Compact Multiprotocol I/O Module for Ethernet 8 Universal Digital Channels, Configurable as PNP Inputs or 0.5A Outputs TBEN-S1-8DXP

Similar documents
Compact IP20 Multiprotocol Ethernet I/O Station 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels FEN20-4DIP-4DXP-DIN

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151

Magnetically Actuated Linear Position Sensor WIM100-Q25L-LIU5X2-H1141

Inductive Linear Position Sensor LI200P0-Q25LM0-HESG25X3-H1181

Radio Transmission System Tree topology Ethernet radio DX80ER2M-H

Inductive linear position sensor LI400P0-Q25LM0-LIU5X3-H1151

Inductive angle sensor. 4-wire, analog output. Ri360P1-QR14-ELiU5X2-0,3-RS5. Rectangular, plastic Many mounting possibilities

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM2

Inductive Angle Sensor With Analog Output RI360P1-QR14-ELIU5X2

Radio Transmission System tree topology Data Radio DX80DR2M-H

BL20 Redundant power supply BL20-BR-24VDC-RED

Radio Transmission System Point-to-point node DX80N2X6S-PM8L

Radio Transmission System Star Topology performance gateway (FlexPower) DX80G2M2S-P

Radio Transmission System tree topology Data Radio DX80DR2M-H6

em4 local - Robust Specific characteristics Part number

Your Global Automation Partner. IMX12-DI01 Isolating Switching Amplifier. Safety Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Valve island VS18/VS26 with EtherNet/IP Interface. Operation & Service Manual

7.2 DV1311.L08 and DV1311.L12

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PROFINET USER S GUIDE ACSI Servo

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

Trip amplifier, 1 channel

PHOENIX CONTACT - 03/2007

02/11/2015

em4 em4 alert em4 alert 2G

Table of Contents. HWIO-Gateway User Manual

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Interface Description

02/11/2015

Interface Description

MULTIFUNCTION GRAPHICAL UNIT MGU 800

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

PARAMETER LIST MICROFUSION

PAM & SAM System User s Manual

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0

Data sheet CPU 013C (013-CCF0R00)

Photoelectric Sensors. Manual. True-Color-Sensor with IO-Link. Document number: E Edition C15 Subject to changes.

I/O-System SPEEDWAY. environments outside the control cabinet Degree of protection: IP67 Fully encapsulated

Data Acquisition Modules/ Distributed IO Modules

PHOENIX CONTACT

AI 043 S-DIAS Analog Input Module

Status Indicator LED PWR LINK COL

AC 01.2 Modbus TCP/IP

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

DM 162 S-DIAS Digital Mixed Module

GEMÜ 1242 Electrical position indicator

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

SHF Communication Technologies AG,

SX (400 V) System configuration

CA18CAxxBPxIO - IO-Link

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

Compact Sensors for Retro-reflective Applications

02/11/2015

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Analog Modules AS-i IP20

8V General information. 2 Order data 8V

DeviceNet Connector. Address Switches. Diagnostic LEDs. I/O Connectors. Power Connectors

Sense it! Connect it! Bus it! Solve it! Accessories. Technical features. Inductive angle sensors *D101866ßß0413* QR14 DSU35

PHOENIX CONTACT - 09/2009

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

e 2 TANGO-50 Short-Circuit Detector K Data Sheet

Side view View from below Rear view

SX (690 V) System configuration

Data sheet CPU 313SC (313-5BF13)

CMC 256plus - protection relay test set and universal calibrator

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

CAN-IO Custom IO remote module

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

Characteristics and functioning

Installing the IPS 4240 and the IPS 4255

XIOC technology and networking modules

PD300. Transformer, generator and motor protection Data sheet

Peer Master Example. In This Chapter...

Analog Servo Drive 30A20AC

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

Acceleration sensors With relay output for limit monitoring Analog / CANopen

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

UniStream Remote I/O

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

BCL 500i bar code reader The new generation with a variety of integrated interfaces

Bar code reader BCL 300i The multi-talent with extensive equipment options

Modbus communication module for TCX2: AEX-MOD

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet CPU 314ST/DPM (314-6CF02)

Analog Servo Drive 25A20DD

Optical laser distance sensors. Dimensioned drawing

AxCent Servo Drive A25A100

Rotary Measurement Technology Absolute Encoders, Multiturn

PACSystems* RX3i IC695MDL765

Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified. Number of LEDs. Blank = No LEDs X2 = 2 LEDs

Transcription:

