Standard Recovery Diodes Generation 2 DO-5 (DO-203AB) (Stud Version), 95 A

Similar documents
Standard Recovery Diodes, Generation 2 DO-5 (Stud Version), 80 A

Standard Recovery Diodes, Generation 2 DO-5 (DO-203AB) (Stud Version), 80 A

VS-85HF(R), VS-86HF(R), VS-87HF(R), VS-88HF(R) Series Standard Recovery Diodes, (Stud Version), 85 A

Standard Recovery Diodes (Stud Version), 12 A

Standard Recovery Diodes (Stud Version), 400 A

Standard Recovery Diodes, (Stud Version), 40 A

Standard Recovery Diodes, (Stud Version), 85 A

Standard Recovery Diodes (Stud Version), 150 A

Standard Recovery Diodes (Stud Version), 300 A

Standard Recovery Diodes (Stud Version), 70 A

Standard Recovery Diodes, (Stud Version), 200 A

Power Rectifier Diodes (T-Modules), 2200 V, 20 A

Standard Recovery Diodes, (Stud Version), 300 A

Standard Recovery Diodes, (Stud Version), 400 A

Standard Recovery Diodes, 400 A

Standard Recovery Diodes, (Stud Version), 85 A

Fast Recovery Diodes (Stud Version), 40 A, 70 A, 85 A

VS-1N1183, VS-1N3765, VS-1N1183A, VS-1N2128A Series Power Silicon Rectifier Diodes, (Stud Version), 35 A, 40 A, 60 A

VS-1N1183, VS-1N3765, VS-1N1183A, VS-1N2128A Series Power Silicon Rectifier Diodes, (Stud Version), 35 A, 40 A, 60 A

Standard Recovery Diodes (Stud Version), 150 A

Standard Diodes (Super MAGN-A-PAK Power Modules), 600 A

Medium Power Silicon Rectifier Diodes, (Stud Version), 12 A

Standard Recovery Diodes, (Hockey PUK Version), 800 A

Standard Recovery Diodes (Stud Version), 150 A

Fast Recovery Diodes (Stud Version), 6 A, 12 A, 16 A

VS-VSKD91.., VS-VSKC91.., VS-VSKJ91.., VS-VSKE91.. ADD-A-PAK Gen 7 Power Modules Standard Diodes, 100 A

Standard Recovery Diodes (Stud Version), 150 A

Single phase bridge. (Power Modules), 25 A/35 A

Single phase bridge. (Power Modules), 25 A, 35 A

Single phase bridge. (Power Modules), 25 A / 35 A

VS-T40HF..., VS-T70HF..., VS-T85HF..., VS-T110HF... Series Power Rectifiers Diodes (T-Modules), 40 A to 110 A

Medium Power Phase Control Thyristors (Stud Version), 16 A

Phase Control Thyristors (Stud Version), 110 A

Medium Power Phase Control Thyristors (Stud Version), 50 A

High Voltage, Input Rectifier Diode, 20 A

Standard Recovery Diodes, (Hockey PUK Version), 2100 A

Three phase bridge. (Power Module), 200 A

High Voltage, Input Rectifier Diode, 10 A

Standard Recovery Diodes, (Hockey PUK Version), 3000 A

Three Phase Bridge (Power Modules), 25 A to 35 A

Fast Recovery Diodes (Stud Version), 6 A, 12 A, 16 A

Single Phase Bridge Rectifier, 2 A

Insulated Single Phase Hyperfast Bridge (Power Modules), 60 A

Three Phase Bridge, 300 A (Power Modules)

VS-VSKD91.., VS-VSKC91.., VS-VSKJ91.., VS-VSKE91.. Series ADD-A-PAK Generation VII Power Modules Standard Diodes, 100 A

95PF(R)...(W) SERIES 95 A STANDARD RECOVERY DIODES GEN II DO5. Stud Version. Features. Typical Applications. Major Ratings and Characteristics

