CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

Similar documents
CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

IEC Electrical fast transient / Burst immunity test

Voltage dips short interruptions with PFS and Netwave

ISO/TS ELECTRICAL DISTURBANCES BY CONDUCTION AND COUPLING PART 4: ELECTRICAL TRANSIENT CONDUCTION ALONG SHIELDED HIGH VOLTAGE SUPPLY LINES ONLY

Low Frequency Measuring System

Voltage Transient Emission Test

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

Technical Specification

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Fluke Norma 4000/5000

MONITORING DEVICE 4 khz to 400 MHz

Schlöder GmbH - EMC Test and Measurement Systems Model #

TesT system for ConduCTed and radiated immunity

AC Power Sources. Newtons4th Ltd

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Fluke Norma 4000/5000

METRAClip87 and 88 Clamp Multimeters

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

METRAClip85 and 86 Clamp Multimeters

FINAL DRAFT TECHNICAL REPORT CLC/FprTR RAPPORT TECHNIQUE TECHNISCHER BERICHT January English version

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

Programmable AC Power Source Model 9801

Combination Wave Test System

Vector Network Analyzers ZVB

AC/DC Converter LD20-26Bxx Series

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

True RMS Bench Multimeter 5492B

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

SPECIFICATION. LED Driver. Model : SI-EPF006650WW CUSTOMER : SAMSUNG CHECKED APPROVED DRAWN SAMSUNG #2, NONGSEO-DONG, GIHEUNG-GU,

Applications. Other applications include:

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

VariTrans P D1 TRMS

Insulation Test System

Keysight Technologies AC6800B Series Basic AC Power Sources. Data Sheet

PTE-50-CET. Three phase relay test set Current/Voltage

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

CMC 256plus - protection relay test set and universal calibrator

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

Function/Arbitrary Waveform Generator

MGA Magnetic field system. DC khz

Advanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide

Because you can t afford downtime

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES

Power Quality and Energy Measurement PEM735

Conducted Immunity Testing

AC/DC Power Sources ACS Series

Power Quality and Energy Measurement PEM575

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

AC/DC Power Sources ACS Series

Insulation Test System

DOBLE F6150e TECHNICAL SPECIFICATIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

Transcription:

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC 61000-4-16, IEC 61000-4-19 ANNEX C, 0HZ (DC) TO 165KHZ FOR TESTS ACCORDING TO... > EN 61000-4-16 > IEC 60255-22-7 > IEC 60255-26 > IEC 60533 > IEC 61000-4-16 > IEC 61000-4-19, Annex C > IEC 61326 > IEC 61543 > IEC 61850-3 > prtr 50579 CWS 500N4 - TESTING FOR IMMUNITY TO CONDUCTED, COMMON-MODE DISTURBANCES The CWS 500N4 is the state-of-the-art solution in a compact single-box design to test for immunity to conducted, common mode disturbances in the frequency range 0Hz (DC) to 165kHz. Such test requirements are specified in IEC 61000-4-16 and cover continuous mode testing as well as short term testing with DC, 16 2/3Hz, 50Hz and 60Hz with 4 test levels each plus a sweep mode from 10Hz to 165kHz. Additionally, the CWS 500N4 can be used for testing electricity metering equipment as per prtr 50579 and Draft standard IEC 61000-4-19, Annex C. HIGHLIGHTS > Most compact equipment for common-mode disturbances as per IEC 61000-4-16 > Built-in LF signal generator and LF amplifier > Sweep mode capability 10Hz to 165kHz > Built-in rectifier module for DC testing > Option for Electricity Meter testing acc IEC 61000-4-19 Annex C APPLICATION AREAS INDUSTRY RESIDENTIAL www.emtest.com EM TEST > PAGE 1/5

TESTING AS PER IEC/EN 61000-4-16 TESTING AS PER IEC/EN 61000-4-16 OUTPUT CHARACTERISTICS CONTINUOUS MODE DC, 16 2/3Hz, 50Hz and 60Hz 0.1-35 Vrms or DC 1V continuous 3V continuous 10V continuous 30V continuous Ripple on DC < 5% < 10% (sinusoidal waveform) OUTPUT CHARACTERISTICS SHORT-TERM MODE DC, 16 2/3Hz, 50Hz and 60Hz 1-330Vrms or DC 10V for 1s duration 30V for 1s duration 100V for 1s duration 300V for 1s duration Phase synchronisation < 10% (sinusoidal waveform) 0 ± 5% Ripple on DC < 5% Fall/rise time Note: between 1us and 5us These tests require either the optional MV 2606N2.2 motor variac or the optional programmable AC voltage source ACS 500N2.3. OUTPUT CHARACTERISTICS 15HZ - 165KHZ Frequency range 10Hz to 165kHz 0.1 to 35Vrms 1V - 0.1V - 1V 3V - 0.3V - 3V 10V - 1V - 10V 30V - 3V - 30V MEASUREMENT Voltage TEST ROUTINES Quick Start Service < 1% (sinusoidal waveform) internal rms measurement Immediate start; easy to use and fast discrete frequency testing Service, Set-up TESTING OF ELECTRICITY METERING EQUIPMENT AS PER TR-EN 50579 INTERFERENCES DISTURBANCES TESTING AS PER TR-EN 50579 AND IEC 61000-4-19 ANNEX C (OPTION) Total harmonic (THD) 2kHz to 150kHz Max. 3A up to 150kHz <5% at maximum level Accuracy better than ± 5% Frequency step Max. 1% Output impedance 1.0ohm (external decoupling impedance SH 1R) www.emtest.com EM TEST > PAGE 2/5

