MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Similar documents
THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

900 SERIES WALL PANELS

KS42 MF SERIES - HORIZONTAL INSTALLATION

400 SERIES VERTICAL INSTALLATION

DW HORIZONTAL INSTALLATION

DW VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

Insulated Panels North America. Installation Guide KarrierPanel Wall System

~ ~ -

Construction details: Master-C type profiles and joints:

TABLE OF CONTENTS A. PBR

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

REGAL. Installation Manual

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

3M Air and Vapour Barrier 3015 Technical guide

GLOSSARY OF TERMS SECTION 8

TABLE OF CONTENTS A-1

WALL TO FABRICATED FLOOR

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

eco-shake INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

Effective February, 2015

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

System for 2+ Level Buildings

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN


26- H i n g e d P a t i o D o o r s - I n s w i n g

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Vertical Installation and Technical Information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

PROVEN DEPENDABLE SUSTAINABLE

BuildingEnvelope Oldcastle ( ) -

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

Dear Contractor, I am glad that you are interested in our window rebate program.

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION

Series Advanced and alternate. Installation Instructions

GlasRoc Sheathing Type X

COMPOSITE SIDING INSTALLATION GUIDE

Tools required by installer: Materials required by installer:

ForceField Air & Water Barrier System. installation instructions

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

FlexLoc. Technical/Installation Information

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

CFDTT-01. Control Joint Study (General)

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

Integrity Polygon and Round Top Installation and Finishing Instructions

SpeedDeck. Fixing and Handling Guide

Definitions and Design Considerations... W-CR-2

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

Finesse Profiles. Nailstrip

Eagle clad double-hung window installation instructions

Pebbletex Adhered Mat Design. Typical Details

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Norwood Windows Permaglass Fiberglass Products Installation Instruction

Pocket Door Installation Instructions

DuPont Flashing Systems Installation Guidelines. Integral Flanged Door Before water-resistive. Version 2

DuPont Flashing Systems Commercial Installation Guidelines

Storefront Installation Guide

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

GENERAL INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

BBS Rusticated & Splaycut Cavity System

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

GENERAL INSTALLATION GUIDELINES

Ekoroof LiteTile Dimensions

How To Install Windows: Nail-Fin Application

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

Steel Roofing & Siding INSTALLATION GUIDE

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

Dura-Lock Roof System

Site Preparation Information for:

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Cambridge English Application Instructions

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Tuff-Rib Install Guide

Transcription:

KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-BS-05-MTLV KPH-OC-01-MTLV KPH-OC-02-MTLV KPH-IC-01-MTLV KPH-IC-02-MTLV KPH-FO-01-MTLV KPH-FO-02-MTLV KPH-FO-03-MTLV KPH-FO-04-MTLV KPH-PR-01-MTLV KPH-LE-01-MTLV KPH-RD-01-MTLV KPH-TP-01-MTLV KPH-TP-02-MTLV KPH-TL-01-MTLV KPH-TL-02-MTLV C & I DISCLAIMER PANEL PROFILES PANEL PROFILES EXPANDED PANEL JOINT ENGAGED PANEL JOINT INTERMEDIATE SUPPORT VERTICAL JOINT VERT. JOINT BETWEEN STUDS MULTI-STORY FIRE STOPPING DETAIL MULTI-STORY FIRE STOPPING ASSEMBLY MULTI-STORY FIRE STOPPING ASSEMBLY BASE DETAIL FLUSH BASE DETAIL FLUSH W/ EXTRUSION BASE AT NOTCHED CONCRETE BASE AT OVERHANG BASE AT OVERHANG - SINGLE SKIN OUTSIDE CORNER (HIGH CELL) OUTSIDE CORNER (LOW CELL) INSIDE CORNER (HIGH CELL) INSIDE CORNER (LOW CELL) FRAMED OPENING HEAD FRAMED OPENING JAMB (HIGH CELL) FRAMED OPENING JAMB (LOW CELL) FRAMED OPENING SILL PARAPET DETAIL LOW EAVE DETAIL RAKE DETAIL PANEL TERMINATION (HIGH CELL) PANEL TERMINATION (LOW CELL) TRIM END LAP TRIM END LAP WITH HEM INDEX SHEET

DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD. ALL DETAILS ARE BASED ON TYPICAL STUD WALL CONSTRUCTION WITH SINGLE FASTENER. FOR ATTACHMENT TO OTHER WALL SUPPORT SYSTEMS, PLEASE CONTACT KINGSPAN TECHNICAL SERVICES FOR FASTENING RECOMMENDATIONS. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. DISCLAIMER

CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR:REFER TO PROFILE INTERIOR: 26, 24, 22 REVEAL OPTIONS: 1 8 " or 3 8" MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL or HORIZONTAL REVEAL: 3 8" ( 3 8" REVEAL IS REQUIRED FOR ALL KARRIER RAIL APPLICATIONS) EMBOSSING: EXTERIOR: REFER TO PROFILE INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" MALE JOINT 2", 2.5", 3", 4", 5", 6" 3 8 " REVEAL MALE JOINT 2", 2.5", 3", 4", 5", 6" MALE JOINT 2", 2.5", 3", 4", 5", 6" SHADOWLINE INTERIOR KS SHADOWLINE (SL) EXTERIOR SHADOWLINE 26GA, 24GA, 22GA (STUCCO EMBOSSED or SMOOTH) 24", 30", 36", 42" SHADOWLINE INTERIOR KS MICRO-RIB (MR) MICRO-RIB 24GA, 22GA (STUCCO EMBOSSED or SMOOTH) EXTERIOR 24", 30", 36", 42" SHADOWLINE INTERIOR KS MINI MICRO-RIB (MMR) EXTERIOR MINI MICRO-RIB 24GA (SMOOTH ONLY) 24", 30", 36", 42" 3 8 " REVEAL 3 8 " REVEAL FEMALE JOINT FEMALE JOINT FEMALE JOINT PANEL PROFILES

CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR:REFER TO PROFILE INTERIOR: 26, 24, 22 REVEAL OPTIONS: 1 8 " or 3 8" MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL or HORIZONTAL EMBOSSING: EXTERIOR: REFER TO PROFILE INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" MALE JOINT 2", 2.5", 3", 4", 5", 6" 3 8 " REVEAL MALE JOINT 2", 2.5", 3", 4", 5", 6" SHADOWLINE KS AZTECO (AZ) AZTECO 24GA, 22GA (AZTECO EMBOSSMENT ONLY) 24", 30", 36", 42" SHADOWLINE KS MINIWAVE (MW) MINI WAVE 24GA, 22GA (STUCCO EMBOSSED or SMOOTH) 24", 30", 36", 42" INTERIOR EXTERIOR INTERIOR EXTERIOR 3 8 " REVEAL PANEL PROFILES

GYPSUM BOARD VERTICAL SUPPORT AT 16" O.C. FEMALE JOINT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT (OPTIONAL) WALL PANEL INSTALLATION DIRECTION MALE JOINT 1" SET KARRIER RAIL IN BUTYL (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT EXPANDED PANEL JOINT

1" - 3" (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER FOR PROJECTS REQUIRING NFPA 285: INTERIOR SIDE OF FRAMING MUST HAVE 5 8" THICK FIRE BLOCK TYPE X GYPSUM BOARD (NOT BY KINGSPAN) (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT VERTICAL SUPPORT AT 16" O.C. WALL PANEL INSTALLATION DIRECTION FEMALE JOINT MALE JOINT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT (OPTIONAL) SET KARRIER RAIL IN BUTYL (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT 1" ENGAGED PANEL JOINT

GYPSUM BOARD VERTICAL SUPPORT AT 16" O.C. (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER SET KARRIER RAIL IN BUTYL 1" PANEL THICKNESS CONTINUOUS KARRIER RAIL 1 4 " - 14 HEX HEAD FASTENERS W/O WASHER (BELOW) CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS INTERMEDIATE SUPPORT

TRIPLE STUD 5" MIN. VERTICAL SUPPORT CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 5" MIN. OPTIONAL FRAMING (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER SET KARRIER RAIL IN BUTYL 1" PANEL THICKNESS (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CONTINUOUS KARRIER RAIL FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION GYPSUM BOARD VERTICAL JOINT

VERTICAL SUPPORTS AT 16" O.C. CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 1 4 " - 14 HEX HEAD FASTENERS W/O WASHER VERTICAL SUPPORT 1" PANEL THICKNESS (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CONTINUOUS KARRIER RAIL SET KARRIER RAIL IN BUTYL (BELOW) FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION GYPSUM BOARD VERTICAL JOINT BETWEEN STUDS

GYPSUM BOARD FLOOR SLAB, FRAMING AND OTHER MATERIALS KARRIER PANEL INSTALLED HORIZONTALLY FACADE PANEL (INSTALLED VERTICALLY) F.F. 8" MIN COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN 4PSI CONTINUOUS FIRE BLOCKING AT EACH FLOOR LINE INSULATION WASHER AND FASTENERS @ 12" O.C. VOID MULTI-STORY FIRE STOPPING DETAIL

