Energate Foundation Meter Data Collector Installation Guide

Similar documents
PowerCost Monitor. Installation Guide. Install the Batteries in the Display Unit. Install the Batteries in the Sensor Unit

User Manual. Please read before using this equipment.

GENERAL INFORMATION BATTERIES: WHAT DO I NEED TO KNOW ABOUT BATTERIES?

Vinyl Cutter Instruction Manual

Bushwacker Jeep Flat Style Fender Flares Rear Pair (JK Wrangler 2dr)

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Bushwacker Jeep Flat Style Fender Flares Front Pair

BATTERY GRIP INSTRUCTION MANUAL

Z-Truck Up-and-Down Motion. Y-Truck Side-to-Side Motion. Head. Squaring Plate. Sliding Plate FIGURE 1: THE CARVEWRIGHT MACHINE

Endeavour 3 Leg Adjustable Height Desk. UL Number: E MANUAL FOR ASSEMBLY AND USE

Laser LA-4P. Operating instructions

Quick Start Guide. Contents

Expandable Series Wireless Multi Unit Doorbell System

UPLIFT Height Adjustable Standing Desk 3-Leg (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

WIRELESS Energy Monitor - Smart Meter

VZ-EA2 Product Manual

Harmony Remote Repair

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Rigid and Flex Tubular Skylights Installation Instructions

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS

MLR-1105 (DC battery type door chime receiver) LMLT-711 (push unit door chime transmitter)

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions

GR FAQS. La Crosse Technology, Ltd. Page 1

imove-f Assembly Manual (Motorized Version-M1/M2)

ARROW SAW PRECISE CUT 8000 RPM WITH DUST COLLECTING ATTACHMENT INSTRUCTION BOOK MODEL NO

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

TREX TRANSCEND RAILING

Termination Procedure

Series 1500 Aluminum Door Canopy

GETTING STARTED. Instructions IMPORTANT PS B PS B. Record the serial number from the tag on the door front.

Cabinet is 90% assembled, all you need to do is to attach the legs, lay the glass top on the cabinet, connect the faucet, drains & ptrap.

Service Manual for XLE/XLT Series Laser Engravers

POWER PET. Low-E Automatic Patio Pet Door Installation and Operating Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions For Slider Casement Air Conditioners

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

Build your own. Stages 7-10: See Robi s head move for the first time

2017 UPDATED INSTALLATION INSTRUCTIONS

STANDARD OPERATING PROCEDURE STAT-SITE M HGB

Installation Instructions

Written By: Joseph Schlesinger

Removing and Replacing the Y-truck

UPLIFT 2-Leg Height Adjustable Standing Desk

The Useless Machine. Parts Only - Build Guide v0001

SE5a Instrument Board part 2 - rev 1.1

The Useless Machine. DIY Soldering Edition. Instruction Guide v0004

Adhesive Application & Laminating System

PMR ELECTRONIC LOCK USER GUIDE

Assembly Instructions 10 X 10 Aluminum Frame Building

UPLIFT 2-Leg Height Adjustable Standing Desk - For use with UPLIFT Eco and Eco Curve desktops -

Please read carefuly before using. Aerobic Lateral Trainer ASSEMBLY MANUAL H901

Hardware Installation. Do this first:

Aqua-Gen 3BR INSTRUCTIONS

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

Series 1100 Aluminum Door Canopy

Stuff-Your-Stuff Platform Bed (Twin and Full)

AUC Cell Assembly Torque Stand. User Manual

Dear Valued Customer,

Basic Spring Motor Roller Shades

Installing Your Electronic Deadbolt

C-Bot. User Guide. Cautionary and Warning Statements

Premium Light Filtering Sheer Shade

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

*Patent Pending. *Trademarked. Series II. Glass Conversion Kit. (888) One-Products (888)

Standard Operating Procedure

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

CONTENTS. Note: If using Alkaline Rechargeable battery place solar panel under light source for 6 hours with rechargeable battery in place to charge.

GC-1032 Metal Detector OWNER S MANUAL

Sliding Door Kit

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

Learning to use your easypod. [somatropin (rdna origin) for injection]

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

Traditional Wall Mounted Potfiller

MOTOR & BULK HEAD. A Manual for Repair and Maintenance Technicians

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

BRM * This item is for consumer use only and it is not meant for commercial use.

