2Win Binocular Mobile Refractometer and Vision Analyzer

Similar documents
Wearable Adaptive Refractor. Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

WEARABLE WIRELESS ADAPTIVE REFRACTOR

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

ABO Certification Training. Part I: Anatomy and Physiology

Tabletop Refraction System TS-310

Impressive Wide Field Image Quality with Small Pupil Size

OCULUS Binoptometer 4P

The First True Color Confocal Scanner

Intelligent Refractor RT-5100

SPHERE, CYLINDER, AXIS, and ADD Power: Why these four variables? Example Prescriptions: UNDERSTANDING A PRESCRIPTION SPHERICAL LENSES 8/31/2018

Intelligent Refractor RT-5100

Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef

The First True-Color Wide-Field Confocal Scanner

Distribution of Refractive Error. 20 year old males. Distribution of Aberrations

The First True Color Confocal Scanner on the Market

RETINOSCOPY LABORATORY MICHAEL DAVIDSON RON OFRI

Optics. The Eyes Have It. Chapter Nine. by Tim Root. pneumatic retinopexy, scleral buckles, and three corneal transplants

Concepts of Optics Quiz. 8. Spherical lenses focus along a single point; cylindrical lenses focus along a.

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Basic Principles of the Surgical Microscope. by Charles L. Crain

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

Slide 4 Now we have the same components that we find in our eye. The analogy is made clear in this slide. Slide 5 Important structures in the eye

Auto Ref / Keratometer ARK-560A / 530A / 510A

25 cm. 60 cm. 50 cm. 40 cm.

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

By Dr. Abdelaziz Hussein

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

Topic 4: Lenses and Vision. Lens a curved transparent material through which light passes (transmit) Ex) glass, plastic

Refraction of Light. Refraction of Light

FOR PRECISE ASTIGMATISM CORRECTION.

Refractive Power / Corneal Analyzer. OPD-Scan III

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

DESIGN OF GAUSSIAN SPATIAL FILTER TO DETERMINE THE AMOUNT OF REFRACTION ERROR IN HUMAN EYE

Keeler Direct Ophthalmoscopes

Marco TRS Total Refraction System

HRK-7000 / HRK-7000A Auto Ref-Keratometer

The eye & corrective lenses

A Handbook of Trial Lens Set 158 pcs

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

Exam 3--PHYS 151--S15

3. Study the diagram given below and answer the questions that follow it:

Eschenbach Low Vision Training Program

3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s

ERK-9000 Auto Ref/Kertometer

STUDY OF ADULT STRABISMUS TESTING PROCEDURES MANUAL

EyeQue Personal Vision Tracker: How It Works

The Optics of Mirrors

Biology 70 Slides for Lecture 1 Fall 2007

Astigmatism. image. object

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)

Kinder products for your most precious patients

Physics Chapter Review Chapter 25- The Eye and Optical Instruments Ethan Blitstein

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

High Touch High Tech

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

LM-1200 / 1000(P) AUTO LENSMETER

Aspects of Vision. Senses

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

Slab Off or Bicentric Grinding

Objective Refraction: Retinoscopy

Subtractive because upon reflection from a surface, some wavelengths are absorbed from the white light and subtracted from it.

Vision Shaping Treatment

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

Lenses- Worksheet. (Use a ray box to answer questions 3 to 7)

The TRIumph of Excellence

Types of lenses. Shown below are various types of lenses, both converging and diverging.

