Nanotechnology Solutions Partner

Similar documents
The World s Most Accurate AFM System. Park NX-3DM Innovation and Efficiency for 3D Metrology.

Park NX20 The leading nano metrology tool for failure analysis and large sample research.

The Most Accurate Atomic Force Microscope. Park XE15 Power and versatility, brilliantly combined.

Advanced Nanoscale Metrology with AFM

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

The Most Accurate Atomic Force Microscope. Park NX20 The leading nano metrology tool for failure analysis and large sample research.

Park XE7 The most affordable research grade AFM with flexible sample handling.

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Park NX10. The most accurate and easiest to use Atomic Force Microscope.

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Manufacturing Metrology Team

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Nanosurf easyscan 2 FlexAFM

PICO MASTER 200. UV direct laser writer for maskless lithography

Zeta-300 3D OPTICAL PROFILER

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Akiyama-Probe (A-Probe) guide

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

TECHNICAL DATA. OPTIV CLASSIC 322 Version 3/2013

Akiyama-Probe (A-Probe) guide

M-041 M-044 Tip/Tilt Stage

This is how PI Does Measuring - Part I

Nanosurf Nanite. Automated AFM for Industry & Research.

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

TECHNICAL DATA OPTIV CLASSIC 432

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

OPTIV CLASSIC 321 GL TECHNICAL DATA

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Comparison of resolution specifications for micro- and nanometer measurement techniques

Zeta-20. Zeta3D OPTICAL PROFILER IMAGING THE IMPOSSIBLE

V2018 SPINSTAND AND NEW SERVO-8 SYSTEM

Motion Solutions for Digital Pathology

Motion Solutions for Digital Pathology. White Paper

LVEM 25. Low Voltage Electron Microscope Fast Compact Powerful.... your way to electron microscopy

Profile Measurement of Resist Surface Using Multi-Array-Probe System

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

SENSOR+TEST Conference SENSOR 2009 Proceedings II

SUPRA Optix 3D Optical Profiler

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Enabling Areal Density Growth

MEASUREMENT APPLICATION GUIDE OUTER/INNER

The Fastest, Easiest, Most Accurate Way To Compare Parts To Their CAD Data

ATOMIC FORCE MICROSCOPY

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

Oxford Scholarship Online

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

P-611.Z Piezo Z-Stage

MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Surface Finish Measurement Methods and Instrumentation

Lecture 20: Optical Tools for MEMS Imaging

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

Fiber Optic Device Manufacturing

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

Low Voltage Electron Microscope

CD-SEM for 65-nm Process Node

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

Y.MU 2000 Precise inspection results for sampling and 100% inspection

Low Voltage Electron Microscope. Nanoscale from your benchtop LVEM5. Delong America

Low Voltage Electron Microscope

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Bringing Answers to the Surface

Figure for the aim4np Report

LOW TEMPERATURE STM/AFM

Introduction of New Products

v tome x m microfocus CT

L100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION

Engineered Systems LEADING AUTOMATION SOLUTIONS FOR MOTION & POSITIONING

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

ROTATIONALLY SYMMETRICAL WORKPIECES

Wafer Loaders for IC Inspection Microscopes NWL200 Series. Wafer Loaders for IC Inspection Microscopes

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

Correlation of Wafer Backside Defects to Photolithography Hot Spots Using Advanced Macro Inspection

Scanning Ion Conductance Microscope ICnano

A Laser-Based Thin-Film Growth Monitor

Compact Nanopositioning System Family with Long Travel Ranges

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

Specifying and Measuring Nanometer Surface Properties. Alson E. Hatheway

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Indian Institute of Technology Bombay

Zeta-20. 3D Optical Profiler

Predictive manufacturing with a new generation

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

Keysight 9500 AFM. Data Sheet

Ultrasonic Fine Wirebonder

Transcription:

Nanotechnology Solutions Partner Park Systems Corp. KANC 4F, Iui-Dong 6-10, Suwon, Korea 443-270 Tel. +82-31-546-6800 Fax. +82-31-546-6805 www.parkafm.co.kr Park Systems Inc. 3040 Olcott St. Santa Clara, CA 95054 Tel. +1-408-986-1110 Fax. +1-408-986-1199 www.parkafm.com Park Systems Japan. NK Dai-ichi Bldg. 1F 1-17-1 Kanda-Nishikicho, Chiyoda-ku, Tokyo, 101-0054 Japan Tel. +81-3-3219-1001 Fax. +81-3-3219-1002 www.parkafm.co.jp Park Systems Singapore. 33, Ubi Avenue 3, #07-47 Vertex Tower A Singapore 408868 Tel: +65-6634-7470 Mobile: +65-9821-8868 www.parkafm.com