Powermatic Model 31A Combination Belt-Disk Sander

Replacing the print cartridges

TM Quick Start Guide

the slim retracting clothesline product manual

Tools: Sharpie, Square, Vise, Hack saw, Ruler, Punch, Hammer, File. 2. Cut the stock Place stock in vise and cut with hack saw

UNIVERSAL TWO TIER. Change Table Model # IMPORTANT: RETAIN FOR FUTURE REFERENCE, READ CAREFULLY

How to Cut a Handlebar for Installation of PadLoc Grips. How to Cut a Handlebar for Installation of PadLoc Grips

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

Extendable Large Dovetail Jig

Parts List (Continued) 18 each: #8 x 0.625" Truss Head Phillips Screw 20 each: #8 x 1.75" Flat Head Phillips Screw 4 each: #8 x 1.25" Flat Head Philli

Lexus ES350 Window Clip Replacement

Build your own. Pack. Stages 19-22: Continue building Robi s left arm

a.k.a. casegoods instructions

Aqua-Gen 3PV INSTRUCTIONS

CD42-STS Operating Manual Diver/ROV Pipeline Pig Location & Tracking System

Installers guide Deadbolt 02.

INFINITE RANGE - HINGE DOOR

Digital Wireless Weather System

#4 Phillips Driver Bit 1/8, 4mm, 5.5mm & 8mm (5/16 ) Allen Wrench. Safety Glasses

Laminate Cabinet Installation Instructions

BMW E39/E53 Android Touch Screen Radio Installation Instructions

Transcription:

Energate Foundation Meter Data Collector Installation Guide The Meter Data Collector works with Foundation s built-in Meter Data Receiver. The collector attaches to the meter provided by your electricity provider where it gathers information about energy consumption and transmits it to Foundation. The Meter Data Collector works with Foundation models FZ100C and FZ100CF only. Important Safety Precautions Install your Meter Data Collector on a dry day and take all necessary safety precautions, particularly if you need to use a ladder for installing it. In addition, please read and apply the safety instructions below at all times. Do not immerse the Meter Data Collector s sensor unit in any liquid. Do not drop or cause any sudden impact to the sensor unit. If disposing of the sensor unit, do so in accordance with your local waste disposal regulations. Take precautions when handling batteries. They can cause injuries, burns, and/or property damage as a result of contact with metal objects, heat, and corrosive materials. Read all the instructions carefully before using your Meter Data Collector. Verify the Contents of the Box Verify that your box contains all these components in addition to this installation guide. If any item is missing, please contact your reseller. Note: You may require two rubber shims. For additional battery information, see Technical Specifications. Meter Data Collector Installation Page 1 AW000925-A

Install the Batteries in the Sensor Unit Turn the screw counter-clockwise to open the sensor unit battery compartment cover. Insert two AA batteries in the orientation indicated by the + and signs printed on the circuit board, then close and lock the battery compartment by turning the screw clockwise. Do not overtighten. The red STATUS indicator should illuminate within 10 seconds. Verify Your Meter s Watt-Hour Constant (Kh) The Meter Data Collector works only with digital (electronic) meters with a disk emulator that uses a watt-hour constant of 1.0. The watt-hour constant is sometimes called a disk or pulse constant. The watt-hour constant is indicated on the face of the meter, usually with the letters Kh (less often the letters Ks or Kt). In most cases, the watt-hour constant is 7.2 if it has dials and a spinning mechanical disk, or 1.0 if it has a digital readout. Determine Your Meter Type In some cases, it may be necessary to adjust your sensor unit to fit your particular meter. Therefore, it is extremely important to determine exactly what kind of meter is installed on your premises. Locate your meter and use the following illustrations to determine its type. Note: The Meter Data Collector does not work with Elster A3TL meters. Meter Data Collector Installation Page 2 AW000925-A

Type 1 Meter: Optical port on the face, 1.5 inches or more from the outer rim On this type of meter, the optical port is located at least 1.5 inches (37 mm) from the meter s outer rim. If in doubt, measure the distance using a ruler. (One is printed at the end of this guide.) Note: The optical port can be located at either the right (3 o clock) or left (9 o clock) position on your meter. Type 2 Meter: Optical port on the face, less than 1.5 inches from the outer rim On these meters, the optical port is on the face, located less than 1.5 inches (37 mm) from the meter s outer rim. If in doubt, measure the distance using a ruler. (One is printed at the end of this guide.) This type of meter may require you to mount the supplied rubber shims on the underside of the sensor. For example, Elster RS1/REX meters require one shim. Elster RS2 and Sensus icon A Residential meters do not require a shim. Meter Data Collector Installation Page 3 AW000925-A

