Operating Guide October 2006

Similar documents
MultiCube Multi-Function Electricity Meter. Installation and Operation

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

PM 305 Operating Guide

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Digital Multifunction Instrument - Rish Master 3440

Data Sheet. RISH Master Record %THD

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Technical Data Sheet AMIK 300 / 301

AMIK 200 / 201 Technical Data Sheet

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Contents. Introduction and description Package contents Device identification PM Options... 80

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Technical Data Sheet. x1000. kwh R Y B

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Centrale de mesure Power Meter PM500 Merlin Gerin

PLA 33. Power line analyzer. User and service manual. version 2.4

Installation and Operating Instructions

ULTRA RAPID POWER QUALITY ANALYZER

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Modular Metering System ModbusTCP Communications Manual

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Conzerv EM6400NG series

Energy Management Energy Meter Type EM340

DM-III MULTITEST Power Quality Recorder

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

Energy Management Energy Analyzer Type EM210 MID

Ziegler EM 1320/30/40

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

Energy Management Energy Analyzer Type EM112

INSTALLATION INSTRUCTIONS QUICK START GUIDE. Multi-transducer, MTR-3. Document no.: B SW version 3.0X.X or later

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

RISH Master 3440i/3440iDL 0.2S

MT 560/UMT TRANSDUCER & ANALYZER

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

Energy Management Modular Smart Power Transducer Type SPT-90

Current Clamp. 210

ASCO 5210 Digital Power Meter. Operator s Manual DANGER

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Energy Management Energy Meter GM3T E GM3T-RS485 E

RS Pro ENGLISH. Datasheet

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Technical Data Sheet

Installation Instructions and Reference Handbook. Installation instructions

ATK Clamp Meter

Integra 1560 and 1580 Digital Transducer Systems

UPM209 1/5A CT, 80A Multifunction three-phase meter

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Metering Devices, Protective Relays, Software and Connectivity

GSC57 Rel of 257/10/05

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

E50 MODBUS POINT MAP

Energy Management Energy Analyzer Type EM210

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Energy Management Energy Analyzer Type EM111

EM-72 Electricity Meters for Current Transformers

Digital Multifunction Meter - RISH Integra 2000

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Energy Management Modular Power Analyzers Type WM2-96

Energy Division

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

UT232. Operating Manual. Digital Power Clamp Meter

Energy Management Energy Meter Type EM21 72R Retro-Fit

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

Power-meters three-phase

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

RS Pro ENGLISH. Datasheet

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM111

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Transcription:

Operating Guide October 2006

Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which case you will be provided with additional details. Every effort has been made to ensure that the information in this manual is complete and accurate. We revised this manual but cannot be held responsible for errors or omissions. The apparatus has been designed and tested in accordance with EN 61010-1, Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use. This operating guide contains information and warnings which must be followed by the user to ensure safe operation and to maintain the apparatus in a safe condition. We reserve the right to make changes and improvements to the product without obligation to incorporate these changes and improvements into units previously shipped. 1.1 Warning Symbols This instruction manual gives details of safe installation and operation of the electricity meter. Safety may be impaired if the instructions are not followed. Labels on each meter give details of equipment ratings for safe operation. Take time to examine all labels before commencing installation. Safety symbols on the meter have specific meanings. Refer To User Manual Risk of Electric Shock WARNING The meter contains no user serviceable parts. Installation and commissioning should only be carried out by qualified personnel 1.2 Maintenance The equipment should be maintained in good working order. Damage to the product should be repaired by the manufacturer. The meter may be cleaned by wiping lightly with a soft cloth. No solvents or cleaning agents should be used. All inputs and supplies must be isolated before cleaning any part of the equipment. Further information is available at http://www.ndmeter.co.uk. 1.3 Waste Electrical/Electronic Equipment At the end of this products useful life it should be disposed of ONLY via a recycling center as defined by the EU WEEE directive. This product should not be incinerated. Page 2 Cube 400

Display 2 Display Pages Measured data is displayed on numerous pages organised in four Standard Menus and two Distortion Menus as follows: 2.1 Power Up The following screen is shown when auxiliary power is first supplied. CUbE SOFt 1.01 2.2 Current Menu Press the key to select from the available Current Menu pages. 200.0 A 200.0 200.0 Pk hold 220.0 A 220.0 220.0 Phase Amps Phase 1 true rms amps Phase 2 true rms amps. Phase 3 true rms amps. This display is updated every second. Peak Hold Phase Amps The maximum value of displayed phase amps. These are stored in non-volatile memory when the meter loses auxiliary power Press and to reset all three maximums to zero note 1. Page 3

