ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Similar documents
ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

OPERATION MANUAL LDM-1000

Operation Manual. LVDT/RVDT Signal Conditioner

OPERATION MANUAL ATA-2001 LVDT/RVDT Signal Conditioner

Model 140 Inline Amplifier

E2-Series Inclinometer

AccuStar Electronic Clinometer

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PSI Temperature Scanners

XPC10 High temperature miniature pressure sensor

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HTM25X0LF Temperature and Relative Humidity Module

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

Signal Conditioning Amplifier

Signal Conditioning Amplifier

Signal Conditioning for MEAS Pressure Sensors

Accelerometer ACH-01. Piezoelectric Accelerometer Wide Bandwidth; AC Coupled Ultra Low Power High G Ranges

P125 High pressure sensor

XP5 Miniature pressure sensor

NDT1-220K Ultrasonic Transducer

Freescale Semiconductor Data Sheet: Technical Data

MiniSense 100 Analog PCB

LAUREL ELECTRONICS, INC.

80 khz Cylindrical Ultrasound Transducer

Signal Conditioning Amplifier

DRG-SC Series Signal Conditioners

FC22 Compression Load Cell

ELPF Load Cell DESCRIPTION

P-Series Inclinometer

Altitude and Airspeed Measurements Temperature Range. Range psid psig psia 0 to 1 0 to 5 0 to 15 0 to 30 0 to 50 0 to to to 300

TSYS02S Digital Temperature Sensor

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

A Simple Pressure Sensor Signal Conditioning Circuit

HM1500LF Relative Humidity Module

CTE7000 Series Miniature pressure transmitters

Non-Submersible Industrial Pressure Transducer

FC Series Signal Conditioners

TSYS02P Digital Temperature Sensor

ED-17 Serial Output Magnetic Encoder

MODEL AT-10 ANALOG TRANSMITTER

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

TSYS02D Digital Temperature Sensor

Lock-In Amplifiers SR510 and SR530 Analog lock-in amplifiers

ISOLATED 4-20 ma TRANSMITTERS

CTE8000 Series OEM pressure transmitters for industrial media

The Harvard Research Carrier Signal Conditioner User s Manual

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

Installation and Operating Manual

Linear measurement with a magnetic pole stripe (I 2 C-Mode)

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters

Model 3102D 0-2 kv H.V. Power Supply

GENERAL OPERATING INFORMATION

Freescale Semiconductor, I

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

High-stability Isolated Error Amplifier. ADuM3190. Preliminary Technical Data FEATURES GENERAL DESCRIPTION APPLICATIONS FUNCTIONAL BLOCK DIAGRAM

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

High Power Piezo Driver

U5700 Submersible Liquid Level Pressure Transducer

DP2000 ORDERING GUIDE To Order MODEL NO.

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

TSYS01 Digital Temperature Sensor

NCP A Low Dropout Linear Regulator

ISOlinear Architecture. Silicon Labs CMOS Isolator. Figure 1. ISOlinear Design Architecture. Table 1. Circuit Performance mv 0.

TECHNICAL DATASHEET #TDAX032100

FC22 Compression Load Cell

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

MARKING DIAGRAMS Split Supplies Single Supply PIN CONNECTIONS MAXIMUM RATINGS ORDERING INFORMATION SO 14 D SUFFIX CASE 751A

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Isolated, Unregulated DC/DC CONVERTERS

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

PIEZO FILM LAB AMPLIFIER

2014 Short Form Test and Measurement Catalog

Portable Multi-Channel Recorder Model DAS240-BAT

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

Economical Digital Indicators For Process and Electrical Measurement

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

DEMONSTRATION NOTE. Figure 1. CS51411/3 Demonstration Board. 1 Publication Order Number: CS51411DEMO/D

HS1101LF Relative Humidity Sensor

ACT111A. 4.8V to 30V Input, 1.5A LED Driver with Dimming Control GENERAL DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION CIRCUIT

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

MPXM2051G, 0 to 50 kpa, Gauge Compensated Pressure Sensors

Regulating Pulse Width Modulators

LVDT selection, handling and installation guidelines

HTG3500 Series Relative Humidity and Temperature Module

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

PD7500 Pulse-Width-Modulation Control Circuits

P-Series Inclinometer

ARCHIVE INFORMATION LOW POWER NARROWBAND FM IF

SWR300 Precision Sine \ Cosine Reference

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

LVC Low Voltage Conditioner. User Manual

PD494 Pulse-Width-Modulation Control Circuits

Miniature pressure sensor

Transcription:

115 or 220 VAC operation Microprocessor controlled calibration Superior digital filtering Selectable excitation frequencies & amplitudes Voltage and current outputs 250 to 1000Hz selectable frequency response Auto fall-back synchronization Splash-proof front panel with status LEDs 1/8 DIN standard panel mounting DESCRIPTION The ATA-2001 is a general purpose, AC line-powered, LVDT/RVDT analog conditioner with digital setup and calibration. The embedded microprocessor generates a PWM-shaped sine wave and handles all calibration functions. It also controls the demodulation, filtration and synchronization of the LVDT or RVDT transducer signal. All settings are stored in non-volatile memory for restoration on power up. Zero, Gain and Phase adjustments are accomplished via the use of splash-proof front panel pushbuttons and digital voltage dividers. Intended for the most demanding industrial applications, the ATA 2001 is CE certified, and has been rigorously tested to the highest industrial standards for EMI, RFI and ESD. Designed for universal compatibility with 4, 5 and 6 electrical connection transducers, the ATA-2001 provides a wide range of oscillator frequencies, gains and two excitation voltages, affording maximum interface versatility. The very high drive current of 45mA allows operation with transducer input impedances as low as 12 Ohms (with 0.5VRMS excitation). With high gain capability and low noise, the ATA 2001 provides measurement resolutions beyond any product currently available. The unique auto fall-back synchronization feature allows reliable master/slave operation, for prevention of amplifier cross talk, without the worry of sync signal loss. If the internal processor in a slave amplifier detects an unstable or missing sync signal, the internal clock will take over, continuing at the pre-selected nominal frequency. Upon restoration of a normal sync pulse, the oscillator will return to the slave mode. The ATA 2001 is contained within a rugged, one-piece, extruded aluminum housing which provides optimal amplifier performance under the most rigorous EMI and RFI conditions. An integral panel mounting system provides for convenient 1/8 DIN standard, panel installation. A pre-punched 19 rack adapter is also available to accommodate up to eight amplifiers per adapter installation. Also see our other signal conditioner models, LDM-1000 (DIN rail mount, VDC and 4-20mA output), LVM-110 (VDC input/output), LiM-420 (4-20mA transmitter), PML1000 (1/8th DIN panel meter, VDC, current and RS485 outputs), and our IEM-422 (NEMA-13 rated 4-20mA transmitter). Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners. Data sheets can be downloaded from our web site at: http://www.meas-spec.com/datasheets.aspx MEAS acquired Schaevitz Sensors and the Schaevitz trademark in 2000. FEATURES APPLICATIONS Microprocessor controlled & non-volatile memory Power-gen turbine control Phase shift compensation Head box slice lip position control Auto fall-back synchronization Roller gap position feedback Rugged extruded aluminum housing Precision metrology labs 1/5

PERFORMANCE SPECIFICATIONS Line power requirements Line voltage regulation Unipolar voltage output range Bipolar voltage output range Noise and ripple (voltage output) Output impedance (voltage output) Current output range Maximum loop resistance Noise and ripple (current output) Frequency response @ -3db ELECTRICAL SPECIFICATIONS 115VAC ±10%, 50-400Hz; 220VAC ±10%, 50-400Hz (switch selectable) ±10%, with no change in output Voltage output 0 to 10VDC, with 10mA maximum current capability ±10VDC (using 100% zero suppression), with 10mA maximum current capability 3mVRMS maximum @ 2.5KHz excitation frequency 1Ω maximum Current output 4 to 20mA 700Ω with internal loop supply; 1000Ω with 24VDC external supply (32vdc MAX) 10µA rms (max) Analog outputs frequency response 250Hz @ 2.5kHz excitation 500Hz @ 5.0kHz excitation 1000Hz @ 10kHz excitation Amplifier characteristics Transducer input sensitivity range High gain: 0.04 to 0.9VRMS; Low gain: 0.5 to 10VRMS (switch selectable) Input impedance 100kΩ Zero suppression range ±110% of FSO Phase shift compensation range ±120 degrees maximum Non-linearity and hysteresis ±0.05% of FSO, maximum Stability ±0.05% of FSO, maximum, after 20 minute warm up Temp coefficient of output ±0.02% of FSO per degree F [±0.036% per degree C] Voltage Current Frequency Transducer type Input impedance Full scale output Transducer excitation 0.5 or 3.5VRMS, sine wave (switch selectable) 45mA RMS maximum 2.5, 5 or 10kHz (switch selectable) Transducer requirements LVDT or RVDT with 4, 5 or 6 electrical connections 12Ω minimum with 0.5VRMS excitation; 80Ω minimum with 3.5VRMS excitation High gain: 0.04 to 0.9VRMS; Low gain: 0.5 to 10VRMS ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS Operating temperature range Storage temperature range Weight Transducer electrical connections Output and sync connections Mounting -40 F to +185 F [-40 C to 85 C] -40 F to +257 F [-40 C to 125 C] 2.1lbs [950 grams] DB-9S (See our transducer data sheets for jumper cables or connector option) Barrier terminal strip 1/8 DIN standard panel mounting (19 rack adapter for 8-up available) Notes: All values are nominal unless otherwise noted FSO (Full Scale Output) is the largest absolute value of the outputs measured at the range ends 2/5

WIRING INPUT (TRANSDUCER) WIRING OUTPUT 3/5

DIMENSIONS DIMENSIONS - RACK ADAPTOR (SOLD SEPARATELY) Accommodates up to eight ATA-2001 Amplifiers Dimensions are in inches (mm) 4/5

ORDERING INFORMATION Description Part Number ATA-2001 LVDT/RVDT Signal Conditioner 02291327-000 Rack Adaptor for up to 8 signal conditioners 05290032-000 (ATA-2001 conditioners not included) Operation manual: http://www.meas-spec.com/downloads/ata_2001_operation_manual.pdf TECHNICAL CONTACT INFORMATION CANADA Durham Instruments 900 McKay Road, Unit 3 Pickering, ON L1W 3X8 Tel: 905-839-9960 Fax: 905-839-4325 Email: sales@disensors.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 5/5