Wind Turbine Analysis System - Type 3652 MKII & MKIII

Similar documents
Product Specifications

satech SynchroStar GPS 200 Series

SWT 3000 Teleprotection technical data siemens.com

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

8 to 32 channels Monitoring and Predictive Maintenance System

Shaft Absolute Vibration Monitor Specifications

R&S SMB100N SIGNAL GENERATOR

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Theta 20A / 20V. Technical Data Sheet. Special Features

Application Note. Monitoring strategy Diagnosing gearbox damage

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Accutech AM20. Wireless acoustic monitor field unit

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Trendmaster * Dynamic Scanning Module

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Intelligent Monitoring Analysis System

RADIATED IMMUNITY TEST SYSTEM 6 GHz

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

Lexium integrated drives

Detection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

GFT1504 4/8/10 channel Delay Generator

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Radiated Immunity Test System 6 GHz

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Speed and Key Monitor Specifications

- GOMS II. -GOMS II Gearbox Online Monitoring System. P o w e r T r a n s m i s s i o n. Application Note Wind Energy

Actuator LA12 PRODUCT DATA SHEET

Chapter 6 Specifications

Product Specifications

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

APPLICATION NOTE. Detecting Faulty Rolling Element Bearings. Faulty rolling-element bearings can be detected before breakdown.

V P N. Voltage transducer DVM 2000-B = 2000 V

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

IQgig-IF TM Technical Specifications

P/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant

user leaflet ABSOLUTE TTL MODULE

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

CMC 256plus - protection relay test set and universal calibrator

R&S ZNC Vector Network Analyzer Specifications

Specification for Lightning Sensor

DOBLE F6150e TECHNICAL SPECIFICATIONS

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

3 Phase Power Quality Analy er

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Developer Techniques Sessions

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Integra 1560 and 1580 Digital Transducer Systems

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Vector Network Analyzers ZVB

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Within reach. The standard for online machine surveillance

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

FT702LT HEAVY DUTY WIND SPEED AND WIND DIRECTION IN ONE TOUGH PACKAGE FT702LT. series

PAM & SAM System User s Manual

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVL 1000 = 1000 V

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

DSEM640. DSEControl PROGRAMMABLE CONTROLLER FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

N5194A and N5192A. UXG Agile Vector Adapter 50 MHz to 20 GHz DATA SHEET

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

IQgig-RF TM Model B Technical Specifications

R&S ZVT Vector Network Analyzer Specifications

SINEAX U 553 Transducer for AC Voltage

PQube 3 Specifications

Improve asset protection and utilization

V P N. Voltage transducer DVM 4200 = 4200 V

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

VOLTAGE DETECTING SYSTEMS

Utility Communications Teleprotection Equipment TPT-200

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Impedance 50 (75 connectors via adapters)

VIBRATION ANALYZER. Vibration Analyzer VA-12

CALYS 100. Field precision documenting multifunction calibrator

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Transcription:

Wind Turbine Analysis System - Type 3652 MKII & MKIII The Wind Turbine Analysis System Type 3652 (WTAS 3652) is designed for remotely acquiring scalar vibration data, process parameters and time series vibration data. 16 channel synchronous recording of time series vibration data along with a snapshot of all scalar vibration data and process values can be initiated by an external remote command, or when a combination of measured scalar values falls within certain pre-defined intervals. This Product Specification describes the system components of WTAS 3652. 16 Differential AC/DC Input Channels, 4-20mA or constant current supply for Accelerometers. Channel 15 and 16 can be configured as PT-100 Temperature Inputs Designed for Offshore weather conditions 4 Ethernet connections with switch functionality. Including one optical connection. Service Display for on-site check of network connections and measured values. Continuous measurement of characteristic scalar values Synchronous recording of time waveforms on up to 16 channels Snapshot of all scalar values recorded along with the time waveform. Triggering of time waveform recording by the combined state of a number of measured scalar values. Triggering of time waveform recording by an external command via the WEB interface. Simultaneous storage of high resolution data on all inputs allows for detailed frequency analysis of time waveforms. Advanced trigger facilities allows for recording of time wave forms recorded before; during or after the trigger conditions were fulfilled. Fig. 1: WTAS 3652 MKII shown in its Stainless Steel IP66 enclosure with Data Acquisition Unit Type 2540 (DDAU II), External WEB Server EQ2495/94 and Power Supply EQ2483. WTAS 3652 is specifically designed for cost-effective remote, Wireless or LAN based condition monitoring of a large number of wind turbines. WTAS 3652 makes simultaneous, continuous measurements of a large number of scalar vibration and process values used for reliable fault detection. At the same time WTAS 3652 provides the best possible conditions for advanced vibration diagnosis by recording time waveforms used for detailed time wave form and frequency analysis.