Display T-Avg 200.0 A 200.0 200.0 Time-Averaged Amps The calculated average of phase amps taken over a user definable time period T VI (10s to 1800s). A rolling time window is used and the display updated every T VI /10 with the average of the most recent period displayed. Pk hold 200.0 A T-Avg 200.0 200.0 Peak Time-Averaged Amps The maximum value of Time- Averaged amps. These are stored in non-volatile memory when the meter loses auxiliary power Press and to reset all three maximums to zero note 1. 2.3 Voltage Menu Press the key to select from the available Voltage Menu pages. 230.0 230.0 V 230.0 Phase Volts Phase 1 to neutral true rms volts Phase 2 to neutral true rms volts. Phase 3 to neutral true rms volts. This display is updated every second. 400.0 L-L 400.0 V 400.0 Line Volts Line 1 true rms volts (Phases 1-2) Line 2 true rms volts (Phases 2-3) Line 3 true rms volts (Phases 3-1) This display is updated every second. Page 4 Cube 400

Pk hold 250.0 250.0 V 250.0 Display Peak Hold Phase Volts The maximum value of displayed phase volts. These are stored in non-volatile memory when the meter loses auxiliary power Press and to reset all three maximums to zero note 1. T-Avg 230.0 230.0 V 230.0 Time-Averaged Volts The calculated average of phase volts taken over a user definable time period T VI (10s to 1800s). A rolling time window is used and the display updated every T VI /10 with the average of the most recent period displayed. Pk hold 230.0 T-Avg 230.0 V 230.0 Peak Time-Averaged Volts The maximum value of Time- Averaged volts. These are stored in non-volatile memory when the meter loses auxiliary power Press and to reset all three maximums to zero note 1. Page 5

Display 2.4 Power Menu Press the key to select from the available Power Menu pages. - 239.0 KVAr 3- Phase 276.0 KVA 138.0 KW System Power System Reactive Power (var) System Active Power (VA) System Real Power (Watts) A symbol after the var value indicates a capacitive load. A negative sign before the var readings indicates export reactive power. 46.00 46.00 Phase Watts Phase 1 true rms watts Phase 2 true rms watts. Phase 3 true rms watts 46.00 KW 10.0 bal A 50.0 Hz 3- Phase COSΦ 1.000 System Page 2 Balance current. (I1+I2+I3) Frequency (Measured on V1) System Power Factor A symbol after the power factor value indicates a capacitive load. 46.00 kva 46.00 46.00 Phase VA Phase 1 true rms VA Phase 2 true rms VA. Phase 3 true rms VA Page 6 Cube 400

Display - 46.00 kvar - 46.00-46.00 Phase VAr Phase 1 true rms Var. Phase 2 true rms Var. Phase 3 true rms Var. A symbol after a var value indicates a capacitive load. A negative sign before a var reading indicates export reactive power. 1.000 1.000 1.000 COSΦ Phase Power Factor Phase 1 Power Factor. Phase 2 Power Factor. Phase 3 Power Factor. A symbol after each value indicates a capacitive load. MD 239.0 KVAr 3- Phase 276.0 KVA 138.0 KW Pk hold MD 239.0 KVAr 3- Phase 276.0 KVA 138.0 KW Power Mean Demand (MD) The calculated average of the system power values taken over a user definable time period T p (1min to 60min). A rolling time window is used and the display updated every T p /60 with the averages of the most recent period displayed. Peak Hold MD The maximum value of each power MD value. These are stored in non-volatile memory when the meter loses auxiliary power Press and to reset all three maximums to zero note 1. NOTE 1: Meters may be installed with the option to reset all peak hold values using the front keys disabled. Page 7

Display 2.5 Energy Menu Press the key to select from the available Energy Menu pages. 123456.78 123456.78 kwh kvarh Real Energy (Wh) This register accumulates only when real power (kw) is positive (import). This value returns to 0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. Reactive Energy (VArh) Import varh Accumulating register. This value returns to 0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. 123456.78 kva h Apparent Energy (VAh) Import VAh Accumulating register. This value returns to 0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. HRS Run 1234567.8 Hours Run Note 2 This register accumulates time in Hours only while real power (kwh) is above a user set level (see programming section). This value returns to 0.0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. Page 8 Cube 400

Display Export kwh 123456.78 Export kvarh 123456.78 Export kwh Note 2 This register accumulates only when real power (kw) is negative (export). This value returns to 0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. Export kvarh Note 2 This register accumulates only when reactive power (kvar) is negative (export). This value returns to 0 when the value exceeds 99999999. This register is stored in nonvolatile memory when auxiliary power is not supplied to the meter. NOTE 2: Hours Run, Export kwh and Export kvarh are factory fitted options. If these options are not supplied relevant page(s) will be omitted. Meters may be supplied with an option to reset energy registers to zero using the front keys. If the option is fitted, press and together and hold for approximately 3 seconds to simultaneously reset all energy registers to zero. Once reset the registers may not be recovered. Page 9