GENERAL DATA INTERFACE Serial interface USB Parallel interface IEEE 488, addresses 1-30 Fail 1 Fail 2 SOFTWARE icd.control GENERAL DATA Dimensions Weight Supply voltage Input power Fuses Cooling BNC input; test will be stopped immediately (when input becomes active low) BNC input; test will be stopped (when input becomes active low) and contiunued (input active high). After 10 fail events the test will be stopped. Extensive and most versatile remote control and reporting software. A standard library helps to configure the test setup. Part of delivery 19"/6HU, 555mm x 448mm x 286mm Approx. 30kg 115V - 230V +10/-15%, 50/60Hz Max. 600W Temperature 10 C - 40 C 2x6.3AT (115V) or 2x3.15AT (230V) 2x10AT for AC-source Active cooling, air ventilation ACCESSORIES COUPLING NETWORK CN 16-L2/L4 CN 16-L2.1 CN 16-L3 CN 16-L4/690V CN 16-L8 CDN 16-L2 CDN 16-L4/400 V 2-wire/4-wire coupling network, switchable, EUT Umax. AC: 440V 16.7Hz..80Hz, 2-wire coupling network, EUT Umax. AC: 300V 16.7Hz..80Hz, EUT Umax. DC: 220V, Power dissipation: max. 200W, active cooling,overtemperature protection, Mains: 85-265 V 50/60Hz, Fuse 1AT 3-wire coupling network, EUT Umax. AC: 440V 16.7Hz..80Hz, 4-wire coupling network, EUT Umax. AC: 3x690V 50/60Hz, 8-wire coupling network, EUT Umax. AC: 300 V 16.7Hz..80Hz, GEN IN Umax.: 330 V AC/DC, EUT Umax. DC: 160V, 2-wire coupling network, decoupling with isolation transformer, EUT Umax./ Imax.: 300V 16A GEN IN Umax.: 330VAC 4-wire coupling network, decoupling with isolation transformer EUT Umax./ Imax.: 3x480V 16A, GEN IN Umax.: 330VAC CDN 16-T2 Telecom T-network, 60VDC, 2A, EUT Umax.: 60VDC, EUT Frequency range: Telecom applications, www.emtest.com EM TEST > PAGE 3/5

ACCESSORIES COUPLING NETWORK CN 60255-22-7 4-wire coupling network for common mode and differential mode coupling as per: IEC 60255-26, figs. A1, A2 and A3, previous IEC 60255-22-7, figs. 2, 3 and 4 CN 61543 Coupling network as per IEC 61543 (100ohm) AC SOURCES ACS 500N2.3 MV 2606N2.2 AC power source 0-330VAC/2kVA, 10Hz - 80Hz, galvanically isolated; controlled by CWS 500N4 via serial interface Mains supply: 230V/16A, 50/60Hz Motor variac 0-330VAC/2kVA, 50Hz/60Hz, galvanically isolated; controlled by CWS 500N4 via 0-10V analog output Mains supply: 230V/9A, 50/60Hz EXTENSION FOR APPLICATION AS PER IEC 61000-4-19 ELM set ELM-R set (upgrade) Electricity meter test set as per IEC 61000-4-19 Annex C included: -SH ELM, 1R and 100R, Shunt resistor box and decoupling impedance, -Current meter ext., 5 1/2 digit, 150kHz, USB remote control with icd.control software, -USB remote cable -Cable set SH ELM to current meter Electricity meter test set as per IEC 61000-4-19 Annex C included: -CWS500N4 hardware upgrade and calibration, -SH ELM, 1R and 100R, Shunt resistor box and decoupling impedance, -Current meter ext., 5 1/2 digit, 150kHz, USB remote control with icd.control software, -USB remote cable -Cable set SH ELM to current meter -Call representative for details www.emtest.com EM TEST > PAGE 4/5

COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland AMETEK CTS GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61 204 41 11 > Fax +41 (0)61 204 41 00 Internet: www.ametek-cts.com > E-mail: sales.conducted.cts@ametek.com Germany AMETEK CTS Europe GmbH > Customer Care Center EMEA > Lünener Straße 211 > 59174 Kamen > Germany Phone +49 (0) 2307 26070-0 > Fax +49 (0) 2307 17050 Internet: www.ametek-cts.com > E-mail: info.cts.de@ametek.com Poland AMETEK CTS Europe GmbH > Biuro w Polsce > ul. Twarda 44 > 00-831 Warsaw > Poland Phone +48 (0) 518 643 12 Internet: www.ametek-cts.com > E-mail: Infopolska.cts@ametek.com USA / Canada AMETEK CTS US > 52 Mayfield Ave > Edison > NJ 08837 > USA Phone +1 732 417 0501 Internet: www.ametek-cts.com > E-mail: usasales.cts@ametek.com P.R. China E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Phone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: www.emtest.com > E-mail: info@emtest.com.cn Republic of Korea EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Phone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Singapore AMETEK Singapore Pte. Ltd > No. 43 Changi South Avenue 2 > 04-01 Singapore 48164 Internet: www.ametek-cts.com > E-mail: singaporesales.cts@ametek.com Great Britain AMETEK GB > 5 Ashville Way > Molly Millars Lane > Wokingham > Berkshire RG41 2 PL > Great Britain Phone +44 845 074 0660 Internet: www.ametek-cts.com Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject to change without further notice. www.emtest.com EM TEST > PAGE 5/5