Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

Similar documents
Horizontal Shaft Wall

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337

Plasterboard Ceiling Systems

GlasRoc Sheathing Type X

Finishing Plasterboard

rondo exangle drywall finishing sections

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

INTERNAL LININGS INSTALLATION GUIDE

Pitched roofs rafter level

System for 2+ Level Buildings

GUIDE. Elephant INSTALLATION. Elephant Plasterboard Installation Guide August

June Residential Refurbishment Pitched roofs - rafter level

4256HM JAMES HARDIE MONOLITHIC CLADDING

KS SERIES - VERTICAL INSTALLATION

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter

Chapter 1. Beam and Sill Plates

INSTALLATION MANUAL STORAGE

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

June Non - Residential Refurbishment Pitched roofs - rafter level

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

A Shell construction

4.0 GENERAL WALL AND CEILING INSTALLATION

INTUBATT FLOOR/CEILING SYSTEM & BOXOUT SYSTEM FOR FRL 120/120/120 RISF 120 INSTALLATION GUIDE

FASTENERS BUILDING DEPARTMENT

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT


DW HORIZONTAL INSTALLATION

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Dura-Lock Roof System

WALL TO FABRICATED FLOOR

Timber joist. Timber joist ceilings and separating / compartment floors. Timber joist.

Installation Instructions

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

GENERAL INSTALLATION GUIDELINES

Drywall, Wood and Truss Uplift

GENERAL INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS for TB6.2,TB7.0, TB7.8 & TB8.4

Method of Build 1. Fire. Sound

SECTION ROUGH CARPENTRY

26- H i n g e d P a t i o D o o r s - I n s w i n g

Definitions and Design Considerations... W-CR-2

CFDTT-01. Control Joint Study (General)

Arriva. Concealed frame doorsets. Installation instructions

EzyBrace Systems. Specification and installation manual CBI 5113

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

ASS 70 FD folding / sliding door. Installation Guide

Before installation, check your local and state requirements for this type of install.

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

WHY YOU SHOULD USE TUFFLOOR. components

Installation Instructions and Ordering Information

Sound insulating floor system

UCO Vistabord Fixing Manual

Sam Keung Regional Manager (BU Fire Protection), Hilti Corporation February, 2018 Sydney

GLOSSARY OF TERMS SECTION 8

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

Folding Sliding door system

Installation Instructions

Method of Build 1. General

03/05. CI/SfB (22) scion. The beauty of natural wood

August 2008: Issue 1. Non - Residential New Build Pitched Roofs - Rafter Level

Installation Guide. WarmCore. Folding Sliding door system. Glass Packing. Pre-Installation. Removing the Existing Door.

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Side Light Frame Pack Assembly Instructions

window installation Guide wood FRaMinG New Construction

How To Install Windows: Nail-Fin Application

Site Installation Guide

Steel Sound Enclosure

Integrity Polygon and Round Top Installation and Finishing Instructions

Series Exterior glazed curtain wall. Installation Instructions

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Side Light Frame Pack Assembly Instructions

Pebbletex Adhered Mat Design. Typical Details

BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Flashing Materials. Rough Opening Preparation

FireCase. Frameless structural steel encasement system. FireCase.

14 Intex Price Guide. Suitable for use in Fire Rated Wall Systems

Site Preparation Information for:

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Sound insulating floor system

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Series Advanced and alternate. Installation Instructions

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

PINEHAVEN SHEDS Assembly Instructions FOR LEAN-TO SHEDS

Featuring TJ Rim Board and TimberStrand LSL

Pyroscat Duct Wrap Single Layer Installation

Acceptable Standards of Domestic Construction

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

ASS 70 FD folding/sliding door installation guide

Steel Reinforced Joining Guide (Horizontal / Vertical)

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

KS42 MF SERIES - HORIZONTAL INSTALLATION

Transcription:

SYSTEMS 210 INSTALLATION 211 GENERAL REQUIREMENTS 211 FRAMING 212 PLASTERBOARD LAYOUT 213 PLASTERBOARD FIXING 214 CONSTRUCTION DETAILS 217 Shaft Wall Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts. Shaft Wall systems are ideal when constructing a wall where access is only possible from one side. This side is referred to as the storey side. Shaft Wall has advantages compared with masonry construction: 75% lighter Thinner typically less than 100mm wide using 64mm CH-Studs No wet trades required Faster installation no scaffolding is required inside the shaft. 209

