Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Similar documents
Performance of 8-stage Multianode Photomultipliers

Pixel hybrid photon detectors

Stato del progetto RICH di LHCb. CSN1 Lecce, 24 settembre 2003

Production of HPDs for the LHCb RICH Detectors

Introduction Test results standard tests Test results extended tests Conclusions

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

The HPD DETECTOR. Michele Giunta. VLVnT Workshop "Technical Aspects of a Very Large Volume Neutrino Telescope in the Mediterranean Sea"

Design, Fabrication and Performance of the 10-inch TOM HPD

PoS(PD07)035. Development of 144 Multi-Anode HPD for Belle Aerogel RICH Photon Detector

The HERA-B Ring Imaging Cerenkov ˇ Detector

Status of the LHCb Experiment

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

CHAPTER 11 HPD (Hybrid Photo-Detector)

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

Total Absorption Dual Readout Calorimetry R&D

Scintillation Counters

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

hybrides à pixels et à leurs applications

5. Scintillation counters

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

HERA-B RICH. Samo Korpar

Measurements With Irradiated 3D Silicon Strip Detectors

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

5. Scintillation counters

Timing and cross-talk properties of BURLE multi-channel MCP PMTs

Performance of High Pixel Density Multi-anode Microchannel Plate Photomultiplier tubes

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

arxiv:hep-ex/ v1 19 Apr 2002

R & D for Aerogel RICH

Studies on MCM D interconnections

SiPMs as detectors of Cherenkov photons

GSPC detectors development for neutron reflectometry and SANS Instruments WP22 / Task 22.2

The Light Amplifier Concept

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group

Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki , Japan

Light Collection. Plastic light guides

PMT Calibration in the XENON 1T Demonstrator. Abstract

High collection efficiency MCPs for photon counting detectors

Timing and cross-talk properties of Burle multi-channel MCP PMTs

Electron-Bombarded CMOS

MCP-PMT status. Samo Korpar. University of Maribor and Jožef Stefan Institute, Ljubljana Super KEKB - 3st Open Meeting, 7-9 July 2009

AMS-02 Anticounter. Philip von Doetinchem I. Physics Institute B, RWTH Aachen Bad Honnef, August 2007

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

Micromegas calorimetry R&D

Ground-based optical auroral measurements

PMF the front end electronic for the ALFA detector

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

combustion diagnostics

Characterization of the Hamamatsu H12700A-03 and R multi-anode photomultiplier tubes

HAPD Status. S. Nishida KEK. Dec 11, st Open Meeting of the SuperKEKB collaboration. HAPD Status. 1st SuperKEKB Meeting 1

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

Diamond sensors as beam conditions monitors in CMS and LHC

Development of New Large-Area Photosensors in the USA

Development of TOP counter for Super B factory

Advancement in development of photomultipliers dedicated to new scintillators studies.

Proximity focusing RICH with flat pannel PMTs as photon detector

Test results on hybrid photodiodes

The LHCb Silicon Tracker

arxiv:physics/ v1 [physics.ins-det] 19 Oct 2001

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Fast Drift CRID with GEM*

Studies of silicon strip sensors for the ATLAS ITK project. Miguel Arratia Cavendish Laboratory, University of Cambridge

The LHCb Vertex Locator (VELO) Pixel Detector Upgrade

1 Detector simulation

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

Guide to SPEX Optical Spectrometer

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Advances in microchannel plate detectors for UV/visible Astronomy

Full characterization tests of Micromegas with elongated pillars

Gamma Spectrometer Initial Project Proposal

Chemistry Instrumental Analysis Lecture 7. Chem 4631

MAROC: Multi-Anode ReadOut Chip for MaPMTs

The CMS Silicon Strip Tracker and its Electronic Readout

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

O.H.W. Siegmund, Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

Simulation studies of a novel, charge sharing, multi-anode MCP detector

RICH2019: A proposal for the LHCb-RICH upgrade

Design and Simulation of a Silicon Photomultiplier Array for Space Experiments

Aberrations of a lens

Calibration of Scintillator Tiles with SiPM Readout

LA BORA TORI NA ZIONA LI DI FRA SCA TI

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Commissioning the LHCb VErtex LOcator (VELO)

Components of Optical Instruments

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PML Channel Detector Head for Time-Correlated Single Photon Counting