Decoupled XY & Z Scanners PROBLEMS As the dimensions of device structures continue to decrease and newer 3D structures emerge, the methods for critical dimension metrology are no longer adequate to characterize process variables. For the traditional techniques such as CD-SEM, OCD, and FIB/SEM, the limitations are becoming more apparent. For example, due to the sidewall roughness, the CD-SEM does not provide a clear definition at the structure edge, the OCD only provides an average value of the critical dimension, and the FIB/SEM provides only a single point measurement and does not provide a complete picture of the structure dimensions. Automated Industrial AFM for High-Resolution 3D Metrology PARK SYSTEMS SOLUTION Park Systems provides a reference metrology system for the critical dimension and sidewall analysis. As a fully automated AFM system, the 3DM allows for sidewall, undercut, and line/trench width characterization. With our True Non-Contact Mode, our is capable of imaging the most challenging structures such as soft photoresists and 3D multilayer topologies. BENEFIT The provides the unique advantage of a non-destructive in-line imaging tool capable of providing a) high resolution, b) direct, and c) repeatable measurements with complete three dimensional information for lines, trenches, and multilayer 3D devices. Park Systems has introduced the revolutionary, the completely automated AFM system designed for overhang profiles, high-resolution sidewall imaging, and critical angle measurements. With the patented decoupled XY and Z scanning system with tilted Z-scanner, it overcomes the challenges of the normal and flare tip methods in accurate sidewall analysis. In utilizing our True Non-Contact Mode, the enables non-destructive measurement of soft photoresist surfaces with high aspect ratio tips. 1 High Resolution Access to Undercut and Sidewall Unique decoupled XY and Z scanning system with tilted Z scanner Z-scanner is tilted sideways from -19 to +19 degrees and -38 to +38 degrees Use of normal high aspect ratio tips for high resolution imaging XY scan of up to 100 μm x 100 μm Up to 25 um Z scan range by high force scanner 2 Complete 3D Metrology of Sidewall Sidewall roughness measurement Critical angle measurement of sidewalls Critical dimension measurements of vertical sidewalls 3 Non-destructive CD and Sidewall Measurements by True Non-Contact Mode In-line measurement of the smallest features in the industry. Non-destructive measurement of soft photoresist Less tip wear for prolonged high-quality and high-resolution imaging Immunity from parameter-dependent results observed in tapping imaging 4 High-Throughput Inline Automation Automatic measurement and analysis of trenches, overhangs, and undercuts Cleanroom compatibility and remote control interface Automatic tip exchange (optional) Equipment Front End Module (EFEM) for wafer handling (optional) 5 Nanotechnology Solutions Partner Partnering with customers to meet the fast changing requirements Flexible software and hardware modifications to the modular platform Enable rapid response to customers' needs 02-03 -

APPLICATION FEATURES Tilted Z-scan System Z-SCANNER CANTILEVER SAMPLE XY-SCANNER TILTED Z-SCANNER XY-SCANNER SAMPLE The unique design of the is made possible by deliberately and independently tilting the Z-scanner in its patented Crosstalk Eliminated (XE) AFM platform where XY and Z scanners are completely and independently decoupled. It allows users to access the vertical sidewalls as well as undercut structures at various angles. Unlike systems with flared tips, high resolution and high aspect ratio probes can be used. CD Measurements of Undercut & Overhang s Z-head tilting mechanism allows an unique access to the undercut and overhand structures of photoresist. Fully Automated Pattern Recognition Utilizing a powerful combination of high resolution digital CCD camera and pattern recognition software, a fully automated pattern recognition and alignment is made possible for user applications. Top (A) Sidewall (B) A B Bottom (C) C Automatic Measurement Control High-Resolution Sidewall Roughness s Z-head tilting mechanism allows access to the sidewalls using an ultra sharp tip to obtain high resolution and details of the sidewall roughness. Automated software makes the operation effortless. Measurement recipes provide multi-site analysis with optimized settings for cantilever tuning, scan rate, gain, and set point parameters. Industry s Lowest Noise Floor To detect the smallest sample features and image the flattest surfaces, Park Systems has engineered instruments which hold the industry s lowest noise floor specification of < 0.5Å. Noise floor data is determined using a zero scan. With the cantilever in contact with the sample surface, the system noise is measured at a single point under the following conditions: pxl CD Measurements of Photoresist Trench 0 nm x 0 nm scan, staying in one point 0.5 gain, in contact mode 256 x 256 pixels Unique True Non-Contact mode enables nondestructive in-line measurement of etch features as small as 45 nm. 04 l 05 - Decoupled XY & Z Scanners