Phase Control Thyristor RMS SCRs, 25 A, 35 A

Power Modules, Passivated Assembled Circuit Elements, 25 A

Surface Mount Fast Soft Recovery Rectifier Diode, 10 A

Inverter Grade Thyristors (Stud Version), 85 A

Three Phase Bridge (Power Modules), 25 A to 35 A

Single Phase Rectifier Bridge, 1.9 A

Phase Control Thyristors (Stud Version), 300 A

Input Rectifier Diode, 80 A

Power Modules, Passivated Assembled Circuit Elements, 40 A

Three Phase Bridge, 160 A (Power Modules)

Ultrafast Soft Recovery Diode, 150 A FRED Pt

Single Phase Rectifier Bridge, 1.2 A

Medium Power Phase Control Thyristors (Stud Version), 50 A

Input Rectifier Diode, 60 A

Thyristor / Diode (Super MAGN-A-PAK Power Modules), 570 A

Phase Control Thyristors (Stud Version), 330 A

High Performance Schottky Rectifier, 240 A

VS-70TPS12PbF, VS-70TPS16PbF High Voltage Series Thyristor High Voltage, Phase Control SCR, 70 A

Ultrafast Soft Recovery Diode, 150 A FRED Pt

Single Phase Rectifier Bridge, 3 A, 6 A

High Performance Schottky Rectifier, 400 A

85HF(R) SERIES 85 A. Stud Version STANDARD RECOVERY DIODES. Features. Typical Applications. Major Ratings and Characteristics

Three Phase Bridge, 130 A to 160 A (Power Modules)

Phase Control Thyristors (Stud Version), 110 A

Power Rectifier Diodes (T-Modules), 40 A to 110 A

VS-EBU15006-F4. FRED Pt Ultrafast Soft Recovery Diode, 150 A. Vishay Semiconductors. FEATURES BENEFITS PRODUCT SUMMARY

Standard Recovery Diodes, (Hockey PUK Version), 3800 A

Three Phase Bridge (Power Module), 45 A to 100 A

High Performance Schottky Rectifier, 100 A

High Performance Schottky Rectifier, 100 A

HEXFRED Ultrafast Diodes, 100 A (INT-A-PAK Power Modules)

HEXFRED Ultrafast Diodes, 300 A (INT-A-PAK Power Modules)

High Voltage Surface Mountable Input Rectifier Diode, 8 A

Three Phase Bridge (Power Modules), 25/35 A

FRED Pt Gen 4 Single Ultrafast Diode, 500 A (INT-A-PAK Power Modules)

Ultrafast Rectifier, 2 x 30 A FRED Pt

Fast Recovery Diodes (Hockey PUK Version), 920 A, 1050 A

Phase Control Thyristors (Hockey PUK Version), 1745 A

High Performance Schottky Rectifier, 100 A

Fast Soft Recovery Rectifier Diode, 60 A

70HF(R) SERIES 70 A. Stud Version STANDARD RECOVERY DIODES. Features. Typical Applications. Major Ratings and Characteristics

HEXFRED Ultrafast Diodes, 300 A (INT-A-PAK Power Modules)

Phase Control Thyristors (Hockey-PUK Version), 2310 A

Insulated Gen 2 Schottky Rectifier Module, 300 A

Insulated Ultrafast Rectifier Module, 280 A

Single Phase Bridge (Power Modules), 25/35 A

Inverter Grade Thyristors (Stud Version), 300 A

Phase Control Thyristors (Hockey PUK Version), 1350 A

HEXFRED Ultra Fast Soft Recovery Diode, 210 A

Insulated Hyperfast Rectifier Module, 280 A

HEXFRED Ultrafast Soft Recovery Diode, 240 A

High Performance Schottky Rectifier, 200 A

Thyristor High Voltage, Phase Control SCR, 40 A

Thyristor/Thyristor, 150 A (INT-A-PAK Power Module)

Transcription:

