SKA Activity Report. Domingos Barbosa Cláudia Camacho* Rogério Nogueira. Aveiro, 16 th of June, 2011

Similar documents
Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

Optical Communications and Networks - Review and Evolution (OPTI 500) Massoud Karbassian

Cisco s CLEC Networkers Power Session

40Gb/s & 100Gb/s Transport in the WAN Dr. Olga Vassilieva Fujitsu Laboratories of America, Inc. Richardson, Texas

Optical Networks emerging technologies and architectures

White Paper. 100G beyond 10km A global study coherent and PAM4 Technology. Date: By Ambroise Thirion

Optical Communications and Networks - Review and Evolution (OPTI 500) Massoud Karbassian

WDM. Coarse WDM. Nortel's WDM System

Global Consumer Internet Traffic

WDM in backbone. Péter Barta Alcatel-Lucent

CWDM Cisco CWDM wavelengths (nm)

Qualifying Fiber for 10G Deployment

Cisco ONS Pluggable Optics Series Modules for the Carrier Packet Transport (CPT) Platform

Emerging Highly Compact Amplification Solutions for Coherent Transmission

GYM Bilgi Teknolojileri

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

Good Things Come in Small Cubes. Cube Optics Multiple 100G DWDM Testing March 2014

Datasheet. SFP Optical Transceiver Product Features SFP-MR2-K100DXX. Applications. Description. SFP DWDM 100 km transceiver 2G SONET OC-48 / STM-16

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Spectral-Efficient 100G Parallel PHY in Metro/regional Networks

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

100G Coherent Transceiver Technologies for DWDM Metro Applications: Key Requirements and Design Trends

Optical Transport Technologies and Trends

Multiplexing. Timeline. Multiplexing. Types. Optically

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Overview. Highlights. General Specification. Datasheet

ADVANCED OPTICAL FIBER FOR LONG DISTANCE TELECOMMUNICATION NETWORKS

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

VePAL UX400 Universal Test Platform

Openwave Project Challenges and Method for 100G Alien Wave USA-Brazil

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Optical Transport Tutorial

Cisco Smart SFP Network Interface Device

Optinex. Alcatel 1686 WM. 32 Channels DWDM System (Regional & Metro)

RXT-1200 Modular Test Platform

DATASHEET 4.1. SFP+, 10GBase-ZR, Multirate Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp.

User Manual. Installation Transmit Receive Module SFP/XFP

Optical Modulation for High Bit Rate Transport Technologies

THE ROLE OF HIGHER BAUD RATES IN EVOLVING COHERENT TRANSPORT

Emerging Subsea Networks

Thursday, April 17, 2008, 6:28:40

SO-SFP-16GFC-ER-Dxxxx

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Peter J. Winzer Bell Labs, Alcatel-Lucent. Special thanks to: R.-J. Essiambre, A. Gnauck, G. Raybon, C. Doerr

Multichannel DWDM applications with single channel optical interfaces for repeaterless optical fibre submarine cable systems

Implementing of High Capacity Tbps DWDM System Optical Network

DS3880R1115. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series

30 Gbaud Opto-Electronics and Raman Technologies for New Subsea Optical Communications

Project: IEEE P Working Group for Wireless Personal Area Networks N

Deployment & Service Activation at 100G & Beyond

Cisco PONC Pavan Voruganti Senior Product Manager. March 2015

DWDM 101 BRKOPT Rodger Nutt High-End Routing and Optical BU Technical Leader

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Polarization Optimized PMD Source Applications

Trends in Optical Transceivers:

Photonic Integrated Circuits for 400 Gigabit and 1 Terabit Coherent Transport

DS3880R1114. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series

Datasheet. SFP Optical Transceiver Product Features SFP-622-K160DXX. Applications. Description. SFP DWDM 160 km transceiver 622Mb SONET OC-12 / STM-4

Single- versus Dual-Carrier Transmission for Installed Submarine Cable Upgrades

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

Efficiently Supporting Aggressive Network Capacity Growth in Next-Generation ROADM Networks

Innovations in Photonic Integration Platforms

from ocean to cloud EFFICIENCY OF ROPA AMPLIFICATION FOR DIFFERENT MODULATION FORMATS IN UNREPEATERED SUBMARINE SYSTEMS

JD061A-C. 1.25Gbps SFP Transceiver

Datasheet. SFP Optical Transceiver Product Features SFP-41D-K050CXX. Applications. Description. SFP CWDM 50 km transceiver 4G LX Fiber Channel

Filling the fiber: Factors involved in absolute fiber capacity Geoff Bennett, Infinera UKNOF September 2007

Extending 100Gbit/s Ethernet. Ariën Vijn

Optical DWDM Networks

Si Photonics Technology Platform for High Speed Optical Interconnect. Peter De Dobbelaere 9/17/2012

Optical Complex Spectrum Analyzer (OCSA)

GLC-LH-SMD-AO. 1.25Gbps SFP Transceiver

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

40Gb/s Coherent DP-PSK for Submarine Applications

Ultra-long Span Repeaterless Transmission System Technologies

Opti Max Optical Node Series

Pass Cisco Exam

ISSCC 2006 / SESSION 13 / OPTICAL COMMUNICATION / 13.2

DWDM XFP Series. XFPD-ER-T and XFPD-ER-T1 Single-Mode Tunable XFP Transceiver RoHS6 Compliant. Features. Applications. Product description

DWDM SFP 4.25Gb/s Transceiver 30Km Hot Pluggable, Duplex LC, 3.3v C Band 100-GHz DWDM DFB-LD PDSFP-96-1XX12-22F

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

XFP-10G-Z-OC192-LR2-C

Low Power DSP and Photonic Integration in Optical Networks. Atul Srivastava CTO, NTT Electronics - America. Market Focus ECOC 2014

PROLABS JD121B-C. 10 Gigabit 1550nm SingleMode XFP Optical Transceiver, 40km Reach.

Emerging Subsea Networks

XFP-10GER-192IR V Operating Environment Supply Voltage 1.8V V CC V Operating Environment Supply Current 1.8V I CC1.

Analyses of 100 Gbps Coherent System Performances

SUBMARINE SYSTEM UPGRADES WITH 25 GHZ CHANNEL SPACING USING DRZ AND RZ-DPSK MODULATION FORMATS

Design of Ultra High Capacity DWDM System with Different Modulation Formats

Dispersion in Optical Fibers

Product Specification. 10Gb/s DWDM 80km XFP Optical Transceiver FTRX xx

VIRTUAL SEGMENTATION. Executive summary. Online. Website: technetix.com

Towards an objective for 400 Gb/s for DCI applications

Applications: Description:

Transcription:

Aveiro, 16 th of June, 2011 SKA Activity Report Domingos Barbosa Cláudia Camacho* Rogério Nogueira 2005, it - instituto de telecomunicações. Todos os direitos reservados.

Signal Transport for SKA : from antenna to station to correlator Terabits of data ; very high traffic (200x WIT 2009) Time critical transmission (response of telescopes), requiring minimal delay Wide Spread Areas, continental sizes. Missing or minimal infrastructure Service: building, maintaining, operating 2

Signal Transport for SKA : from antenna to station to correlator Huge progress in available technology 9.6Tbps with 100G per channel Synchronization options with low delay and jitter Up to 2500km without regeneration-> less equipment High degree level of automation 3

Signal Transport for SKA : from antenna to station to correlator Choose future-proof technology, easily upgradable and scalable Choose and install fiber infrastructure Choose how to build and minimize maintenance, and operating costs Guarantee low cost/bit 4

StaN related visits/workshops: Feb 2010 (Lisbon) - AAVP visit @ Nokia Siemens Networks (NSN) Portugal. May 2010 (Lisbon) - AAVP, SPDO, IT, CICGE ; @ NSN Sep 2010 (Aveiro) - 4th Radionet Enginering Forum Workshop ; with presence of Eriksson, NSN, SPDO, South Africa, Europe. Overview of existing technology; on custom made for radioastronomy vs general industry driven products Forecast on industry standards and plans --> discussion on availability of high-performance components & parts for SKA systems within SKA timeframes. I/O impact on antenna and correlator buffers. 5

Contents What are the nonfunctional requirements for the SKA in terms of: Network Management Swappable Units Line-Side and Client-Side Interfaces 40G Transmission vs 10G? Commercially availability today Market Drivers Technical Issues Cost & Power drivers? Higher Transmission rates, ie 100G? Green energy powered? Self-sustainable? 6

Contents Work developed at IT, in the framework of the PrepSKA FP7 Consortium, GRIT (IT s RadioAstronomy Group) and the Optical Communications Group at IT (Aveiro), for the Square Kilometer Array (SKA) project. Phase 1 Scenarios and Simulations Phase 2 Scenarios and the need for infrastructure developments 7

Nonfunctional Requirements The following slides describe the nonfunctional requirements for the SKA. In order to achieve them, an intensive research of today s commercially deployed and available technologies in the market was made. More than 20 companies were found, which provided all the information on their products needed for this study. A complete list of the standardized technologies and their features was created and through that list it was possible to define the main requirements for the SKA. 8

