GSP303D 3-Axis Digital Magnetic Field Transmitter

Similar documents
Handheld Gaussmeter Gaussmeter

Low Cost Three-Axis Fluxgate Sensor GFS-E. Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz

F3A Magnetic Field Transducers

H3A Magnetic Field Transducer

SSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

Picture 1 PC & USB Connection

Analysis of static and time-variable magnetic fields

F1A Magnetic Field Transducers

I1A Magnetic Field Transducers

SDM3045X Digital Multimeter. DataSheet

MGA103 Single Axis MEMS Gyro with Triaxial Accelerometer

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

I1A Magnetic Field Transducers Very Low Noise & Offset Magnetic Transducers with Integrated 1-axis (Y) Hall Probe DESCRIPTION: The I1A denotes a range

MG100 Single Axis MEMS Gyro

IMU60 Inertial Measurement Unit

thin and flexible probes factory calibration certificate with traceability High precision Analog output: DC 35 khz (depending on probe type)

Moving Test - MT3000

SDM3045X Digital Multimeter. DataSheet

EMI Pre-Compliance Testing Solution

Electromagnetic Field Measurement System

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Narda EMF drive test solution

Spectrum Analyzers 2680 Series Features & benefits

3-Axis Magnetometer on a Chip. Philip Keller

Magnetic Field Compensation System MR-3

High Stability Voltage Source

Model D875 Mini Tuff Tilt Digital Tiltmeter

EMC-scanner. HRE-series. See it before you CE it!

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

LUXONDES. See the electromagnetic waves. Product 2018 / 19

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276

Additel 875 Series Dry Well Calibrators

F3A Magnetic Field Transducers High Spatial Resolution Magnetic Transducers with Fully Integrated 1-, 2-, 3-axis Hall Probe DESCRIPTION: KEY FEATURES:

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

DSA700 Series Spectrum Analyzer

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

MAGNETOSCAN MAGNETIC MEASURING SCANNER

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

SCXI 8-Channel Isolated Analog Input Modules

Selective and broadband low frequency field analysis

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

Principles of operation 5

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Application Note PE003

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Technical Information

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

3D-magnetic field probes AS-U3D GEO-X for ±200 µt

Differential charge amplifier

Integrated Diode Laser System DioPower

Selective and broadband high frequency field analysis

3DM-GX4-45 LORD DATASHEET. GPS-Aided Inertial Navigation System (GPS/INS) Product Highlights. Features and Benefits. Applications

Tap Changer Analyzer & Winding Ohmmeter RMO60TT


RS Pro ARBITRARY/FUNCTION WAVEFORM GENERATOR SDG800 SERIES

ULTRASTAB I U Precision

Differential Charge Amplifier

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

B-Field Scanner. BENEFITS Easy to use Fits to a wide range of voice coil gaps Fully supported by Klippel RnD System Dedicated measurement software

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

High-precision process calibrator Model CED7000

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

NI 6731/6733 Specifications

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Spectrum Analyzer. Distribution in the UK & Ireland

Grad-13. Digital Three-Axis Gradiometer.

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Fluke 5820A Oscilloscope Calibrator Specifications

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

ME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price.

Torque Station Pro TS-7700 System

Product Features Benefits The IMC Group Ltd.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Specification. Scanning Laser Range Finder C /6. Date:

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Exposure Level Tester ELT-400

B850 Boiler House Energy Monitor

Specification. Scanning Laser Range Finder UTM-30LX/LN C /6. Date: Symbol Amendment Details Amendment Date Amended by Number

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Chapter 6 Specifications

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

CALYS 150. Advanced documenting multifunction calibrator thermometer

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

XC4e PWM Digital Drive

Analyzer Twin. k +49 (0) / (0) / General Agent Germany:

CALYS 150. Advanced documenting multifunction calibrator thermometer

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Features. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output

REMAGRAPH C for computer controlled measurement of the hysteresis curves of soft magnetic materials.