PROFINET device, EtherNet/IP device or Modbus TCP slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2x M8, 4-pin, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics Protection classes IP65, IP67, IP69K M8 connector for power supply, 4-pin Separated power groups for safety shutdown Type designation Ident no. 6814023 Supply Supply voltage Admissible range Voltage supply connection Operating current Sensor/Actuator supply V AUX1 Sensor/Actuator supply V AUX2 24 VDC 18 30 VDC Total current max. 4 A per voltage group Total current V1 + V2 max. 5.5 A at 70 C per module 2 M8, 4-pin V1: max. 150 ma ma Supply ports C0-C3 from V1 short-circuit proof, 0.5 A for group C0-C3 Supply ports C4-C7 from V2 short-circuit proof, 0.5 A for group C4-C7 Electrical isolation galvanic isolation of the voltage groups V1 and V2, voltages up to 500 VAC Input diagnostics by group One freely selectable digital channel per port Max. 0.5A per output Output diagnostics per channel FLC/ARGEE programmable System data Fieldbus transmission rate 10 Mbps/100 Mbps Fieldbus connection technology 2 M8, 4-pin Protocol detection automatic Web server default: 192.168.1.254 Service interface Ethernet via P1 or P2 Field Logic Controller (FLC) Supported from firmware version 3.1.4.0 Released from ARGEE version 2.0.24.0 Modbus TCP Addressing Static IP, BOOTP, DHCP Supported function codes FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, FC23 Number of TCP connections 8 Input register start address 0 (0x0000 hex) Output register start address 2048 (0x0800 hex) EtherNet/IP Addressing acc. to EtherNet/IP specification Quick Connect (QC) < 500 ms Device Level Ring (DLR) Class 3 connections 3 Class 1 connections 10 Input Assembly Instance 103 Output Assembly Instance 104 Configuration Assembly Instance 106 1 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