Type 3 Meter: Optical port on the top On this type of meter, the optical port is located on the top portion of the meter. This kind of meter requires you to reconfigure the sensor and install the clear alignment template. Meter Data Collector Installation Page 4 AW000925-A

Prepare Your Sensor Unit Instructions: Perform the operations that correspond to your meter type. When you are done, go to Install Your Sensor Unit. Type 1 Meter: Optical port on the face, 1.5 inches or more from the outer rim 1. Open the Sensor Arm latch (G) by pulling upward. 2. Ensure that the Sensor Arm (B) is pushed in as far as it will go into the body of the sensor unit. 3. Close the latch (G). Type 2 Meter: Optical port on the face, 1.5 inches maximum from the outer rim For examples of meters and the number of shims they require, see the Type 2 Meter information in Determine Your Meter Type. 1. Perform the same steps as described for a Type 1 meter. 2. Peel off the adhesive backing from the shim. Meter Data Collector Installation Page 5 AW000925-A

3. Position the shim on the underside of the sensor unit casing with the adhesive side down (that is, so that it sticks to the back of the sensor unit). 4. Press the shim in place onto the underside of the sensor unit casing. Type 3 Meter: Optical port on top 1. Open the Sensor Arm latch (G) by pulling upward. 2. Gently pull the Sensor Arm (B) completely out of the body of the sensor unit. 3. Turn over the Sensor Arm (B). 4. Push the thin end of the Sensor Arm (B) upwards through the latch opening and press the Sensor Arm firmly into the cavity. Meter Data Collector Installation Page 6 AW000925-A

5. Firmly push the Sensor Head (C) behind the strap, and as far down as it can go into the bottom cavity of the body. The dark red Optical Sensor (D) must be clearly visible below the clamp. If necessary, use a dull pointed object, such as a ballpoint pen to push the head (C) downwards. 6. Tuck the wire (E) into the side cavity (F). 7. Close the latch (G). Meter Data Collector Installation Page 7 AW000925-A

Install Your Sensor Unit Please read Important Safety Precautions before starting the installation. Important: Turn on a high energy-consuming appliance in your house, such as your electric stove or dryer. This temporarily increases your electricity consumption and enables the sensor to begin reading your meter s output in less time. 1. Go to your meter, taking the following items with you: This guide Sensor unit A clean damp cloth 1 large flat-head screwdriver Clear alignment template (if you have a Type 3 meter) Stepping stool or ladder, if your utility meter is located higher than eye level. DO NOT USE A CHAIR OR OTHER UNSTABLE PLATFORM. 2. Perform the installation steps for your type of meter (see Determine Your Meter Type). Note: During installation, it is the dark red Optical Sensor (D) that you align with the appropriate optical port on the meter. This is the sensor that is closest to the tip of the sensor head. Type 1 & 2 Meters 1. After carefully wiping the meter dome clean with the damp cloth, fit the sensor unit over your utility meter as shown, so that the Sensor Head (C) sits as close as possible to the front of the glass dome. 2. With your screwdriver, tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for slight adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems. 3. Position the Sensor Arm (B) so that the dark red Optical Sensor (D) in the Sensor Head (C) is located exactly above the left optical port. (For example, if the ports are on the right side of the meter, align with the innermost port. For ports on the left, align with the outermost port.) When the sensor arm is positioned correctly, the rib closest to the end of the Sensor Head (C) is aligned with the optical port on the left. Make sure the sensor arm is flush against the meter glass. Meter Data Collector Installation Page 8 AW000925-A

Optical port on left or right The Sensor Head rib closest to the tip must align with the leftmost hole 4. Press and release the RESET button. The red STATUS indicator turns on solid and then starts to flash regularly. Regular flashing indicates that the sensor has detected the signal from your meter. If necessary, adjust the sensor until the indicator is flashes regularly. 5. Within 1 minute of detecting the signal from your meter, the indicator begins to flash irregularly. Irregular flashing indicates that the sensor is reading the meter s output correctly. Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life. Note 2: If the STATUS indicator does not flash at all and stays lit solid, repeat the steps above and recheck for proper alignment. Type 3 Meters 1. Stand directly in front of your meter, at a height where you can see the optical port. The optical port itself looks like a small protruding pipe in the center of the top portion of the meter. Carefully wipe the meter dome clean with the damp cloth. 2. Hold the template with the protruding tab facing you and the white arrow pointing away from you. Peel off the adhesive backing. Meter Data Collector Installation Page 9 AW000925-A

