Wireless Sensor for Humidity / Temperature / CO 2

Similar documents
EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2. EE240 v1.5. preliminary

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2

Series EE240. Manual. Hardware and Software CO 2. BA_EE240_04_e // technical data are subject to change //

Wireless LAN network. Wireless USB network

Wireless LAN network. Wireless USB network

Wireless systems.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

ēko Pro Series System

SELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx

SELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

PLUS WGW420 WIRELESS GATEWAY 868MHz

The Rosemount 848T Wireless Temperature Transmitter

Temperature transmitter itemp PCP DIN rail TMT 121

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

4000RHT DATA SHEET.

Electrical devices may only be mounted and connected by electrically skilled persons.

Data Acquisition Modules/ Distributed IO Modules

B850 Boiler House Energy Monitor

T5340, T5341, T5440, T5441 T6340, T6341, T6440, T6441

The wireless alternative to expensive cabling...

Wireless sensor system

Datalogger DL.OCS/N/RS485

HD 48V01T... HD 4977T...

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

P5201 Universal Programmable Transmitters with Galvanic Isolation

UN2 - Universal controller Building automation s missing link

itemp HART DIN rail TMT112

WIRELESS MODBUS GATEWAY WGW410

ACUMESH - WIRELESS RS485 NETWORK KEY FEATURES ACUMESH - WIRELESS METERING SYSTEM

The wireless alternative to expensive cabling...

SELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx

Battery Powered People Counter with Integral LCD Display & 418Mhz Data Transmitter

Conductivity Analyzer

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

B850 Boiler House Energy Monitor

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Extract from the online catalog

Enforcer 32WE-APP. The control panel Enforcer 32WE-APP is certified to EN50131 Grade 2 and offers a wide range of certified wireless accessories.

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Hi-Inc ULP ( Ultra-Low-Power) Wifi Inclinometer with built-in datalogger

THE CONNECTED INFRASTRUCTURE SOLUTION MONITORING HOW STRUCTURES EVOLVE

Multi-function measuring instrument

Supercal 531 Multi function Integrator that lives up to Your highest expectations

WIRELESS TRANSMITTERS... 1 PRODUCT SELECTION GUIDES...

SEN TRONIC AG ! "#! $ % & "! ' ( #& #$ #& ) * +,! ( ( ( 7 * 6 ( ) 6 * )! ( ( 7 * 6 ( ) 6 ( * ) ( ( / 8 6 ( ) 6 * )! ( ( / 8 6 ( ) 6 ( * )

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Building Intelligence

Multi-function measuring instrument

Table of Contents. HWIO-Gateway User Manual

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

0 2 1 â Ó. itemp HART TMT182. Technical Information

GS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application

0 2 1 â Ó. itemp HART TMT182. Technical Information

Accutech BR10. Wireless base radio

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

FLOW RATE CORRECTION CALCULATOR GDR 1403

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

The wireless alternative to expensive cabling...

Accutech BR20. DIN rail mounted base radio

Temperature head transmitter itemp PCP TMT 181

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

For HVAC monitoring & control, the pharmaceutical industry, building management systems, the paper industry, research, museums and many others.

FLOW RATE CORRECTION CALCULATOR GDR 1403

Hi-Inc ULP ( Ultra-Low-Power) Wifi Inclinometer with built-in datalogger

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

Introduction. Applications

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Humidity Sensor/Transmitter Assembly

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

QPM Series Indoor Air Quality Duct Sensors

G5 System Family and Accessories

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Temperature Input Module for Zone 1 Series 9482/32

Wireless Temperature Sensor with Probe

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

ER WIRELESS TRANSMITTER

MICROCOR WIRELESS TRANSMITTER

Wireless HVAC Sensors

DL/N 70. Datalogger CUSTOMER BENEFITS

Datalogger DL/N 70 Version:

Wireless Temperature Sensor

MULTIFUNCTION GRAPHICAL UNIT MGU 800

Product Features Benefits The IMC Group Ltd.