PROFINET Addressing Conformance class MinCycleTime Fast Start-Up (FSU) Diagnostics Topology detection Automatic addressing Media Redundancy Protocol (MRP) DCP B (RT) 1 ms < 500 ms acc. to PROFINET alarm handling Digital inputs Number of channels 8 Connectivity inputs M8, 3-pin Input type PNP Type of input diagnostics Group diagnostics Switching threshold EN 61131-2 Typ 3, PNP Low level signal voltage < 5 V High level signal voltage > 11 V Low level signal current < 1.5 ma High level signal current > 2 ma Input delay 0.2 ms / 3 ms Electrical isolation galvanic isolation to P1/P2, voltages up to 500 VDC Digital outputs Number of channels 8 Connectivity outputs M8, 3-pol Output type PNP Type of output diagnostics Channel diagnostics Output voltage 24 VDC from potential group Output current per channel 0.5 A, short-circuit proof Load type EN 60947-5-1: DC-13 Short-circuit protection yes Electrical isolation galvanic isolation to P1/P2, voltages up to 500 VDC Standard/Directive conformity Vibration test acceleration to 20 g acc. to EN 60068-2-6 Shock test acc. to EN 60068-2-27 Drop and topple acc. to EN 60068-2-31/IEC 60068-2-32 Electromagnetic compatibility acc. to EN 61131-2 Approvals and certificates CE, FCC UL conditions culus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ. General Information Dimensions (W x L x H) 32 x 144 x 32mm Operating temperature -40 +70 C Storage temperature -40 +85 C Altitude max. 5000 m Protection class IP65 IP67 IP69K MTTF 248 years acc. to SN 29500 (Ed. 99) 20 C Housing material PA6-GF30 Housing color Black Material label Polycarbonate Halogen-free yes Mounting 2 mounting holes 4.6 mm Note the numbering of the IO range: From firmware version 3.1.4.0 and higher slots C0 to C7 and channels CH0 to CH7 are counted. For more details on the corresponding change see manual. 2 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Note It is strongly recommended to use only ready-made Ethernet cables! Ethernet cable (example): M8-M8: ID No. 6630376 PSG4M-0,2-PSG4M/TXN ID No. 6932993 PSGS4M-PSGS4M-4414-1M M8-RJ45: ID No. 6933004 PSGS4M-RJ45S-4414-1M M8-M12: ID No. 6933008 RSSD-PSGS4M-4414-2M M8 x 1 Ethernet Note Actuator and sensor cable/pur cable (example): M8 - open end ID No. 6625562 PSG3M-2/TXL M8-M8 ID No. 6625665 PKG3M-0,3-PSG3M/TXL ID No. 6627137 PKG3M-3-PSG3M/TXL M8 x 1 I/O Port Note Power supply cable (example): M8-M8 ID number 6627044 PKG4M-0,2-PSG4M/TXL ID number 6626679 PKG4M-4-PSG4M/TXL M8 x 1 Voltage Supply 3 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Module LED Status LED Color Status Description ETH1 / ETH2 Green ON Ethernet link (100 Mbps) flashing Ethernet communication (100 Mbps) Yellow ON Ethernet link (10 Mbps) flashing Ethernet communication (10 Mbps) No Ethernet link BUS Green ON Active connection to a master Flashing Steady flashing: Ready Sequence of 3 flashes in 2 seconds: FLC/ARGEE active Red ON IP address conflict or Restore Mode or Modbus timeout Flashing Blink/Wink command active Red/ Green Alternating Waiting for assignment of an IP address, DHCP or BootP Power off ERR Green ON Diagnostics disabled Red ON Diagnostics enabled V 2 undervoltage diagnosis is parameter-dependent PWR Green ON V 1 and V 2 power on Red ON V 2 power off or below defined tolerance of 18 V V 1 power off or below defined tolerance of 18 V LED Status I/O LED Color Status Description LED 0 7 Green ON Input or output active Red ON Output active with overload/short circuit Flashing Overload of the port supply. All LEDs of the affected group C0-C3 or C4-C7 are flashing. Input or output inactive LED 7 White Flashing Blink/Wink command active 4 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Process Data Mapping of the Single Protocols For more details on the corresponding protocols see manual. Modbus TCP Register Addressing (16-bit) Offset Process Input Data: 0x0000, structure acc. to general register mapping Offset Process Output Data: 0x0800: Structure acc. to general register mapping EtherNet/IP TM addressing (16-bit) Process input data (station -> scanner): Status word is located in front of the general process data! Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 GW status 0x0000 - FCE - - CFG COM V1 - V2 - - - - - - Diag Warn 0x0001 Structure according to general register mapping Process output data (scanner -> station): Control word is located in front of the general process data! Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Control 0x0000 reserved 0x0001 Structure according to general register mapping PROFINET: Byte addressing (8-bit) Offset Process Input Data: 0x0000, structure acc. to general register mapping Offset Process Output Data: 0x0000: Structure acc. to general register mapping General Register Mapping Address details are relative. Observe offset of respective protocol Channel Assignment/Port/Pin: Channel - - - - - - - - Ch7 Ch6 Ch5 Ch4 Ch3 CH2 CH1 CH0 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0 Port Pin - - - - - - - - C7 C6 C5 C4 C3 C2 C1 C0 Process Input Data: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 MSB LSB Digital Inputs 8DIP 0x0000 0x0000 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0 Diagnostics 0x0001 0x0002 ERR7 ERR6 ERR5 ERR4 ERR3 ERR2 ERR1 ERR0 - - - - - - VERR VERR V2 V1 CH47 CH03 Latch input 0x0002 0x0004 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0 Counter Ch0 0x0003 0x0006 Counter value LSB 0x0004 0x0008 Counter value MSB Frequency Ch0 0x0005 0x000A Frequency MSB Frequency LSB Status 0x0006 0x000C - - - - - - - - Status PWM Diagnostics 0x0007 0x000E - - - - - - - - - - - - - - - PWM Ch3 OUT ERR PWM Diagnostics 0x0008 0x0010 - - - - - - - - - - - - - - - PWM OUT Ch7 ERR Module Status 0x0009 0x0012 - FCE - - - COM V1 - V2 - - - - - - DIAG Process Output Data: Bit Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 15 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 5 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr MSB ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ LSB more@turck.com ñ www.turck.com

Digital Outputs 0x0000 0x0000 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0 8DXP Latch Reset 0x0001 0x0002 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0 Control 0x0002 0x0004 - - - - - - - - - - - - - - - CNT_ RST PWM Ch3 0x0003 0x0006 - - - - - - - - Duty cycle PWM Ch7 0x0004 0x0008 - - - - - - - - Duty cycle Legend: V1 Undervoltage V1 CFG I/O configuration error V2 Undervoltage V2 FCE I/O-ASSISTANT Force Mode active Cx Port x Px Pin x DIx Digital input channel x DOx Digital output channel x Diag Module diagnostics available ERR x Overcurrent output channel x VERRVxCHyz Overcurrent supply VAUXx channel y to z PWMOUTERR Overcurrent PWM output VERRVxPyCz Overcurrent supply VAUXx, pin y, port z VAUXxPyCz Supply VAUXx, pin y, port z CNT_RST Counter reset 6 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com