Drawing nr. Contents of drawing Date Rev. date

Similar documents
Sandwich panel Compartment details, ceiling PRINCIPLE DETAILS 1:1

SANDWICH PANEL SPA INSTALLATION INSTRUCTIONS

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

ASSEMBLY INSTRUCTION CONTENT

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

The General Principles of Detailed Design at Ruukki Construction Ltd. Julia Piiroinen

OWNER S MANUAL STORAGE SHED MODELS: STOR-96-G-W-1RH & STOR-912-G-W-1RH

32 Gallon Perforated Square Receptacle

KS42 MF SERIES - HORIZONTAL INSTALLATION

HIGH RISE Portable Restroom Assembly Instructions

Instructions for Installation on a Flat Roof

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

900 SERIES WALL PANELS

ROCKWELL 4-IN-1 DOOR. Two Panel Door. Half X Door. Z Combination Door. Double X Door

GLOSSARY OF TERMS SECTION 8

MECHANICAL BACK FASTENED SYSTEMS INSTALLATION DATA

GENERAL INSTALLATION INSTRUCTIONS FOR SMU TYPE METAL DOORS AND SMU HATCH USE OF DOORS

FRP GATES MM08 FRP GATES Rev. 3 COMPOSITE SOLUTION PAGE 1

INSTALLATION GUIDE Locker With Top Shelf Transit Low Roof & Nissan NV Low Roof ( Aluminum )

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

Titan Series Awning Assembly and Installation Instructions

Boxed Shed. QUAKER or A-FRAME SIZES: 6 x 8 6 x 10 T1-11Siding

DOCK WEDGE - STANDARD

Heavy-Duty Bypass Track System

FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Assembly Instructions

Installation Instructions

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

FREEDOM 2 PORTABLE RESTROOM ASSEMBLY INSTRUCTION

Bulkhead Model Number and

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

GlasRoc Sheathing Type X

Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760

Wall mounting with holding profile

WALL TO FABRICATED FLOOR

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H

Pacifica / DLG-52(E) Shower Cabin Installation and User s Guide

Leveling Feet, Base Plates and Casters

INSTALLATION MANUAL FORTRESS SERIES

Small Projection port, Small View port Installation procedure

Safety Glasses Safety Gloves Ladders Measuring Tape Spirit Level String Line. Tin-Snips Rivet Gun Caulking Gun Silicone Socket Set

11 6 Round Building Assembly Instructions

FW / FIG Partition Kit(s) Installation Instructions

S H E D A S S E M B L Y I N S T R U C T I O N S

NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS

ATTACH WALL PLATE TO WALL

Segmented Transfer Plate Installation Instructions

Enclosed Partition Installation Instructions

400 SERIES VERTICAL INSTALLATION

Installation Instructions for Vista Air Vertically Folding Walls

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

Side DuraRac Installation Instructions

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

STRUCTURAL HOLDING, F150 TOOL BOARD, AND CART ASSEMBLY

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H

Desk/Wall-Mount Rack

Assembly Instructions 10 X 10 Aluminum Roof Support

Innova. Concealed frame doorsets. Installation instructions

CFDTT-01. Control Joint Study (General)

KS SERIES - VERTICAL INSTALLATION

INSTALLATION INSTRUCTIONS

A Generic Sauna Room Assembly Manual

How To Install Windows: Nail-Fin Application

Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

MAKO TM CASH DISPENSER

Assembly Instructions 10 X 10 Aluminum Frame Building

Required Tools: Suggested Additional Tools: 1 Cordless Drill with Robertson Bits 1 Ratchet Wrench 1 7/16 or 11mm socket 1 7/16 or 11mm Gear Wrench

INSTALLATION GUIDE N5-DS48-4

INSTRUCTION SHEET U19

Assembly Instructions

Bunk Pod Front Entry Assembly Instructions

Sliding Door Kit

CHICKEN COOP & CHICKEN RUN. Tools required for assembly (not included)

Locker Pedestal Installation Instructions

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

REHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES. Building Solutions Automotive Industry

Independent Containment System (ICS)

CSS Central Mount System

Assembly instructions. NL2320 Deco outdoor sauna

ROCKWELL. Two Panel Door. Half X Door. Double X Door. Z Combination Door

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

INSTALLATION GUIDE FTX FLOOR Ford Transit ( 148" Extended Wheelbase )

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

Medium HoneyBadger Chase Rack Installation Instructions

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

Bike Locker Model DBL1 & DBL2

DuraRac Shelving System

Simotec. 13.i

Therma-Tru Door Gallery Setup Instructions Swing Unit with Hardware Kit - Hardware Part # MADGSWU15 (Swing Unit) Part # MADGHKSU10 (Hardware Kit)

40670 Transit Connect/NV200/City Express/ProMaster City Partition

Designed for flexibility... Engineered to last. CYCLE-SAFE / TWO-TIERED INSTALLATION

Triple Bypass System

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

Transcription:

Contents of drawing date SPA30--E-EN Fastening to floor, vertical or horizontal installation 72202 SPA3--E-EN Vertical joint, horizontal installation 72202 605206 SPA3--2E-EN Vertical joint, horizontal installation 72202 605206 SPA3--3E-EN Vertical joint, horizontal installation 72202 605206 SPA32--E-EN Corner, vertical installation 72202 SPA32--2E-EN Corner, horizontal installation 72202 605206 SPA33--E-EN Fastening to roof, horizontal installation 72202 605206 SPA33--2E-EN Fastening to roof, vertical installation 72202 260207 SPA34--E-EN Fireproof door, vertical section 230207 SPA34--2E-EN Fireproof door, horizontal section 230207 City sector type, Name and address Block Site/Reg nr Drawing type Contents of drawing Sandwich panel SPA compartment details Principle details Nr Ruukki Construction Oy Vimpelintie 66 tel +358 2059 27 FI - 62900 ALAJÄRVI fax +358 2059 27700 FINLAND wwwruukkicom Designer 72202 Checked Ruukki Drw nr

vertical or horizontal installation Fastening to floor, vertical section date 72202 SPA30--E-EN Ruukki :2,5 SPA30--E-ENdwg 3 0 255 00 Sandwich panel SPA, vertical or horizontal installation 0 /EAFC/ Fastening corner flashing Flashing screw c/c 300 mm 255 Spike-fastener 3 /EAWS30565/ Mineralwool

horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--E-EN A Ruukki A :4 SPA3--E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--2E-EN A Ruukki A :4 SPA3--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 Every fifth panel in vertical direction and panels above the openings are attached to the frame using through-fixings 2 22 3 32 3 50 40 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 2 /EA6FP / Fastening plate 3 /EAR8/ Cover flashing 22 Internal thread socket + hex bolt Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

horizontal installation Vertical joint, horizontal section date 72202 605206 SPA3--3E-EN A Ruukki A :4 SPA3--3E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

vertical installation Corner, horizontal section date 72202 SPA32--E-EN Ruukki :2,5 SPA32--E-ENdwg 3 5 46 00 Sandwich panel SPA, vertical installation 46 /EAEC9- / External corner flashing 5 /EAIC2/ Internal corner flashing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool

horizontal installation Corner, horizontal section date 72202 605206 SPA32--2E-EN A Ruukki A :4 SPA32--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 20 3 32 3 3 32 58 20 50 30 20 Fire protection of column according to structural designer 00 Sandwich panel SPA, horizontal installation 3 /EAR8/ Cover flashing 58 /EAR23/ Cover flashing 20 Self-drilling panel screw, washer with sealing Flashing screw c/c 300 mm /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

horizontal installation Fastening to roof, vertical section date 72202 605206 SPA33--E-EN A Ruukki A :4 SPA33--E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 255 58 32 00 Sandwich panel SPA, horizontal installation 58 /EAR23/ Cover flashing Flashing screw c/c 300 mm 255 Spike-fastener /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

vertical installation Fastening to roof, vertical section date 72202 260207 SPA33--2E-EN B Ruukki B :4 SPA33--2E-ENdwg Fire protection wool FPS 7, thickness (mm) Structure EI60 EI90 EI20 EI80 EI240 255 52 02 255 32 32 00 Sandwich panel SPA, horizontal installation 02 /EAFC5/ L-corner 52 /EAR2/ Roof flashing Flashing screw c/c 300 mm 255 Spike-fastener /EA3SS40/ Sealing band 3 /EAWS30565/ Mineral wool 32 /EAFW20600200/ Fire protection wool

230207 Ruukki :2 date Contents of drawing horizontal or vertical installation Fireproof door, vertical section SPA34--E-EN Note! This detail apply to 2x2 door For larger openings, there must be frame which is supported by load bearing frame Door frame must meet the wall fire resistance requirement Door opening must be reinforced with 6 mm U-profile around Corners, upper part and side parts must be attached together with bolt M8 Door fastening according to door manufacturers instruction The gap between door and U-profile must be insulated with fireproof mineral wool 00 003 005 002 007 004 008 007 006 00 Sandwich panel SPA 002 U-profile, t = 6 mm S355 003 Cover flashing, t = 06 mm, according to project 004 Cover flashing, t = 06 mm, according to project Flat head flashing fastener /EA3SS40/ Sealing strip 005 Bolt M8 88 k400 006 Expanding fire sealing 007 Fire protection wool 008 Fire protection wool Copyright Ruukki Construction Oy Allowed only for designs with Ruukki's products

230207 Ruukki :2 date Contents of drawing horizontal or vertical installation Fireproof door, horizontal section SPA34--2E-EN Note! This detail apply to 2x2 door For larger openings, there must be frame which is supported by load bearing frame Door frame must meet the wall fire resistance requirement Door opening must be reinforced with 6 mm U-profile around Corners, upper part and side parts must be attached together with bolt M8 Door fastening according to door manufacturers instruction The gap between door and U-profile must be insulated with fireproof mineral wool 007 003 008 006 007 00 Sandwich panel SPA 002 U-profile, t = 6 mm S355 003 Cover flashing, t = 06 mm, according to project 004 Cover flashing, t = 06 mm, according to project Flat head flashing fastener /EA3SS40/ Sealing strip 005 Bolt M8 88 k400 006 Expanding fire sealing 007 Fire protection wool 008 Fire protection wool 005 002 004 00 Copyright Ruukki Construction Oy Allowed only for designs with Ruukki's products