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Fluke 712B and 714B Temperature Calibrators

Wireless Base Radio. Wireless Transmitters

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

AX-3DS. ULP (Ultra-Low-Power) Wifi accelerometer sensor dedicated to shock. detection with built-in data logger

Transcription:

Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. With a modular structure and easy extendable assortment of sensing probes this allows for usage in many applications. Currently there is a choice from several sensing probes for the environmental values of relative humidity, temperature, and CO 2. Indifferent whether a point-to-point connection or a complex network is required, the series offers the ideal solution. Wireless Sensor for Humidity / Temperature / CO 2 EE244 Transmitter Interchangeable Sensing probes For many years, the proven sensor technology of E+E for the measurement values of humidity, temperature, and CO 2 guarantees precise measurements and the highest longtime stability. The standard interface and the stored calibration data of the sensing probe allow for any choice or combination of the available sensing probes offered. An adaptation or expansion of the number of sensing probes afterwards or an exchange for service purposes can be achieved in seconds a must-have for uninterrupted data acquisition. For high temperature applications or installations in small spaces, the sensing probe can be connected with a sensor cable of up to 10 m (33 ft) in length. Wireless Transmitter EE244 Every transmitter can be equipped with up to three sensing probes. An optional display is available to provide local indication. As a standard, batteries provide for the power supply. For more power demanding applications the device can be powered through an external adapter. EE244 Router Base Station EE241 and EE242 Do you have to traverse a street? The inexpensive point-to-point connection can be accomplished very easily with the EE241. The configuration at the factory of the up to four transmitted measurement values is done in accordance with your specifications, meaning that the values are available as analogue outputs (0 5 / 10 V or 4-20 ) immediately after installation. For more complex networks (up to 500 transmitters or up to 2000 measurement values) is the user-configurable EE242 available. Independent of the topology of the network the integrated Webserver and the Ethernet interface warrants highest flexibility in the configuration of the network with a computer. A simple integration of the measurement system in the customer s network and the easy remote access and diagnostic of the measurement data are additional helpful features. The output values can be transferred as an analogue signal, as well EE241 Base Station EE242 as in digital form via Ethernet. For a bus integration, Modbus will be Sensing Probes supported. With additional extension modules of the series EE243, plainly installed on DIN-rail and digitally interfaced with the basic device, the system can be expanded with extra analogue and digital outputs. The actual measurement values and some operational information can be indicated on an optional display. Router Series EE244-R The radio range is greatly depending on local circumstances. With the router series EE244-R obstacles can be bypassed or the transmission distance expanded. v1.3 124

Typical Applications Pharmaceutical Industry Warehouses Control Rooms Cooling Chambers Museums HVAC Systems Features Interchangeable Sensing Probes Remote Probes up to 10 m (33 ft) Battery Operating Life up to 1 Years Webserver Ethernet Long Rangeability Food Industry Highest Transmission Reliability The data transmission is based on the IEEE 802.15.4 protocol with a transmission frequency of 2.4 GHz, which can be used all over the world without any additional cost. A special identification address, checksums, handshakes, and bidirectional communication provide the highest transmission reliability. Typical radio ranges are 100 m (330 ft) for indoor applications and 1000 m (3300 ft) in the open field. Greater radio ranges are easy obtainable with routers. The self-configuring, scalable, and self-healing mesh network, even when a connection fails, is another component contributing to the improvement of the transmission reliability and security. The highest possible data security level is accomplished with a preset encryption key according to AES-128. Digitale bus connection 1) For bus integration, Modbus will be supported. Communication is implemented via the Ethernet or RS485 interface. Bus connection is only supported by the base station EE242. Installation / Remote Access / Maintenance via Webserver The integrated Webserver allows for platform-independent installation, remote access and easy maintenance with any commercially available browser (Internet Explorer, Firefox, OPERA...) on a computer without additional software. Wireless Networks EE241 (point-to-point connection) EE242 (wireless network) Transmitter (max. 1 piece) Transmitter (max. 500 pieces) *) max. 10 transmitters each node Router (max. 60 pieces) *) Base Station max. 10 radio signals each node *) Radio Ranges: - up to 100m (330 ft) indoors - up to 1000m (3300 ft) in open field Base Station Comparison EE241 EE242 Transmitter: max. number of transmitters EE244 1 500 Router: maximum number of routers EE244-R 60 60 Base Station: configuration of analogue outputs acc. to order code via Webserver user-configurable after delivery -- via Webserver digital interface -- Ethernet, Modbus 1) from Q3/2011 125

Dimensions in mm EE244-Ax3: EE244-Bx2: EE241/EE242: 110 (4.3 ) 90 (3.5 ) 20 (0.9 ) 135 (5.3 ) 108 (4.3 ) 5 (0.2 ) pluggable or remote antenna (antenna cable refer to Accessories) 11 (0.4 ) 11 (0.4 ) 62 (2.4 ) 90 (3.5 ) rail mounting depth: 50 (2 ) socket / ELKA 4012 PG7 Technical Data Measuring values of sensing probes Refer to data sheet of respective sensing probes General Transmission frequency 2.4 GHz Transmission system IEEE 802.15.4 Transmission power 10mW Radio range up to 100m (330 ft) indoors, up to 1000m (3300 ft) in open field Antenna pluggable Approval ETSI / FCC Part 15.247 / IC Electromagnetic compatibility EN61326-1 Industry FCC Part 15 Class B EE244 (Transmitter, Router) EN61326-2-3 Industry ICES-003 Class B Supply transmitter (EE244-A) battery 4x1.5V AA Battery lifetime > 1 year with a measuring data transmission every 5 min. (for T / %RH) External supply transmitter (EE244-B) External supply router (EE244-R) 8...28V DC SELV, typ. I L = 20 at 24V; max. I L = 35 at 24V DC 8...28V DC SELV, typ. I L = 20 at 24V; max. I L = 35 at 24V DC Housing material polycarbonate (PC) Protection class housing IP65 Temperature ranges working temperature range of probe: refer to respective data sheet of sensing probe working temperature range: -40...+50 C (-40...122 F) storage temperature range: Max. number of sensing probes 3 (2) *) Max. number of measuring signals (T, RH..) 6 (4) *) EE241/EE242 (Base Station) Supply voltage SELV 24V AC/DC ±20% digital interface Ethernet Modbus (RTU / ASCII / TCP) 1) Current consumption EE241 typ. I L = 70 at 24V DC; max. I L = 100 at 24V DC EE242 typ. I L = 150 at 24V DC; max. I L = 180 at 24V DC Analogue outputs 0-5V -0.5 < I L < 0.5 0-10V -1 < I L < 1 0-20 / 4-20 R L < 500 Ohm Number of analogue outputs 4 Accuracy of analogue outputs ±5mV resp. ±10µA Temperature dependence mv µa of analogue outputs max. 0.1 C resp. 1 C Resolution of analogue outputs 0.7mV resp. 1.50µA Electrical connection screw terminals max. 2.5mm 2 Housing material polycarbonate (PC) Protection class housing IP20 Temperature ranges *) with external supply 1) from Q3/2011 126 (with display: -20...+50 C / -4...122 F) -40...+50 C (-40...122 F) (with display: -20...+50 C / -4...122 F) working temperature range: -30...+50 C (-22...122 F) (with display: -20...+50 C / -4...122 F) storage temperature range: -30...+50 C (-22...122 F) (with display: -20...+50 C / -4...122 F)

Connection Diagram EE241 / EE242 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 V+ OUT1 OUT2 OUT3 OUT4 + _ 24V AC/DC SELV Overview of Sensing Probes Application Picture Measuring Range Accuracy Order Code Humidity/Temperature Probes RH/T probe for standard applications 0...100% RH ±2% RH (0...90% RH) EE07-PFT1 ±3% RH (90...100% RH) -40...80 C (-40...176 F) ±0.1 C (±0.18 F) at 20 C (68 F) RH/T probe for clean room applications, 0...100% RH ±2% RH (0...90% RH) EE07-MFT9 food and pharmaceutical industry ±3% RH (90...100% RH) -40...80 C (-40...176 F) ±0.1 C (±0.18 F) at 20 C (68 F) RH/T module for installation in small 0...95% RH ±3% RH (10...100% RH) EE03-FT9 spaces or unobtrusive mounting at 21 C (69.8 F) -40...85 C (-40...185 F) ±0.3 C (±0.54 F) at 20 C (68 F) Temperature Probes T probe for standard applications -40...80 C (-40...176 F) ±0.1 C (±0.18 F) at 20 C (68 F) EE07-PT1 T probe for clean room applications, -40...80 C (-40...176 F) ±0.1 C (±0.18 F) at 20 C (68 F) EE07-MT food and pharmaceutical industry CO 2 Probes CO 2 probe for standard applications 0 2000ppm ±(50ppm+2% of m.v.) EE871 0 5000ppm ±(50ppm+3% of m.v.) 0 10000ppm ±(100ppm+5% of m.v.) 127

Ordering Guide POSITION 1: TRANSMITTER / ROUTER POSITION 2: Base station - "point-to-point connection" (EE241) and "wireless network" (EE242) EE241- EE242- Hardware Configuration Frequency 2.4GHz (10mW) A A Output signal 0-5V 2 2 0-10V 3 3 0-20 5 5 4-20 6 6 Display with D D without EE244- Type transmitter A transmitter with external supply B router R Frequency 2.4GHz (10mW) A A Number of 1 1 sensing probes 2 2 3 (not possible with type B - transmitter with external supply) 3 Display with D without EE244- Software Configuration Physical parameters relative humidity RH [%] (A) Output 1 A A / B / C / R of outputs temperature T [ C] (B) Output 2 B A / B / C / R dew point temperature Td [ C] (C) Output 3 C A / B / C / R CO 2 CO 2 [ppm] (R) Output 4 R A / B / C / R Measured value units metric / SI non metric / US E01 E01 T-Scaling (in C or F) -40...60 (T02) 0...50 (T04) Output T Select Txx code Select Txx code Td-Scaling (in C or F) -20...50 (T48) further scalings on request Output Td Select Tdxx code Select Tdxx code CO 2 -Scaling (in ppm) 0...2.000 (C20) 0...10.000 (C22) 0...5.000 (C21) Select Cxx code Select Cxx code POSITION 3: SENSING PROBES Humidity / Temperature probe RH/T (polycarbonate) EE07-PFT1 probe RH/T (metal) EE07-MFT9 module RH/T EE03-FT9 Temperature probe T (polycarbonate) EE07-PT1 probe T (metal) EE07-MT CO 2 probe CO 2 EE871 Accessories / Replacement Parts Transmitter: base Station: - Probe cable for EE07 - (HA0108xx) - Antenna cable 2m (7ft) (HA010330) 2m (7ft) / 5m (16ft) / 10m (33ft) - Crossover cable (PC to base station) ((HA010333) - Connection cable for EE03, 2m (7ft) (HA010328) - External power supply unit (V02) - Connection cable for EE03, 5m (16ft) (HA010329) - Extension module (available 2011) - Antenna cable 2m (7ft) (HA010330) - Bracket for rail installation (HA010203) - Reference probes (HA010403) - Duct mounting kit for EE07 (HA010209) - External power supply unit (V02) Order Example Position 1 - Transmitter / Router: EE244-BA1D Type: transmitter with ext. supply Frequency: 2.4GHz Probe: 1 Display: yes Position 2 - Base Station: EE242-A3D/ABCR-T04-Td48-C20 Frequency: 2.4GHz Output signal: 0-10V Display: yes Outputs: RH, T, Td, CO 2 Measured value units: SI Scaling: T: 0...50; Td: -20...50 Position 3 - Sensing Probes: EE07-PFT1, EE07-MT 128