Advanced Materials Research Vol

The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance

ITk silicon strips detector test beam at DESY

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

Silicon Photo Multiplier SiPM. Lecture 13

X-ray Scanners* for ATLAS Barrel TRT Modules

High Gain Avalanche Photodiode Arrays for DIRC Applications 1

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

Transcription:

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors F. Muheim a edin]department of Physics and Astronomy, University of Edinburgh Mayfield Road, Edinburgh EH9 3JZ, Scotland/UK a [ The 64-channel Multianode Photo Multiplier (MaPMT) has been evaluated as a candidate for the LHCb Ring Imaging Cherenkov (RICH) photo detectors. We present result from data taken with a 3x3 array of closely packed MaPMTs mounted onto the RICH prototype vessel, exposed to charged particle beams at CERN, and read out at LHC speed. Using a LED light source, we have performed spatial light scans to study the light collection efficiency of the MaPMTs We have also measured the performance of the MaPMTs as a function of the applied high voltage. Different dynode resistor chains have been used to study the tubes at low gains. In addition, we have studied the behaviour of the MaPMT in magnetic fields.. Introduction We have evaluated the 64-channel Multianode Photo Multiplier (MaPMT) as a candidate photo detector for the LHCb Ring Imaging Cherenkov (RICH) counters. The MaPMT contains a 8x8 array of 64 dynode chains enclosed in a single vacuum envelope. The window is made of UV glass instead of borosilicate which extends the transparency down to 2 nm. According to the manufacturer, the bi-alkali photo cathode has a quantum efficiency of 22% at a wavelength of 38 nm. The pitch between anode pixels is 2.3 mm. When accounting for the inactive.2 mm gaps between pixels, the MaPMT has an active area coverage of only 38%. The full angular coverage with 85% active area can be restored by mounting a fused silica lens with one flat and one spherical surface with a radius of curvature of 25 mm in front of the tube. The lens has a demagnification factor of about two-third and focuses the incoming photons onto the sensitive area of the MaPMT. 2. Test Beam Results The sensitivity of the MaPMT to Cherenkov photons has been tested with particle beams of 2 GeV/c pions at the SPS accelerator at CERN. A detailed account of these tests is described in reference []. Here we present the main results. A 3x3 cluster of closely packed MaPMTs has been mounted onto a prototype of the RICH detector for the LHCb experiment. The radiator gas was CF 4 at a pressure of 7 mbar and the photo cathode was set at - V. To demonstrate that the MaPMTs will work at the LHC the data were recorded with the APVm chip running at 4 MHz. Figure. Cherenkov ring measured with the MaPMT array with (right plot) and without lenses (left plot) mounted in front of the tubes. In Figure we show the results for two runs of 6 events each, one with and one without the

2 lenses mounted in front of the MaPMTs. In both cases, a ring of Cherenkov photons is clearly visible. The ratio of yields with and without lenses is.55 as is expected from a simulation. With the lenses the full Cherenkov ring is captured which demonstrates that MaPMTs can be closely packed to restore full geometrical acceptance. We observe 6.96 ±.33 photo electrons per event, in very good agreement with the simulation. The corresponding figure of merit for a RICH detector is N = ± 7cm. In Figure 2 we show bre which could be moved with respect to the MaPMT by semi-automated optical stages. Two read-out systems were employed. One is the 4 MHz read-out with the APVm chip also used for the beam tests, and another one is based on CA- MAC amplifiers and ADCs. In addition to the nine tubes studied with test beams we obtained two more MaPMTs which, according to the manufacturer, have an increased quantum efficiency of maximum 25-27% at 36 nm. The focusing of these new tubes has been improved. Firstly, the acceptance at the outside edges of the active area of the MaPMT has been increased, and another focusing wire has been added. Secondly, the distance between the focusing grid and the entry slits to the dynode chain has been reduced. We have studied these new MaPMTs with a LED light scan. The data have been taken by moving the light source in steps of. mm along the front face of the MaPMT, with the photocathode at -9 V. The Figure 2. MaPMT pulse height spectrum with a superimposed fit (solid line). Also shown is the single photo electron component (dashed line). The vertical line indicates the 5σ cut above pedestal. signal-pedestal [ADC] 6 4 2 8 6 4 2 new focussing old focussing 2 4 6 8 scan across MaPMT surface : [/ mm] the pulse height spectrum for a single pixel. The data were corrected as follows. A common-mode baseline has been subtracted and signals due to cross-talk stemming from the read-out electronics have been removed. We clearly distinguish between the pedestal peak and the signal containing mainly one photo electron. Overlaid is a fit where λ is the mean number of photo electrons. λ-poisson.4.35.3.25.2.5..5 2 4 6 8 scan across MaPMT surface : [/ mm] 3. LED Scans, Signal Shape, Low Gains We have also studied the performance of MaPMTs in the laboratory. As a light source we used a blue LED coupled to a mono-mode fi- Figure 3. Scan across an MaPMT. Shown are the average single photon pulse height s (top) and the mean number of photo electrons λ (bottom) versus the relative position.

