Planning and Installing the EnergyAxis System Starter Kit. Introduction. Related Documents

Similar documents
4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

ALPHA meter. General. Installation instructions IL S

A1800 ALPHA meter special installation instructions DANGER

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

Arc Sensor User Manual

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

Elster and EnergyAxis at the Confluence of AMI and DR

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

INSTRUCTION LEAFLET IL17537B F FRAME IQ ENERGY SENTINEL TM INSTALLATION INSTRUCTIONS FOR F FRAME IQ ENERGY SENTINEL TM

COOPER POWER SERIES. Upgrade instructions for CL-6 series control firmware. Voltage Regulators MN225071EN

Reference Guide & Test Report

AN12082 Capacitive Touch Sensor Design

Sheet Metal Design Guidelines

SureCall TM CM800 65dB

Uplink 5500EZ. Installation and User Guide. S e pte m be r 1 2,

OWNER S MANUAL: Adjustable Height Wall Rack

X80 Activator. User's Manual. Version 1.1.

AN Extended Range Proximity with SMSC RightTouch Capacitive Sensors

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

Fiber Optic Expansion Interface

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol. Software Version v2.03 SRM009FVAE0808

Taurus CP-300 Single Pump

B (bottom) Package type descriptive code. VFBGA176 Package style descriptive code

TN ADC design guidelines. Document information

AN Replacing HMC625 by NXP BGA7204. Document information

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

4 Maintaining Accuracy of External Diode Connections

RFTX-1 Installation Manual

UM GreenChip TEA1995DB1295 synchronous rectifier controller demo board. Document information

3 Light Fiber Products

R_ Driving LPC1500 with EPSON Crystals. Rev October Document information. Keywords Abstract

Antenna Design Guide

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

SOT Package summary

UM DALI getting started guide. Document information

Nashville Etagere/Bookcase

Light Pipe. Series LPS100, LPS150, and LPS250. Product Bulletin LPS Release A, Effective January Table of Contents

This application note assumes that the reader has previous knowledge of how temperature sensing is performed using diode-connected transistors.

MATRIX 430. Entry level guidance Software version 1.03

Field Hub Installation Guide. P/N Rev. C 05/15

AN UCODE I2C PCB antenna reference designs. Application note COMPANY PUBLIC. Rev October Document information

MaxLite LED Self-Driven LiteBars

Machining Design Guidelines

D (double) Package type descriptive code. SC-73 Package type industry code. SC-73 Package style descriptive code

00108/00110 INSTRUCTION MANUAL

BFU550XR ISM 433 MHz LNA design. BFU520, BFU530, BFU550 series, ISM-band, 433MHz 866MHz Abstract

AN TEA1892 GreenChip synchronous rectifier controller. Document information

ANTENNA DESIGN GUIDE. Last updated February 11, The information in this document is subject to change without notice.

UM DALI getting started guide. Document information

Rough-In Frame OVERVIEW OF INSTALLATION PROCEDURE PLANNING GUIDE MODEL IR-105 INSTALLATION DON'TS

E3X-DRT21/SRT21/CIF11

TED-Kit 2, Release Notes

Model 935A Current Source Operation Manual

Sheet Metal Design Guidelines

SKY LF: MHz Low-Noise Power Amplifier Driver

Warranty Information. UPHOLSTERED FURNITURE Leather and Fabric. CASEGOODS And Occasional Furniture

D (double) Package type descriptive code. SMA; PMOS Package type industry code. SMA; PMOS Package style descriptive code

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer

SOT1688-1(SC) 1 Package summary

D (double) Package type descriptive code TSSOP8. TSSOP (thin shrink small outline package) Package body material type

D (double) Package type descriptive code XSON16. P (plastic) JEDEC package outline code. MO-252 Mounting method type

D (double) Package type descriptive code VSSOP8. P (plastic) JEDEC package outline code. MO-187 Mounting method type

Developing the Model

PN7120 NFC Controller SBC Kit User Manual

Broadband Step-Up Transformer. User Manual

Initial Comments on DRI Application for Wakeby Road Cell Tower September 26, 2017

PTN5100 PCB layout guidelines

SKY LF: GHz Seven-Bit Digital Attenuator with Serial and Parallel Drivers

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

Single Flex and Double Flex Couplings (i)

orientation Conergy SunTop Instructions for professional installation

POWER TRACE TM TASCO, INC.

