CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

Similar documents
CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

IEC Electrical fast transient / Burst immunity test

Voltage dips short interruptions with PFS and Netwave

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

Low Frequency Measuring System

Voltage Transient Emission Test

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

AC Power Sources. Newtons4th Ltd

Technical Specification

Schlöder GmbH - EMC Test and Measurement Systems Model #

Programmable AC Power Source Model 9801

METRAClip87 and 88 Clamp Multimeters

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Fluke Norma 4000/5000

ISO/TS ELECTRICAL DISTURBANCES BY CONDUCTION AND COUPLING PART 4: ELECTRICAL TRANSIENT CONDUCTION ALONG SHIELDED HIGH VOLTAGE SUPPLY LINES ONLY

TesT system for ConduCTed and radiated immunity

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

Fluke Norma 4000/5000

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

METRAClip85 and 86 Clamp Multimeters

FINAL DRAFT TECHNICAL REPORT CLC/FprTR RAPPORT TECHNIQUE TECHNISCHER BERICHT January English version

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

Combination Wave Test System

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

Applications. Other applications include:

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

True RMS Bench Multimeter 5492B

It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

VariTrans P D1 TRMS

DOBLE F6150e TECHNICAL SPECIFICATIONS

Insulation Test System

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

Vector Network Analyzers ZVB

MGA Magnetic field system. DC khz

AC/DC Converter LD20-26Bxx Series

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

Because you can t afford downtime

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

SM2000 TECHNICAL DESCRIPTION

Conducted Immunity Testing

SPECIFICATION. LED Driver. Model : SI-EPF006650WW CUSTOMER : SAMSUNG CHECKED APPROVED DRAWN SAMSUNG #2, NONGSEO-DONG, GIHEUNG-GU,

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607

AC/DC Power Sources ACS Series

Power Quality and Energy Measurement PEM575

Insulation Test System

AC/DC Power Sources ACS Series

Function/Arbitrary Waveform Generator

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

VariTrans P V. Safe and Sound.

RF Signal Generator SM300

A A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET

Arbitrary/Function Waveform Generators 4075B Series

Transcription:

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC 61000-4-16, IEC 61000-4-19 ANNEX C, 0HZ (DC) TO 165KHZ FOR TESTS ACCORDING TO... > EN 61000-4-16 > IEC 60255-22-7 > IEC 60533 > IEC 61000-4-16 > IEC 61000-4-19, Annex C > IEC 61326 > IEC 61543 > IEC 61850-3 > prtr 50579 CWS 500N4 - TESTING FOR IMMUNITY TO CONDUCTED, COMMON-MODE DISTURBANCES The CWS 500N4 is the state-of-the-art solution in a compact single-box design to test for immunity to conducted, common mode disturbances in the frequency range 0Hz (DC) to 165kHz. Such test requirements are specified in IEC 61000-4-16 and cover continuous mode testing as well as short term testing with DC, 16 2/3Hz, 50Hz and 60Hz with 4 test levels each plus a sweep mode from 10Hz to 165kHz. Additionally, the CWS 500N4 can be used for testing electricity metering equipment as per prtr 50579 and Draft standard IEC 61000-4-19, Annex C. HIGHLIGHTS > Most compact equipment for common-mode disturbances as per IEC 61000-4-16 > Built-in LF signal generator and LF amplifier > Sweep mode capability 10Hz to 165kHz > Built-in rectifier module for DC testing > Option for Electricity Meter testing acc IEC 61000-4-19 Annex C APPLICATION AREAS INDUSTRY RESIDENTIAL www.emtest.com EM TEST > PAGE 1/5

TESTING AS PER IEC/EN 61000-4-16 TESTING AS PER IEC/EN 61000-4-16 OUTPUT CHARACTERISTICS CONTINUOUS MODE DC, 16 2/3Hz, 50Hz and 60Hz 0.1-35 Vrms or DC 1V continuous 3V continuous 10V continuous 30V continuous Ripple on DC < 5% < 10% (sinusoidal waveform) OUTPUT CHARACTERISTICS SHORT-TERM MODE DC, 16 2/3Hz, 50Hz and 60Hz 1-330Vrms or DC 10V for 1s duration 30V for 1s duration 100V for 1s duration 300V for 1s duration Phase synchronisation < 10% (sinusoidal waveform) 0 ± 5% Ripple on DC < 5% Fall/rise time Note: between 1us and 5us These tests require either the optional MV 2606N2.2 motor variac or the optional programmable AC voltage source ACS 500N2.3. OUTPUT CHARACTERISTICS 15HZ - 165KHZ Frequency range 10Hz to 165kHz 0.1 to 35Vrms 1V - 0.1V - 1V 3V - 0.3V - 3V 10V - 1V - 10V 30V - 3V - 30V MEASUREMENT Voltage TEST ROUTINES Quick Start Service < 1% (sinusoidal waveform) internal rms measurement Immediate start; easy to use and fast discrete frequency testing Service, Set-up TESTING OF ELECTRICITY METERING EQUIPMENT AS PER TR-EN 50579 INTERFERENCES DISTURBANCES TESTING AS PER TR-EN 50579 AND IEC 61000-4-19 ANNEX C (OPTION) Total harmonic (THD) 2kHz to 150kHz Max. 3A up to 150kHz <5% at maximum level Accuracy better than ± 5% Frequency step Max. 1% Output impedance 1.0ohm (external decoupling impedance SH 1R) www.emtest.com EM TEST > PAGE 2/5