GYPSUM BOARD FASTENING AND OTHER MATERIALS NOT SHOWN FOR CLARITY OF DETAIL KARRIER PANEL INSTALLED HORIZONTALLY KARRIER RAIL NOT SHOWN FOR CLARITY FLOOR SLAB, FRAMING AND OTHER MATERIALS KARRIER RAIL COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN. 4 PSI CONTINUOUS FIRE BLOCKING AT EACH FLOOR LINE INSULATION WASHER AND FASTENERS @ 12" O.C. MAXIMUM 20'-0" O.C. C L C L COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN. 4 PSI CONTINUOUS FIRE BLOCKING AT MAX. 20'-0" O.C. SPACING MULTI-STORY FIRE STOPPING ASSEMBLY

GYPSUM BOARD FASTENING AND OTHER MATERIALS NOT SHOWN FOR CLARITY OF DETAIL FACADE PANEL (INSTALLED VERTICALLY) KARRIER PANEL INSTALLED HORIZONTALLY KARRIER RAIL NOT SHOWN FOR CLARITY FLOOR SLAB, FRAMING AND OTHER MATERIALS COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN. 4 PSI CONTINUOUS FIRE BLOCKING AT EACH FLOOR LINE COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN. 4 PSI CONTINUOUS FIRE BLOCKING AT MAX. 20'-0" O.C. SPACING KARRIER RAIL INSULATION WASHER AND FASTENERS @ 12" O.C. MULTI-STORY FIRE STOPPING ASSEMBLY

SET HAT CHANNEL IN BUTYL VERTICAL SUPPORTS HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL BOTH SIDES OF TRIM WITH 1 1 8" BONDED WASHER BASE FLASHING BELOW BASE FLASHING FASTENER TO CONCRETE BASE CHANNEL SET IN SEALANT GYPSUM BOARD BASE DETAIL FLUSH

SET HAT CHANNEL IN BUTYL VERTICAL SUPPORTS HAT CHANNEL AS REQUIRED 1 4 " - 14 HEX HEAD FASTENERS WITH WASHER SET HAT CHANNEL IN BUTYL FILL VOID WITH COMPRESSIBLE FOAM CLOSURE CONTINUOUS BUTYL SEALANT BELOW BASE EXTRUSION CONTINUOUS BUTYL SEALANT AT PANEL JOINT BASE CHANNEL SET IN SEALANT FASTENER TO CONCRETE ALUMINUM BASE EXTRUSION GYPSUM BOARD BASE DETAIL FLUSH WITH EXTRUSION

SET HAT CHANNEL IN BUTYL VERTICAL SUPPORTS HAT CHANNEL AS REQUIRED BOTH SIDES OF TRIM WITH 1 1 8" BONDED WASHER SET HAT CHANNEL IN BUTYL BASE FLASHING BELOW BASE FLASHING FASTENER TO CONCRETE BASE CHANNEL SET IN SEALANT GYPSUM BOARD BASE AT NOTCHED CONCRETE

SET HAT CHANNEL IN BUTYL VERTICAL SUPPORTS HAT CHANNEL AS REQUIRED BOTH SIDES OF TRIM WITH 1 1 8" BONDED WASHER SET HAT CHANNEL IN BUTYL BASE FLASHING FASTENER TO CONCRETE BASE CHANNEL SET IN SEALANT GYPSUM BOARD BASE AT OVERHANG

SET HAT CHANNEL IN BUTYL VERTICAL SUPPORTS HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL BOTH SIDES OF TRIM WITH 1 1 8" BONDED WASHER BASE FLASHING BELOW BASE FLASHING FASTENER TO CONCRETE BASE CHANNEL SET IN SEALANT GYPSUM BOARD BASE AT OVERHANG SINGLE SKIN

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL OUTSIDE CORNER ASSEMBLY OUTSIDE CORNER TRIM (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CONTINUOUS KARRIER RAIL F.I.P. INSULATION AS REQUIRED (BY OTHERS) FIELD MITER CUT PANELS POP RIVETS (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT VERTICAL SUPPORT GYPSUM BOARD OUTSIDE CORNER (HIGH CELL)

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL OUTSIDE CORNER ASSEMBLY OUTSIDE CORNER TRIM (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CONTINUOUS KARRIER RAIL F.I.P. INSULATION AS REQUIRED (BY OTHERS) FIELD MITER PANELS POP RIVETS (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT VERTICAL SUPPORT GYPSUM BOARD OUTSIDE CORNER (LOW CELL)

