User's Manual Model SE14 Magnetic Flow Converter

Similar documents
2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

DPharp Differential Pressure and Pressure Transmitters

IP26 Series Current to Pneumatic Converter

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

User s Manual Model EJA510A and EJA530A Absolute Pressure and Gauge Pressure Transmitters [Style: S2]

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

YTA Series Temperature Transmitters (Hardware) [Style: S3]

Installation guide 873 SmartRadar Control Unit & Antenna Unit

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Instruction Manual. Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters. [Style: S2] IM 1C22H1-01E 10th Edition

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

YTA610 and YTA710 Temperature Transmitter (Hardware)

Instruction Manual. Model EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters. [Style: S2] IM 1C22J1-01E 10th Edition

User s Manual EJX118A and EJX438A Diaphragm Sealed Differential Pressure and Pressure Transmitters

User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2]

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

YTA610 and YTA710 Temperature Transmitters (Hardware)

User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A

Installation guide 877 FDI Field Display & Interface

General Specifications

General Specifications

Intrinsic Safety Control Drawing

General Specifications

Installation guide 971 SmartRadar LTi

PROline promag 53 Division 1

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

INSTRUCTION MANUAL (ATEX / IECEx)

User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A

FLEX Ex Power Supplies

User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438

Temperature Input Module for Zone 1 Series 9482/32

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

User s Manual Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E

Wireless Base Radio. Wireless Transmitters

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

General Specifications

General Specifications

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Installation guide 854 XTG Level Gauge

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Certificate of Compliance

General Specifications

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

General Specifications

Loop Powered Indicator

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

General Specifications

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

Rosemount 148 Temperature Transmitter

CERTIFICATE OF COMPLIANCE

Model 264IB. ABB 2600T Series Engineered solutions for all applications

PRetrans Table of contents

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

MODEL: M2DYS SEN TRONIC AG

General Specifications

General Specifications

General Specifications

Level Lance Model 5100

Installation guide 970 SmartRadar ATi

ATEX Installation Drawings and Instructions

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Product manual wire programmable RTD transmitter

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

LR Position Switches TECHNICAL DATASHEET

ProcessMaster / HygienicMaster

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Single-Channel Safety Barriers Series 9001

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

SATRON VB Pressure Transmitter

Safety Instructions Proline Promag 500

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Installation guide 970, 971 and 973 series SmartRadar

General Specifications

Rosemount 5400 Series Radar Level Transmitter

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

EN Series Installation Manual

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Field IT 2600T Series Pressure Transmitters

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Transcription:

User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the number of "EMC Conformity Standards". Add the caution note. Page 12-1 to 12-5 12. EXPLOSION PROTECTED TYPE INSTRUMENT Applicable Standard and Certificate No are added in each Ex-proof Technical Data description. Mar. 10, 2009 Yokogawa Electric Corporation