3 pulse height spectra have been fit with a Gaussian curve as single photo electron signal shape. Shown in Figure 3 are the average single photon pulse height, s, andλ, the mean number of measured photo electrons as a function of the relative position along the tube. The gain is proportional to s and the collection efficiency is closely related to λ. We observe that the edge pixels have a larger acceptance for the new MaPMT (solid histograms) with respect to the standard focusing tube (dashed histograms). Due to the improved focusing, both the gain and the collection efficiency are more homogeneous. Most front-end chips developed for the LHC have been optimised for signals from Silicon sensors or micro-strip gas chambers with a charge of 26-4 e. At a voltage of 8 V between anode and photocathode the gain of the MaPMT is around 3 which is about times higher. To make use of one of these front-end chips for the the MaPMT a gain adaptation is needed. The preferred solution is to modify a preamplifier to a lower gain. A second possibility is to make use of an attenuator network. This has been used for the APVm read-out by means of an AC coupler. However this approach suffers from cross talk problems. A third way that we have investigated is the feasibility to run the MaPMTs at a lower gain. To reduce the gain of the MaPMT we have changed the values of the resistors between the photo cathode, the first, second and the third dynode, respectively. The basic idea is to keep the gain at the first dynode while lowering the overall gain. The values for the default, a medium and a low gain option are given in Table. The signal width is mainly due to the Poisson distribution for multiplication at the first dynode and can be estimated as g = s 2 /σ 2 where σ is the Gaussian width of the single photon signal. Using the CAMAC read-out we have measured the overall gain of the MaPMT for a center and a border pixel as a function of the high voltage for the three different resistor chains. In Figure 4 top) we plot s as a function of the applied high voltage for the three different resistor chains. At a given voltage the gain of the MaPMT reduces by a factor of four for the low gain option. In the signal-pedestal [ADC] g = signal 2 / width 2 2 MaPMT HV scan : for different resistor chains default gain : 3-2-2--...--2-5 medium gain : 4-2-2--...--2-5 low gain : 4-3-3--...--2-5 center pixel border pixel high gain.65 * medium gain medium gain 2.35 * low gain 75 8 85 9 95 HV [volts] 7 6 5 4 3 2 2 (gain) signal [ADC] Figure 4. High voltage scan for three different resistor chains. Top) Average single photon pulse height s versus high voltage. Bottom) Gain at the first dynode g = s 2 /σ 2 versus s. bottom plot we plot g = s 2 /σ 2 as a function of s. As expected we observe that g increases with s. However there are no differences between the different resistor chains. We have repeated these measurements with the APVm read-out and the results agree. We have studied the loss of signal below the threshold cut of 5 σ ped where σ ped is the Gaussian width of the pedestal peak. We have employed different fit methods. Besides a Gaussian signal shape we have implemented a fit which uses a Poisson distribution for the first two photo electrons [2]. This method also allows for photons which pass through the photo cathode to be converted into photo electrons at the first dynode. A Gaussian or a Poisson fit to the pulse height spectra are inadequate to describe the region of small signals close to the pedestal. In Figure 5 we show a pulse height spectra recorded with the CAMAC read-out and the photo cathode at -9 V. The superimposed fit (dotted line) allows for

