TT-SI MHz DIFFERENTIAL PROBE

Similar documents
TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

MD 200A High voltage differential probe

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

400 MHz Passive High-Voltage Probe R&S RT-ZH

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition IM E

PHV RO High Voltage Passive Probe. Instruction Manual

Operator s Manual. PP016 Passive Probe

User s Manual Current Probe IM E. 8th Edition

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Operator s Manual. PP017 and PP018 Passive Probes

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Digital Clamp Meter Model: &

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation


N2792A and N2793A Differential Probes User s Guide

Operator s Manual. PP022 Passive Probe

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

TETRIS User's Guide. High Impedance Active Probe DO177-1

PKT 512A-RO High Impedance Passive Cable Divider

BENNING. CM7 Electrical Tester. Service Information

AMM-1022 Digital Multimeter USER`S MANUAL

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

# Digital Multimeter

Keysight N2790A Differential Voltage Probe. User Guide

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

DS1000E, DS1000D Series Digital Oscilloscope

9 Specifications. Specifications NOMINAL CHARACTERISTICS

N2790A Differential Voltage Probe

5MHz FUNCTION GENERATOR

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

INSTRUCTION MANUAL CLAMP ON PROBE

5MHz FUNCTION GENERATOR

Wide-band Models from DC to 100 MHz

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

AC/DC CLAMP METER USER S MANUAL

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

DS1000B Series Digital Oscilloscope

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

TA MHz oscilloscope probe TA MHz oscilloscope probe

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User Manual Current Probe Instruction Manual

User s Manual Current Probe IM E. 6th Edition

Wide-band Models from DC to 100 MHz

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

The Meter Structure The Figure 2-1 shows the Meter structure.

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

Wide-band Models from DC to 100 MHz

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Pen-type DIGITAL MULTITESTER

USER'S MANUAL DMR-6700

KMD-S04 Multímetro de bolsillo

Service Manual. P5210 High Voltage Differential Probe

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

DVM1190 DIGITAL MULTIMETER

CIRCUIT-TEST ELECTRONICS

DIGIT & POINTER MULTIMETER

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

CONTENTS MS2033A. 1.Introduction Safety Information...01

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Digital Clamp Meter. User Manual

Oscilloscope Probes and Accessories

Model DIGITAL MULTIMETER

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

True RMS Digital Multimeter Model:

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

UT207A/208A/209A Operating Manual. Table of Contents

EC Declaration of Conformity

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

PML 711A-RO High impedance passive probe Features:

Transcription:

TT-SI 9110 100MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC - 1010. 2-031 CATⅢ, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols appear on the product: Danger Protective Attention High Voltage (Earth) Terminal Refer to Manual 2. General Safety Summary To review the following safety precautions to avoid injury and prevent damage to this probe or any products that connected to it. Observe Maximum Working Voltage To avoid any injury, do not use the probe above 1000Vrms CAT III between each input lead and earth or between the two input leads. This voltage rating applies to both of 1/100 and 1/1000 settings. 1

Must be Grounded This probe is grounded with the shell of BNC connector and an auxiliary grounding terminal, through the grounding conductor of the power cord of the measurement instrument. Before making connections to the input leads of this probe, ensure that the output BNC connector is attached to the BNC connector of the measurement instrument and the auxiliary grounding terminal is connected to a proper ground, while the measurement instrument is properly grounded. Use Fused Test Prods if Necessary If this probe is intended to use for measurements in circuits of INSTALLATION CATEGORY Ⅲ, it should incorporate with fused test prods. Do Not Operate Without Covers To avoid electric shock or fire hazard, do not operate this probe with covers removed. Do Not Operate in Wet/Damp Conditions To avoid electric shock, do not operate this probe in wet or damp conditions. Do Not Operate in Explosive Atmosphere To avoid injury or fire hazard, do not operate this probe in an explosive atmosphere. Avoid Exposed Circuitry To avoid injury, remove jewelry such as rings, watches and other metallic objects. Do not touch exposed connections and components when power is present. Use Proper Power Source To ensure this probe function well, use four AA cells or 6VDC/200mA mains adaptor or regulated 9VDC/120mA mains adaptor or power leads. Do not operated with Suspected Failures If you suspect there is damage to this probe, have it inspected by qualified service personnel. 3. Description By enabling conventional oscilloscopes to display and measure in-circuit waveforms that are referenced to high common mode voltages, the differential probe extends the measurement capability of oscilloscopes in electronic power converters, inverters, motor speed controls, switch mode power supplies and many applications. 2

