MUX/DEMUX) EWDM-OADM4= (4-channels OADM) EWDM-OADM2= (2-channels OADM) Figure 3. Cisco EWDM Channel Plan Channel ID Wavelength (nm) EWDM- OADM4= EWDM- MUX8= EWDM- OADM2= 1 1538.98 2 1539.77 3 1540.56 4 1542.14 5 1542.94 6 1558.98 7 1559.79 8 1560.61 1470 1490 1510 1530 1550 1570 1590 1610 1 2 3 4 5 6 7 8 The optical amplifier (EWDM-OA=) is an Erbium Doped Fiber Amplifier (EDFA) designed to boost 10-Gbps wavelengths enough to compensate for their lower power budget compared to CWDM 1/2-Gbps transceivers. Cisco EWDM is designed with the goal to support 10-Gbps upgrades of CWDM networks, and the optical amplifier enables users to deploy 10-Gbps DWDM optics along with lower speed signals without sacrificing the total network reach. Note that the optical amplifier works in conjunction with the passive units to boost the power of only the DWDM wavelengths. (See Figure 4.) All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 2 of 12

Figure 4. EWDM Optical Amplifier EWDM-OA= Each EWDM component is compatible with the CWDM-CHASSIS-2=, the metal enclosure used for all other Cisco CWDM products. Benefits of Cisco EWDM The approach of Cisco EWDM at mixing CWDM and DWDM signals as well as the introduction of a custom designed amplifier yields the following benefits to end users: EWDM is built from the start with 10 Gbps in mind: customers can use DWDM technology to scale the speed of the services supported in a CWDM network. Customers can grow existing CWDM infrastructures to 16 total wavelengths. Adding DWDM channels does not sacrifice any of the 8 CWDM wavelengths. While upgrading to 10 Gbps, customers do not have to sacrifice the reach of their networks because of the reduced performance of 10-Gbps optics. The optical amplifier, designed for plug-and-play operations, will boost the power of 10-Gbps channels to match to total power budget available on CWDM lower speed services. Applications EWDM can be used to retrofit or expand a CWDM network with 10 Gigabit Ethernet capabilities while protecting 100 percent of the investment in the CWDM infrastructure. The EWDM components in the sample point-to-point configuration in Figure 5 are designed to interoperate transparently with the existing CWDM infrastructure to scale the total number of wavelengths to 16, with potentially up to 8 10 Gigabit Ethernet channels. Figure 5. Example Deployment Scenario (West-to-East Direction Only Shown) 1-5 6-8 TX direction: 8 CWDM + 8 DWDM CWDM-MUX8A= T R CWDM-MUX8A= T R 1-5 6-8 T R AMP UPG EWDM-MUX8= UPG T R AMP UPG EWDM-MUX8= UPG EWDM-OA= (Only if needed) All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 3 of 12

Figure 5 shows a configuration with 8 CWDM and 8 DWDM channels. Going west to east, this is how an EWDM configuration is deployed: 1. The CWDM NETWORK TX port, carrying the 8 CWDM wavelengths, is connected to the CWDM-UPG RX port of the EWDM unit. (The CWDM wavelengths are now ready to be multiplexed together with the DWDM wavelengths.) 2. 2. At the same time, the EWDM passive device receives from its DWDM client ports the signals from 10 Gigabit Ethernet transceivers, multiplexes them together, and routes them out of the AMP IN port. a. If the overall loss experienced by the 10 Gigabit Ethernet wavelengths can be accommodated within the power budget of the 10 Gigabit Ethernet DWDM transceiver (for example, a DWDM Xenpak has 20 db of power budget after ~80 km, taking into account dispersion penalties), simply use the single-mode simplex LC patch cord provided with the EWDM device to connect the AMP IN to the AMP OUT. This way the DWDM wavelengths are fed back into the EWDM device ready to be multiplexed together with the CWDM signals. b. If the 10 Gigabit Ethernet channels require extra power to match the power budget of the CWDM GBIC/SFP devices, then the DWDM wavelengths out of the AMP IN port have to be injected into the IN port of the EWDM-OA=. The OUT port of the amplifier then feeds back the amplified signals into the AMP OUT port of the EWDM passive device. This way the DWDM wavelengths are fed back into the EWDM device ready to be multiplexed together with the CWDM signals. 3. At this stage the EWDM unit performs the multiplexing operation of CWDM and DWDM wavelengths. The aggregate CWDM plus DWDM signal is then sent out of the EWDM NETWORK TX port connected to the metro fiber. 4. At the receiving end, the metro fiber is connected to the EWDM NETWORK RX port, which receives all the CWDM and DWDM wavelengths. The DWDM wavelengths are demultiplexed and routed to the client TX ports connected to the 10 Gigabit Ethernet transceivers (hosted in a Cisco Catalyst line card, for example). The CWDM wavelengths pass through the EWDM device transparently and are directed out of the CWDM-UPG TX port. 5. The CWDM-UPG TX port is connected to the NETWORK RX port of the CWDM units in Figure 5. The CWDM device demultiplexes the CWDM wavelengths and directs them to the receivers of the CWDM transceivers (hosted in a Cisco Catalyst or MDS line card, for example). Other Possible Applications In addition to mixing up to 8 DWDM channels over a CWDM network, the EWDM solution can be used in other possible applications: point-to-point DWDM, point-to-point amplified DWDM, small optical rings, and CWDM over DWDM. Point-to-point DWDM link Figure 6 shows an unamplified DWDM link with the 8-channel EWDM filters. Similar topology is supported with the 2-channel and 4-channel filters. Figure 6. Unamplified 8-Channel DWDM Link (West to East Only Shown) All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 4 of 12