Display 2.6 Power Quality Menus To enter/exit power quality display mode press and together and hold for approximately 3 seconds. 2.6.1 Amps Power Quality Menu Press the key to select the Amps Power Quality Sub Menu. Press or keys to select the next/previous Amps Power Quality page. THD 20.0 20.0 A% 20.0 Amps Total Harmonic Distortion Phase 1 Amps THD Phase 2 Amps THD. Phase 3 Amps THD. This display is updated every second. THD is scaled as 0-100.0%. 10.0 10.0 A% 02 10.0 harmonic Amps Individual Harmonics 02-15 Phase 1 Amps harmonic 02-15 Phase 2 Amps harmonic 02-15 Phase 3 Amps harmonic 02-15. The harmonics are scaled as a percentage of the fundamental rms amps value. This example shows 10.0% second harmonic. Page 10 Cube 400

Display 2.6.2 Volts Power Quality Menu Press the key to select the Volts Power Quality Sub Menu. Press or keys to select the next/previous Volts Power Quality page. THD 20.0 20.0 V % 20.0 Volts Total Harmonic Distortion Phase 1 Volts THD Phase 2 Volts THD. Phase 3 Volts THD. This display is updated every second. THD is scaled as 0-100.0%. 10.0 10.0 V % 02 10.0 harmonic Volts Individual Harmonics 02-15 Phase 1 Volts harmonic 02-15 Phase 2 Volts harmonic 02-15 Phase 3 Volts harmonic 02-15. The harmonics are scaled as a percentage of the fundamental rms volts value. This example shows 10.0% second harmonic. Page 11

Display 2.7 Display Scaling Measured values displayed on the LCD are scaled by the user settings of CT and/or PT primaries to provide optimum resolution. 2.7.1 Voltage Scaling) PT Setting Resolution 10V L-L - 80V L-L 0.01 V 81V L-L - 800V L-L 0.1 V 801V L-L 8,000V L-L 1 V 8,001V L-L - 80,000V L-L 0.01 kv 80,001V L-L - 440,000V L-L 0.1 kv 2.7.2 Current Scaling CT Setting Resolution 5A - 8A 0.001 A 9A - 80A 0.01 A 81A - 800A 0.1 A 801A 8,000A 1 A 8,001A 25,000A 0.01 ka 2.7.3 Power Scaling (W, VA, var) PT Setting x CT Setting Phase Power Resolution System Power Resolution 100VA - 1,400VA 0.1 W 0.001 kw 1,401VA 14,000VA 0.001 kw 0.01 kw 14,001VA - 140,000VA 0.01 kw 0.1 kw 140,001VA - 1,400,000VA 0.1 kw 1 kw 1,400,001VA - 14,000,000VA 1 kw 0.01 MW 14,000,001VA - 140,000,000VA 0.01 MW 0.1 MW 140,000,001VA 1,000,000,000VA 0.1 MW 1 MW 2.7.4 Energy Registers (Wh, VAh, varh) PT Setting x CT Setting 100VA - 1,400VA 1,401VA - 14,000VA 14,001VA - 140,000VA 140,001VA - 1,400,000VA 1,400,001VA - 14,000,000VA 14,000,001VA - 140,000,000VA 140,000,001VA 1,000,000,000VA Resolution.001 kwh 0.01 kwh 0.1 kwh 1 kwh 0.01 MWh 0.1 MWh 1 MWh Page 12 Cube 400

Display 2.7.5 Miscellaneous All Settings Resolution System and Phase PF 0.001 Amps and Volts % THD 0.1% Amps and Volts % Harmonic 0.1% Frequency 0.1 hz Page 13

Connections 3 Connection 3.1 Mounting In a Panel Panels should be 1mm to 4mm thick with a square cutout of 92mm (+0.8/-0.0mm). Insert the meter from the front of the panel, slide the panel clips from the rear of the case and push firmly against the panel ensuring even pressure on each clip. 3.2 Pulse Output Connection The pulse outputs take the form of isolated volt free normally open contact pairs. The contacts are isolated from all other circuits (2.5kV / 1 minute) and at 50V from pulse1 to pulse 2. The pulses can be used as an input to a remote counter, pulse logger, building energy management system etc. Pulse Output Connections Page 14 Cube 400

Connection 3.3 Input Connections 3-Phase 3 or 4-Wire (*Optional Neutral) 3-Phase 3-Wire Page 15