MN E. Waveform Viewer: Power Xpert Software 2.2

Vinyl Fence Gates. Assembly and Installation Instructions PLEASE READ OWNER'S MANUAL COMPLETELY BEFORE ASSEMBLING YOUR FENCE.

ANTENNA DESIGN GUIDE. Last updated March 8 th, The information in this document is subject to change without notice.

HVQFN (thermal enhanced very thin quad flatpack; no leads) P (plastic) MO-220 S (surface mount) Issue date Manufacturer package code

B. The designated coverage areas shall include both indoor and outdoor coverage.

plastic ball grid array package; 426 balls B (bottom) Package type descriptive code BGA426 Package type industry code

SKY LF: 0.1 to 3.0 GHz SP8T Antenna Switch

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

Sheet Metal Design Guidelines

PBM-UNI Installation Guide

TDA18250HN. 1. General description. 2. Features and benefits. Cable Silicon Tuner

Ambient Weather WS-40 Wireless Indoor / Outdoor Thermometer

DEMO MANUAL DC2349A LTC5586 6GHz High Linearity I/Q Demodulator with Wideband IF Amplifier DESCRIPTION BOARD PHOTO

User Manual January Opticom Infrared System RC790 Remote Coding Unit

Using BCM Bus Converters in High Power Arrays

NPN 5 GHz wideband transistor. The transistor is encapsulated in a 3-pin plastic SOT23 envelope.

TRANSDUCER IN-LINE AMPLIFIER

AFF756. MagnetoResistive Field Sensor DATA SHEET

UM TEA1721 universal mains white goods flyback SMPS demo board. Document information

Q (quad) Package type descriptive code. SQFP240 Package type industry code. SQFP240 Package style descriptive code

D (double) Package type descriptive code SO8. SO (small outline) Package body material type. P (plastic) IEC package outline code

Transcription:

November 003 IL4-4030A Planning and Installing the EnergyAxis System Starter Kit Introduction This instructional leaflet provides guidelines for installing the EnergyAxis System starter kit, composed of s and A3 ALPHA meter/collectors (A3 ALPHA meters with ITM3 1 and ILC1 option boards). Both the s and the A3 ALPHA meter/collectors use 900 MHz radios to communicate with each other in a wireless local area network (LAN). The collector s ITM3 can be used in conjunction with Elster Electricity s Metercat meter support software to remotely read billing data for a collector as well as billing data for all s that are registered to the collector. The starter kit is intended to demonstrate the following characteristics: ƒ The system is easy to install and does not require any additional infrastructure other than the meters. ƒ Planning the system is relatively easy. ƒ The system provides reliable meter readings. A typical starter system consists of the following: ƒ up to three Form S A3 ALPHA meter/collectors ƒ up to 500 Form S s ƒ Metercat Release 1.4 or above ƒ a marriage file used to associate a serial number with a LAN identification number Related Documents The following documents provide details on using the various components necessary for operating the system: ƒ Elster Electricity Modems Product Guide (PG4-1006A) ƒ A3 ALPHA Meter/Collector Product Guide (PG4-1005A) ƒ EnergyAxis System Starter Kit Software User Guide ƒ Metercat Quick Start Guide Refer to the respective technical manuals and instructional leaflets (IL) for details on the A3 ALPHA meter and the. internal telephone modem internal LAN controller 1