4 Table Resistances in [ 2 kω ] in front of each dynode. Dynode 2 3 4 5 6 7 8 9 2 Anode Standard gain 3 2 2 2 5 Medium gain 4 2 2 2 5 Low gain 4 3 3 2 5 Entries / [ADC Count] 3 2 photo electrons to be produced at the first dynode. This fit still does not follow the data points correctly for small signals. There is a broad additional contribution of small pulse heights, but no evidence for a second peak in the data. Including a contribution due to production of photo electrons at the first dynode improves the description of the data. However, the fit improves the overall description of the data and, for the spectrum shown above, yields a gain at the first dynode of K = 6. which is in agreement with expectations whereas the Gaussian and Poisson fit give K g =3.2 andk =4., respectively. The parameter λ is independent of the fit method. Due to gain variations for pixels within a tube the loss of signal below the threshold varies from pixel to pixel. Using the Poisson fit including the st dynode effect gives the most reliable results. The average signal loss of the 64 pixels of an MaPMT is 3%. We have also measured that the signal loss below threshold scales with s. Consequently, running at lower gains increases this loss. 5 5 2 25 3 35 Pulse Height [ADC Counts] Figure 5. MaPMT pulse height spectrum. The overlaid fit is described in the text. 4. Beetle Chip Studies The APVm read-out is not compatible with the LHCb architecture. A possible candidate to read out the MaPMT is the Beetle chip. It can be run in analogue and binary mode. The binary mode has several advantages, as it ties in better with the Pixel HPD development for LHCb, described in reference [3], which also has a binary readout, and for which a design of the Off-Detector Electronics (ODE) is underway. In addition there would be substantial cost savings. A program has been undertaken to develop a Beetle adaptation to the MaPMT. By adding a charge and a voltage attenuator at the input of the preamplifier we have lowered the gain of the Beetle chip. Test structures have been produced and studied for this design. For the charge attenuator, measurements with a test charge agree very well with the simulation. The dynamic range of the preamplifier is photo electrons. This preamplifier has been mounted onto a MaPMT and a pulse height spectrum from an LED light source has been measured. The signal from mostly single photo electrons is nicely separated from the pedestal. In this approach the load ca-

5 pacitance affects the gain which would require to keep the input capacitances of all channels within afewpf. 5. Magnetic Field Studies A consequence of the optimisation of the LHCb spectrometer [3] is that now the RICH photo detectors will be placed in a region where the magnetic field strength is about 4 mt. We have studied the sensitivity of the MaPMT to longitudinal and transverse magnetic fields up to B =35mT. A set-up with 4 LEDs has been built to allow for a diffuse illumination of the MaPMT. The APVm read-out system was used. We observe that the gain and the collection efficiency of a MaPMT decreases with increasing B field. At B = 3 mt, this effect is already sizable for the two edge rows of the tube. Averaged for all pixels of a tube the number of measured photo electrons for B 3 mt is below 9% of that measured at mt. The MaPMT can be shielded by enclosing it laterally with a µ-metal case. This shielding should extend beyond the photo cathode of the tube. In Figure 6 we show the measured number of photo electrons for all pixels of a MaPMT relative to its value at mt for the following set-ups: No shielding,.9 mm thick shielding extending by 3 mm and 2 mm, and.8 mm thick shielding extending by 3 mm and 2 mm. We observe that the shielding of the tube is effective. Already for the single.9 mm thick shielding the MaPMT functions in longitudinal magnetic fields up to mt. We have also studied the behaviour of the MaPMT in transverse fields. These measurements show that the MaPMT is insensitive to transverse magnetic fields up to 25 mt. 6. Conclusions Using particle beams at the SPS at CERN we have successfully tested a 3x3 array of multianode photomultiplier tubes. We have demonstrated that by means of lenses mounted in front of the closely packed MaPMTs the Cherenkov photons are focused onto the sensitive area of the devices. Using a laboratory with LED light sources we have studied the performance and the signal # of entries Total Number of Entries against field.2 no shield 3mm shield 3mm double shield 2mm shield.8 2mm double shield.6.4.2-4 -3-2 - 2 3 4 Field (mt) Figure 6. The number of observed photo electrons relative to B = mt versus magnetic field. shape of the MaPMTs in detail. A change in the focusing of the photo electrons onto the first dynode improved the homogeneity of the gain and of the light collection. The gain and width of the signal as well the signal loss have been measured for voltages between 7 and V. We have demonstrated that running the MaPMT at lower gains significantly increases the signal loss below threshold. Finally, we have evaluated the sensitivity of the MaPMT to longitudinal and transverse magnetic fields up to 35 mt. 7. Acknowledgements I thank Reinhardt Chamonal, Stephan Eisenhardt, and Dave Websdale for the help in preparing this talk. This workshop was dedicated to the memory of Tom Ypsilantis whom I had the privilege to work with. REFERENCES. E. Albrecht et al., Nucl. Instrum. Meth. A 488, (22) -3. 2. I. Chirikov-Zorn et al., Nucl. Instrum. Meth. A 456, (2) 3-324. 3. S. Easo, contribution to these proceedings.