3.3.1 Systems Fire Rated KSHW1 WALL LINING: [Side 1] 1 layer of 16mm FireShield [Side 2] 1 layer of 25mm ShaftLiner encased in CH-studs FRAME: Shaft Wall CH-steel studs at maximum 600mm centres [16mm FireShield can be substituted with 16mm TruRock] FRL /60/60 rated from both sides Fire Report FAR 2863 CH-Stud Size (mm) CH-Stud Depth 64 102 CH-Stud BMT Max Height (m) Non-Load Bearing Studs at 600mm UDL 0.25kPa Non-Load Bearing Studs at 600mm UDL 0.35kPa 0.55 2.95 2.64 0.9 3.46 3.09 0.55 3.73 2.66 0.9 4.98 4.19 Width (mm) Sound Insulation for studs at 600mm centres and thinnest BMT Rw (Rw + Ctr) No Insulation 50mm EarthWool 11 kg/m³ 60mm Polyester ASB3 80 39 (32) 46 (39) 46 (38) 118 42 (33) 48 (41) 48 (41) Acoustic Report Day Design 3094-18 KSHW2 WALL LINING: [Side 1] 2 layers of 16mm FireShield [Side 2] 1 layer of 25mm ShaftLiner encased in CH-studs FRAME: Shaft Wall CH-steel studs at maximum 600mm centres [16mm FireShield can be substituted with 16mm TruRock] FRL /120/120 rated from both sides Fire Report FAR 2863 CH-Stud Size (mm) CH-Stud Depth 64 102 CH-Stud BMT Max Height (m) Non-Load Bearing Studs at 600mm UDL 0.25kPa Non-Load Bearing Studs at 600mm UDL 0.35kPa 0.55 3.73 2.66 0.9 4.38 3.89 0.55 3.73 2.66 0.9 5.51 4.19 Width (mm) Sound Insulation for studs at 600mm centres and thinnest BMT Rw (Rw + Ctr) No Insulation 50mm EarthWool 11 kg/m³ 60mm Polyester ASB3 96 44 (36) 50 (42) 50 (42) 134 46 (37) 52 (46) 52 (46) Acoustic Report Day Design 3094-18 KSHW3 WALL LINING: [Side 1] 1 layer of 16mm FireShield [Side 2] 1 layer of 25mm ShaftLiner encased in CH-studs and 1 layer of 16mm FireShield FRAME: Shaft Wall CH-steel studs at maximum 600mm centres [16mm FireShield can be substituted with 16mm TruRock] FRL /120/120 rated from both sides Fire Report FAR 2863 CH-Stud Size (mm) CH-Stud Depth 64 102 CH-Stud BMT Max Height (m) Non-Load Bearing Studs at 600mm UDL 0.25kPa Non-Load Bearing Studs at 600mm UDL 0.35kPa 0.55 3.73 2.66 0.9 4.38 3.89 0.55 3.73 2.66 0.9 5.51 4.19 Width (mm) Sound Insulation for studs at 600mm centres and thinnest BMT Rw (Rw + Ctr) No Insulation 50mm EarthWool 11 kg/m³ 60mm Polyester ASB3 96 42 (35) 50 (42) 50 (42) 134 45 (36) 52 (45) 52 (45) Acoustic Report Day Design 3094-18 210 Technical Advice 1300 724 505 knaufmetal.com.au

General Requirements 3.3.1 Installation General Requirements Fire Rated Install control joints in walls: At 12m maximum intervals At all control joints in the structure At any change in the substrate material. Only joint the face layer. As a minimum to achieve the FRL, only use paper tape and: Two coats of MastaBase/MastaLongset, or Three coats of MastaLite. Use approved fire rated penetration details. Fire penetrations may require fire collars or other devices to maintain fire performance. Use fire sealant on all gaps and around perimeter, vermiculite plaster is not permitted. For acceptable modifications or variations to fire rated systems. [Refer to 2.3 Fire Resistance] Technical Advice 1300 724 505 knauf.com.au 211

3.3.1 Installation Framing Framing Fire Rated Fix the bottom track and top track or deflection head at imum centres and 100mm maximum from each end. Use a deflection head if: Wall heights are 4800mm or greater Ceiling, roof or floor movement is expected. Space CH-Studs at 600mm centres maximum. Push CH-Studs down completely into bottom track. Friction fit all CH-Studs. They must not be screwed to the top and bottom tracks. Plumbing and electrical services must not protrude beyond the face of the stud. 38mm 19mm CH-Stud 0.55mm BMT and 0.9mm BMT (Rondo No.570 or No.590) 64 or 102mm E-Stud 0.55mm BMT (Rondo No.574 or No.594) 64 or 102mm 25mm 25mm 35mm FIGURE 1 Shaft Wall CH-Stud 25mm FIGURE 2 Shaft Wall E-Stud 64 or 102mm 57mm Bottom J-track and End Stud J-track 0.8mm BMT (Rondo No.578 or No.598) 75mm 50mm 25mm Deflection Head J-track and Jamb Stud 0.8mm BMT (Rondo No.579 or No.599) 64 or 102mm FIGURE 3 Shaft Wall J-Track FIGURE 4 Shaft Wall Deflection Head J-Track 212 Technical Advice 1300 724 505 knaufmetal.com.au