VS-95PF(R)...(W) High Voltage Series Standard Recovery Diodes Generation 2 DO-5 (DO-203AB) (Stud Version), 95 A 95PF(R)... DO-5 (DO-203AB) 95PF(R)...W DO-5 (DO-203AB) FEATURES High surge current capability Designed for a wide range of applications Stud cathode and stud anode version Wire version available Low thermal resistance Designed and qualified for multiple level Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 PRIMARY CHARACTERISTICS I F(AV) 95 A Package DO-5 (DO-203AB) Circuit configuration Single TYPICAL APPLICATIONS Converters Power supplies Machine tool controls Welding Any high voltage input rectification bridge MAJOR RATINGS AND CHARACTERISTICS PARAMETER TEST CONDITIONS VALUES UNITS 95 A I F(AV) T C 128 C I F(RMS) 149 A 50 Hz 1700 I FSM A 60 Hz 1800 I 2 t 50 Hz 14 500 60 Hz 13 500 A 2 s V RRM Range 1400 to 1600 V T J -55 to +150 C ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS TYPE NUMBER VS-95PF(R)...(W) VOLTAGE CODE V RRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V V RSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 140 1400 1650 160 1600 1900 I RRM MAXIMUM AT T J = 150 C ma 4.5 Revision: 11-Jan-18 1 Document Number: 93533

VS-95PF(R)...(W) High Voltage Series FORWARD CONDUCTION PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum average forward current 95 A I at case temperature F(AV) 180 conduction, half sine wave 128 C Maximum RMS forward current I F(RMS) 149 A t = 10 ms No voltage 1700 Maximum peak, one cycle forward, t = 8.3 ms reapplied 1800 I non-repetitive surge current FSM t = 10 ms 100 % V RRM 1450 A t = 8.3 ms reapplied Sinusoidal half wave, 1500 t = 10 ms No voltage initial T J = 150 C 14 500 Maximum I 2 t for fusing I 2 t t = 8.3 ms reapplied 13 500 t = 10 ms 100 % V RRM 10 500 A 2 s t = 8.3 ms reapplied 9400 Maximum I 2 t for fusing I 2 t t = 0.1 ms to 10 ms, no voltage reapplied 145 000 A 2 s Low level value of threshold voltage V F(TO) (16.7 % x x I F(AV) < I < x I F(AV) ), T J = T J maximum 0.73 V Low level value of forward slope resistance r f (16.7 % x x I F(AV) < I < x I F(AV) ), T J = T J maximum 2.4 m Maximum forward voltage drop V FM I pk = 267 A, T J = 25 C, t p = 400 μs rectangular wave 1.40 V THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum junction and storage temperature range T J, T Stg -55 to +150 C Maximum thermal resistance, junction to case R thjc DC operation 0.27 Thermal resistance, case to heatsink R thcs Mounting surface, smooth, flat and greased 0.25 K/W Maximum allowable mounting torque (+ 0 %, - 10 %) Not lubricated thread, tighting on nut (1) 3.4 (30) Lubricated thread, tighting on nut (1) 2.3 (20) Not lubricated thread, tighting on hexagon (2) 4.2 (37) Lubricated thread, tighting on hexagon (2) 3.2 (28) Approximate weight 15.8 g 0.56 oz. Case style See dimensions - link at the end of datasheet DO-5 (DO-203AB) Notes (1) Recommended for pass-through holes (2) Torque must be applicable only to hexagon and not to plastic structure, recommended for holed heatsink N m (lbf in) R thjc CONDUCTION CONDUCTION ANGLE SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION TEST CONDITIONS UNITS 180 0.14 0.10 120 0.16 0.17 90 0.21 0.22 60 0.30 0.31 30 0.50 0.50 T J = T J maximum Note The table above shows the increment of thermal resistance R thjc when devices operate at different conduction angles than DC K/W Revision: 11-Jan-18 2 Document Number: 93533

