Contents of drawing date SPA30--E-EN Fastening to floor, vertical or horizontal installation 72202 SPA3--E-EN Vertical joint, horizontal installation 72202 605206 SPA3--2E-EN Vertical joint, horizontal installation 72202 605206 SPA3--3E-EN Vertical joint, horizontal installation 72202 605206 SPA32--E-EN Corner, vertical installation 72202 SPA32--2E-EN Corner, horizontal installation 72202 605206 SPA33--E-EN Fastening to roof, horizontal installation 72202 605206 SPA33--2E-EN Fastening to roof, vertical installation 72202 260207 SPA34--E-EN Fireproof door, vertical section 230207 SPA34--2E-EN Fireproof door, horizontal section 230207 City sector type, Name and address Block Site/Reg nr Drawing type Contents of drawing Sandwich panel SPA compartment details Principle details Nr Ruukki Construction Oy Vimpelintie 66 tel +358 2059 27 FI - 62900 ALAJÄRVI fax +358 2059 27700 FINLAND wwwruukkicom Designer 72202 Checked Ruukki Drw nr
vertical or horizontal installation Fastening to floor, vertical section date 72202 SPA30--E-EN Ruukki :2,5 SPA30--E-ENdwg 3 0 255 00 Sandwich panel SPA, vertical or horizontal installation 0 /EAFC/ Fastening corner flashing Flashing screw c/c 300 mm 255 Spike-fastener 3 /EAWS30565/ Mineralwool
horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--E-EN A Ruukki A :4 SPA3--E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--2E-EN A Ruukki A :4 SPA3--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 Every fifth panel in vertical direction and panels above the openings are attached to the frame using through-fixings 2 22 3 32 3 50 40 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 2 /EA6FP / Fastening plate 3 /EAR8/ Cover flashing 22 Internal thread socket + hex bolt Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--3E-EN A Ruukki A :4 SPA3--3E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
vertical installation Corner, horizontal section date 72202 SPA32--E-EN Ruukki :2,5 SPA32--E-ENdwg 3 5 46 00 Sandwich panel SPA, vertical installation 46 /EAEC9- / External corner flashing 5 /EAIC2/ Internal corner flashing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool
horizontal installation Corner, horizontal section date 72202 605206 SPA32--2E-EN A Ruukki A :4 SPA32--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 3 32 58 20 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 58 /EAR23/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
horizontal installation Fastening to roof, vertical section date 72202 605206 SPA33--E-EN A Ruukki A :4 SPA33--E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 255 58 32 00 Sandwich panel SPA, horizontal installation 58 /EAR23/ Cover flashing Flashing screw c/c 300 mm 255 Spike-fastener /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
vertical installation Fastening to roof, vertical section date 72202 260207 SPA33--2E-EN B Ruukki B :4 SPA33--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 255 52 02 255 32 32 00 Sandwich panel SPA, horizontal installation 02 /EAFC5/ L-corner 52 /EAR2/ Roof flashing Flashing screw c/c 300 mm 255 Spike-fastener /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool
230207 Ruukki :2 date Contents of drawing horizontal or vertical installation Fireproof door, vertical section SPA34--E-EN Note! This detail apply to 2x2 door For larger openings, there must be frame which is supported by load bearing frame Door frame must meet the wall fire resistance requirement Door opening must be reinforced with 6 mm U-profile around Corners, upper part and side parts must be attached together with bolt M8 Door fastening according to door manufacturers instruction The gap between door and U-profile must be insulated with fireproof mineral wool 00 003 005 002 007 004 008 007 006 00 Sandwich panel SPA 002 U-profile, t = 6 mm S355 003 Cover flashing, t = 06 mm, according to project 004 Cover flashing, t = 06 mm, according to project Flat head flashing fastener /EA3SS40/ Sealing strip 005 Bolt M8 88 k400 006 Expanding fire sealing 007 Fire protection wool 008 Fire protection wool Copyright Ruukki Construction Oy Allowed only for designs with Ruukki's products
230207 Ruukki :2 date Contents of drawing horizontal or vertical installation Fireproof door, horizontal section SPA34--2E-EN Note! This detail apply to 2x2 door For larger openings, there must be frame which is supported by load bearing frame Door frame must meet the wall fire resistance requirement Door opening must be reinforced with 6 mm U-profile around Corners, upper part and side parts must be attached together with bolt M8 Door fastening according to door manufacturers instruction The gap between door and U-profile must be insulated with fireproof mineral wool 007 003 008 006 007 00 Sandwich panel SPA 002 U-profile, t = 6 mm S355 003 Cover flashing, t = 06 mm, according to project 004 Cover flashing, t = 06 mm, according to project Flat head flashing fastener /EA3SS40/ Sealing strip 005 Bolt M8 88 k400 006 Expanding fire sealing 007 Fire protection wool 008 Fire protection wool 005 002 004 00 Copyright Ruukki Construction Oy Allowed only for designs with Ruukki's products