10. OUTLINE Maximum Power Consumption: 11W for SE***DJ/EJ+SE14 Insulation Resistance: 100MΩ between power terminals and ground terminal at 500V DC. 100MΩ between power terminals and each output terminal at 500V DC. 20MΩ between each output terminal (except for EX1 and EX2) and ground terminal at 100V DC. 20MΩ between (EX1 or EX2) and ground terminal at 50V DC. Withstand Voltage: 1500V AC between power terminals and ground terminal for 1 minute. (for -A1/A2 power supply) 500V AC between power terminals and ground terminal for 1 minute. (for -D1 power supply) CAUTION When performing the Voltage Breakdown Test, Insulation Resistance Test or any unpowered electrical test, wait 10 seconds after the power supply is turned off before removing the housing cover. Be sure to remove the Short Bar at terminal G. After testing, return the Short Bar to its correct position. Screw tightening torque should be 1.18 N-m(0.88ft-lb)or more, because the G- terminal is thought as a protective grounding and should conform to the Safety Requirements. Safety Requirement Standard: IEC1010, EN61010 EMC Conformity Standards:, EN61326-1 Class A, Table 2 (For use in industrial locations) EN61326-2-3 EN61000-3-2 ClassA EN61000-3-3 CAUTION This instrument is a Class A product, and it is designed for use in the industrial environment. Please use this instrument in the industrial environment only. NORMAL OPERATING CONDITION Ambient Temperature: -20 to 60 C (-4 to 140 F) Ambient Humidity: 5 to 95 % RH (no condensation) Rated Power Supply Voltage: 100V AC/DC version: Range 80 to 127V AC, 47 to 63Hz 90 to 110V DC 230 V AC version: Range 180 to 264V AC 24 V DC/AC version: Range 20.4 to 28.8V DC/AC Supplied Power and Max. Cable Length for 24V DC version: Allowable cable length m(ft) 1000(3300) 900(2970) 800(2640) 700(2310) 600(1980) 500(1650) 400(1320) 300(990) 200(660) 100(330) 0 20 22 24 26 28 (V) Cable cross section area : 1.25mm 2 Cable cross section area : 2mm 2 F01.EPS 10-2 Altitude at installation side: Max.2000m above sea level Installation category based on IEC1010: II (See Note) Pollution level based on IEC1010: 2 (See Note) Note: The Installation category implies the regulation for impulse withstand voltage. It is also called the Overvoltage category. II applies to electrical equipment. Pollution level describes the degree to which a solid, liquid or gas which deteriorates dielectric strength is adhering. 2 applies to a normal indoor atmosphere. FUSE: 2A 250V (Time-Lag Type) TERMINAL CONNECTION Terminal Symbols PLS/ALM OUT CUROUT POWER SUPPLY SA A B SB C EX1 EX2 P+ P- I+ I- L/+ N/- G Description A shield Flow signal input B shield Common Excitation current output Pulse, alarm or status output Current output 4 to 20mA DC Power supply and Ground Protective grounding T03-1.EPS ACCESSORIES Data sheet 1 Unit labels sheet 1 Hexagonal wrench 1 (for special screw of terminal cover/display cover.) Plug 1 (in case of DC power supply version) Mounting bracket 1set MODEL AND SUFFIX CODE Magnetic Flow Converter: Model SE14 Aux.Code Output Signal Indicator Power Supply Suffix code... -J... D... E... Electrical Connection (refer to Note1) Option Codes NN... H1... H2... -A1... -A2... -D1... 0... 2... 3... 4... /... Description Magnetic flow converter Always J 4-20mA and Pulse or Alarm, simultaneous 2-output (BRAIN) 4-20mA and Pulse or Alarm, simultaneous 2-output (HART) Non Indicator With Indicator With Indicator and Setting SW 80 to 127V AC / 90 to 110VDC 180 to 264 V AC 20.4 to 28.8V DC/AC JIS G1/2 Female ANSI 1/2NPT Female DIN Pg13.5 Female ISO M20 1.5 Female Note1: Only ANSI 1/2NPT electrical connection is available for FM or CSA explosion proof type. JIS G1/2 electrical connection is not available for any explosion proof type. T05.EPS Dedicated Signal Cable: Model Suffix Code Description AM011... Dedicated cable for magnetic flowmeter End -0... Non termination treatment -4... Terminated Cable length -L... Enter the length in m (Max 300m) Style code *A... Style A Optional specification /C.. Number of end treatment parts Note 1: A user provided two conductor cable is required for coil excitaiton. Note 2: The maximum temperature for the signal cable is 80 C(176 F). T10.EPS

12. EXPLOSION PROTECTED TYPE INSTRUMENT 12. EXPLOSION PROTECTED TYPE INSTRUMENT In this section, further requirements and differences for explosion proof type instrument are described. For explosion proof type instrument, the description in this chapter is prior to other description in this User's Manual. NOTE The terminal box cover and display cover is locked by special screw. In case of opening the cover, please use the Hexagonal Wrench attached. CAUTION Be sure to lock the cover with the special screw using the Hexagonal Wrench attached after tightening the cover. 12.1 CENELEC ATEX(KEMA) Only trained persons use this instrument in industrial locations. EN50014, EN50018, EN60529, EN61010-1 Certificate: KEMA 98ATEX3230 Group: II Category: 2G Type of Protection: EEx d II C T6 Electrode Circuit Um; 250Vac/dc Excitation Circuit; 41V max. 6/6.25Hz Enclosure; IP67 Ambient Temp.: -20 to 60 C Temperature Code: T6 (2) Electrical Connection The type of electrical connection is stamped near the electrical connection port according to the following codes. Screw Size Marking ISO M20x1.5 female M ANSI 1/2NPT female A DIN Pg13.5 female D (3) Installation All wiring shall comply with local installation requirements and local electrical code. In hazadous locations, the cable entry devices shall be of a certified flameproof type, suitable for the conditions of use and correctly installed. Unused apertures shall be closed with suitable flameproof certified blanking elements. (The plug attached is flameproof certified.) (4) Operation Wait 10 min. after power is turned off, before opening the covers. Take care not to generate mechanical spark (5) Maintenance and Repair will void the certification. 12-1