Network Management Network management is essential to ensure efficient and continuous operation of any network. The table below describes the main requirements in terms of network management for the SKA. Automatic Fault Recovery Channel Monitoring Channel Optimisation Alarm Reporting Fault Isolation Display and Access Isolation, Protection and Recovery EN 300 386 EMC EN 55022 - Radiated emissions EN 61000-3 Harmonic current emissions EN 61000-4 Radiated immunity Management layer interfaces SNMP interface CRAFT interface TL1 interface Ethernet interface RMON interface Automatic switching/ Multi section protection ASP/MSP G.709 Interface 9

Network Management Each main requirement of the previous table has several subrequirements to be considered for the SKA. Taking Channel Monitoring from Automatic Fault Recovery as an example: Automatic Fault Recovery Channel Monitoring Channel Optimisation Alarm Reporting Fault Isolation Display and Access Laser bias current Laser temperature Transmitter optical output power Receiver optical input power Central wavelength Auto wavelength discovery Optical Signal to Noise 10

Swappable Units Scalable capacity, faster provisioning, spare management and low costs are some of the SKA demands. The following table lists some of the ways to achieve them. Swappable Units Replacement of units under power (hot swappable) Field replaceable units Pluggable, interchangeable, and tunable units Local configuration and upgrade capacity Remote configuration and upgrade capacity Scalable number of channels Self tune capability when new wavelength channels added Any mix of services on a single card Scalable line speeds 10G to 40G, 40G to 100G and 10G to 100G 11

Swappable Units Scalable capacity, faster provisioning, spare management and low costs are some of the SKA demands. The following table lists some of the ways to achieve them. Swappable Units Replacement of units under power (hot swappable) Field replaceable units Pluggable, interchangeable, and tunable units Local configuration and upgrade capacity Remote configuration and upgrade capacity Scalable number of channels Self tune capability when new wavelength channels added Any mix of services on a single card Scalable line speeds 10G to 40G, 40G to 100G and 10G to 100G 12

Line-Side and Client-Side Interfaces Depending on the implementation scenario of the SKA, the table below shows possible configurations for the line-side and client-side interfaces. Data Rates Protocols Modulation Formats Optics 10G 40G 100G SONET/SDH: OC-48/ STM-16, OC-192/ STM- 64, OC-768/ STM-256 G.709 OUT-2/-3 Gigabit and Fast Ethernet 10GE WAN/LAN PHY ESCON, FICON 10G Fibre Channel Optical DuoBinary RZ, NRZ DPSK, DQPSK RZ-DPSK, NRZ-DPSK RZ-DQPSK Coherent PMD-QPSK Coherent CP-QPSK Pluggable XFP Pluggable SFP Continued growth of bandwidth and the pressure to reduce transmission costs will lead to the need for higher bit rates, and consequently, new protocols and modulation formats. For the SKA it will not be an exception, and for that, the equipment must have specific features. 13

Line-Side and Client-Side Interfaces All the features for the line-side and client side interfaces were listed but in the following table, only some of them are described due its high number. Line-Side Features CWDM and DWDM Transport Forward Error Correction (FEC) and Enhanced FEC Coherent Detection PMD and CD tolerance and DCM free optical design 3R operation (reshape, retime, regenerate) Remote access and highly effective automation Full band tunable transponders and transceivers 10G, 40G, 100G transponders Mix of services in one card Common line cards and chassis Regenerator functionalities National, regional, metro reach Client-Side Features Multi-port, multi-protocol transponders with per-port service selectivity Multiplexing transponders to support asynchronous multiplexing Software programmable ports on the muxponders ITU application codes G.691 I-64.1 (GR- 253 SR-1) Multirate multireach client interfaces 14

A look into High transmission rates? Four main market drivers of introducing 40G into long haul systems: Bandwidth growth Reduction of Transmission Costs Need to Relieve High-Capacity Bottlenecks Support for the New Generation of IP Backbone Routers Technical Issues for 40G DWDM OSNR Sensitivity Chromatic Dispersion Polarization Mode Dispersion Forward Error Correction (FEC), Alternative Modulation Formats and Dispersion Compensation Techniques solved these issues, enabling commercial deployment of 40G technology BUT: 50% of the world internet traffic already runs on 40G servers (availability of components). 15

Caveats: 40G - Why Did It Take 10 Years for 40G To Take Off? Courtesy of NSN 16

The Four Technology Steps in 40G 17

Increasing Network Traffic Driver for 40G/100G in Core and Metro SKA? 18

Convergence: 2008 - Field Trial mixed 100G/40G/10G over 1040 km ; NSN and Verizon Experimental setup: 100G mixed with 40G and 10G over field deployed fiber, record distance 1040 Km. 100G using 50GHz compatible CP-QPSK, 40G using DPSK, 10G using NRZ. Standard chromatic dispersion map & PMD tolerance >23 ps mean DGD Courtesy of NSN ROAD M EDFA Spectra of 10G/40G/100G channels 13 x 80 km Fiber Loop ROADM ROADM World record reach of 1040 km. Mixed transmission of 100G/40G/10G on 50GHz equally spaced grid. Addressing also green power solutions 19