IL4 4030A November 003 LAN Overview The collector contains most of the network intelligence required to register s and operate the LAN. Specifically, the collector is responsible for the following: ƒ determining an optimal communications path for each and registering a to this communications path ƒ reading and storing billing data from each on a periodic basis (the evaluation collectors will be configured to read billing data from each every four hours) ƒ synchronizing the s to the system time ƒ distributing TOU schedule information to each (allowing the s to perform TOU metering) Note: TOU schedules must be programmed in the collector at time of manufacture. Each will be registered to only one collector at a time. Once registered, REX meters may change their registration to a different collector if a shorter, reliable communications path is found to the different collector. The 900 MHz network can be described as a mesh network because any is allowed to communicate with any other to route communications to and from the collector (Figure 1). The 900 MHz network can function out to eight levels (seven levels of repeaters) as illustrated in Figure 1. A meter that communicates directly to the collector is referred to as a level 1 meter; a meter that communicates to the collector through one repeater is a level meter, and so on. A3 ALPHA meter/collector Communication path Meter Level 8 7 6 5 4 3 1 Figure 1 REX network showing all possible communications paths

November 003 IL4 4030A A3 ALPHA meter/collector Communication path Meter Level 8 7 6 5 4 3 1 Figure REX network showing registered communications paths As the density of meters in an area is increased, each meter will have an increased number of possible communications paths to the collector. When installed, the collector qualifies and selects a communications path for each (Figure ). The collector monitors the communications performance of each meter and will change the communications paths for meters that fall below a required performance threshold. The radio frequency (RF) signals transmitted and received by a meter are directly affected by the meter socket and the building structure. As a result, communication from the face of the meter tend to be better than communication through the back of the meter. Elster Electricity field testing indicates that meters facing away from each other can reliably communicate if they are within 400 feet of each other (Figure 3). In the optimal case where meters are on residences facing each other, meters can typically communicate reliably if they are within 1500 feet of each other. In general, as the distance between these devices increases, the communications performance between the two decreases. Although not typical, field testing has shown reliable communications performance between devices that are 000 or more feet apart. < 400 ft. 1500 000 ft. Figure 3 Meter orientation, distance and RF performance 3

IL4 4030A November 003 Note: An increased communications distance between meters does not necessarily mean that the system will not work. It means that more communications attempts may be required to obtain a given reading. Installation of the Starter Kit Selecting a Site When selecting a site for the system, consideration should be given to the density of meters within the area. As described above, the network will work best if each meter has multiple meters within communications range. With this in mind, Elster Electricity recommends the following guidelines when selecting an area for the system: ƒ apartment complexes, town houses, and other densely populated areas should work very well ƒ areas with single-family homes with lot sizes smaller than 0.35 acres should work very well (s do not need to be installed at every possible location for the system to work well) ƒ when the lot size is above 0.5 acres (or where the typical distance between meters is greater than 500 feet) it is more critical that s be installed at all possible meter locations thereby giving each meter as many communications paths as possible Collector Coverage Area For planning purposes, Elster Electricity recommends using a 500-foot diameter circle to represent the collector coverage area. With a collector centrally located in the center of this circle, the collector should be able to register all s inside the circle to a meter repeater level of four or less. With a total of eight levels available, there should be ample margin for signal overlap between collector cells. This guideline is consistent with the planning philosophy of providing multiple paths to each meter. Collector Location (General) After selecting a site for the network, the next step is to select the locations for the collectors. Using a detailed map of the area, use a compass to draw 500-foot diameter circles to indicate the collector coverage area. If one collector is used, the collector should be in the center of the area of the selected site. If multiple collectors are used, the edges of the first collector circle (or cell) should touch on natural boundaries of the selected site (such as major roads or open areas) or should touch the boundaries of the selected site. After locating the first collector, additional collector cells can be drawn such that neighboring cells touch one point of the first collector cell (Figure 4). 4

