APS-CU APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC Small design offered in two types: front face sensing and upper sensing. Different-frequency type that allows close-contact installation. Acquiring UL approval, compliant with CE mark. Resin molded type, and protection grade of IP7. Types DC -wire type Non-embedded type DC -wire type Shape Operating distance (mm) type Remarks Non-embedded type.5.5 N.O. N.O. PNP N.O. APS-M-Z APS-S-Z APS.5-M-E APS-M-E APS-M-E APS-M-E APS.5-S-E Different-frequency classification type available ( L added in the end of model number) Provided with a mounting fixture Different-frequency classification type available ( L added in the end of model number) Provided with a mounting fixture * Different-frequency classification types (L) are non-stock product. Shape Operating distance (mm) type Remarks Different-frequency classification type available ( L added in the end of model number) (Excluding E type) Provided with a mounting fixture PNP N.O. APS-S-E APS-S-E APS-S-E Different-frequency classification type available ( L added in the end of model number) (Excluding E type) Provided with a mounting fixture * For APS.5-M-E and APS.5-S-E, UL recognition is being applied (as of May 00).
AC -wire, Non-embedded Type Effective operating distance mm ±% Dimensions (mm) Remarks type NO Rated operating voltage Standard target (mm) Rated operating distance Responding material Differential travel Switching frequency Rated operating current Voltage drop Leakage current Indicator lamp Operating temperature Temperature characteristics Withstand voltage Insulation resistance Vibration resistance Impact resistance Protection grade Casing material Lead wire Tightening torque Weight LED.5 Different-frequency classification model available / operation indicator LED / provided with mounting fixture APS-S-Z APS-M-Z 90 (Minimum ordering qty: 5 units) 90 (Minimum ordering qty: 5 units) DC/ V ( to 0V) Permissible ripple rate: %p-p or less Iron 0 0 t φ. hole 0 to. mm Iron/nonferrous metal (operating distance varies with material) 0% or less 00 Hz max 5 to 50 ma V or less.0 ma or less - to 50 C Within ± 0% (of operating distance at C) 500 VAC, 50/0 Hz ( minute) 50 MΩ or higher (500 VDC) Double amplitude:.5 mm, to 55 Hz ( hours in each of X, Y and Z directions) 9 m/s, within ms ( cycles in each of X, Y and Z directions) IP7 Polycarbonate Oil-resistant vinyl chloride cable.0 m Outer diameter (ø), 0. mm -wire 0. Nm or less Approx. 0 g 7 Cable diameter φ LED *The frequency classification models have L at the end of its model number (non-stock product). APS-CU APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC 7 φ. hole Cable diameter φ.5 5
Rectangular Type APS-S/M Series APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC DC -wire, Non-embedded Type Effective operating distance.5 mm ±5% Dimensions (mm) Remarks type NPN NO NPN NC PNP NO Rated operating voltage Standard detection (mm) Rated operating distance Responding material Differential travel Switching frequency Rated operating current Voltage drop Leakage current Indicator lamp Operating temperature Temperature characteristics Withstand voltage Insulation resistance Vibration resistance Impact resistance indicator LED / mounting fixture sold separately (APS-KNG) APS.5-S-E 90 (Minimum ordering qty: ) DC/ V ( to 0 V) Permissible ripple rate: %p-p or less Iron 5 5 t APS.5-M-E 90 (Minimum ordering qty: ) mm ±% LED 0 to.7 mm 0 to. mm Iron/nonferrous metal (operating distance varies with material) 0% or less 500 Hz max 00 Hz max 50 ma max.0 V or less 0. ma or less - to 50 C Within ± 0% (of operating distance at C) 500 VAC, 50/0 Hz ( minute) 50 MΩ or higher (500 VDC) Double amplitude:.5 mm, to 55 Hz ( hours in each of X, Y and Z directions) 9 m/s, within ms ( cycles in each of X, Y and Z directions) APS-S-E APS-S-E APS-S-E No-load current 0 ma or less ma or less.5 Different-frequency classification model available (excl. E type) / provided with mounting fixture Iron 0 0 t 7 φ. hole Cable diameter φ LED 7 APS-M-E APS-M-E APS-M-E φ. hole.5 Cable diameter φ APS-CU Protection grade Casing material Lead wire IP7 Polycarbonate Oil-resistant cable.0 m Outer diameter (ø), 0. mm -wire Tightening torque 0. Nm or less Weight Approx. 9 g Approx. 0 g *The frequency classification models have L at the end of its model number (non-stock product).