Plasterboard Layout 3.3.1 Installation Plasterboard Layout CH-stud Deflection head J-track / top J-track End stud J-track 2 10 11 9 8 7 6 5 4 3 1 Bottom J-track E-stud 25mm ShaftLiner Fold flange of J-track 60mm to install last ShaftLiner FIGURE 5 Shaft Wall Construction Sequence Perspective Stagger butt joints in ShaftLiner to upper and lower third of wall. Stagger butt joints between adjoining sheets Use CH-stud horizontally along butt joint in ShaftLiner FIGURE 6 ShaftLiner Butt Joint Layout Perspective Technical Advice 1300 724 505 knauf.com.au 213

3.3.1 Installation Plasterboard Layout and Fixing Plasterboard Layout Fire Rated FireShield Horizontal Layout Stagger butt joints by 600mm minimum on adjoining sheets and between layers. Stagger recessed edges by 300mm minimum between layers. First layer butt joints must be backed by a CH-stud. FireShield Vertical Layout Stagger butt joints by 600mm minimum on adjoining sheets and between layers. Stagger recessed edges by 300mm minimum between layers. First layer butt joints must be backed by a nogging. ShaftLiner Layout If the wall height exceeds the length of ShaftLiner, position the ShaftLiner butt joints within the upper and lower third of the wall. [Refer to Figure 6] Stagger ShaftLiner butt joints for adjacent panels and reinforce with horizontal CH-stud cut to fit between the vertical studs. [Refer to Figure 6] Install FireShield horizontally when practical to reduce the effect of glancing light. Minimise butt joints by using long sheets. Plasterboard Fixing Fire Rated Use the Screw Only Method. Stud adhesive is not permitted. Drive screws to just below the sheet surface, taking care not to break the paper linerboard. Laminating screws can be used to fix butt joints in the second layer. SCREW TYPE AND MINIMUM SIZE FOR THE INSTALLATION OF PLASTERBOARD TO STEEL Plasterboard Thickness 1st Layer 2nd Layer 3rd Layer 16mm FireShield 30mm screw 45mm screw* 65mm screw* 25mm ShaftLiner 45mm screw + For steel 0.75mm BMT minimum 6g fine thread needle point screws. For steel 0.75mm BMT minimum 6g fine thread drill point screws. *38mm 10g Laminating screws may be used as detailed in installation diagrams. + Use for securing ShaftLiner to J-track when the J-track is being used as an end stud. 214 Technical Advice 1300 724 505 knaufmetal.com.au

Plasterboard Fixing 3.3.1 Installation FIGURE 7 Fire Rated 1 Layer Horizontal Screw Only Method Butt Joints Fix at 200mm max centres. Stagger by 600mm min on adjoining sheets Butt Joints Fix on a stud or alternatively, float between studs using 51mm min track Plasterboard must not be fixed to head track Sheet Edges Fix screws 10-50mm Sheet Edges from sheet edges Fix screws 10-50mm except at head and from sheet edges base tracks except at head and base tracks 200mm min Sealant Use Knauf Bindex Fire and Acoustic Sealant on all gaps and around perimeter to maintain fire and acoustic integrity Fix on each stud 60-100mm 200mm max 150mm min 10-50mm Jointing Only joint the face layer. As a minimum, use paper tape with either two Jointing Only joint the face layer. As a coats of MastaBase/MastaLongset or minimum, use paper tape with either two three coats of MastaLite. Alternatively use coats of MastaBase/MastaLongset or Knauf Bindex Fire and Acoustic Sealant three coats of MastaLite. Alternatively use according to the Tech Data Sheet. Knauf Bindex Fire and Acoustic Sealant according to the Tech Data Sheet. Field Web of track Fix on each stud 50mm FIGURE FIGURE 8 Fire 8 Rated Fire Rated 2 Layers 2 Layers Horizontal - Horizontal + Horizontal + Horizontal Screw Only Method Butt Joints butt joints must be fixed at centres and backed by a stud, or alternatively back with 51mm min track Floating butt joint backed with 51mm Floating butt joint min track backed with 51mm min track Recessed Edges Fix 1st and recessed edges on each stud. Stagger recessed edges by 300mm min between layers. Web of track Corners Field 600mm max Corners Corners Plasterboard must not be fixed to head track Sheet Edges Fix screws 10-50mm from sheet edges except at head and base tracks Openings Openings vertical screw spacing vertical screw spacing Sealant Use Knauf Bindex Fire and Acoustic Sealant on all gaps and around perimeter to maintain fire and acoustic integrity Fix on each stud 60-100mm Sheet Edges Fix screws 10-50mm from sheet edges except at head and base tracks 10-50mm floating butt joint Stagger butt joints by 300mm min between layers Stagger recessed edges by 300mm min between layers Openings vertical screw spacing Field Corners Openings vertical screw spacing Butt Joints. Fix on a stud at 200mm max centres. Alternatively, float butt joints and laminate to using laminating screws at 200mm max centres. Fix on each stud 50mm Jointing Only joint the face layer. As a minimum, use paper tape with either two coats of MastaBase/MastaLongset or three coats of MastaLite. Alternatively use Knauf Bindex Fire and Acoustic Sealant according to the Tech Data Sheet. Technical Advice 1300 724 505 knauf.com.au 215

3.3.1 Installation Plasterboard Fixing FIGURE 9 Fire Rated 1 Layer Vertical Screw Only Method Recessed Edges Fix at centres Recessed Edges must be backed by a stud Plasterboard must not be fixed to head track Field Sheet Edges Fix screws 10-50mm from sheet edges except at head and base tracks Sealant Use Knauf Bindex Fire and Acoustic Sealant on all gaps and around perimeter to maintain fire and acoustic integrity 200mm min Fix on each stud 60-100mm Butt Joints Fix at 200mm max centres and stagger screws. Butt joints must be backed by a nogging 10-50mm Butt Joints Stagger by 300mm min on adjoining sheets 300mm max Corners Openings vertical screw spacing Jointing Only joint the face layer. As a minimum, use paper tape with either two coats of MastaBase/MastaLongset or three coats of MastaLite. Alternatively use Knauf Bindex Fire and Acoustic Sealant according to the Tech Data Sheet. Fix on each stud 50mm FIGURE 10 Fire Rated 2 Layers Vertical + Vertical Screw Only Method Butt Joints Laminate to 1st layer using laminating screws at 200mm max centres. Alternatively, fix to nogging at 200mm max centres. Recessed Edges Fix at centres. recessed edges must be backed by a stud Field screw spacing Stagger recessed edges by 300mm min between layers 600mm max 10-50mm Plasterboard must not be fixed to head track Field Sheet Edges Fix screws 10-50mm from sheet edges except at head and base tracks Butt Joints butt joint must be backed by a nogging. Fix at centres. Stagger butt joints by 300mm min on adjoining sheets and between layers. Sealant Use Knauf Bindex Fire and Acoustic Sealant on all gaps and around perimeter to maintain fire and acoustic integrity Fix on each stud 60-100mm Openings screw spacing Recessed Edges Fix at centres. recessed edges must be backed by a stud. Fix on each stud 50mm Corners Jointing Only joint the face layer. As a minimum, use paper tape with either two coats of MastaBase/MastaLongset or three coats of MastaLite. Alternatively use Knauf Bindex Fire and Acoustic Sealant according to the Tech Data Sheet. 216 Technical Advice 1300 724 505 knaufmetal.com.au

FIRE RATED HEAD AND BASE DETAILS FIRE RATED HEAD AND BASE DETAILS Construction Details 3.3.1 Details 25mm clearance to ShaftLiner and pack with fire resisting mineral wool 10mm clearance to CH-Stud and 25mm clearance to ShaftLiner and pack with fire resisting mineral wool 10mm clearance to CH-Stud and Fix J-track to slab at centres and 100mm max from ends Fix 50mm from sheet top. Do not fix through track Do not fix through top track Fix J-track to slab at centres and 100mm max from ends Fix 50mm from sheet top. Do not fix through track Shaft Side Storey Side Shaft Side Storey Side FIGURE 11 Shaft Wall Head to Slab System KSHW2 FIGURE 12 Shaft Wall Head to Slab Systems KSHW1 and KSHW3 Shaft Side Storey Side Shaft Side Storey Side Fix bottom J-track to slab at centres and 100mm max from ends Push CH-studs down completely into J-track Fix bottom J-track to slab at centres and 100mm max from ends Push CH-studs down completely into J-track Fix 50mm from sheet bottom. Do not fix through J-track Fix 65mm from sheet bottom. Do not fix through J-track Fix 50mm from sheet bottom. Do not fix through track 5-10mm clearance to 5-10mm clearance to FIGURE 13 Shaft Wall Head to Base System KSHW2 FIGURE 14 Shaft Wall Head to Base Systems KSHW1 and KSHW3 Technical Advice 1300 724 505 knauf.com.au 217