First pass on full SKA network configuration - Phase 1 Analysis of network behaviour and configuration dependence. Receptor is one way transmission M&C data is estimated at an additional 10Gbps bi-directional transmission/ receptor SKA1design must be SKA 2 compliant. 20

SKA Phase 1 Scenarios Several designs and measurements were made which included simulations for different distances, bit-rates and types of antennas. Here are shown the distances between the antenna base (antenna with ID = 0) and the others (dishes and AA-lo). 21

SKA Phase 1 Simulations Two different transmission Modulations were analyzed: NRZ modulation, used and sufficient for short hauls (and low-debits generically). It is usually the cheaper as it has a widespread use. CP-QPSK modulation, pointed by the industry as the next standard for long haul and high debits, provides a necessary upgrade path during the SKA lifetime. 10Gbps and 40Gbps simulation scenarios for Dishes For 10km, a single SMF fiber was used along with NRZ modulation. For 50km a DCF fiber was added in front of the SMF fiber for dispersion compensation. For 100km and 180km link simulation, DCF fibers were used to compensate for dispersion, and the links were divided in two and three spans respectively in order to amplify the signal along them. 22

SKA Phase 1 - Simulations 10Gbps and 40Gbps simulation scenarios for AA-los and PAFs Transmission required SMF and DCF fiber for dispersion compensation, given a 32 channel 40G transmission. Also here, depending on the distances of the links more than one span was used in order to reach desired results. For PAFs, a 48 channel 40G transmission system was simulated, for 10km and 100km. The scenarios were similar to the ones tested for the AA-lo. NRZ modulation format + C-Band limit the number of channels to 40 with a channel spacing of 100G. Need for alternative modulation formats and coherent detection. 23

SKA Phase 1 Simulations With this in mind, AA-lo scenario was simulated one more time, but employing DQPSK modulation format. With a suitable aggregation, it presents a very good result for the 32 channel system, and allows upgradability when aggregating more channels and higher bit-rates. In resume, the designs and measurements undertaken so far employed SMF fiber as well as DCF fiber for dispersion compensation. NRZ was the modulation format used, although for higher bit-rates and longer distances advanced modulation formats have to be applied. For this, the system must have upgrade capabilities. 24

SKA Phase 2 To realize the full SKA, SKA1 will be extended to SKA2 in many terms. One of the major differences from phase 1 is the increase in the number of antennas. 25

SKA Phase 2 Considering the addition of the 40G and the 100G scenarios, it implies an infrastructure development from the actual 10G scenarios. Scaling the system to higher bit-rates can only be successful if: The 40G and 100G transmission format is compatible with already deployed transmission links. It ensures compatibility with existing network topologies. From the previous points it can be seen that it is possible to upgrade for the next phase. Since 40G and 100G are in transition for market availability within the next years, Industry is planning equipment to be compliant with these major transmission rates. 26

Conclusions I Nonfunctional requirements: Implementation dependent Gives good knowledge of the SKA needs. Achieved a good mapping of available options Released for comments. Market mature and economically viable for 40G standard. Positive forecast for 40G/100G within SKA timeframes (possibility of SKA / AAVP field trials with exclusive 100G equipment - > at the forefront of ICT high-performance testing of Networks) Cause for cautious optimism (albeit many variables and scenarios still to be controlled/ analyzed) 27

Conclusions II Analysis will take new technology and pricing forecasts Weighting custom made needs vs industry providers capabilities. Industry is moving towards Coherent systems for long hauls. Good examples for mixed standard networks; easily upgradable and scalable. Triggered interest of major word leading industry (ex: SPDO NDA with Nokia Siemens networks) SKA phase 1 simulations and costing in the horizon. 28

Conclusions III This concept described the building blocks and related equipment in the digital data backhaul networks for Signal Transport and Networks (STAN), based on current and forecasted COTS technologies. Here we can divide the system on a fiber choice and equipment. The choice of fiber may impact upgradability scenarios, so we chose fibers whose type and quality can accommodate the SKA specifications and the expected upgrades in equipment performance during the SKA expansions phases and lifetime, according to a wide expert advice. 29

Conclusions III More specifically, and a critical aspect to the SKA stand, we analyzed the core problem as a function of a transmission capability as a result of the transmission technology roadmaps worldwide and current solutions. To source the information on the available technology and forecast the next 15 years of evolution, dedicated workshop were organized to stimulate discussion and know-how acquisition with some of the main companies like Erickson, Cisco and Nokia Siemens. 30

31