November 003 IL4 4030A Figure 4 Collector cell coverage (3 cells) Collector Location (Specific) After selecting a general location for the collector, the actual location will need to be selected. An ideal collector site will have: ƒ access to a dedicated phone line (required) ƒ houses on all four sides ƒ reasonable maintenance access Installation Sequence For the starter system, Elster Electricity recommends the following process: 1 Install all of the s that are part of the system. Install the collectors that are part of the system. Once installed, the collector will begin the process of finding and registering s. By installing all of the s first, the collector will be able to select communications paths based on all combinations and will therefore build the most reliable communications network. Example System Installation: Elster Electricity Field Trial A 7 point 900 MHz network field trial (see Figure 5) has been operating in a residential neighborhood since August 00. This field trial of collectors and meters was used to test the network and equipment in an actual working environment. All meters were installed using dual socket adapters with a standard electromechanical meter at the top for manual reading and a at the bottom for testing purposes. Not every home in the area had a installed; several of the planned sites would not accommodate dual adapter arrangements and had to be eliminated from the test. The test environment is a residential neighborhood with lot sizes of approximately 0.5-0.5 acre (373 746 sq. ft.). The total area of the test site is about half a square mile. The neighborhood is 10-15 years old and characterized by long established trees, shrubs and other foliage. Home construction is conventional wood frame housing with a variety of exterior finishes (for example, brick, vinyl, aluminum and cedar siding). 5

IL4 4030A November 003 Test Site Specifications The REX field test layout is 0.5 miles by 0.6 miles and the individual lots are approximately 15 feet square on average. That corresponds to a lot size of approximately 0.35 acres and means the distance between meters on adjacent lots typically ranges from 50-50 feet. The 50 foot distance results when meters are on the closest sides of two houses and the 50 foot distance results when meters are on the far sides of two houses, on the front of one house and back of another or on houses that are across the street from each other. Figure 5 900 MHz network field test site 6

IL4-4030A November 003 The field trial installation was made with three collectors at different extremes of the neighborhood (represented by stars in Figure 5) with s located throughout the neighborhood (represented by the dark gray shaded locations in Figure 5). This allowed the system to be operated with one, two or three collectors active at any one time and was used to investigate a variety of operating scenarios. All these test conditions have been exercised thoroughly since the system was first installed. The entire 7 meter site has been successfully operated as a single cell from each of the individual collectors. These tests confirmed the multi-level repeater concept, the collector s network algorithms and the ability of the mesh concept to reach every device in the neighborhood from the diverse collectors. The site has also been operated with two collectors active (two cells) and with all three collectors (three cells) active at one time. In these tests, each of the collectors claimed a segment of the total population with the cells overlapping in several areas (represented by arcs in Figure 5). Communications testing verified that system performance was equally successful for the one, two, and three collector configurations. Additional Meter Information A3 ALPHA meter/collectors are available as Form 1S, S, 3S, 4S, 5S, 9S, 1S, 16S and 35S meters. s are available for residential sites that require Form 1S, S, 3S and 4S devices. DISCLAIMER OF WARRANTIES AND LIMITATIONS OF LIABILITY There are no understandings, agreements, representations, or warranties either expressed or implied, including warranties of merchantability or fitness for a particular purpose, other than those specifically set out by any existing contract between the parties. Any such contract states the entire obligation of the seller. The contents of this document shall not become part of or modify any prior existing agreement, commitment, or relationship. The information, recommendations, descriptions, and safety notices in this document are based on Elster Electricity, LLC experience and judgment with respect to operation and maintenance of the described product. This information should not be considered as allinclusive or covering all contingencies. If further information is required, Elster Electricity, LLC should be consulted. No warranties, either expressed or implied, including warranties of fitness for a particular purpose or merchantability, or warranties arising from the course of dealing or usage of trade, are made regarding the information, recommendations, descriptions, warnings, and cautions contained herein. In no event will Elster Electricity, LLC be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to: damage or loss of use of equipment, cost of capital, loss of profits or revenues, or claims against the user by its customers resulting from the use of the information, recommendations, descriptions, and safety notices contained herein. Elster Electricity, LLC Raleigh, North Carolina USA +1 800 338 551 (US toll free) +1 919 1 4800 support@elsterelectricity.com www.elsterelectricity.com *IL4-4030A* 003 by Elster Electricity, LLC All rights reserved. Printed in the United States