GENERAL DATA INTERFACE Serial interface USB Parallel interface IEEE 488, addresses 1-30 Fail 1 Fail 2 SOFTWARE icd.control GENERAL DATA Dimensions Weight Supply voltage Input power Fuses Cooling BNC input; test will be stopped immediately (when input becomes active low) BNC input; test will be stopped (when input becomes active low) and contiunued (input active high). After 10 fail events the test will be stopped. Extensive and most versatile remote control and reporting software. A standard library helps to configure the test setup. Part of delivery 19"/6HU, 555mm x 448mm x 286mm Approx. 30kg 115V - 230V +10/-15%, 50/60Hz Max. 600W Temperature 10 C - 40 C 2x6.3AT (115V) or 2x3.15AT (230V) 2x10AT for AC-source Active cooling, air ventilation ACCESSORIES COUPLING NETWORK CN 16-L2/L4 CN 16-L2.1 CN 16-L3 CN 16-L4/690V CN 16-L8 CDN 16-L2 CDN 16-L4/400 V 2-wire/4-wire coupling network, switchable, EUT Umax. AC: 440V 16.7Hz..80Hz, 2-wire coupling network, EUT Umax. AC: 300V 16.7Hz..80Hz, EUT Umax. DC: 220V, Power dissipation: max. 200W, active cooling,overtemperature protection, Mains: 85-265 V 50/60Hz, Fuse 1AT 3-wire coupling network, EUT Umax. AC: 440V 16.7Hz..80Hz, 4-wire coupling network, EUT Umax. AC: 3x690V 50/60Hz, 8-wire coupling network, EUT Umax. AC: 300 V 16.7Hz..80Hz, GEN IN Umax.: 330 V AC/DC, EUT Umax. DC: 160V, 2-wire coupling network, decoupling with isolation transformer, EUT Umax./ Imax.: 300V 16A GEN IN Umax.: 330VAC 4-wire coupling network, decoupling with isolation transformer EUT Umax./ Imax.: 3x480V 16A, GEN IN Umax.: 330VAC CDN 16-T2 Telecom T-network, 60VDC, 2A, EUT Umax.: 60VDC, EUT Frequency range: Telecom applications, www.emtest.com EM TEST > PAGE 3/5

ACCESSORIES COUPLING NETWORK CN 60255-22-7 4-wire coupling network as per IEC 60255-22-7, figs. 2, 3 and 4, common mode and differential mode coupling CN 61543 Coupling network as per IEC 61543 (100ohm) AC SOURCES ACS 500N2.3 MV 2606N2.2 AC power source 0-330VAC/2kVA, 10Hz - 80Hz, galvanically isolated; controlled by CWS 500N4 via serial interface Mains supply: 230V/16A, 50/60Hz Motor variac 0-330VAC/2kVA, 50Hz/60Hz, galvanically isolated; controlled by CWS 500N4 via 0-10V analog output Mains supply: 230V/9A, 50/60Hz EXTENSION FOR APPLICATION AS PER IEC 61000-4-19 ELM set ELM-R set (upgrade) Electricity meter test set as per IEC 61000-4-19 Annex C included: -SH ELM, 1R and 100R, Shunt resistor box and decoupling impedance, -Current meter ext., 5 1/2 digit, 150kHz, USB remote control with icd.control software, -USB remote cable -Cable set SH ELM to current meter Electricity meter test set as per IEC 61000-4-19 Annex C included: -CWS500N4 hardware upgrade and calibration, -SH ELM, 1R and 100R, Shunt resistor box and decoupling impedance, -Current meter ext., 5 1/2 digit, 150kHz, USB remote control with icd.control software, -USB remote cable -Cable set SH ELM to current meter -Call representative for details www.emtest.com EM TEST > PAGE 4/5

COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com Germany AMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Phone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: www.emtest.com > E-mail: info.cts@ametek.de France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Phone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr USA / Canada AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837 Phone +1 (732) 417-0501 Internet: www.emtest.com > E-mail: sales.emtest@ametek.com P.R. China E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Phone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: www.emtest.com > E-mail: info@emtest.com.cn Republic of Korea EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Phone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Poland EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Phone +48 (0)518 64 35 12 Internet: www.emtest.com/pl > E-mail: infopolska.emtest@ametek.com Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject to change without further notice. www.emtest.com EM TEST > PAGE 5/5