S S S2 Operation Manual

Similar documents
M5 Diagnostic Ultrasound System

DC-6 Expert. Diagnostic Ultrasound System

M7Vet Diagnostic Ultrasound System. Operation Note

Quick Reference Guide

DC-6. Diagnostic Ultrasound System

Diagnostic Ultrasound System. Operation Note

KIZLON. Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Website:

4 Working With Scan Modes

Vevo770 Ultrasound. Quick Operation Guide

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E

Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.

ACUSON X150 Knobology & User Guide

QUICK GUIDE

Ultrasound Diagnostic Scanner INSTRUCTION MANUAL

SONOGRAPHIC PHYSICS, INSTRUMENTATION & DOPPLER REVIEW Part 3

Chapter 1: Introduction

Vivid i Ultra-Portable Echo System

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

Printed in Japan E318

Excellent Performance; Ease of Use

Multipurpose Color Ultrasound System IMAGING SYSTEMS

User Manual Veterinary

Product Description. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing. Display Screen

Digital Portable Overhead Document Camera LV-1010

Quality Ultrasound Systems

Vivid 7 Pro Breakthrough 2008 Release

5. User-Centered Design Focus - High mobility cart - 19" formate high resolution Flat panel LCD display monitor or more - User adjustable control pane

Q5 VET. Compact, Affordable Color Doppler for VET

Discover the new Prestige and experience 3D/4D imaging beyond your imagination.

SEM OPERATION IN LOW VACUUM MODE

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

UGEO H60. Performance in Style. Features

μscope Microscopy Software

SONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications.

DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System

HD-01e High Definition Easy Scope

Mighty Scope 5M. Instruction Manual. aveninc.com

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Index. Page (s) 1 4. Features

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Introduction. Introduction

MEDIA CONVERSION PROJECT: DIGITIZING HISTORIC PHOTOS

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

Sante FFT Imaging Copyright 2018 Santesoft, all rights reserved

EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality.

Quintic Software Tutorial 7c

Ultrasound System Specifications

Silhouette Cameo Cheat Sheet

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Design Your Performance

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Model: ESE-6 Portable Color Ultrasound System

Ultrasound System Specifications

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

MEASUREMENT CAMERA USER GUIDE

DOCUMENT SCANNER INSTRUCTIONS. Space. Backup. Count Only. New File. Scanner. Feeding Option Manual Auto Semi-Auto

KEE HING CHEUNG KEE CO., LTD. DLFTZ CHANG HING KEE INT L INDUSTRY & TRADE CO., LTD.

Digital Microscope. User Manual

Ultrasound System Specifications

VisualSonics Application Protocol Subharmonic Imaging using MicroMarker Non-Targeted Contrast Agents in the Kidney

Accutome Connect Visual Aid

Tribometrics. Version 2.11

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

Scanning or Printing a Map

Model: ESE-G50 Color Ultrasound System

Introduction. Introduction


KODAK Dental Imaging Software. Quick Start Guide

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Endoscopic Ultrasonography System

PC System Requirement For Dual Microscope

Product Description. Display Screen. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing

ENDOSCOPIC ULTRASOUND SYSTEMS

A COMPACT SYSTEM WITH ADVANCED PERFORMANCE

Tinker Tuesday Project - Drinking Glasses

Table of Contents 1. Image processing Measurements System Tools...10

LOGIQ e Ultrasound. GE Healthcare. Product Description

FE-SEM SU-8020 Operating manual (Preliminary version)

Pulse Doppler Flow-Dop

This manual describes the Motion Sensor hardware and the locally written software that interfaces to it.

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

M 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it.

Wound Healing Analysis in the Automated Cellular Analysis System

USER MANUAL. ScanFlex AUTOMATED SCANNING DEVICE SCANFLEX Rev 5.0

INTRODUCTION TO DATA STUDIO

Fluke 125. Getting Started. Industrial ScopeMeter

Introduction to Ultrasound Physics

Lettering Fabric Preparation deco 340 aurora 430E & 440QEE NAME artista 630E, 635LE & 640E

Imaging Features Available in HTML5. it just makes sense

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Introducing Photo Story 3

instead we hook it up to a potential difference of 60 V? instead we hook it up to a potential difference of 240 V?