Transcription:

Digital Handheld Magnetic Transmitter Transmitter Field Transmitter GSP303D 3-Axis Digital Magnetic Field Transmitter Digital Output (RS485) Accuracy Based on Reading (Not Range) Wide Supply Power: 5 to 36VDC Description: With industry standard design, 3-Axis Digital Magnetic Field Transmitter GSP303D, could measure magnetic fields and output digital signals (Bx, By, Bz) of a magnetic flux density via RS485, which is easy to make into an integrated system, and able to meet the industrial production of a variety of complex environments and requirements. Typical applications are: Magnetic Field Map (magnetic field mapping & scanning system), incoming test in production line, quality control and monitoring system (generator, motor), distribution test of pulsed magnetic field and gradient magnetic field, multi-point synchronous testing of space magnetic field, material surface magnetic field detection and so on. 3-Axis Digital Magnetic Field Transmitter GSP303D s accuracy is based on reading, not the measurement range. Transmitter GSP303D s measurement range can be chosen, such as 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized, with the reading-based accuracy of 1% (0.5% or 0.1% also can be chosen), and frequency response from DC to 1KHz or 50KHz. Transmitter GSP303D s power supply is very unique, as 5VDC- 36VDC wide power supply. Lack of power supply or power supply equipment failure situation will lead to voltage instability, and will be likely to cause instability in the test data or hardware damage. Wide voltage power supply effectively ensures that GSP303D will work stably and has better reliability when power supply voltage is unstable. There is a unique feature for 3-axis probe of Transmitter GSP303: With the MEMS manufacturing technology, 3-axis probe sensor provides very high spatial resolution (0.1*0.1*0.1mm 3 ) and high angular accuracy (orthogonality error < 0.05 ), and the thickness of 3-axis probe is 2mm, and it s suitable for institutes, universities and enterprises. Transmitter GSP303D s typical probes adopt the instrument-grade GaAs Hall Sensor which >>1

Digital Magnetic Field Transmitter owns a temperature coefficient of 500ppm/. However, Temperature sensor-contained probes (probes with built-in temperature sensor) have the function of temperature compensation, so temperature sensor-contained probes are strongly recommended for better precision and stability when the temperature changes and it s suitable for institutes, universities and enterprises. Transmitter GSP303D can be equipped with different kinds of 3-Axis Probes: Standard 3-Axis Probe and Temperature sensor-contained 3-Axis Probe. Also according to the special needs of customers, it s possible to customize probe s range, shape, size and cable length. Meanwhile, Transmitter GSP303D has passed the CE certification and EMC (Electromagnetic Compatibility) test. Features Manufactured by industry standards Instrument-grade GaAs Hall Sensor Digital outputs (RS485: Bx, By, Bz), easy to integrate To form a multi-point magnetic field synchronization detection system Power supply voltage 5VDC- 36VDC Through EMC test Certificated by CE standard Equipped with Smart PC Software Accuracy of 1%, 0.5% or 0.1% Range of 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized Frequency response: DC to 1KHz or 50KHz High orthogonality accuracy (< 0.05 ) High spatial resolution(0.1*0.1*0.1mm 3 ) Temperature sensor-contained Probe: Temperature compensation Probe thickness: only 2mm Probe can be customized Smart PC Software Interface 2<<

Handheld Transmitter Digital Magnetic Field Transmitter GSP303D Transmitter Specification: MODEL GSP303D Measurement Specification Accuracy(DC) Range Best Resolution Frequency Response ±1% of reading ± 0.1% of range ±0.5% of reading ± 0.08% of range ±0.1% of reading ± 0.05% of range 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized 0.01G (1μT) DC - 1KHz or DC- 50KHz Temperature Coefficient <±500ppm/ <±100ppm/ [Typical Probe] [Temperature Sensor-contained Probe] Zero Drift Long-term Instability of Sensitivity RS485 Interface Probe <±0.05% of Full Scale within 168 hours <0.1% over 1 year Cable: MAX. 500m; Data update rate: MAX. 100 Sample/s Probes SMART PC Software Standard 3-Axis Probe and Temp. sensor-contained 3-Axis Probe Function 1, Automatically record and display trend graph; 2, Display magnetic flux density, maximum and minimum in real time; 3, Choose DC Measurement Mode or AC Measurement Mode. Transmitter Specification Operating Temperature Storage Temperature Power Consumption Power Supply Dimension Weight Certification -20 C to +75 C -20 C to +80 C (MAX)1.2W 5VDC- 36VDC 165 mm W 95 mm H 40 mm D 300g CE Certification, EMC Certification >>3