20 40 60 ( CROSSTALK ELIMINATION ( XE ACCURATE AFM RESULTS BY CROSSTALK ELIMINATION (XE) Challenges of Accurate AFM Measurement Artifact Free Imaging A Software flattening leaves residual bow Artifact Free Imaging: Flat XY Scan Without Scanner Bowing The conventional AFM uses a piezoelectric tube for the x-y-z scanner, where x-y motion relies on the bending of the tube. The bending motion, however, introduces background curvature and therefore causes z position errors. Conventional systems regularly use software flattening to hide the background curvature; this can be an impossible task since the amount of curvature depends not only on scan size and scan speed, but also on x-y offset, z position, etc. Therefore, even after software flattening, a flat surface does not look flat as shown in the figure. Feedback Control Low residual bow Results less dependent on scan location Less than 1 nm No need for software processing (raw data) Accurate height measurements and sample imaging Flat XY Scan Without Scanner Bowing The Crosstalk Elimination (XE) fundamentally removes the scanner bowing, hence attaining flat XY scan with out-of-plane motion less than 1 nm regardless of scan locations, scan rates, and scan sizes. It shows no background curvature even on scans of the flattest samples such as that of an optical flat as shown in the figure, also with various scan offsets. Thus, the XE-AFM enables very accurate height measurement and precision nanometrology for the most challenging problems in research and industry. Laser PSPD Highly Linear and Orthogonal XY Scan Mirror Sample Cantilever Non-destructive Scan: Tip and Sample Preservation by Non-Contact AFM A B E C D D 100nm Standard (5 x 5 μm scan) 4,096 x 4,096 pixel image The flexure XY scanner decouples the X and Y scan motion so that the coupling between X and Y movement is minimized regardless of scan locations, scan rates, and scan sizes. Position sensors provide linear feedback control for the high accuracy and high precision measurements. X-Y-Z Piezo Tube Scanner X Y -X Z X-Y Scan Control The tube scanner is a slow actuator with highly limited Z-scan bandwidth of only 500 Hz or so. Therefore, the Z-servo response is too slow to implement Non-Contact Mode, a critical requirement for preservation of sharp tips and non-destructive imaging of soft biological samples. Non-destructive Scan Less tip wear for prolonged high-resolution imaging Minimized sample damage or modification Immunity from parameter-dependent results Imaging of soft sample surface XE Technology: Park Systems Answer to Accurate AFM Measurement Challenges of accurate AFM measurement calls for a completely new approach in the design of an AFM. Park Systems developed the Crosstalk Eliminated (XE) AFM based on decoupled flexure scanners where the XY scanner only moves the sample and the Z Scanner drives the probe. The XE-AFM fundamentally removes the scanner bowing, hence attaining flat XY scan, and dramatically improves the Z-servo response, resulting in superb tip preservation by True Non-Contact Mode. Mechanical Design Features Advantages Decoupled XY and Z Scanners 2D XY Flexure Scanner High Force Z Scanner Super Luminescent Diode (SLD) 06 l 07 - Decoupled XY & Z Scanners XY scanner only moves the sample and the Z scanner drives the probe Minimal Z Runout (Out-of-plane Motion) Large Z Servo Bandwidth Low Optical Coherence Flat XY Scan Without Scanner Bow Highly Linear and Orthogonal XY Scan Enabling True Non-Contact Mode Eliminates Optical Interference True Non-Contact Mode is Now a Reality True Non-Contact Mode, one of the distinctive advantages only realized by Park Systems Crosstalk Eliminated (XE) AFM, is a powerful method that enables AFM users to image and measure samples. Longer Tip Life and Less Sample Damage The sharp end of an AFM tip is so brittle that once it touches a sample, it becomes instantly blunt and limits the resolution of an AFM and reduces the quality of the image. U Contact Mode Non-Contact Mode z Distance, Z Repulsive Attractive Total interaction In True Non-Contact Mode, the tip-sample distance is successfully maintained at a few nanometers in the net attractive regime of inter-atomic force. The small amplitude of tip oscillation minimizes the tip-sample interaction, resulting in superb tip preservation and negligible sample modification. µm 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 XE-AFM 0 2.5 5 7.5 10 12.5 µm 3.7 μm Before After taking 20 images For softer samples, the tip will damage the sample and also result in inaccuracies of sample height measurements. Consequently, preserving tip integrity enables consistent high resolution and accurate data. True Non-Contact Mode of the XE-AFM superbly preserves the tip, resulting in much longer tip life and less sample damage. The figure, displayed in 1:1 aspect ratio, shows the unprocessed raw data image of a shallow trench isolation sample imaged by the XE-AFM, whose depth is also confirmed by scanning electron microscope (SEM). The same tip used in the imaging of the sample shows no tip wear even after taking 20 images.

AFM SOLUTIONS PARK SYSTEMS RELIABILITY Semiconductor With its ability to accurately measure critical dimensions in the micrometer to nanometer regime, Atomic Force Microscope (AFM) is becoming the tool of choice for applications involving surface roughness, trench depth, and line width characterization of various samples features and materials. Sample Range UCL Gage Repeatability and Reproducibility Due to the ever-decreasing size of components, manufacturers now require the highest level of quality control. Park Systems can provide 1 gage sigma (σ) of less than 1 Angstrom. Accuracy Part LCL Throughput Cost Effectiveness Correlation Thanks to its revolutionary platform designed for industrial metrology, the XE-AFM will correlate with any existing Park industrial AFMs that have been previously used for manufacturing, inspection, analysis, or research. System 2 R2 > 0.95 0.95 < Slope < 1.05 Accuracy Like Never Before System 1 Shrinking form factors are driving the need to design at the nanoscale level in the semiconductor markets. Traditional metrology tools have lacked the accuracy needed for nanoscale design and manufacturing. Park Systems has met this challenge in industrial metrology with enabling breakthroughs. Crosstalk Elimination (XE) enables artifact-free and non-destructive imaging New 3D AFM enables high resolution imaging of sidewall or undercut features Throughput Like Never Before AFMs that have enabled nanoscale design have traditionally not been fast enough for use in production quality control. All that has changed with Park Systems revolutionary gains in throughput enabling AFMs for use in automatic in-line manufacturing. System Uptime Our engineers and scientists adopted the most rigorous industry standard of product development to ensure the highest level of system reliability. The can be seamlessly incorporated as either an inline or offline inspection tool with minimal maintenance requirements. These include automatic tip exchange where our novel magnetic approach has a 99% success rate, higher than traditional vacuum techniques. Also, full access to raw data and a true partnership with customers are required for any process and throughput optimization. Cost-Effectiveness Like Never Before Accuracy and throughput in nanometrology must be delivered in a cost-effective solution to move successfully from research to inline manufacturing. Park Systems have met this cost challenge with industrial AFM solutions that address the need for faster, efficient automation and longer tip life. We cut costs by replacing slower and expensive SEM with efficient, automatic, and affordable 3D AFM for industrial in-line manufacturing. To pinpoint defects in new designs, manufacturers today need 3D information to characterize trench profiles and sidewall feature variation. Modular AFM platform allows rapid software and hardware changes, enabling cost-effective upgrades and better optimization for the most complex and demanding measurements in production quality control. Also, we lower the cost of ownership with at least 200% longer AFM tip life. The tapping forces of conventional AFMs cause faster tip wear, but our True Non-Contact Mode AFMs maintain tip quality resulting in the lower total cost of ownership. Service & Maintenance Park Systems is committed to the highest level of service and support, and every effort is made to understand our industrial customers needs. We place the utmost importance on meeting promised delivery dates, guaranteed quality, and faithful after-sales service. 08 l 09 - Decoupled XY & Z Scanners

XEA & OPTIONS SPECIFICATIONS Software & User Interface Footprint XEA - Industrial Automation & Analysis XEA is a system software for automation that carries out the AFM measurement of a sample following the preset procedure written in a recipe file. User-friendly XEA architecture provides flexibility to operator to perform various system-wide functions. Minimum 3320 mm 600 940 880 600 300 Supports auto, semi-auto, and manual mode Editable measurement method for each automated procedure Live monitoring of the measurement process Automatic analysis of acquired measurement data XEP Data Acquisition All the user controls on AFM measurements are operated through XEP, the data acquisition program. The user-oriented interface provides easy operation of AFM. Simultaneous data acquisition of up to 16 images Maximum 4096 4096 image size Dedicated Force-distance and Cantilever spring constant calibration I-V spectroscopy with batch processing Script-level control through external program (LabVIEW, C++) 600 1050 300 1950 XEI Image Processing and Analysis Options Ionization System 10 l 11 - Decoupled XY & Z Scanners XEI is the AFM image processing and analysis program. The powerful processing algorithms make the analysis easy and streamlined. With its most advanced and versatile imaging features, XE users can obtain essential and critical information from their experiment. Image analysis of line profile, region, 3D rendering Spectroscopy data analysis module (F-d, I-V) Directly copy/paste to presentation program Automatic Wafer Handler (EFEM or FOUP) Automatic Tip Exchange (ATX) Automatic Tip Exchange performs fully automated tip exchanges in order to seamlessly continue automated measurement routines. It automatically calibrates cantilever location and optimizes measurement settings based on measurements of a reference pattern. Our novel magnetic approach to the tip exchange yields a 99% success rate, higher than the traditional vacuum techniques. The can be further customized by adding an automatic wafer handler (EFEM or FOUP or other). The high-precision, nondestructive wafer handler robot arm fully ensures users to receive fast and reliable wafer measurement automation. The can be equipped with an Ionization system which effectively removes electrostatic charges. It ionizes the charged objects and is very reliable since the system always generates and maintains an ideal balance of positive and negative ions without causing any contamination to the surrounding area. It also reduces the accidental electrostatic built-in charge that may occur during sample handling. Multiple image comparison Image overlay of two different images System Specification 200mm Motorized XY stage: travels up to 275 mm 200 mm, 0.5 μm resolution 300mm Motorized XY stage: travels up to ~375 mm 300 mm 0.5 μm resolution, <1 μm repeatability Motorized Z stage: ~30 mm Z travel distance ~0.08 μm resolution, <1 μm repeatability Motorized Focus Stage: 11 mm Z travel distance for on-axis optics Motorized Angle Range: -19 degree and +19 degree -38 degree and +38 degree <0.5 degree angle repeatability Sample Thickness Allowance: up to 20 mm Full scan range Z run-out: < 2 nm, repeatability <1 nm COGNEX Pattern Recognition: pattern align resolution of 1/4 pixel Scanner Performances XY Scanner Range: 100 μm 100 μm (large mode) 50 μm x 50 μm (medium mode) 10 μm 10 μm (small mode) XY Scanner Resolution: 1.5 nm (high voltage mode) <0.2 nm (low voltage mode) Z Scanner Range: 12 μm (high voltage mode) 1.7 μm (low voltage mode) Z Scanner Resolution: < 0.2 nm Z Scanner Noise Floor: <0.05 nm (w/ Active Vibration Isolation System) AFM and XY Stage Control Electronics Controller Processing Unit: 600 MHz and 4800 MIPS Signal ADC & DAC: 16-bit 500 khz bandwidth, internal lock-in Vibration, Acoustic Noise, and ESD Performances Floor Vibration: < 0.5 μm/s (10 Hz to 200 Hz w/ Active Vibration Isolation System) Acoustic Noise: >20 db attenuation w/ Acoustic Enclosure Dimension & Weight 200mm System: 880(w) 1050(d) 2024(h) w/o EFEM 800 kg approx. (incl. main body) 1820(w) 1050(d) 2024(h) w/ EFEM 1010 kg approx. (incl. main body) Control Cabinet: 800(w) 800(d) 1000(h) 160 kg approx. (incl. controllers) 600(w) x 800(d) x 2000(h) tower type 220 kg approx. (incl. controllers) 1780(w) 980(d) w/o EFEM 3050 (w) 980 (d) w/ EFEM Ceiling Height: 2000 or more Operator Working Space: 3300(w) x 1950(d), minimum (dimension unit: mm) 300mm System: 1220(w) 1200(d) 2024(h) w/o EFEM 1150 kg approx. (incl. main body) 24(w) 1720(d) 2024(h) w/ EFEM 1450 kg approx. (incl. main body) Control Cabinet: 800(w) 800(d) 1000(h) 160 kg approx. (incl. controllers) 600(w) x 800(d) x 2000(h) tower type 220 kg approx. (incl. controllers) Wafer Handler (EFEM): 1270(w) x 1720(d) x 2024(h), 300 kg approx 1220(w) 1200(d) w/o EFEM 24 (w) 1720 (d) w/ EFEM Ceiling Height: 2000 or more Operator Working Space: 4500(w) x 3120(d) (dimension unit: mm) Facility Requirements Room Temperature (Stand By): 10 C ~ 40 C Room Temperature (Operating): 18 C ~ 24 C Humidity: 30% to 60% (not condensing) Floor Vibration Level: VC-E (3 μm/sec) Acoustic Noise: Below 65 db Pneumatics: Vacuum: -80 kpa CDA: 0.7 Mpa Power Supply Rating: 208~240V, single phase, 15A (max) Total Power Consumption: 2 KW (typical) Ground Resistance: Below 100 ohms