Photoresist Absorbance and Bleaching Laboratory

Similar documents
DOE Project: Resist Characterization

THE USE OF A CONTRAST ENHANCEMENT LAYER TO EXTEND THE PRACTICAL RESOLUTION LIMITS OF OPTICAL LITHOGRAPHIC SYSTEMS

Part 5-1: Lithography

i- Line Photoresist Development: Replacement Evaluation of OiR

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Micro/Nanolithography

Photolithography II ( Part 2 )

Contrast Enhancement Materials CEM 365iS

PHGN/CHEN/MLGN 435/535: Interdisciplinary Silicon Processing Laboratory. Simple Si solar Cell!

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Contrast Enhancement Materials CEM 365HR

Major Fabrication Steps in MOS Process Flow

NAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships

Heidelberg µpg 101 Laser Writer

ADVANCED MASK MAKING AT RIT. David P. Kanen 5th Year Microelectronic Engineer Student Rochester Institute of Technology ABSTRACT

MicroLab 500-series Getting Started

MeRck. AZ nlof technical datasheet. Negative Tone Photoresist for Single Layer Lift-Off APPLICATION TYPICAL PROCESS. SPIN CURVE (150MM Silicon)

Semiconductor Manufacturing Technology. Semiconductor Manufacturing Technology. Photolithography: Resist Development and Advanced Lithography

UV-Vis-NIR Spectrophotometer Quick Start Guide

+ Preferred material for tool O Acceptable material for tool X Unacceptable material for tool

Process Optimization

Clean Room Technology Optical Lithography. Lithography I. takenfrombdhuey

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Synthesis of projection lithography for low k1 via interferometry

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

MeRck. nlof 2000 Series. technical datasheet. Negative Tone Photoresists for Single Layer Lift-Off APPLICATION TYPICAL PROCESS

Lecture 7. Lithography and Pattern Transfer. Reading: Chapter 7

Photoelectric Effect Apparatus

Module 11: Photolithography. Lecture11: Photolithography - I

Outline. 1 Introduction. 2 Basic IC fabrication processes. 3 Fabrication techniques for MEMS. 4 Applications. 5 Mechanics issues on MEMS MDL NTHU

Development of a LFLE Double Pattern Process for TE Mode Photonic Devices. Mycahya Eggleston Advisor: Dr. Stephen Preble

Device Fabrication: Photolithography

UV LED ILLUMINATION STEPPER OFFERS HIGH PERFORMANCE AND LOW COST OF OWNERSHIP

Key Photolithographic Outputs

Photolithography Technology and Application

Optical Requirements

BI-LAYER DEEP UV RESIST SYSTEM. Mark A. Boehm 5th Year Microelectronic Engineering Student Rochester Institute of Technology ABSTRACT

KMPR 1010 Process for Glass Wafers

Photolithography I ( Part 1 )

Section 2: Lithography. Jaeger Chapter 2. EE143 Ali Javey Slide 5-1

ASML Job Set-up procedure for Standard Jobs 4 wafers:

MICROCHIP MANUFACTURING by S. Wolf

Lecture 13 Basic Photolithography

UFNF YES Image Reversal & HMDS Oven Revision 6.0 1/22/2014 Page 1 of 5. YES Image Reversal and HMDS Oven SOP

EE 143 Microfabrication Technology Fall 2014

University of Wisconsin Chemistry 524 Spectroscopic Components *

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. EE143 Ali Javey Slide 5-1

VS7550 VUV/UV Mini Spectrograph Operating Manual

Microlens formation using heavily dyed photoresist in a single step

Photoelectric effect

Microlithography. Dale E. Ewbank ul ppt. Microlithography Dale E. Ewbank page 1

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

RENISHAW INVIA RAMAN SPECTROMETER

Handbook Ref No. IH001/Issue D File Ref: PR203-v5D.doc

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. The lithographic process

Automated Double Aperture Accessory

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

Using the Normalized Image Log-Slope, part 2

Bandpass Interference Filters

UV-dose indicator formulations as paint-onphotodetectors: way to optimize the UV curing process