Figure 7 shows an amplified DWDM link with the 8-channel EWDM filters. Similar topology is supported with the 2-channel and 4-channel filters. Figure 7. Amplified 8-Channel DWDM Link (West to East Only Shown) In unamplified point-to-point links, 1-Gigabit DWDM traffic can typically achieve distances around 80km, and 10-Gigabit DWDM traffic can typically reach 60km. In amplified point-to-point links, 1- Gigabit DWDM traffic can typically achieve distances between 100 and 120km, and 10-Gigabit DWDM traffic can typically reach 80km (limited by chromatic dispersion). Small all-optical hubs and rings With EWDM filters it is possible to design small optical rings or hub and spoke topologies. This is made possible by reinserting a dropped channel into a separate filter module. Figures 8 and 9 show, respectively, a linear and a ring topology. Note that the distances in such designs will be limited by the insertion losses introduced when channels are dropped and inserted back into the network. Figure 8. 2-Channel Hub and Spoke Topology (West to East Only Shown) All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 5 of 12

Figure 9. 2-Channel Protected Ring Topology (Drop Path Shown in Each Direction) CWDM over DWDM With an appropriate choice of CWDM wavelengths, it is possible to add and drop CWDM channels at an intermediate site between two EWDM filters. Figure 10 shows a possible solution with a 1470-nm CWDM channel. Figure 10. CWDM Channel Dropped Between 2 EWDM Filters (Drop Path Shown in Each Direction) EWDM Passive Unit Product Specifications Figure 11 shows the EWDM passive unit front panel layout. Figure 11. EWDM Passive Unit Front Panel Layout The NETWORK port sends and receives the CWDM+DWDM signals to and from the network.. The AMP port send the composite DWDM signal to the amplifier and receives it back amplified. Client DWDM signal ports. LC connectors The CWDM-UPG port sends and receives the CWDM wavelengths to the CWDM units (sitting upstream) All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 6 of 12

Table 1 shows the EWDM-MUX8 passive unit optical specifications. Table 1. EWDM-MUX8 Passive Unit Optical Specifications Parameter Path Min Max Unit Operating Band 1460-1620 Nm Channel Spacing 100 GHz DWDM Channel 0.5 db Bandwidth -0.12 +0.12 Nm DWDM Channel 1 to 8 Insertion Loss Mux DWDM (channel) 3.5 db Demux DWDM (channel) 2.5 Mux CWDM (band) 1 Demux CWDM (band) 1.5 Combined Mux Demux DWDM (same channel) 4.7 Isolation Pass Port Isolation (In band Isolation) 15 mux db Adjacent channels Isolation (DWDM Channels over DWDM or CWDM channels) 30 demux Return Loss 45 db Directivity 50 db PDL All Paths 0.2 db PMD All Paths 0.2 ps Optical Loss Uniformity Max Optical Input Power 1.5 db 300 mw Table 2 shows the EWDM-OADM4 passive unit optical specifications. Table 2. EWDM-OADM4 Passive Unit Optical Specifications Parameter Path Min Max Unit Operating Band 1460-1620 Nm Channel Spacing 100 GHz DWDM Channel 0.5 db Bandwidth -0.12 +0.12 nm DWDM Channel 2,3,4,5 Insertion Loss Mux DWDM (channel) 3.5 db Demux DWDM (channel) 2.5 Mux CWDM (band) 1 Demux CWDM (band) 1.5 Combined Mux Demux DWDM (same channel) 3.7 Isolation Pass Port Isolation (In band Isolation) 15 mux 30 demux db Adjacent channels Isolation (DWDM Channels over DWDM or CWDM channels) 30 All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 7 of 12

Return Loss 45 db Directivity 50 db PDL All Paths 0.2 db PMD All Paths 0.2 ps Optical Loss Uniformity Max Optical Input Power 1 db 300 mw Table 3 shows the EWDM-OADM2 passive unit optical specifications. Table 3. EWDM-OADM2 Passive Unit Optical Specifications Parameter Path Min Max Unit Operating Band 1460-1620 Nm Channel Spacing 100 GHz DWDM Channel 0.5 db Bandwidth -0.12 +0.12 nm DWDM Channel 7 and 8 Insertion Loss Mux DWDM (channel) 2 db Demux DWDM (channel) 2 Mux CWDM (band) 1 Demux CWDM (band) 1 Combined Mux Demux DWDM (same channel) 3.1 Isolation Pass Port Isolation (In band Isolation) 15 mux 30 demux db Adjacent channels Isolation (DWDM Channels over DWDM or CWDM channels) 30 Return Loss 45 db Directivity 50 db PDL All Paths 0.2 db PMD All Paths 0.2 ps Optical Loss Uniformity Max Optical Input Power 1 db 300 mw All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 8 of 12