How to use Photo Story 3

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

in the list below are available in the Pro version of Scan2CAD

EENG-201 Experiment # 4: Function Generator, Oscilloscope

My Blogs: To Add New Blog Post: o Click on the My Learn360 link. You will then see eight different tabs (below).

Medical Imaging (EL582/BE620/GA4426)

Experiment P01: Understanding Motion I Distance and Time (Motion Sensor)

Copyright Notice. Trademarks

Transcription:

PREPARATION 1. How to create and input patient data? In the MAIN INTERFACE, press the key, to enter into the patient exam list interface. Then, click New patient item to create new patient files. Patient data can be entered with PC keyboard, while each patient can get an ID number automatically. 2. How to enter the exam mode? In the MAIN INTERFACE, choose transducer first, then choose and press EXAM icon to enter the exam mode. B MODE SCANNING 3. How to adjust the 2D basic parameters? GAIN: To increase and decrease the signal of grayscale. TGC: To compensate the gain in vertical levels. FOCUS: Move the FOCUS to the region of your target. DEPTH: Position your target at the middle of the whole screen. 4. How to optimize the 2D image? In the EXAM INTERFACE, press (MENU) key, move cursor with (Angle) and adjust parameters with (MENU) knob. - Dynamic Range (20-320dB): Lower DYN for better contrast resolution, while higher DYN for better detailed information. - Frequency (2-15MHz): Lower FRE for better penetration in the far field, while higher FRE for better resolution in the near field. - Image processing (0-2): Reduce the speckle noise inside the imaging area

5. How to change the image orientation? LT/RT: In all image modes (real-time or frozen), use orientation. key to change the image left/right Up/Down: Press key to alternate the image orientation between up and down. 6. How to get the 2B and 4B mode? 2B: In the B mode, press button to enter into 2B mode, and use key to switch the active image. 4B: In the B mode, press number on the PC keyboard to enter into 4B mode, and still use key to switch the active image. 7. How to make panoramic imaging? Press K key on PC keyboard, then start moving the probe to get a panoramic image and then press freeze. 8. How to make the basic measurement in 2D mode? Measurements can be done not only after freezing but also under real-time. - Distance: a. Press button next to trackball b. Press button to enter into the Calculation List, choose DISTANCE under BASIC MEASUREMENT - Area: a. Press button next to trackball. b. Press button, choose AREA under BASIC MEASUREMENT - Ellipse: a. Press button next to trackball. b. Press button, choose ELLISPE under BASIC MEASUREMENT

- Volume: Press button, choose Volume (Height x Width x Length). - Angle: Press button, choose Angle. 9. How to get IMT and specialized measurement Press button to enter into the Calculation List, choose IMT under VASCULAR measurement. Other specialized measurement can also be found under this list. Note: a. Both basic and specialized measurements can be done not only after image frozen but also under real-time. b. The calculation list is fully opened which offers measurements in different mode; for example, you can get access to OB measurement even when you re in the vascular mode with linear probe. c. Trackball and key are used for choosing different calculation list or measurements. M MODE SCANNING 10. How to change the B/M format? In the 2D scanning, press to enter B/M mode. Press (MENU), use (Audio) knob to choose items in the menu list. Change the B/M display format with menu knob including five options. V1/1, V1/2, H2/1, H1/1, H1/2. 11. How to make the M measurement? Time: press to enter the basic measurement, place trackball on the M graph, and then move to the measurement list and click time. Acceleration: press then move to the measurement list and click Slope. to enter the basic measurement, place trackball on the M graph, and HR: press to enter the basic measurement, place trackball on the M graph, and then move to the measurement list and click HR. Items under Basic measurement Time, Distance, Slope, T1/T2, D1/D2