3. Position the template on the meter so that the horizontal white line on the template follows the front edge of the meter dome, and the white arrow points straight to the optical port. 4. Carefully stick the template to the dome, pressing it in place on top first, then on the protruding tab down the front of the dome. 5. Slide the sensor unit over the glass dome and align the edges of the sensor unit body with the white side lines. 6. Tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems. 7. Open the Sensor Arm Latch (G) and sight down the opening. You see a vertical plastic tab painted white on the inside of the sensor unit body. 8. Sighting through the opening, position the sensor unit so that the white plastic tab on the body is aligned with the arrow on the template. Meter Data Collector Installation Page 10 AW000925-A

9. Press the RESET button and wait 10 seconds. The red STATUS indicator turns on solid. 10. Keeping the white lines on the body and template aligned, slowly and gently push or pull on the sensor unit until the red STATUS indicator starts flashing regularly, indicating that the sensor has detected the signal from your meter. Within 1 minute, the indicator starts to flash irregularly to indicate that the sensor is reading the meter s output correctly. Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life. Note 2: If the STATUS indicator doesn t flash at all and is steadily lit, repeat the steps above and recheck for proper alignment. Meter Data Collector Installation Page 11 AW000925-A

Connect the Meter Data Collector to Foundation Use the Installer Setup menu to connect Foundation s built-in Meter Data Receiver with the Meter Data Collector. Note: To successfully pair Foundation with the Meter Data Collector, you may need to repeat the following steps after fine-tuning the sensor unit s placement. For information on adjusting the sensor unit s placement, see Install Your Sensor Unit. 1. Ensure that the Thermostat home screen is displayed. 2. Press the Menu/Select button 3. Press the Up or Down button to highlight Installer Setup, and then press the Menu/Select button. 4. Press the Up or Down button to highlight Meter Data Collector, and then press the Menu/Select button. 5. Press the Up or Down button to highlight Pair with Collector, and then press the Menu/Select button. 6. When prompted to reset the sensor pairing, press the Up or Down button to highlight Yes, and then press the Menu/Select button. Meter Data Collector Installation Page 12 AW000925-A

7. When prompted to enter the Installer Password, press the Up or Down button to highlight the password entry field, and then press the Menu/Select button. The default installer password is INST. 8. To enter the password: Press the Up or Down buttons to navigate to the appropriate letter or number. Press the Menu/Select button to select the letter or number and move to the next character in the password. 9. A screen that confirms Foundation is resetting is displayed, and then Foundation returns to the Meter Data Collector menu. 10. Press the Reset button on the sensor unit to complete the connection. For the expected red STATUS indicator behavior after resetting (flashing regularly, then irregularly), see Install Your Sensor Unit. 11. In the Meter Data Collector menu, press the Up or Down button to highlight Link Info, and then press the Menu/Select button Until the connection is complete, the first Link Info screen displays the message Pairing with Collector. Then Foundation displays the connection information screen. Meter Data Collector Installation Page 13 AW000925-A

Finalize the Installation 1. Tighten the Clamp (A) just enough so that the sensor cannot move. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems. 2. Turn off the appliance you turned on when you started. Your Meter Data Collector should now be correctly installed and communicating with Foundation. If there is a problem, please see the Troubleshooting section in Installation Guide for Energate Thermostats. Technical Specifications Power 2 AA alkaline batteries (LR6 or equivalent; expected battery life of 12 months) 2 AA lithium batteries for temperatures consistently below -20 C (expected battery life of 18-24 months) Wireless Communications Frequency: 433.92MHz, Update Rate: Approximately every 30 seconds Range: Up to 30 m (100 feet) line-of-sight. Subtract 5 m (15 feet) for each wall between Foundation and the Meter Data Collector and 3 m (10 feet) for any metal or electrical barriers (for example, metal siding, motor vehicles or electrical appliances). Range is also reduced by cold weather and as the batteries lose their charge. Operating Temperature Range -40 C to 60 C (-40 F to 140 F) Meter Data Collector Installation Page 14 AW000925-A