Connections 3-Phase High Voltage (HV) Single Phase Page 16 Cube 400

4 Pulse Outputs Pulse Outputs Two isolated pulse outputs are provided for connection to external systems such as Building Energy Management Systems (BEMS), data loggers, remote counters etc. Pulse 1 is always associated with the active energy (kwh) register. Pulse 2 is normally associated with the reactive energy (kvarh) register but meters may be supplied with this pulse linked to the kvah register. A single pulse occurs for each unit of energy on the display (eg 1 pulse per 0.1kWh). The pulse rate (amount of energy associated with each pulse) and pulse length may be set to suit the external system. 4.1.1 Pulse LEDs Light emitting diodes (LEDs) on the front panel of the instrument remain ON during each associated output pulse. Pulse Output Indicators Page 17

Meter Setup 5 Meter Setup 5.1 Programming Menu To enter programming mode: Hold and together for 5 Seconds. 4-Digit Security Code COdE 1234 This page is only shown if a security code greater than 0 is set via serial communication. Press or to select each digit (least significant first) Press to move to the next most significant digit. A correct 4 digit security code is required to access other programming menu pages. Current Transformer Primary Ct Pri L 200 Potential Transformer Primary Pt Pri V L-L L 400 A Press or to select from the standard list of CT primaries while L is displayed. (List Mode) Press or to increase or decrease the value by 10 while F is displayed. (Fine adjust) Press and together to toggle between L and F. Press value. to accept the set Press or to select from the standard list of PT primaries while L is displayed. (List Mode) Press or to increase or decrease the value by 10 while F is displayed. (Fine adjust) Press and together to toggle between L and F. Press value. to accept the set Page 18 Cube 400

Meter Setup Power MD Integration Period MD (Note 1) PER >?I N 30 Current/Voltage Time Ave Period T-Avg Hours Run Set Point PER SEC 10 (Note 1) (Note 1) HRS Run SEt 250 kw This sets the integration period in minutes used for the sliding time window MD calculation for power. Press or to increment or decrement the value. Press value. to accept the set This sets the integration period in seconds used for the sliding time window average calculation for current and voltage. Press or to increment or decrement the value. Press value. to accept the set This sets the instantaneous system kw level above which the Hours Run timer will accumulate. Below this level Hours Run will remain unchanged. Press or to increment or decrement the value. The speed of change will increase as the button is held. Press value. to accept the set Page 19

Meter Setup Pulse Rate Pulse Length PULS RATE 0.1 PULS LEN 0.1 kwh This sets the amount of energy (kwh) required to trigger each Pulse 1 output. Pulse 2 is set at the same rate but linked to a different register (eg kvarh). Press or to select the next/previous Pulse Rate from a standard list. Press value. to accept the set This sets the contact closure time for both pulse outputs. Press or to select the next/previous Pulse Length from a standard list. Press value. to accept the set Pulse Test PULS test HLd 999 This allows the commissioning engineer to test both pulse outputs and associated circuits without the need of a test load. Press or to start/stop a test pulse stream. The display shows Hld (Hold) or RUN respectively. The counter shows the total number of pulses during the test. Press and to reset the test counter to zero. Press value. to accept the set Note 1. Some setup screens are only available on meters with corresponding measurement options. Page 20 Cube 400

Specification Specification Aux Supply Input Voltage Input Currents Accuracy KWh: LCD Display Nominal 230Vac ±15%, 45-65Hz, 1W max. Optional 115Vac ±15%. Isolation 2.5kV (1 minute) Un 400V Line-Line. Range 20%-120% Un Burden 0.1VA / Phase. Overload 2xUn Continuous. Other nominal voltages are available to order. Nominal Ib = 5A. Range 0.2%-120% Ib Burden 0.1VA / Phase. Overload 40xIb (0.5 sec) Isolation 2.5kV (1 minute) (50V Pulse1-Pulse2) Optional Ib = 1A Cl.1.EN62053-21 & BS8431 (2-120% Nom kw) Kvarh: Cl.2.0. EN62053-23 KW: 1% Rdg (5% - 120% Nom kw) Amps: 0.2% Ib or 1.0% Rdg (0.05Ib < Iph < 1.2Ib) Volts: 0.2% Un or 1.0% Rdg (0.2Un < Vph < 1.2Un) PF: ±0.2 Degrees Frequency: ±0.05hz (45hz F 65hz) LCD 8 Digits h=6.7mm + Legends h=3.2mm. kwh Memory 10 years without power. Normally open volt free contacts Pulse rate and length selectable. Contacts: 100V ac/dc, 100mA, 5W max Isolation 2.5kV for 1 minute. Operate-10 C > T < 65 C. RH < 75% Non Condensing Storage- 25C > T < 75C IP 54 (IP65 with optional kit) Other Size: 96 x 96 x 83.5mm (72mm behind panel) Case: DIN 96x96mm Mablex UL94-V0 Terminals: Rising Cage 4.0mm 2 Weight: Approx 250g Pulse Outputs Environment Page 21