The Mark II and Mark III versions refer to different hardware configurations of the WTAS 3652. In the Mark III version for LAN based systems the external WEB Server has been integrated into the Data Acquisition Unit - DDAUII. The measurement functionality of the two Mark versions is the same. The Mark III version is clearly labeled on the front plate of the DDAUII. WTAS 3652 variant Data Acquisition Unit Interface WTAS 3652 MK II LAN Type 2540 Digital Data Acquisition Unit MK II WEB Server EQ2495 External WTAS 3652 MK II GPRS Type 2540 Digital Data Acquisition Unit MK II WEB Server EQ2494 External WTAS 3652 MKIII LAN Type 2540 Digital Data Acquisition Unit MK III Integrated in DDAUII Internal WTAS 3652 MKIII GPRS Type 2540 Digital Data Acquisition Unit MK III WEB Server EQ2494 External The signal processing unit DDAU II supports efficient fault detection by continuous measurement of a large amount of characteristic scalar values. Some of the characteristic scalar values have been specifically designed to detect certain types of faults such as gear faults by measuring gear mesh vibration using a narrowband measurement where the measurement is locked to the changing speed of the turbine. Other values are more general in nature by covering a larger frequency range in order to give a more general picture of the vibration level of the turbine. The measurement configuration of the DDAU II is called the monitoring template. Different turbines may require different monitoring strategies; therefore different monitoring templates can be uploaded to the DDAUII, thus changing the behavior of the unit. Monitoring templates are composed by a selection of firmware components, such as Sensors, Filters, Detectors etc.. A monitoring template can be illustrated as a signal flow chart showing the different firmware components. Fig. 2: Part of a Monitoring Template showing firmware blocks related to the sensor on 3rd stage of a gearbox The signal flow chart example shows how the 3rd stage of a gearbox is monitored using characteristic scalar values. The sensor component (AC) shows that an accelerometer is used as transducer. The branch marked as (1) shows the firmware components for the filtering provided for the Overall ISO RMS measurement. This measurement is fixed in a standardized frequency range. The branches (3), (4) and (5) are tracking filters measuring the Magnitude and Phase of the 1st, 2nd and 3rd. harmonic of the tooth meshing frequency. As the

tooth meshing frequency varies according to the running speed of the machine, these firmware blocks use the trigger signal from the speed sensor to lock the centre frequency of the filter to the tooth meshing frequency. The filter in branch (2) has also filter limits controlled by the speed of the machine. These two filters are used to calculate an RMS value comprising all three tooth meshing frequencies. By using the Residual Value block (RV) the output from branch (3), (4) and (5) is subtracted from the output from branch (5) to provide an indication of the Vibration level in-between the tooth meshing frequencies, thus detecting less dominant frequency components, e.g. multiple sidebands indicating if serious gearbox damage are present. The filter in branch (6) is designed to catch bearing defect frequencies. The firmware analysis components available in DDAUII are shown in the table below. Sensor Trigger Filter Firmware component for conditioning of a single AC channel. It defines all input channel properties including sensor parameter settings (e.g. sensitivity, OK range, etc.) Firmware component for the continuous conditioning of one incoming trigger signal. It converts the digital time series (time signal) into a series of trigger events by comparing the time signal against a trigger threshold. Firmware components for the continuous filtering of AC- and AC/DCsignals. It consists of a low pass filter and a high pass filter Following versions are used: ISO filter with lower frequency of 10 Hz and an upper frequency of 1000 Hz. HFBP Filter for the monitoring of ranges from 1 khz to 10 khz. Variable Filter for overall value calculation of variable speed machines ECU, Envelope Condition Unit for detection of bearing faults using a high frequency bandpass filter combined with low pass filtering used to detect bearing impacts. Bandpass Filter Rms Detector Phase Detector Residual Value Firmware component for accurate measurement and calculation of the magnitude and phase of a signal. The centre frequency can be lockaed to a trigger signal (i.e. tracking) or can be fixed (i.e. absolute frequency). Firmware component which makes the RMS calculation of the amplitude information of a filter output. Firmware component calculating the phase value of a bandpass filtered signal in the range of 0-360. Firmware component which subtracts narrow band measurements from an overall RMS value. Speed Firmware component for measuring the speed out of a trigger signal. DC Voltage Statistics Firmware component for measuring DC voltage on one channel. It defines all input channel properties including sensor parameter settings (sensitivity, OK range, etc.) Firmware component for processing of DC measurements. Output is the mean, max and min value in a defined time period.

Time Waveforms can be synchronously recorded on all or a specified selection of the 16 input channels as a reaction upon a trigger event. A hardware trigger event software generated trigger event or a command issued by the diagnostic staff at the remote condition monitoring centre. A large buffer used for the time waveform recording makes it possible to offset the trigger event with respect to the requested time record. It is thus possible to capture time wave form data before the trigger event (Time Waveform 1), on either side (Time Waveform 2) or after the trigger event has happened (Time Waveform) Fig 3: Illustration of the Trigger Offset Function in the DDAUII A recording can be triggered in three different ways: - The trigger is a command issued by the diagnostic staff at the remote condition monitoring centre. The trigger is initiated when the state changes on one of the Digital Input Channels connected to an external trigger source. - The trigger is generated by a combination of scalar values measured by the DDAUII. When each of the selected trigger condition values has been within a specified trigger range for a certain time interval and shows a variation less than specified, the trigger condition is valid. Up to three values can be used to define the trigger conditions. Fig 4: Illustration of Range Trigger principle in DDAUII. A specified length of the time waveform is returned. Here shown with two values for generating a trigger event.

The specified trigger range and max. allowed variation ensures that the time wave form has been recorded under stable conditions. Several different trigger conditions can be simultaneously defined in the DDAUII. As each of the trigger conditions are fulfilled, the data are measured and transmitted to the remote server. A snapshot of all measured scalar values is attached to each time waveform for a complete description of the state of the turbine at the time of recording. The time wave forms returned from WTAS 3652 can be analyzed in detail by using the Brüel & Kjær Vibro WTG Analyzer which can be downloaded from the CMS User Homepage. The DDAUII is a powerful data processing unit used for the continuous measurements of the scalar values and for the time wave form recording. The physical unit consists of the following main elements: The DDAUII is equipped with a service display to support the activities during installation and maintenance. The service display shows the IP Addresses, levels of Analog and Digital inputs, values received from the turbine controller etc.. Each of the 16 differential AC/DC input channels can be configured as one of the following: Accelerometer Input: An input with constant current supply for direct accelerometer input. (ICP) 4-20mA Input: To receive analog signals directly from other units Trigger Input:: For speed measurements and tracking PT-100 Input: In addition to the 3 input configurations valid for all channels, Channel 15 and 16 can be configured as PT-100 inputs to be used in connection with temperature sensors. Fig. 5: The DDAUII Service Display The DDAUII has a built in network switch with four ports. Three RJ-45 connectors and one optical fiber input. The RJ45 ports have auto detect functionality, facilitating the use of crossed as well as non-crossed cables. The switch functionality makes it very easy to connect the DDAUII to other equipment or to daisy chain several DDAUII units. The WEB server is an interfacing and post processing unit for the DDAUII with several tasks. The WEB Server receives an average of all the characteristic scalar values from the DDAUII every two minutes and stores each value in a number of long term averaging buffers, one for each power class of each measurement defined for the turbine. At preset intervals a set of all the averaged values are transferred via the internet to the central Data Acquisition Server at the Remote Monitoring Centre. If connection to the Data Acquisition Server is lost, the averaging in each buffer goes on. During the averaging, emphasis is made on the most recent data, no matter how long time the turbine has been disconnected. When the connection is re-established, a dataset with the average of the most recent vibration history of the turbine is sent to the central Data Acquisition Server immediately. For the DDUAII Mark III the WEB Server is integrated in the DDAUII. For the DDAUII MKII the WEB Server is an external unit. This Power Supply delivers all the necessary power for the DDAU II and the WEB Server. Refer to the technical specifications listed below.

Technical Specifications Digital Data Acquisition Unit Type 2540 (DDAUII) 16 differential AC, DC and Trigger inputs. Input impedance:...50k Common Mode Rejection:...>40dB Input voltage range: Positive:... -1.5 to +25.5VDC Negative:... +1.5 to -25.5 VDC Accuracy: AC amplitude:...±0.5db DC amplitude :...1% ±40mV offset Other Dynamic range:...90db Resolution:... 24bit Sampling frequency:...25.6khz ±0.1% Transducer power:... 5mA at 26VDC Bandpass filter: Frequency range (absolute):... 0.1Hz to 10kHz Filter slope:... 18dB/oct. Butterworth Narrow-band filter: Frequency range (absolute):... 0.1Hz to 10kHz Bandwidth...1 to 50% 4 galvanically isolated digital inputs. Input impedance:...2.7k Nominal signal voltage: Low range:... -33V to +2V High range:... +18 to +35V Maximum voltage:... +-50V 2 relays with dry contacts, type SPDT. Nominal working voltage:...24v Maximum current:...100ma 4 Ethernet Connections with switch functionality 3 RJ45 connectors: With auto detect facility for detection of crossed/non crossed cables 1 optical port (SFPT) The SFPT (Small Form Factor Transceiver) accepts among several, a Duplex LC optical interface for multimode fibers. RS-232: Baud rate:...up to 115kBaud RS-485: Baud rate:...up to 115kBaud Power supply: Voltage:... 22 to 26V Power consumption:... 20VA Transducer power supply range: 26V±10%, 100mA Physical size: Height:...45mm Width:...280mm Depth:...250mm Damp heat, Dry heat and Salt mist test has been carried out with the unit mounted in the IP66 enclosure. (Picture on front page). Other specifications are valid for the unit itself. Vibration - IEC 60068-2-6 Resonance search Frequency/Amplitude:... 10-150Hz 1.0g Sweep rate:... 1 octave/minute Number of axes:... 3-mutually perpendicular Vibration - IEC 60068-2-64 Random Frequency/Amplitude:... 10-150Hz Acceleration:...10-20Hz 0.01g/Hz Spectral Density:... 20-150Hz 3db/oct Total RMS:...0.7g RMS Duration:... 90 min per axis Number of Axes:...3, mutually perpendicular Damp Heat - IEC 60068-2-30 Cyclic Upper temperature:... +55 Number of cycles:...6 Acceleration:...10-20Hz 0.01g/Hz Dry heat - IEC 60068-2-2 Temperature:...+60C Duration:...16 hours Cold - IEC 60068-2-1 Temperature:... -40 C Duration:...16 hours Salt mist- IEC60068-2-52 Severity 2:...NaCl concentration: 5% ph of salt solution:... 6.5-7.2 Number of cycles:...3 Duration... 3 days EMC EN 61000-6-4, 2007 Generic Emissions standard. Part 2: Industrial Environment EN 61000-6-2, 2005 Generic Immunity standard. Part 2: Industrial Environment