12. How to make the specialized measurement in M mode? Press, when place trackball on the 2D image, calculation list will show measurements for 2D image. Place trackball on the M graph, move trackball to measurement list, choose cardiac measurement. Items under Cardiac measurement include: +LV, Mitral Valve, Aortic Valve. COLOR DOPPLER SCANNING 13. How to get the Doppler Power Image (DPI) and Color Flow Mode (CFM)? DPI: In the 2D EXAM mode, press to enter into the Power Doppler CFM: In the 2D EXAM mode, press to enter into the Color Mode 14. How to optimize the color Doppler image? -- Knob on keyboard D Gain: To increase and decrease the color Doppler signal. PRF: To adjust the speed scale for the color Doppler. Steer: To adjust the steer angle of ROI -- Parameters in menu Press (menu) to enter parameters list, use (Audio) knob to select items in the list, rotate (menu) knob to adjust WF for noise elimination - Wall Filter (30-465): To eliminate the low frequency noise generated by movements of blood vessel walls. 15. How to get the PW mode? PW: In the 2D EXAM mode, press to enter into the Color Mode firstly, and then press PW to enter into the PW-duplex mode, press to activate PW spectral display. 16. How to adjust PW image? D Gain: To adjust brightness of spectral display.

Baseline: To adjust the 0cm/s baseline for better color and spectral display. PRF: To adjust the speed scale for the color Doppler and spectral Doppler. Correctional Angle: Adjust this button to optimize the spectral Doppler signal. PWR DYN (20-200dB): Lower DYN for better contrast resolution, while higher DYN for better detailed information. Frequency: Lower FRE for better penetration in the far field, while higher FRE for better resolution in the near field. 17. How to do the auto trace? After pressing the button to activate the spectral Doppler, press to achieve automatic envelope with or without freezing the image. 18. How to make the basic measurement in PW mode? Place trackball on the PW graph, press to enter the basic measurement. Basic Measurements including: velocity, time, HR, manual trace 19. How to make the special measurement in PW mode When place trackball on the 2D image, calculation list will show measurements for 2D image. Press, place trackball on the PW graph, move trackball to measurement list, choose cardiac measurement. Cardiac measurement TEI, PHT, Mitral Valve, Tricuspid Valve, Pulmonary Valve, Aortic Valve. SAVE AND REPORT 20. How to save images and cine? After freezing the image, press to save the image, press for a while to save the Cine. 21. How to make the measurement on the achieved image? Press to enter Patient Exam List, find and open the achieved image by double click. Press to make measurements. Use or to delete the last or all measurements.

22. How to print image? a. After freezing the image in the exam interface, press for automatic print of image. b. In Patient Exam List, select saved image and click print item. 23. How to create report? After the examination, you can press to enter into the REPORT INTERFACE. On the one hand, all measurement results are in the report which divided into different applications such as Cardiology, Obstetrics and so on. On the other hand, users can insert images, description, graphs and comments into the report. 24. How to add images and comments to report? In the Measurement Report Interface, click image view to add image and Edit to add comments. 25. How to copy images and cine to USB? Plug in USB disk. Press to enter Patient Exam List, Open the patient file. Select the images/cine, choose the wanted PC formats (JPG, BMP and TIF for still Image, WMV and AVI for cine) and click Export. 26. How to copy the patient file or directory to USB or DVD? Plug in USB or connect DVD, Press to enter Patient Exam List, click Export Screen, select the patient files, choose the formats wanted(system/pc/dicomdir), then click Patient Export. Tips: this can only be done while all the exams are closed, or users have to close the exams first. 27. How to print report? In the Measurement Report Interface, click.

Pre-Set Setting A. After freezing image, enter measurement/body marker/annotation menu automatically. In MAIN INTERFACE, press menu general general Auto Freeze Response. Cine Measure Bodymark Comment Arrow B. Front Size In MAIN INTERFACE, press menu general general font size. Comment 12-24 Measure Report 16-19 Image Parameter 12-16 Title Bar 12-15 C. Storage time/length In MAIN INTERFACE, press menu general storage Store Frame 1-999 D. Store region In MAIN INTERFACE, press menu general storage storage region Full Screen US Image Right Top E. Display items for report In MAIN INTERFACE, press menu report display items for Report Patient Information Exam Information Measurements Image Graphs Comment