VS-95PF(R)...(W) High Voltage Series Maximum Allowable Case Temperature ( C) 160 150 140 130 120 110 0 10 20 30 40 50 60 70 80 90 100 Average Forward Current (A) 95PF(R) Series RthJC = 0.27 K/W 180 Sine Peak Half Sine Wave Forward Current (A) 1800 1600 1400 1200 1000 800 600 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial Tj = Tj Max. No Voltage Reapplied Rated Vrrm Reapplied 400 85HF(R) 95PF(R) Series 200 0.01 0.1 1 Pulse Train Duration (s) Fig. 1 - Current Ratings Characteristics Fig. 3 - Maximum Non-Repetitive Surge Current Peak Half Sine Wave Forward Current (A) 1600 1400 1200 1000 800 600 At Any Rated Load Condition And With Rated Vrrm Applied Following Surge. Initial Tj = Tj Max. @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s 95PF(R) 85HF(R) Series 400 1 10 100 Number Of Equal Amplitude Half Cycle Current Pulses (N) Fig. 2 - Maximum Non-Repetitive Surge Current Instantaneous Forward Current (A) 1000 Tj = Tj Max 100 Tj = 25 C 10 95PF(R) 85HF (R) Series 1 0 0.5 1 1.5 2 2.5 Instantaneous Forward Voltage (V) Fig. 4 - Forward Voltage Drop Characteristics Transient Thermal Impedance Z thjc (K/W) 1 0.1 Steady State Value RthJC = 0.27 K/W (DC Operation) 95PF(R) Series 95PF(R) Series 0.01 0.0001 0.001 0.01 0.1 1 10 Square Wave Pulse Duration (s) Fig. 5 - Thermal Impedance Z thjc Characteristics Revision: 11-Jan-18 3 Document Number: 93533

VS-95PF(R)...(W) High Voltage Series ORDERING INFORMATION TABLE Device code VS- 95 PF R 160 W 1 2 3 4 5 6 1 - product 2-95 = standard device 3 - PF = plastic package 4 - None = stud normal polarity (cathode to stud) R = stud reverse polarity (anode to stud) 5 - Voltage code x 10 = V RRM (see Voltage Ratings table) 6 - None = standard terminal (see dimensions for 95PF(R)... - link at the end of datasheet) W = wire terminal (see dimensions for 95PF(R)...W - link at the end of datasheet) Dimensions LINKS TO RELATED DOCUMENTS www.vishay.com/doc?95345 Revision: 11-Jan-18 4 Document Number: 93533

Outline Dimensions DO-203AB (DO-5) for 50PF(R)...(W), 80PF(R)...(W), and 95PF(R)...(W) Series DIMENSIONS FOR 80PF(R), 50PF(R), AND 95PF(R) SERIES in millimeters 4.2 MAX. 6.45 MIN. Ø 3 1.2 MAX. 3.5 MIN. 4 MIN. Plastic cap. 25.4 MAX. 11.45 MAX. 2.4 REF. 11 ± 0.4 1/4"28-UNF-2A 17.25 MAX. Ø 15.95 MAX. Ø 17.15 MAX. 18.9 + 0.1 0.0 Revision: 20-Apr-16 1 Document Number: 95345

Outline Dimensions DIMENSIONS FOR 80PF(R)...(W), 50PF(R)...(W), AND 95PF(R)...(W) SERIES in millimeters 2.05 MAX. Plastic cap. 25.4 MAX. 11.45 MAX. 2.4 REF. 11 ± 0.4 1/4"-28-UNF-2A 17.25 MAX. Ø 15.95 MAX. Ø 17.15 MAX. 18.9 + 0.1 0.0 Revision: 20-Apr-16 2 Document Number: 95345

Outline Dimensions DIMENSIONS FOR 52PF(R), 82PF(R), AND 97PF(R) SERIES in millimeters 11.20-12.20 Ø 6.80-7.00 6.6 mm 2 external lead with blue or red sleeve insulation 115.00-123.00 127.40-134.40 Plastic cap. 11.05-11.45 2.4 REF. 10.60-11.40 1/4"-28-UNF-2A Revision: 20-Apr-16 3 Document Number: 95345

Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay ), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer s technical experts. Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000