Table 4 shows a summary of the total add/drop loss suffered per channel with the EWDM passive units Table 4. Model EWDM Passive Unit Add/Drop losses Maximum Insertion Loss (db) Add+Drop DWDM Add CWDM Drop CWDM EWDM-MUX8= 4.7 1 1 1.5 EWDM-OADM4= 3.7 2 1 1 EWDM-OADM2= 3.1 3 1 1 Table 5 shows the EWDM passive unit environmental conditions. Table 5. Parameter EWDM Passive Unit Environmental Conditions Min/Max Value Operating Temperature -5 ~ 55ºC Storage Temperature -40 to 85ºC Operating Humidity 5 to 95%RH EWDM Optical Amplifier Unit Product Specifications Figure 12 illustrates the EWDM amplifier front panel layout. Figure 12. EWDM Amplifier Front Panel Layout The front panel includes: 3 LEDs to report the status of the device (Table 6) A hardware reset button (next to the alarm LED) (Table 7) An RS-232 interface with RJ45 connector (Table 8) An AC power plug (Table 9) The optical input and output ports based on LC connectors (Table 10) 1 If the link is terminated with another EWDM-MUX8= device. If a different EWDM device terminates the link, the DWDM ADD insertion loss is 3.5 db, and the DWDM DROP insertion loss is 2.5 db. 2 If the link is terminated with another EWDM-OADM4= device. If a different EWDM device terminates the link, the DWDM ADD insertion loss is 2.5 db, and the DWDM DROP insertion loss is 2.5 db. 3 If the link is terminated with another EWDM-OADM2= device. If a different EWDM device terminates the link, the DWDM ADD insertion loss is 2 db, and the DWDM DROP insertion loss is 2 db. All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 9 of 12

Table 6. EWDM Front Panel LED State Functionality Possible State Comment Power Input power alarm Alarm LED Ok Starting up Failure In range Out of range Normal condition Minor problem Severe problem Green Green Red Green Red Green Orange Red Table 7. EWDM Amplifier Unit Optical Specifications Parameter Min Typ Max Unit Total operating signal wavelength range 1538.2 1561.4 nm Total output power 17.5 dbm Total input power -4.5 9.5 dbm Per channel input power -4.5 2.5 dbm Single channel output power 3.5 12 dbm Gain 7.5 8 8.5 db Gain flatness -0.5 +0.5 db Noise figure 10 db Return loss 40 db PDG -0.25 +0.25 db PMD 0.3 ps Table 8. RS-232 Requirements Parameter Value Data bits 8 Parity No parity Stop bits 1 Speed 9600 Table 9. Console Port Signaling and Cabling Item Comment Min Type Max Unit External voltage supply 85 110 or 220 265 V Power consumption 10 W Cold startup time: Electrical 5 S Maximum inrush power dissipation Max 3 minutes 40 W Maximum inrush power current @ 100 VAC, @ 25C 15 A @ 200 VAC, @ 25C 30 A All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 10 of 12

Table 10. Console Port Signaling and Cabling Console Port (DTE) RJ-45-to-RJ-45 Rollover Cable Console Device Signal RJ-45 Pin RJ-45 Pin Signal RTS1 1 8 CTS2 No connection 2 7 DSR TxD3 3 6 RxD4 GND5 4 5 GND GND 5 4 GND RxD 6 3 TxD No connection 7 2 DTR6 CTS 8 1 RTS Ordering Information To place an order, visit the Cisco Ordering Homepage. Table 11 lists ordering information for the Cisco EWDM products. Table 11. Ordering Information Product Name Cisco EWDM MUX/DEMUX 8 wavelengths Cisco EWDM MUX/DEMUX and OADM 4 wavelengths Cisco EWDM MUX/DEMUX and OADM 2 wavelengths Cisco EWDM optical amplifier Part Number EWDM-MUX8= EWDM-OADM4= EWDM-OADM2= EWDM-OA= Service and Support Cisco offers a wide range of services programs to accelerate customer success. These innovative services programs are delivered through a unique combination of people, processes, tools, and partners, resulting in high levels of customer satisfaction. Cisco Services help you to protect your network investment, optimize network operations, and prepare the network for new applications to extend network intelligence and the power of your business. For more information about Cisco Services, see Cisco Technical Support Services or Cisco Advanced Services. For More Information For more information about Cisco WDM products, visit http://www.cisco.com/en/us/products/ps6575/index.html or contact your local account representative. All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 11 of 12

Printed in USA C78-422619-01 04/09 All contents are Copyright 1992 2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 12 of 12