Connection/ DC -wire type -Z DC -wire type NPN output -E DC -wire type NPN output -E DC -wire type PNP output -E Black Black Black Note: indicates a load. Installation and Influence of Surrounding Metals Model number Installation APS.5-S-... APS.5-M-... APS-S-... APS-M-... Placed in parallel with a metallic infinite plane A *.5 0 Placed in parallel with a metallic plane as far as the detection plane B * 7.5 5 Placed in the hole of a window-shaped metallic body C 0 0 Load can be connected either side ( or -) of the power source. A metallic body is placed in front of the Not Present present ( ).7.7 D Two s are placed in parallel with each other D Placed to face each other (Front-sensing type) D 0 0 (in mm) Placed to face each other (Top-sensing type) * Position of the target for a top-sensing model If a metallic is present near the proximity, the operating distance changes and the operation becomes unstable. Secure a sufficient distance from the as long as possible. The D (mm) is the minimum distance from the proximity s detection plane to the metallic. Secure a sufficient distance longer than the indicated. If the B dimension of APS.5-M is.7 mm (close contact), the detection plane edge of the proximity needs to be at least mm away from the metal. D 0 0 APS-CU APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC Precautions on handling the product Before using the product - If no target is present when the is turned on, a detection signal may be output for approx. 5 ms. If a target is present near the, a detection signal may be output for approx. 0 ms. Precautions on installation - When using screws to mount the product, be sure not to give stress to the. * Tightening the screw with a force exceeding the specification value of 0. Nm for the tightening torque may break the. UL approval When using the as a UL approved product, use a Class- power source. A UL approved product is required to be approved in recognition and use a Class- power source. 7
APS-CU APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC Mutual Interference and Classification of Frequencies When using two or more proximity s in close contact with each other, secure an interval between the proximity s (center to center) at least times the operating distance. If the interval is inadequate, mutual interference may occur. In applications where it is impossible to secure adequate intervals, use models classified by frequency. Normally, frequency classification is indicated by an alphabet immediately after the operating distance of the model number. Those models classified by frequency have the following marking on the cable so that they can easily be distinguished from other models. For low frequencies (L) : red spiral mark APS-S-E(M) -E APS-S-EL Detection Area Diagrams (Representative Examples) 7 5 0 Operating distance (mm) Distance from the center of proximity (mm) Model with a standard frequency (normally, "M" is omitted) Model with a lower frequency than the standard frequency Return Shape Characteristics (Representative Examples) Operating distance X (mm) Example: APS-S/M-... APS-S/M-....00.00.00 Iron.00 x 0 0 0 Length of one side of detection a (mm) SUS0 Aluminum Copper a t=mm APS.5-S/M-E.00.00.00.5.5.5 0.5 0 Operating distance (mm) Return Distance from the center of proximity (mm) APS.5-S/M-E Operating distance X (mm) 0 0 0 Length of one side of detection a (mm) Combinations of models classified by frequency APS- - (M)L (Excluding -E type) Iron SUS0 Aluminum Copper x a (can be installed in close contact with each other) t=mm Can be installed with casings in close contact with each other L (M) * To install three or more s in close contact, preliminary study is required.
Installation APS-S-E Mounting surface ø.5 0. 0 hole APS-M-E Mounting surface ø.5 0. 0 hole Mounting fixture for APS-S/M.7..7 M 0.5 pan-head screw (recommended) ±0. M 0.5 tapped hole or ø. hole If the mounting hole is a ø. hole, secure the with a plane washer, a spring washer and a nut. The screw length must be determined based on the thickness of the mounting plate, etc. M 0.5 pan-head screw (recommended) ±0. M 0.5 tapped hole or ø. hole If the mounting hole is a ø. hole, secure the with a plane washer, a spring washer and a nut. The screw length must be determined based on the thickness of the mounting plate, etc. APS.5-S/M Mounting fixture for APS.5-S/M ( sold separately) APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC. ø. 9...7 ø5.5 APS- 5 0. Method for machining the mounting holes 0. ø.5 0 hole M 0.5 tapped hole or ø. hole If the mounting hole is a ø. hole, secure the with a plane washer, a spring washer and a nut. The screw length must be determined based on the thickness of the mounting plate, etc. APS-CU APS-KNG 0 Minimum ordering qty: pcs 9