(6) Data Plate MODEL SUFFIX STYLE SUPPLY AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING MAGNETIC FLOWCONVERTER CURRENT OUTPUT PULSE OUTPUT Tamb ENCLOSURE TAG NO. NO. VDC 11Wmax. VAC~47 to 63Hz 11Wmax. 4-20mA (600Ωmax.) 30V DC 0.2Amax. 20 to +60 C IP67 *1) *2) II 2G KEMA No. : KEMA 98ATEX 3230 EEx d II C T6 ENCLOSURE : IP67 Made in *3) MODEL : Specified model code SUFFIX : Suffix codes of the model code STYLE : Specified style code SUPPLY : Power supply voltage of apparatus CURRENT OUTPUT : Output signal of apparatus PULSE OUTPUT : Output signal of apparatus Tamb : Ambient temperature ENCLOSURE : Enclosure protection number TAG NO. : Tag number NO. : Manufacturing serial number CE : CE marking ExII 2G : Group II Catergory 2 Gas atmosphere KEMA No. : Certificate number EExd IICT6 : Protection type and temp. class : Warning to apparatus YOKOGAWA : Name and address of manufacturer *1) The third figure from the last shows the last one figure of the year of production. For example, the year of production of the product engraved as follows is year 1998. No. F261GA091 813 Produced in 1998 *2) The identification number of the notified body *3) The product-producing country 12. EXPLOSION PROTECTED TYPE INSTRUMENT 12.2 FM Model SE14/FF1/FN1 can be selected the type of protection(fm Explosionproof or Nonincendive) for use in hazardous locations. For the installation of this converter, once a particular type of protection is selected, any other type of protection can not be used. The installation must be in accordance with the description about the type of protection in this user s manual. In order to avoid confusion, unnecessary marking is crossed out on the label other than the selected type of protection when the flow converter is installed. 12.2.1 FM Explosionproof (Optional Code /FF1) FM 3600, FM 3615, FM 3810, NEMA 250 Explosionproof for Class I Division 1 Groups A, B, C and D. Dust-ignitionproof for Class II/III Division 1 Groups E, F and G. Temp. Code: T6 Enclosure: NEMA 4X (2) Wiring All wiring shall comply with National Electrical Code ANSI/NFPA 70 and local electrical code. SEAL ALL CONDUITS WITHIN 18 INCHES. Wiring shall be in conduit as shown in the figure. HAZARDOUS LOCATIONS Magnetic Flow Converter Conduit Sealing Fitting 18"(457mm)Max. 12-2