Digital Magnetic Field Transmitter GSP303D Transmitter s Connection and Terminals Description Digital Signal Output (RS485: Bx, By, Bz) Power Supply (5VDC- 36VDC) 1, Transmitter Terminals Description Terminals Description 485_A 485_B Digital Signal Output (RS485: Bx, By, Bz) [Cable Length: max. 500m] V+ DC Power Supply V- (5VDC- 36VDC) 2, Probe s Dimension Probe Specification Probe Type and Specification Probe Dimension Probe cable length The position of sensor center See in Description Of Transmitter Type Selection 20 x 4.5 x 2mm See in Description Of Transmitter Type Selection D=3mm ± 0.2mm 4<<

Handheld Transmitter Digital Magnetic Field Transmitter Description Of Transmitter Type Selection Description Option Example Output Type of Transmitter GSP303 Range Accuracy (Based on reading) Probe Cable Length Temp. compensation (Temperature sensor-contained Probe) Note: GSP303A: Analog Output (±10V) GSP303D: Digital Output (RS485) 300G 1KG 3KG 10KG 30KG 100KG 300KG OR to be customized 1% 0.5% 0.1% 2m 5m 10m 20m 30m OR to be customized No Code: None TC: Yes GSP303D 30KG 1% 2m TC 1, GSP303D-30KG-1%-2m is the standard model of 3-Axis magnetic field transmitter GSP303D; users should select output type, range, accuracy, frequency bandwidth, probe cable length and sensitivity to DC magnetic field before an order; if customers have other special requirements (such as pulse magnetic field, high-speed magnetic field measurement sampling, high temperature or low temperature measurement environment, underwater magnetic field monitoring measurements, etc.), please contact Coliy. 2, The digital output accuracy is based on reading, and not affected by Range; 3, Frequency Response: DC- 1KHz or DC- 50KHz can be chosen; 4, Temperature sensor contained Probe, has the function of temperature compensation, and the temperature coefficient is <±100ppm/ ; 5, Each 3-axis probe s fully calibrated measurement range: ±20KG (±2T); 6, Probe s default operating temperature: -20 to +75 ; 7, 3-Axis Magnetic Field Transmitter GSP303 has two models, one is GSP303A with analog output (XYZ, ±10V), and the other is GSP303D with digital outputs (RS485: Bx, By, Bz). >>5

Digital Magnetic Field Transmitter Optional Accessories PS2012 ZC10 Model Descriptions Power Adapter; Input: 100VDC- 230VDC; Output: ±12VDC, 5A Zero chamber, provides up to 80 db attenuation in fields up to 500 G and can be used with standard probes. Internal dimension of the Chamber: diameter 6.8mm x 44.5mm S485USB RS485 to USB adapter The most popular Package Package Product No. GSP303D01: Transmitter GSP303D-30KG-1%-2m + Zero Chamber ZC10 Precision Description Of COLIY Transmitter When using Transmitter to measure magnetic field in the environment that ambient temperature changes obviously, it s recommended to use temperature sensor- contained probe with the Transmitter. Temperature sensor-contained probe has the function of temperature compensation for better precision and stability when the temperature changes. When the magnetic field is within 30KG (3T), users could directly choose the accuracy grade according to users desired accuracy. For example, users use transmitter, whose accuracy is 1%, to detect a magnetic field at about 1000G. Then transmitter s reading range is 1000G ± 1000G * 1%, instead of 1000G ± 30000G * 1%, for COLIY transmitter s accuracy is based on reading rather than transmitter s range. (30000G is the transmitter s range, 30000G= 3T) Due to continuous process improvement, specifications subject to change without notice. Document trademarks and product names are trademarks of Coliy Technology GmbH. Amendment 1,Publishing:NSF-English-01-06 6<<