4. Installation a. Simply plug-in the BNC output connector to the vertical input of a general purpose oscilloscope or other measurement instrument, and connects the auxiliary grounding terminal to a proper ground. The measurement instrument must have a ground referenced. b. Install four AA cells or connect an appropriate power source to this probe. c. Select the proper attenuation ratio, when measuring signals below 140V, switch the attenuation ratio to 1/100 in order to get higher resolution and less noise. Otherwise, set the attenuation to 1/1000. WARNING. To protect against electric shock, use only the accessory supplied with this differential probe. d. Using the appropriate probe accessories, connect the input to the circuits under measurement. CAUTION. This probe is to carry out differential measurement between two points on the circuit under measurement. This probe is not for electrically insulating the circuit under measurement and the measuring instrument. 5. Appearance The differential probe looks as follows. A B C A. Output Lead The BNC output connector and an auxiliary grounding terminal are connected to the oscilloscope. B. Input Leads The input leads of the differential probe connect to sprung hooks that come with the probe. C. Sprung Hooks The sprung hooks are connected safely to test points in circuits under measurement. 3

6. Power Leads We offer two types power leads; a. Lemo Lead: For the oscilloscope whose power connector is Lemo connector. b. Probus Lead: For the oscilloscope whose power connector is Probus connector. 7. Specifications Bandwidth Attenuation ratio 1:100/1000 Accuracy ±2% Rise Time Input Impedance Input Voltage DC to 100MHz (-3dB) 3.5ns 4MΩ //7pF each side to ground - Max. Differential * ±140V(DC + Peak AC) or 140Vrms @ 1/100 1400V(DC ± + Peak AC) or 1000Vrms @ 1/1000 - Common Mode Range * ±1400V(DC + Peak AC) or 1000Vrms @ 1/00 & 1/1000 - Absolute Max. Voltage * ±1400V(DC + Peak AC) or 1000Vrms CATⅢ @ 1/100 & 1/1000 (Differential or Common Mode) Output Voltage - Swing (into 50kΩ load) ±7V - Offset (typical) <±5mV - Noise (typical) 0.9mVrms - Source Impedance (typical) 50Ω 4

CMRR (typical) Ambient Operating Temperature Ambient Storage Temperature -80dB @ 60Hz; -50dB @ 1MHz -10 to 40-30 to 70 Ambient Operating Humidity Ambient Storage Humidity Power Requirements 25 to 85% RH. 25 to 85% RH. - Standard 4xAA cells or 6VDC/200mA mains adaptor or regulated 9VDC/120mA mains adaptor ** - Option Power leads Length of Input Leads Length of BNC Lead Weight Dimension (LxWxH) 30cm 90cm 500gms 207mm x 83mm x 38mm * Voltage limit is the lesser of the DC+Peak AC and RMS values.. ** a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can t be operated properly. b. Polarity is + inside and outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur. c. When the voltage of the cells become too low, the power indicator on the panel will flicker. 8. Derating Curve The derating curve of the absolute maximum input voltage is shown as follows; Voltage (Volt rms) 10000 1000 1000 1000 100 20 10 1,0E+05 1,0E+06 1,0E+07 1,0E+08 Frequency (Hz) 5

9. Overrange Indicator The overrange indicator lights red, if the voltage of the input signal exceeds the linear operating range of the probe. When this happens, the signal on the probe output may not accurately represent the signal on the probe input. 10. Inspection Procedure a. Connect the BNC output connector to the vertical input of a general purposed oscilloscope. b. To install four AA cells or connect an appropriate mains adaptor to this probe. c. Set the oscilloscope input coupling to DC and the 1V/div. Center the trace on the display. d. Connect the sprung hooks of the probe to power lines. e. Set the range of the probe to 1/1000. f. Then, a 50Hz/60Hz sine-wave of proper amplitude will be displayed on the screen of the oscilloscope and this means the probe is working properly. 11. Cleaning Use a soft cloth to clean the dirt. Prevent damage to probe a. Avoid immersing the probe. b. Avoid using abrasive cleaners. c. Avoid using chemicals contains benzene or similar solvents. Lemo and Probus are registered trademarks. Date: Aug. 30,2006 TESTEC Elektronik GmbH Bornheimer Ldstr. 32-34 60316 Frankfurt / Germany Tel.: +49-(0) 69 94 3335-0 Fax: +49-(0) 69 94 333555 website: www.testec.de e-mail: info@testec.de 6