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

A Checklist for Managing Spectacle Lens Complaints. Presented By: Raymond P. Dennis, M.A. (Ed.) Middlesex Community. Patient Complaints

PHYSICS. Chapter 35 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

Orbis International. Vision and Refraction

30 Lenses. Lenses change the paths of light.

Goldmann vs. Humphrey

Astronomy 80 B: Light. Lecture 9: curved mirrors, lenses, aberrations 29 April 2003 Jerry Nelson

OCULUS Keratograph 4. Topographer. We focus on progress

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Visual acuity finally a complete platform

Chapter 4 Assessment of Study Measures

Explanation of Aberration and Wavefront

An Application of Lenses: The Human Eye. Prof. Jodi Cooley Supplementary Material for PHY1308 (General Physics Electricity and Magnetism)

Keratometry: Vertical Axis. Axis

Class 10 Science NCERT Exemplar Solutions Human Eye and Colourful World

Refraction, Lenses, and Prisms

Converging and Diverging Surfaces. Lenses. Converging Surface

Auto Ref/Kerato/Tonometer TONOREF 2

Work environment. Retina anatomy. A human eyeball is like a simple camera! The way of vision signal. Directional sensitivity. Lighting.

Photography (cont d)

Chapter 6 Human Vision

5 Easy Steps to Purchasing Glasses Online

Optics: Lenses & Mirrors

MPH150 USER MANUAL 1 - V 150E H P 07/2013 M M U

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Clinical Update for Presbyopic Lens Options

Interventions for vision impairments post brain injury: Use of prisms and exercises. Dr Kevin Houston Talia Mouldovan

Transcription:

2Win Binocular Mobile Refractometer and Vision Analyzer The smartest way to detect refractive errors and vision problems

Adaptica was founded in 2009 as a spin-off of the University of Padova, Italy specialising in adaptive optics and optoelectronics applied to Industry and astronomical research. Adaptica leverages on its technological know-how and competences in Astronomy to move from a better vision of the universe and its galaxies towards exploring vision and the human eye. Shortly after, Adaptica expanded into health-care with particular focus to vision and eye-care. Adaptica develops and manufactures mobile, smart and ease of use diagnostic pieces of equipment that are currently distributed in 40+ countries around the world. 2 www.adaptica.com

Device and main applications The 2WIN is a mobile binocular refractometer and vision analyzer that measures both eyes at the same time, in real life vision conditions. Refraction of infants and children from 2 months of age, seniors, impaired and non-cooperative patients. Early detection and documentation of multiple amblyogenic factors. Un-aided binocular refraction of all other patients. Over-refraction of glasses or contact lenses. Refraction The 2WIN measurement principle is eccentric photo-retinoscopy. Infrared (IR) light is projected through the patient pupils and onto the retina. Depending upon the refractive error, the reflected light forms a specific crescent-shaped brightness pattern within the pupil. The 2WIN measures spherical power, cylinder power and axis by interpreting the reflected light crescent pattern and position. The 2WIN infrared exam also provides valuable information about corneal abnormalities as well as ocular media opacities such as cataracts. Measurements Refractive errors Sight anomalies Pupil parameters Refractive errors - Myopia, hyperopia, astigmatism and other amblyogenic factors. Sight anomalies that may be related to anisometropia, anisocoria, strabismus, phoria. Pupil parameters - pupil size, pupil distance and head tilt. Benefits 100% mobile Binocular, 1 meter Hand-held, small, Battery operated Easy, quick, working distance light weight (long battery life) non-invasive Cost effective 3

Ideal with infants, children and non-cooperative patients. It measures refraction and correction in natural vision conditions. How to use the 2WIN Ambient light: a uniform dim light environment is necessary (not totally dark nor too bright) to achieve 3,5 to 6 mm pupil size; in addition make sure that no direct light hits the patient s face and ensure uniform light on both eyes. Stand or sit at 1 meter distance from the patient and firmly hold the 2WIN horizontally with both hands. Instruct the patient to keep his/her eyes wide open, clear of eyelids or eyelashes, and to fixate on the center of the camera. The 2WIN operates as a photo camera, thus proper focusing is necessary by slightly moving the instrument forward and backword. The green bar in the display indicates when the ideal focal distance of 1 meter has been reached. Make sure the corneal reflexes appear as small and bright as possible. Press and hold the START button to enter the focusing phase. Slightly adjust the distance looking at the corneal reflexes until the image comes into focus and the focus bar is green. Release the START button and the 2WIN automatically displays the measurements on the screen within approx. 3 seconds. How to read the display Cylinder Right Eye Sphere Axis Left Eye Screening Result: Realiability index Measurement Window Live Display Fixation Plot Pupil & Gaze Status Bar Amblyopia screening Pupil distance Gaze Head Tilt Pupil size Fixation Plot TEST THRESHOLD RESULT Hyperopia Sph < 1.5 d Ok Myopia Left Eye Sph < 0.75 d No Astigmatism Cyl < 1.5 d Ok Anisometropia Diff < 1 d No WiFi USB Age range Visible Fixation Target Battery Life Audible Fixation Target Anisocoria Diff < 1 mm Ok Gaze < 6 Ok 4 www.adaptica.com

