Product Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe

Similar documents
Technical Information

C0330, C0530, C0630, C0830, C1030 Service Parts

2-pole design. New: Semi-hermetic compressors with 2-pole drive motor for mains voltages of 60 Hz. Now for 60 Hz mains voltage

COMMERCIAL AIR CONDITIONERS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N

Copeland Digital Scroll

4 T V H A D A A

USE OF INVERTERS WITH COPELAND STREAM COMPRESSORS

C0330, C0530, C0630, C0830, C1030 Service Parts

Technical Information

C O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S

SPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)

TSE. Turbomiser. Condenserless water chiller with centrifugal compressors to be connected with a remote. for indoor installation

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

GEA Screw Packages. Plug & play compressor units for industrial refrigeration and air conditioning

A scientific approach applied to intuition

PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES PRESSURE REGULATORS

Commercial Refrigeration Price List

technical data air conditioning systems BS box BSVQ-PV1

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

Multi Room MULTIELITE. Flexible and economical multi room comfort. That s better. That s Actron.

technical data air conditioning systems BS Units BSV4Q100P7V1

VEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

TROUBLESHOOTING. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:

Tentative. Rectifier Module VARIS R-400-H. Tentative VARIS -R

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax:

Chillers for the industrial refrigeration and air conditioning

AC centrifugal fan - RadiCal

Sight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN

Sight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN

GEA Grasso screw packages. The full range of GEA Grasso screw packages. engineering for a better world. GEA Refrigeration Technologies

Code. Edition 04/2013. CPA Screw Air Compressors. Parts List Book

RS /E-EV BLU SERIES

SubArc Digital Series

SubArc Digital Series

Electronic fan speed regulators

PRESS RELEASE. Let s create your success! with GEA at Chillventa 2016

Coalescing Oil Separators

McQuay. Commercial Unitary Rooftop Cooling with Gas Heat. LGA 088, 100 Design 1. Last Manufactured: 2004

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

RS /M MZ SERIES

SONOMETER TM 1100 Ultrasonic compact energy meter

Products catalogue (I-P Edition)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

COMPACT CASSETTE TYPE AIR CONDITIONER

SONOMETER TM 1100 Ultrasonic compact energy meter

SPECIFICATION. Online UPS 3000VA

SubArc Digital Series

WATERFLUX 3000 Quick Start

Guidelines to Using a Three Phase Voltage Monitor

INDUTHERM Mini Vacuum Pressure Casting Machine MC 20V

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CI-tronic Soft start motor controller

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

SUPER INVERTER SERIES MULTI TYPE. Service Manual 2018

Miniature resistance thermometer Model TR33, thread-mounted

Ultrasonic level transmitter, non-contact

WATERFLUX 3000 Quick Start

Industrial air cooler DVS Cooling and working rooms

13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh

Description The aerodynamic shape of the Kongskilde blower ensures high efficiency and low energy consumption.

BLOWERS TRL /FRL/FEA

RS /E-EV BLU SERIES

GI/EMME SERIES

Tangential Fans - Basic principles. Expertise, performance, innovation

General Purpose Drives

DUOLINE. Rotary vane pumps for all applications in the low and medium vacuum range

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Pressure transmitter AKS 32 and AKS 33

PARTS CATALOG R410A. No. OCB603 REVISED EDITION-A. March 2016 HFC SUZ-KA25VA5.TH-ET SUZ-KA35VA5.TH-ET SUZ-KA50VA5.TH-ET SUZ-KA60VA5.

AHSC OWCB ARCHITECT ENGINEER. (Project) Submittal No. Description: Division: Section: Subcontract/Supplier:

AC axial compact fan

Power Regenerative Converter, THYFREC CV240S

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Blowers TRL/FRL/FEA. Number one in process waste handling. Blowers 50 Hz. Kongskilde

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

Addendum No. 1 page 1

Outdoor units. Specifications

Reciprocating compressors for industrial refrigeration

This Chapter contains:

Fan and Pump AC Inverter

PS Panel Saw Ø315mm Max. Blade Diameter $2, $2, Product Brochure For W700. Description. Features

Waste Xpress Parts List

AF91 Adjustable Frequency Drives Series B

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH

YCRS WATER-COOLED REMOTE-CONDENSER CHILLERS

Product Catalog. Split System ACDS-PRC003E-EN. Air-Cooled Condensers 20 to 120 Tons. April 2016

Universal process controller econtrol

TECHNICAL BULLETIN. Direct Impulse Control for Einstein RX

Sight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

RS /E-EV BLU SERIES

EXPLODED VIEW OF KINNEY MODELS KC-5 & KC-8

ADDENDUM NO. 4 November 15, Page 1

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH

(267 kw THROUGH 735 kw)

CONTROL MANUAL. Dry-Pic 09PE - 09VE

Transcription:

Digital Receiver Unit - HLR Product Launch Package Refrigeration Marketing Units Emerson Climate Technologies Europe

Emerson Climate Technologies Existing Digital Range Application Outdoor Installations, such as Convenience stores, Small Retail Stores and Large Kitchen equipment Copeland EazyCool Digital Unit Copeland EazyCool Network Digital Indoor Installations with machine room, as Small Retail & Hard Discount Stores and Storage Warehouse MC Indoor Scroll Digital Unit Digital HLR Liquid receiver Unit, Page 2