3.3.1 Details Construction Details FIRE RATED SECTION DETAILS FIRE RATED SECTION DETAILS 25mm clearance to ShaftLiner and pack with fire resisting mineral wool Fix deflection head J-track to slab at 600mm max centres and 100mm max from ends 20mm clearance to CH-stud and Fix 50mm from sheet top. Do not fix through track Fix bottom J-track to beam at centres and 100mm max from ends Use this detail when wall exceeds maximum height limit of studs. or ShaftLiner used to fire protect structural beam. Beam must have load bearing FRL equal or greater than non-load bearing FRL of wall. [Refer to 3.6.3 for details] Push CH-studs down completely into J-track Fix 50mm from sheet bottom. Do not fix through J-track 5-10mm clearance to FIGURE 15 Shaft Wall Deflection Head to Slab Structural beam 50mm min Fire resistant spray Steel plate 200mm max Structural beam to support wall above 25mm clearance to ShaftLiner and pack with fire resisting mineral wool Fix J-track to beam at centres and 100mm max from ends 10mm clearance to CH-Stud and Fix 50mm from sheet top. Do not fix through track FIGURE 16 Shaft Wall to Supporting Beam FIGURE 17 Shaft Wall to Structural Beam Structural beam Fire resistant spray Track notched and riveted to CH-Stud FIGURE 19 Butt Joint in ShaftLiner Laminating screws FIGURE 18 Shaft Wall to Structural Beam FIGURE 20 Butt Joint in Fire Rated Plasterboard 218 Technical Advice 1300 724 505 knaufmetal.com.au

FIRE RATED PLAN DETAILS FIRE RATED PLAN DETAILS Construction Details 3.3.1 Details Use masonry fixings at centres vertically and 100mm max from ends CH-studs at J-track CH-stud 600mm centres E-stud 100mm max Optional stopping angle Fire sealant required to maintain fire and acoustic integrity FIGURE 21 Shaft Wall Plan 5-10mm clearance to Fix together using 10g screws at centres vertically, and 100mm max from ends 100mm max E-stud E-stud FIGURE 22 Shaft Wall Corner Plan FIGURE 23 Shaft Wall Corner Plan Fix toggle bolts at 600mm max centres vertically, and 100mm from ends 100mm max CH-stud Fix toggle bolts at centres vertically, and 100mm from ends E-stud FIGURE 24 Shaft Wall Intersecting Wall Plan FIGURE 25 Shaft Wall Intersecting Wall Plan For internal and external corners, fill gaps with either Knauf Bindex Fire and Acoustic Sealant or Mastabase jointing compound. Fill any other gaps with Knauf Bindex Sealant to maintain integrity. Technical Advice 1300 724 505 knauf.com.au 219

3.3.1 Details Construction Details FIRE RATED SHAFT FIRE RATED WALL CONTROL JOINT AND OPENING DETAIL FOR ACCESS PANEL OR FIRE DAMPER CONTROL JOINT AND OPENING DETAIL FOR ACCESS PANEL OR FIRE DAMPER Backing tape 15mm E-stud Tracks discontinuous over control joint 22mm backing rod Fire sealant depth same as the Optional control joint bead thickness to maintain fire and acoustic integrity FIGURE 26 Shaft Wall Control Joint Plan CH-Stud Header ShaftLiner 25mm ShaftLiner or 2 x 16mm FireShield around opening Opening for access panel or damper. Jamb stud Refer to access panel / fire damper manufacturer for specific installation detail of the proprrietry item. The item installed in the opening must maintain the FRL of the system. Refer to framing manufacturer for the design of the jamb, header and sill. Actual framing members for the opening are dependant on the wall height, size of the opening, lateral wind pressure, and the deflection limit criteria. Fire rated Elevation Sill FIGURE 27 Opening Detail For Fire Damper or Access Panel Fire rated from both directions but built from one side only Fill any gaps with fire sealant to maintain fire and acoustic integrity. 220 Technical Advice 1300 724 505 knaufmetal.com.au