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Zeiss 780 Training Notes

Feature-level Compensation & Control

Systems & Accessories

Optolith 2D Lithography Simulator

Ph 3455 The Franck-Hertz Experiment

MICROBUMP LITHOGRAPHY FOR 3D STACKING APPLICATIONS

Lithographic Process Evaluation by CD-SEM

StarBright XLT Optical Coatings

Operating Instructions Pocket Pictor For use with Pocket Pc s

Power Sensors Introduction

Ph 3455 The Photoelectric Effect

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

CHAPTER 2 Principle and Design

AP Chemistry Cell Phone Spectroscopy Lab Adopted from Alexander Scheeline Department of Chemistry University of Illinois at Urbana-Champaign

Organic Antireflective Coatings for Photomask Fabrication using Optical Pattern Generators

The operation manual of spotlight 300 IR microscope

EE143 Fall 2016 Microfabrication Technologies. Lecture 3: Lithography Reading: Jaeger, Chap. 2

Chapter 6. Photolithography

CHAPTER 7. Components of Optical Instruments

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL. rev

Table 8 Overview light sources

Surface Topography and Alignment Effects in UV-Modified Polyimide Films with Micron Size Patterns

ScanArray Overview. Principle of Operation. Instrument Components

MICRO AND NANOPROCESSING TECHNOLOGIES

Chapter 6 Photolithography

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Measuring optical filters

Quick Start MMRC Nicolet 6700 Revised 10/24/2018

Operating Manual. Model 721N. Visible Spectrophotometer

Dr. Dirk Meyners Prof. Wagner. Wagner / Meyners Micro / Nanosystems Technology

Experiment 2B Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART B. MOLECULAR FLUORESCENCE SPECTROSCOPY

Critical Dimension Enhancement of DUV Photolithography on the ASML 5500/300. Francesca Calderon Miramonte High School August 13th, 2015

William Reiniach 5th Year Microelectronic Engineering Student Rochester Institute of Technology

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

Characterization Microscope Nikon LV150

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

Transcription:

MCEE 505 Lithography Materials and Processes Page 1 of 5 Photoresist Absorbance and Bleaching Laboratory Microelectronic Engineering Rochester Institute of Technology 1. OBJECTIVE The objective of this experiment is to understand and characterize the relationship between absorbance and photosensitivity for photoresist materials. 2. INTRODUCTION Exposure of photoresist involves the absorption of radiation and subsequent photochemical change, generally resulting in a modification of dissolution properties. The absorption characteristics of a photoresist will largely influence its resolution and process capabilities. Resists based only on exponential attenuation of radiation (i.e. with no mechanism for photo-bleaching or chemical amplification) can be limited by a maximum allowable contrast, sidewall angle, and ultimate resolution. This is because of the inherent absorption trade-off required when imaging into a resist film. Both maximum transmission (to reach to the bottom of the resist) and maximum absorption (to achieve highest sensitivity) are desired. There is therefore an optimum resist absorbance value for any resist thickness. The dynamic absorption that exists for the sensitizer for novolac resists occurs as exposure leads to a more transparent photoproduct. This bleaching phenomenon can be described in terms of the Dill absorption parameters A, B, and C [see Optical Lithography - F.H. Dill (1975)]. The A parameter describes the exposure dependent absorption of the resist, the B parameter is the exposure independent absorption, and C describes the rate of absorption change, or bleaching rate. For novolac resists, the C parameter conveniently relates directly to resist sensitivity since photo bleaching corresponds to the conversion of the photoactive compound (PAC) to the photoproduct. The choice for a specific sensitizer compound for mid-uv lithography needs to include evaluation of the unique A, B, and C parameters at the wavelength of exposure. It is generally desirable to have a low exposure independent absorption (B parameter) to achieve maximum exposure efficiency to the bottom of a resist layer. Chemical amplification is another avenue that exists to improve the absorption characteristics of a resist. With quantum efficiencies that are several orders of magnitude higher than what can be achieved for direct photo-modified resists, only a small amount of photon absorption is needed. The down side of such high transparency for resist materials is the increased opportunity for substrate reflection to degrade performance. These effects can be manifested as line width variation over reflective steps (notching) and sidewall standing wave. The reduction of these standing waves is crucial in order to retain CD control. This can be dealt with in either resist exposure or process stages and is ordinarily addressed in both. To reduce standing waves effects during exposure, the reflected contribution must be controlled. This can be accomplished by incorporating a dye into the resist formulation. Dyes such as coumarin or curcumin compounds have been used as additives to novolac resists and are very effective at reducing the reflected exposure contribution in a resist layer at g-line and i-line wavelengths. By adding a dye, the exposure independent absorption is increased. The result will be a decrease in reflection effects and standing wave but also a decrease in the amount of energy transferred toward the bottom of the resist. This will result in a decrease in sidewall angle, resist contrast and sensitivity. Dyed resist for i-line use is therefore usually limited to highly reflective, non- critical layers.