How to read the printout 2WIN measurements can be stored and/or printed. The exams are stored internally in a micro-sd card in.pdf format. Exam Date Right Eye Left Eye Sphere Cylinder Axis Spherical Equivalent Index of Reliability Gaze Pupil Distance Pupil Size Fixation Plot Years and Outcome Criteria Dr s signature Screening Result 5

Additional features Connectivity The 2WIN is equipped with a WiFi module and can be connected to a computer network. Download and visualize patient data from the 2WIN to an external device. 2WIN exams and patient data can therefore be downloaded and visualized on external devices such as smartphone, tablet, pc by using a secure file transfer client software. The external smart device can be used to input patient information and/or other data and commands. 2WINNY mask kit 2WINNY is a funny, attractive and removable mask to help the operators in daily interactions with infants and children. It is an accessory designed to draw kid s attention on the 2WIN before starting the examination and activating the visible and audible fixation targets. Operators select the mask on the basis of child age and apply it on the front side of the 2WIN. 6 www.adaptica.com

Intermediate Distance application The 2WIN measures the patient s refraction while reading from VDUs, at a distance of 66 cm (2 ). In all those cases when reading at such distance proves difficult, the 2WIN calculates the necessary additional power (ADD) to restore best vision. The application requires the use of an additional lens that is inserted in the central aperture of the 2WIN; the additional lens together with a 66 cm reading chart completes the kit. Analysis of corneal reflexes This application provides complete information regarding the position of corneal reflexes. Measurements are expressed either in prism diopters or degrees. A black hand held filter is included and allows the 2WIN infrared rays to pass through while blocking all visible light: therefore a reliable cover test is made possible. When a deviation appears in the uncovered eye the output is ET: esotropia; XT: exotropia. When a deviation appears in the covered eye the output is EP: esophoria; XP: exophoria. When a vertical deviation appears the output follows the same rules above exposed (HT: hypertropia; IT: ipotropia; HP: hyperphoria; IP: ipophoria). Complete and objective assessment of the visual function. Early detection of refractive errors. Technical specifications Operating mode: Binocular/monocular Refraction Measurement: Automatic Sphere range: ±5 D, precision 0.25 D Cylinder range: ±5 D, precision 0.25 D Cylinder axis: 1-180, step 1 Pupil size: Automatic detection, 4-7 mm, step 0.1 mm Working distance: 1 m ± 5 cm Data Interface: Wi-Fi, USB, microsd card Printer interface: USB, Infrared (irda) Power: Rechargeable battery Battery charger: 110-220 Vac, 0.5 A Size: 165x130x98mm Pupil distance: Automatic detection, 30-120 mm, step 1 mm Display: 3.5 Fixation target: Built-in Acoustic target: Built-in Weight: 840 g (30 oz) Options/Accessories: Portable wireless printer, supplementary battery, battery-charger, metal case, WiFi connectivity 7

Rev. 0.1-2015 EN The 2WIN has been a great addition to our office. It has given me objective data on young children that are often hard to get good co-operation and fixation. R. Scott Penny, O.D. Sprinfield, OH Adaptica Srl C/o Net Center Via San Marco, 9/H 35129 Padova, Italy Ph/ Fax +39 049 773 968 www.2winforvision.com info@adaptica.com