12. EXPLOSION PROTECTED TYPE INSTRUMENT (3) Operation OPEN CIRCUIT BEFORE REMOVING COVER. SEAL ALL CONDUITS WITHIN 18 INCHES. INSTALL IN ACCORDANCE WITH THE USER S MANUAL. Take care not to generate mechanical spark will void the approval of Factory Mutual Research Corporation. 12.2.2 FM Nonincendive (Optional Code /FN1) FM 3600, FM 3611, FM 3810 Nonincendive for Class I Division 2 Groups A, B, C and D. Suitable for Class II Division 2 Groups F and G. Class III Division 1 and 2 Hazardous (Classified) Locations. Temp. Code: T4 Enclosure: NEMA 4X (2) Wiring (Following contents refers DOC. No. NFM008-A13 P.1 and P.2 ) Hazardous(Classified) Location Class I, Division 2 Groups A, B, C, D Associated Apparatus (Note 3) (Note 4) (Note 5) Hazardous(Classified) Location Class I, Division 2 Groups A, B, C, D Model SE14 Magnetic Flow Converter Nonincendive Field Wiring Parameters: Voc Isc Output signal Signal name (V) (ma) Nonhazardous Location Control Equipment (Note 1) Ca (µf) Analog output Current Output 19.7 21.6 0.3 The nonincendive field wiring concept allows interconnection of two FM Approved Nonincendive Apparatuses with nonindendive field wiring parameters not specifically examined in combination as a system when: Voc Vmax, Isc Imax, Ca Ci+C cable, La Li+L cable Input signal Contact output Imax (ma) 135 Ci (µf) 0.1 The nonincendive field wiring concept allows interconnection of two FM Approved Nonincendive Apparatuses with nonindendive field wiring parameters not specifically examined in combination as a system when: Voc or Vt Vmax, Isc or It Imax, Ca Ci+C cable, La Li+L cable NOTE Signal name Transistor Output Vmax (V) 30 La (mh) 10 Li (mh) 0 1. Control equipment connected to the Model SE14 magnetic flow converter must not use or generate more than 250V rms or V dc. 2. Installation should be in accordance with the National Electrical Code ANSI/NFPA 70. 3. The configuration of associated Apparatus must be Factory Mutual Reseach Corporation Approval under Nonincendive Field Wiring Concept or be a simple apparatus (a device which can neither generate nor store more than 1.2V, 0.1A, 25mW, or 20 micro-j, ex. Swiches, thermocouples, LED s and RTD s). 4. Associated Apparatus manufacture s installation drawing must be followed when installing this equipment. 5. Associated Apparatus connection is representative of each input and output signal connection. Each signal shall be wired in a separate shielded cable. 6. No revision to drawing without prior Factory Mutual Reseach Coporation Approval. 12-3

(3) Operation DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE NONHAZARDOUS. NI CLI DIV2, GPS ABCD WITH NONINCENDIVE FIELD WIRING PARAM- ETERS TO CLI DIV2, GPS ABCD PER DWG NFM008-A13 P.1 & P.2.(Refer to (2)) Do not connect BRAIN TERMINAL or HART Communicator in Hazardous locations. will void the approval of Factory Mutual Reseach Corporation. 12. EXPLOSION PROTECTED TYPE INSTRUMENT 12.3 CSA C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5, C22.2 No 25, C22.2 No 30, C22.2 No 94, C22.2 No 1010.1 Certificate: 1221381 Class I, Groups B, C and D; Class II, Groups E, F and G; Class III; Encl Type 4X When installed in Class I, Division 2 locations - Seals No Required. Electrode Circuit: 41V max. 6/6.25Hz Temp. Code: T6 (2) Wiring All wiring shall comply with Canadian Electrical Code Part I and Local Electrical Code. Note a warning label worded as follows. Warning : A SEAL SHALL BE INSTALLED WITHIN 50cm OF THE ENCLOSURE. UN SCELLEMENT DOIT ÉTRE INSTALLÉ À MOINS DE 50cm DU BOÎTIER. (3) Operation Note a warning label worded as follows. Warning : OPEN CIRCUIT BEFORE REMOV- ING COVER. OUVRIR LE CIRCUIT AVANT D EN LEVER LE COUVERCLE. Take care not to generate mechanical spark will void CSA Explosionproof Certification. 12-4

12.4 SAA 12. EXPLOSION PROTECTED TYPE INSTRUMENT AS 2380.1, AS2380.2, AS1939 Certificate:AUS Ex 3764X Type of Protection: Ex d II C T6 Enclosure Type: IP67 Excitation Circuit: 41V max. 6/6.25Hz Temp. Code: T6 (2) Installation All wiring shall comply with local installation requirements and local electrical code. In hazardous locations, the cable entry devices shall be of a certified flameproof type, suitable for the contidions of use and correctrly installed. (3) Operation Open circuit before opening the covers. Take care not to generate mechanical spark will void the certification. 12-5