MCEE 505 Lithography Materials and Processes Page 2 of 5 3. MEASUREMENT OF RESIST ABSORPTION This lab will involve the measurement of resist absorption. Two methods will be utilized: 3.1) Spectrophotometric measurement of absorption through wavelength. 3.2) An actinic measurement of absorption and bleaching at lithography wavelengths. 3.1 Spectrophotometry procedure A Perkin Elmer UV/VIS spectrophotometer will be used to measure the unexposed and exposed absorption of photoresist. Before performing the lab, turn on the Perkin Elmer ~30 minutes prior to running anything (green switch near the back). The computer should already be on (if it is not, the computer needs to be turned on before the Perkin Elmer). 1. Obtain a 4" quartz fused silica mask substrate. 2. Clean (with isopropanol) and dehydrate bake the substrate at 100 C for 3 minutes and prime with P-20 primer (80% PGMEA-20%HMDS) @3000RPM, followed by a bake at 100 for 1 min. a. Placing the silica wafer directly on a hot-plate will send it into thermal shock and break it. To avoid this, slowly slide it on to the hot-plate from the side. 3. Coat photoresist at 3000 RPM, and bake at 100 for 3 min. Measure thickness via profilometry, or Nanospec a silicon wafer coated with identical settings. a. Remember to place the coated wafer in an opaque container when traveling outside the yellow light environment. 4. Use the PE Lambda 11 UV-VIS spectrometer to measure transmittance of film from 200-800 nm. Follow the procedures given below to obtain ASCII data for plotting. Calculate and plot the absorbance of the photoresist in units of μm-1. a. Once the tool has initialized, open PECSS (shortcut on the desktop). b. Press Shift-F10 to open the menu, then once the menu shows up at the bottom of the screen, press Enter for Scan. c. Input the desired filename, turn on autosave, and set to measure transmission. When finished, press enter until some options appear at the bottom (Y)es (N)o (A)utocalibrate. d. Run (A) first to record the background spectrum with no substrate. Then run (Y)es for the each sample. The data should automatically be saved as whatever you named the file. e. Hit the escape key and type STOP to exit. f. Data files need to be convert to.dif files. These are ascii delimited text. 5. Flood expose resist sample using GCA6700 stepper at the reticle stage using a dose of 300 mj/cm 2. 6. Repeat transmission measurements from 200-800nm and collect data. 7. Plot absorbance for both exposure cases as well as bleaching effects. z a. Use the Beer-Lambert law T e to derive absorption from the transmission data, where z is the film thickness, and α is the absorption coefficient. b. Extract A, B, and an estimate of C for each case.

