C.Z. INDUSTRY AND TECHNOLOGY. CO., LTD

Similar documents
ILX554B pixel CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader

Miniature Spectrometer Technical specifications

ILX526A pixel CCD Linear Image Sensor (B/W)

ILX pixel CCD Linear Image Sensor (B/W)

RaLED T8-RetroFit Star RL-T8 36 S 14W/840/G13 EM

ILX pixel CCD Linear Image Sensor (B/W)

7926-pixel CCD Linear Image Sensor (B/W) For the availability of this product, please contact the sales office.

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

The Photoelectric Effect

Microscope-Spectrometer

LED Lighting Flux and Color Measurement System (LFC)

Maya2000 Pro Spectrometer

1 Detection of Latent Fingerprints. 2 The Latentmaster System. 3 The Latentmaster Software. 4 Latentmaster Components

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

WHITE PAPER. Sensor Comparison: Are All IMXs Equal? Contents. 1. The sensors in the Pregius series

Introduction. UV Sterilization System Dimension 3.5mm* 3.5mm* 3.5mm. UV Photo-catalyst ESD protection up to 8KV. UV Sensor Light RoHS compliant

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

Imaging Photometer and Colorimeter

Introduction. UV Sterilization System Dimension 3.5mm* 3.5mm* 3.5mm. UV Photo-catalyst ESD protection up to 8KV

/* */ Applications Physical background Technical data References Downloads. XtalLight 100C

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

ELUA2016OGB 0.08W Series

LED Lighting - Error Consideration for Illuminance Measurement

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

Estimation of spectral response of a consumer grade digital still camera and its application for temperature measurement

UV-NIR LASER BEAM PROFILER

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

User-configured for Maximum Flexibility

ELUA4545OG3 1.8W Series

Ultraviolet Visible Infrared Instrumentation

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

MEASURING CRUST COLOR WITH HYPERSPECTRAL IMAGING

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

ALS-PDIC243-3B. 5mm T-1 3/4 Ambient Light Sensor. Features. Description. Applications

Where Image Quality Begins

Cooled cameras for scientific applications and astronomy. Ian Alderton Alrad Imaging division of Alrad Instruments Ltd

Block Diagram GND. amplifier 5 GND G R B

SPECTRAL SCANNER. Recycling

Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection

Adventures of a Laserchick Sr. Physics Educator ExplOratorium

GSM OPTICAL MONITORING FOR HIGH PRECISION THIN FILM DEPOSITION

Improvements of the PLD (Pulsed Laser Deposition) Method for Fabricating Photocathodes in ICMOS (Intensified CMOS) Sensors

Oriel Flood Exposure Sources

paint for coil coating

ELPL-COB-100W SERIES LIGHT-ENGINE CATALOGUE

Experimental Analysis of Luminescence in Printed Materials

Effect of Spectral Power Distribution on the Resolution Enhancement in Surface Plasmon Resonance

SPECIFICATION FOR APPROVAL 1/8W 0816 LOW RESISTNACE CHIP RESISTOR

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

DIGITAL PACKAGING DECORATION

VELOX IDS 250. Direct-to-shape digital decoration for mass production of cylindrical containers. Unprecedented decoration quality

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System

Make Your Own Digital Spectrometer With Diffraction Grating

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

Absentee layer. A layer of dielectric material, transparent in the transmission region of

Round Through-Hole LED Lamp (3 mm)

CLAMP SYSTEM

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Fluorescent lamp Spectralux Plus NL-T8 58W/840/G13

Broadbandradiometer specbos 1211

TOSHIBA CCD LINEAR IMAGE SENSOR CCD(Charge Coupled Device) TCD1205DG

CAMAG TLC VISUALIZER 2

FX-4400 High-Output Xenon Flashlamps

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens

Philips Essential LEDtube 600, 1200mm

Supporting information

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

ULS24 Frequently Asked Questions

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Infrared Receiver Control Receiver Module IRM-36xxM3 Series

Lambda 1050 / 950 UV/Vis/NIR

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

Nano-100 Spectrophotometer. Brief introduction

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Photoelectric effect

CANEX GUITAR CANEX GUITAR. Let s share the same music of the world, Live for music! Welcome to CANEXMUSIC world!

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

SPECTRAL IRRADIANCE DATA

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

OPERATING AND MAINTENANCE MANUAL CORONAFINDER UV VIEWER

Optional AR coating and wedge windows are available

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

CVI LASER OPTICS ANTIREFLECTION COATINGS

sensicam em electron multiplication digital 12bit CCD camera system

UV Measurement. Information Sheet. Dipl.-Ing. Andreas Renzel. Basics of UV measurement and solutions for UV curing applications.