Benefits HLR Digital Scroll Receiver Unit for remote condenser installations Compact design, reduced footprint = space Gain Digital modulation = one unit for all store refrigeration system Reduced sound level with remote condenser and low noise fans or water cooled condenser Increased system efficiency by generous condenser sizing opportunities Energy saving by using most efficient Digital Scroll technology Quick and easy installation due to complete equipment scope and clear design Digital HLR Liquid receiver Unit, Page 3

HLR Benefits vs. Competition Wider range of capacity modulation then SH compressor - 10-100 % modulation with HLR and single compressor - 5-100 % modulation with HLR and tandem compressor - 43-100 % modulation with competitive SH and inverter control - 50/100 % modulation with competitive SH and tandem compressor Best in class efficiency - 5% to 10% efficiency advantage depending on model * 100% capacity Digital HLR Liquid receiver Unit, Page 4

Differences Vs Traditional Digital units Digital Receiver Unit (HLR) Indoor & Outdoor Digital Unit Digital Compressor Digital Compressor Electrical panel with: Electrical panel with: EC2-552 & PT4 EC2-55x & PT4 Contactor & overload protector Contactor & overload protector Liquid line w/ Drier & Sight Glass Liquid line w/ Drier & Sight Glass Air cooled condenser Digital HLR Liquid receiver Unit, Page 5 Fan speed controller

Range line-up 4 Models based on actual Digital compressors release Single compressor unit 7 & 10 kw Tandem compressor unit 14 & 20 kw Tan ndem 12 8 HLR31-ZBDT90 LRH24-ZBD90KCE HLR31-ZBDT60 LRH24-ZBD60KCE Single 6 4 HLR13-ZBD45 LRH13-ZBD45KCE HLR13 - ZBD30 LRH13-ZBD30KCE HP 1 3 6 8 11 13 16 18 21 kw @-10/32 10/32 C, Return gas 20 C - R404A Refrigerant Digital HLR Liquid receiver Unit, Page 6

Emerson Climate Technologies Digital Condensing Unit Ranges Digital EazyCool Network Digital EazyCool Digital "HLR" Digital "MC" 0 10 20 30 40 50 60 70 80 kw MT Rating @ -10/32 C - Return gas temp 20 C Digital HLR Liquid receiver Unit, Page 7

Emerson Climate Technologies Digital Condensing Unit Ranges Corner Shop, Proximity, Convenience Stores & Petrol Station Bar & Restaurant Kitchen equipment Hard Discount Small Supermarket City Centre Machine room No Machine room Capacity @ MT 7 & 10 kw 7, 10, 14 & 20 kw 14 & 20 kw - 24~80 kw Modulation range 0.7~10 kw 0.7~20 kw 0.7~20 kw @ 32 C Amb Temp - 20 C returned gas * 24 kw with 2 unit network (Digital unit as master) & 80 kw with 4 units in network (Digital unit as master) Digital HLR Liquid receiver Unit, Page 8

Leaflet Digital HLR Liquid receiver Unit, Page 9

Select Receiver Unit is part of Condensing Units (below item Indoor ) Performance and Data ratings are the same as for the relevant compressors Digital HLR Liquid receiver Unit, Page 10

Scope of Supply Pressure transmitters PT4 24 Volt Digital Solenoid Valve Compressor discharge line Liquid receiver liquid line outlet Filter Drier ADK ALCO HP/LP PS2 Pressure Switch Receiver Sight glass Sight glass ALCO Electrical box with: EC2-552 Digital Unit controller Overload protector & contactor Digital HLR Liquid receiver Unit, Page 11

Single unit Dimensions Digital HLR Liquid receiver Unit, Page 12

Scope of supply Pressure transmitters PT4 Electrical box with: Overload protector contactor EC2-552 Digital Unit controller ALCO LP PS1 Pressure Switch Receiver Sight glass Suction Line Filter Drier ADK ALCO Sight glass ALCO Digital Compressor HP Pressure switch ALCO PS3 (on each comp) Discharge line to condenser Oil separator ALCO Digital HLR Liquid receiver Unit, Page 13 Liquid inlet (from condenser) Liquid line outlet to evaporators

Tandem Unit Dimensions Digital HLR Liquid receiver Unit, Page 14

Specifications HLR 13-ZBD30KCE HLR 13-ZBD45KCE HLR31-ZBDT60KCE HLR31-ZBDT90KCE Single Compressor Unit Tandem Compressors Unit HP 4 6 8 12 Capacity (kw) @ Te.-10, Td: 45 C RGT 20 C Digital Receiver Unit 7,0 10,2 14,1 20,3 Receiver with sight Glass 13 l 13 l 31 l 31 l Suction Line Ø (inch) 7/8 7/8 1 3/8 1 3/8 Discharge line Ø (inch) 5/8" 5/8" 7/8" 7/8" Liquid Receiver Inlet Ø (inch) 5/8 5/8 5/8 5/8 Liquid Receiver Outlet Ø (inch) 5/8 5/8 5/8 5/8 Height (mm) 710 710 910 910 Length (mm) 690 690 920 920 width (mm) 400 400 400 400 Weight (kg) 90 90 130 130 Electrical box (IP54) With: Overload contactor Fuse EC2-552-Controller Liquid line Equipped with Filter drier Sight glass HP/LP Switch PS2 (HP/LP) PS2 (HP/LP) PS1 +PS3 PS1 + PS3 Oil Separator - - All TFD Voltag 3~ 380-420 V @ MT standard conditions EN12900, R404A Digital HLR Liquid receiver Unit, Page 15