MCEE 505 Lithography Materials and Processes Page 3 of 5 3.2 Actinic absorption and A, B, C measurement Measurement of resist absorption parameters can be carried out based on the Dill method [see Characterization of Positive Photoresist - F.H. Dill, W.P.Hornberger, P.S. Hauge, J.M. Shaw (1975)]. These values can then be used as inputs in the simulation programs. In this experiment, glass microscope slides will be used as substrates for the resist film. A photoresist film coated on a transparent substrate is exposed to radiation from a lithography exposure tool (such as the GCA g-line stepper). The radiation transmitted through the resist-substrate is measured as a function of time. The absorption parameters of the resist can be calculated from the dynamic transmission of the film. Parameter A gives information on light absorption due to the PAC. Parameter B gives information on the base absorption of the resist excluding the PAC. Parameter C gives information on the bleaching rate of the photoresist during exposure. The following procedure will be used. 8. Using a multimeter, an amplifier, a database application, an extension cord, an electrical outlet splitter (or another extension cord), and a UV photo-detector; set up an experimental measurement apparatus to collect the radiation transmitted through a resist coated microscope slide. The GCA 6700 stepper will be used as the g-line radiation source, and the i-line hood will be used as the i- line radiation source. a. Plug in the amplifier ahead of time; the gain increases as the device warms. b. Use the photo-detector to measure the irradiance of the tool. c. Attach the photodiode into the back of the amplifier, and mount the sample above it in the optical column if appropriate (you will collect data without a substrate, with an uncoated substrate, and with a coated substrate). d. Reset the GCA s aperture blades to home position with the command RMS followed by AP R and then exit RMS with ~ e. Play with the range and sensitivity so that the output voltage does not peg when the shutter is open. i. Range C, Sensitivity Factor x10-6 has worked in the past. ii. The amplifier should be in Fast D.C. mode. iii. Keep an eye on the output to ensure the gain has not drifted over time. 1. If this occurs and the range or sensitivity factor must be changed, remember to take another set of measurements for calibration. 2. Even if it doesn t peg, the amplification will drift, so take calibration measurements around the same time as when the slides get exposed. f. Using two banana plugs, connect the amplifier s ground and 1000mV Recorder Output ports (found on the backside) into the 1000Vmax and ground inputs on the front of the multimeter. g. Connect the multimeter to the computer with the serial cable.

MCEE 505 Lithography Materials and Processes Page 4 of 5 h. Turn on the multimeter i. The display should briefly read RS-232 1. If not: Shift, menu, right to I/O menu, down to GPIB addr, right to Interface, down, right until RS-232, Enter ii. If the multimeter does not respond to chances in irradiance, cycle the power on the multimeter (this will happen if the photodiode is disconnected and then reconnected). i. Open Excel Intulink j. Click on the first button in the Intulink toolbar (Connect to multimeter) i. Identify instruments 1. Parity: Even 2. Size 7 3. Baud Rate 9600 4. Handshake DTR/DSR 5. O.K. ii. Click on the multimeter, Connect, Close. k. Click the third button on the Intulink toolbar (Set up multimeter) i. D.C. voltage ii. Auto range iii. Resolution 4 iv. O.K. l. Click the fifth button on the Intulink toolbar (Setup/run logging worksheet) i. Set desired values for sampling frequency and duration. 1. 0.2 is the minimum permitted sampling interval. ii. O.K. (Don t click just yet) 1. Once the O.K. button is pressed, a new worksheet is created and data collection begins. m. Stop, pause, and play in the toolbar can be used, but it is best to be prepared prior to pressing O.K. 9. Obtain four microscope slides. Clean (with isopropanol) and dehydrate bake the slides at 100 C for 3 minutes and prime with P-20 primer (80% PGMEA-20%HMDS)@3000RPM, followed by a bake at 100 for 1min. 10. Coat photoresist at 3000 RPM, and bake at 100 for 3 min. 11. Measure thickness via profilometry after collecting exposure data. 12. Click the O.K. button in the Setup/run logging worksheet window in Excel to begin data collection. Allow several seconds of data collection to pass before opening the shutter and exposing the photoresist to get a dark voltage calibration measurement. a. The curve traced in Excel represents the transmitted radiation signal intensity. Continue to expose until there is no longer any change in response; this is the measurement of the final intensity signal. b. Drag the control slider titled Max Points on Strip Chart all the way to the right to view

MCEE 505 Lithography Materials and Processes Page 5 of 5 the plot in its entirety. 13. Measure the transmission of a blank glass slide. This is a measurement of the signal through the substrate. 14. Measure the transmission with no slide. This is a measurement of the signal with transmission equal to 1. Note this can be used to estimate opening (rise time) and closing delay for the shutter. 15. Calculate and label the y axis of the plot for voltage signal, irradiance, transmission, and absorption from your collected data. 16. Derive A, B, and C. Compare results with those from the spectrophotometric measurement. 17. Repeat steps 1-15 for assigned resists and radiation sources. 18. Remember to turn off the amplifier to avoid running down the battery. 19. Compare results from the resists and explain differences