Bandpass Interference Filters

In the name of God, the most merciful Electromagnetic Radiation Measurement

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

TCD1711DG TCD1711DG. Features. Pin Connection (top view) Maximum Ratings (Note 1)

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

ND:YAG/ND:YLF...T-26 TUNABLE LASER MIRRORS...T-28 MISCELLANEOUS MIRRORS...T-30 ANTI-REFLECTIVE OVERVIEW...T-31 0 DEGREE ANGLE OF INCIDENCE...

Transcription:

C.Z. INDUSTRY AND TECHNOLOGY. CO., LTD UV COATED CCD CCD: 3648-Pixel ccd 2048-Pixel ccd

CATALOGE CONTENTS 1.Product information........... 2.Performance.......... 3.UV CCD Comparing Spectral Response Curve Before And After 4.Refer. Curves.... 5. Packages... 6.After sales service... - 1 -

1.Product Name and Introduction: 1.1. Product Name and Type: CCD : Sony ilx511 Sony ilx554b Sony ilx526a Toshiba TCD1304DG 1.2 Price list: Please see Attached Table 1,2,3 1.3 Pictures UV COATED CCD - 2 -

2. Performance For traditional CCD, the quantum efficiency is low below 400nm. While by using UV-enhanced technology, which can improve the response in ultraviolet band. However, the spectrum signal will become weak, and resolution response will be reduced. But by using UV-enhanced technology, through vacuum coating method, done the coating directly on the surface of CCD itself, which can improve the CCD's response on UV 200nm. So then on the 167nm, 185nm, 190nm, 200nm and 253.6nm, the relative strength can be improved 10-30 times or higher. Also the response signal on the ultraviolet band is also significantly enhanced. So that the operating frequency can be achieved from 150nm to 400nm. Our method has been compared with many foreign manufacturers, technical indicators are full achieved. More important is that our UV coating's cost is not high, can help to achieve mass production in many industries. Types: Sony ilx511 Sony ilx554b Toshiba 1304DG and so on CCD/CMOS - 3 -

3. UV CCD Comparing Spectral Response Curve Before And After: 3.1 Before UV COATED: 3.2 After UV COATED 185-320nm Deuterium lamp spectrum - 4 -

4.CURVE 1 C.Z. INDUSTRY AND TECHNOLOGY. CO., LTD

CURVE 2 C.Z INDUSTRY AND TECHNOLOGY. CO., LTD - 1 -

CURVE 3 C.Z INDUSTRY AND TECHNOLOGY. CO., LTD - 2 -

5.Packages C.Z. INDUSTRY AND TECHNOLOGY. CO., LTD PACKAGE STRUCTURE PACKAGE MATERIAL Cer-DIP LEAD TREATMENT TIN PLATING LEAD MATERIAL 42 ALLOY PACKAGE MASS 5.20g

6.After sales service 6.1 When receiving the goods, please count the quantity, if anything less than ordered, please inform within three days. We will check our record and re-send accordingly. 6.2 After receiving the goods, please test and inform if there is any quality problem within one month. If there is quality problem in fact, we will replace or return payment accordingly. (IF THE QUALITY PROBLEM MADE BY MAN-MADE DAMAGE BY USER, WE WONT REPLACE FREE) - 1 -

Note:all prices are including air freight by DHL/TNT/FEDEX/UPS/EMS (ALL CCD ARE WITHOUT GLASS) TABLE 1: Commodity Specification Unit Quantity Unit price Delivery time UV CCD Sony ILX554B-UV PCS 5-10 USD115 5-10days PCS 11-50 USD110 10-15days PCS 51-100 USD105 20-25days PCS 101-200 USD100 25-30days PCS 201-500 USD90 25-30days PCS 501-1000 USD85 25-30days TABLE 2: Commodity Specification Unit Quantity Unit price Delivery time UV CCD TOSHIBA 1304DG-UV PCS 5-10 USD115 5-10days PCS 11-50 USD110 10-15days PCS 51-100 USD105 20-25days PCS 101-200 USD100 25-30days PCS 201-500 USD90 25-30days PCS 501-1000 USD85 25-30days TABLE 3: Commodity Specification Unit Quantity Unit price Delivery time UV CCD Sony ILX511-UV PCS 5-1000 USD170 ACCORDING TO PURCHASING ORDER Original factory has been discontinued OEM processing. - 2 -