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL VERTICAL SUPPORT SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER F.I.P. INSULATION AS REQUIRED (BY OTHERS) 1 4 " - 14 HEX HEAD FASTENERS CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS EXPANSION FASTENER AT KARRIER RAIL (BELOW) OUTSIDE CORNER TRIM INSIDE CORNER TRIM POP RIVETS EXPANSION FASTENER AT KARRIER RAIL (BELOW) CONTINUOUS BUTYL SEALANT AT PANEL JOINT CONTINUOUS KARRIER RAIL INSIDE CORNER ASSEMBLY GYPSUM BOARD CONTINUOUS KARRIER RAIL INSIDE CORNER (HIGH CELL)

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL VERTICAL SUPPORT SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER F.I.P. INSULATION AS REQUIRED (BY OTHERS) 1 4 " - 14 HEX HEAD FASTENERS CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS EXPANSION FASTENER AT KARRIER RAIL (BELOW) OUTSIDE CORNER TRIM INSIDE CORNER TRIM POP RIVETS EXPANSION FASTENER AT KARRIER RAIL (BELOW) CONTINUOUS BUTYL SEALANT AT PANEL JOINT CONTINUOUS KARRIER RAIL INSIDE CORNER ASSEMBLY GYPSUM BOARD CONTINUOUS KARRIER RAIL INSIDE CORNER (LOW CELL)

SET HAT CHANNEL IN BUTYL HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL FRAMED OPENING DRIP FLASHING ASSEMBLY FIELD CUT FEMALE JOINTS WHERE REQUIRED 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER EXPOSED SEALANT DOOR/WINDOW FRAME GYPSUM BOARD FRAMED OPENING HEAD

FRAMED OPENING DOOR/WINDOW FRAME 1 4 " - 14 THROUGH FASTENER SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER SET KARRIER RAIL IN BUTYL EXPOSED SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FIELD CUT PANELS WHERE REQUIRED JAMB FLASHING ASSEMBLY (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT CONTINUOUS KARRIER RAIL GYPSUM BOARD FRAMED OPENING JAMB (HIGH CELL)

FRAMED OPENING DOOR/WINDOW FRAME 1 4 " - 14 THROUGH FASTENER SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER SET KARRIER RAIL IN BUTYL EXPOSED SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FIELD CUT PANELS WHERE REQUIRED JAMB FLASHING ASSEMBLY GYPSUM BOARD CONTINUOUS KARRIER RAIL (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT FRAMED OPENING JAMB (LOW CELL)

EXPOSED SEALANT FIELD CUT MALE JOINTS WHERE REQUIRED SEALANT DOOR/WINDOW FRAME 1 4 " - 14 THROUGH FASTENER SILL TRIM ASSEMBLY SET HAT CHANNEL IN BUTYL 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL GYPSUM BOARD FRAMED OPENING SILL

FIP INSULATION AS REQUIRED PARAPET BLOCKING PARAPET ASSEMBLY WITH 1 1 8" BONDED WASHER WRAP MEMBRANE OVER PANEL FACE SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER FASTENER TO PARAPET BACKER HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER MEMBRANE ROOF & PARAPET BACKER GYPSUM BOARD PARAPET DETAIL

REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION FIP INSULATION AS REQUIRED SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER WITH 1 1 8" BONDED WASHER HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER EAVE STRUT GYPSUM BOARD LOW EAVE DETAIL

REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION RAKE ANGLE FIP INSULATION AS REQUIRED SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER WITH 1 1 8" BONDED WASHER HAT CHANNEL AS REQUIRED SET HAT CHANNEL IN BUTYL SEALANT AT FASTENER GYPSUM BOARD RAKE DETAIL

(2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER STRUCTURAL SUPPORTS CAP TRIM BACKER ROD & SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER CONTINUOUS KARRIER RAIL (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CAP TRIM ASSEMBLY GYPSUM BOARD BACKER ROD AND SEALANT PANEL TERMINATION (HIGH CELL)

(2) 1 4" - 14 HEX HEAD FASTENERS W/O WASHER STRUCTURAL SUPPORTS CAP TRIM BACKER ROD & SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER CONTINUOUS KARRIER RAIL (1) 1 4" - 14 HEX HEAD FASTENER W/O WASHER @ SUPPORT (BELOW) CAP TRIM ASSEMBLY GYPSUM BOARD BACKER ROD AND SEALANT PANEL TERMINATION (LOW CELL)

(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP

FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEMS