PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

Similar documents
SECTION HOLLOW METAL DOORS AND FRAMES

SECTION BULLET- RESISTANT DOORS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee

SECTION HOLLOW METAL DOORS AND FRAMES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

C-Series & S-Series Classic Frame with Transom (Single or Pair)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

MANUFACTURING INC. Specifications

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

A. Provide all finish carpentry needed for a complete and proper installation.

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

ARCHITECTURAL STICK SYSTEMS

THIS PAGE INTENTIONALLY LEFT BLANK

Series 9000 Vinyl Single Hung

SECTION INTERIOR SIGNAGE

Product Guide Specification For Nonrated & 20-Minute Rated Doors

Series 6000 Vinyl Single Hung

Subject: Specification Compliance

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

HOLLOW METAL DOORS AND FRAMES

INTERIOR ALUMINUM DOORS AND FRAMES

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Toll-Free

Design and Construction Standards SECTION ATHLETIC LOCKERS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Series 6000 Vinyl Horizontal Slider

SECTION METAL DOORS & FRAMES PART 1 GENERAL 1.01 SUMMARY:

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

Series 9000 Vinyl Horizontal Slider

SECTION WOOD DOORS

MOVEABLE GLASS WALL TECHNICAL DATA

Bovard Studios Inc. Section April 6, 2004 Page 1

SECTION Display Case Door Series 1301-CM

SECTION STILELITE TM STEEL DOORS AND FRAMING. glass moldings and stops as shown in the approved submittal drawings.

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Through and through, our metal frames stand strong.

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

4. Metal roof jacks at penetrations and attachments

STANDARD ENTRANCES TECHNICAL MANUAL

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION SHEET METAL FLASHING AND TRIM

HMMA 861 GUIDE SPECIFICATIONS FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES -00 AMERICAN NATIONAL STANDARD ANSI/NAAMM METAL DOORS & FRAMES

Thermally Broken Framing and Door Installation

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

INSTALLATION INSTRUCTIONS

Masonry Frames Interior/Exterior* Drywall Frames Interior**

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Series 9000 Vinyl Fixed Window

SECTION WOOD ACCORDION FOLDING DOORS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

Table of Contents F Series Frames

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

Versatrac R-System Stock Extrusions, Clips and Accessories

SPLIT FRAME INSTALLATION INSTRUCTIONS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Heavy Wall Applied Stop Tube Frame and Door Installation

Versatrac R-System Stock Extrusions, Clips and Accessories

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

Solid Core Wood Door / Steel Frame Packages

Copyright 2010 AlA MasterSpec Short Form 02/10 SECTION HOLLOW METAL DOORS AND FRAMES PART 1- GENERAL 1.1 SUMMARY 1.

Pre-Hung Entry Door Systems

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION CARPENTRY

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

SECTION ARCHITECTURAL WOOD CASEWORK

HMMA GUIDE SPECIFICATIONS FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM SEVENTH EDITION

Series 9000 Vinyl Fixed Window

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

Ash Brook Golf Course Scotch Plains, New Jersey

SECTION MANUFACTURED CASEWORK

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Please read and understand all instructions before beginning. These instructions cover the non-impact aluminum French Door 101.

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

HMMA 861 GUIDE SPECIFICATIONS FOR COMMERICAL HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL. SEVENTH EDITION September 15, 2014

B. Related Requirements: 1. Section "Interior Painting" for priming and backpriming of interior finish carpentry.

Imagine a front entrance that is distinctively yours. Upstate Door will work with

PRODUCT DATA CATALOG

HMMA GUIDE SPECIFICATIONS FOR STAINLESS STEEL HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL AMERCAN NATIONAL STANDARD SECOND EDITION

Design Considera ons & Installa on Guidance

SECTION PANELBOARDS

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

Product Guide Specification

Versatrim Side-Snap Frame

SECTION INTERIOR FINISH CARPENTRY

FIBERGLASS DOOR SYSTEM Installation Instructions

SECTION SHEET METAL FLASHING AND TRIM

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Guide Specification Section Interior Aluminum Doors and Frames

GUIDELINE SPECIFICATIONS

910 East Saint Andrew St. Rapid City, SD Phone: (605) Fax: (605) Custom Doors and Frames

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Transcription:

SECTION 08 1213.17 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Prefinished steel door frames. B. [Sidelites] [, borrowed lites] [, and transom] assemblies. 1.02 RELATED REQUIREMENTS A. Section 06 2000 Finish Carpentry: Wood casings. B. Section 08 1113 Hollow Metal Doors and Frames: Metal doors. C. Section 08 1416 Flush Wood Doors. D. Section 08 1613 Fiberglass Doors. E. Section 08 7100 Door Hardware. F. Section 08 8000 Glazing: Glass and glazing. 1.03 REFERENCE STANDARDS A. AAMA 2604 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels (with Coil Coating Appendix); 2017a. B. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010. C. ANSI/SDI A250.6 - Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames; 2003 (R2009). D. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process; 2017. E. ASTM B117 Standard Practice for Operating Salt Spray (Fog) Apparatus; 2016. F. ASTM D714 - Standard Test Method for Evaluating Degree of Blistering of Paints; 02(2017). G. ASTM D1654 - Standard Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments; 08(2016) e1. H. ASTM D2794 - Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact); 93(2010). I. ASTM D3363 - Standard Test Method for Film Hardness by Pencil Test; 05(2011) e2. J. BHMA/ANSI A156.115 - American National Standard for Hardware Preparation in Steel Doors and Steel Frames; 2016. K. NFPA 80 - Standard for Fire Doors and Other Opening Protectives; 2016. L. UL 10C - Standard for Positive Pressure Fire Tests of Door Assemblies; Current Edition. 1.04 SUBMITTALS A. See Section 01 3000 - Administrative Requirements for submittal procedures. FILE NAME 08 1213.17-1

B. Product Data: Submit product data, including manufacturer s product sheet, for specified products. Include details of design and construction and installation instructions. C. Shop Drawings: Submit shop drawings showing layout, profiles and product components, including anchorage, accessories, finish colors and textures. 1. Indicate installation requirements of finish hardware and reinforcements. D. Samples: Submit the following for selection and verification of finishes, colors and textures. 1. Sample of door frame construction, complete with snap-on casings. 2. Samples of factory stocked colors of prefinished components. 3. Samples of custom colors for color matching. E. Certificate: Certify that products of this section meet or exceed specified requirements. F. Test Reports: Submit certified test reports showing compliance with specified performance characteristics and physical properties G. Manufacturer's Qualification Statement. H. Installer s Qualification Statement. 1.05 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section, with not less than three years of documented experience. B. Installer Qualifications: Company experienced in performing work of this section with not less than three years of experience in installation of work similar to this project. C. Testing Agencies: Fire-rated steel frames shall be of types tested and approved by Intertek Testing Services, Warnock Hersey and shall bear labels of same. 1. Three-sided frames shall receive Warnock Hersey Mark for applicable fire rating label. 2. Sidelite and borrowed lite frames shall receive Warnock Hersey Mark for applicable fire rating label. 1.06 1.06 DELIVERY, STORAGE, AND HANDLING A. Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. 1. Factory package components in protective cartons to prevent damage during shipping. B. Store materials protected from exposure to harmful weather and at temperature conditions recommended by manufacturer. 1. Store material on wooden skids under cover in a protected area and keep vented to avoid condensation until ready for installation. 1.07 FIELD CONDITIONS A. Field Measurements: Verify size of openings by field measurements before fabrication, and show recorded measurements on shop drawings. B. Coordinate field measurements and fabrication schedule with construction progress schedule to avoid construction delays. PART 2 - PRODUCTS 2.01 MANUFACTURERS A. Prefinished Steel Door Frames: 1. International Door Products Inc. (IDP Inc.). 2. Address: 21300 West 8 Mile Rd., Southfield, MI 48075. 3. Phone: (248) 352-0044. 4. Fax: (248) 352-4222. 5. Website: www.idpframes.com. FILE NAME 08 1213.17-2

6. Email: info@idpframes.com. 7. Obtain prefinished steel door frames from single manufacturer. 2.02 WITH APPLIED CASINGS A. Frames: Fabricated from corrosion resistant galvannealed steel in accordance with ASTM A653/A653M with separate jamb and head and snap-on casings for both sides to conceal fasteners. 1. Metal Thickness: 18 gage, 0.0478 inch (1.21 mm), nominal. 2. Door Thickness: [As indicated on drawings] [1-3/8 inch (35 mm)] [1-3/4 inch (44.5 mm)]. 3. Wall Thickness: [As indicated on drawings] [4-1/2 inch (114.3 mm), minimum wall thickness for 90 minute fire rating] [ ]. 4. Fire Rating: [As indicated on drawings] [90 minutes] [45 minutes] [20 minutes], and tested in accordance with UL 10C for positive pressure fire tests and certified by Warnock Hersey. 5. Applications: [As indicated on drawings] [Frames only] [Frames and sidelites] [Frames, sidelites, and borrowed lites] [ ]. 6. Provide accessories and fasteners as necessary for field assembly and installation in accordance with frame manufacturer s standards. 7. Prepare for reinforcements as provided in accordance with manufacturer s standards as required to receive finished hardware. 8. Fabricate jamb to interlock with header piece and forming strong joint. 9. Fabricate sidelite and borrowed lite frames as specified for door frames, and provide concealed field applied mullion clips for securing mullions to head/jamb members. 10. Form fixed glazing stops integral with frame members, and provide removable metal stops with prepunched screw holes and installation screws. B. Standard Steel Door Fixed Frames for Interior and Exterior Applications: 1. Frame Type: [As indicated on drawings] [Single rabbet] [Double rabbet] [Cased opening] [Pocket door frame] [ ]. 2. Door Type: [As indicated on drawings] [Standard door] [Pocket door] [ ]. 3. Product: Entry Fit F-Series by International Door Products Inc. (IDP Inc.). C. Kerfed Steel Door Fixed Frames for Interior and Exterior Applications: 1. Frame Type: [As indicated on drawings] [Double rabbet] [ ] with kerf in door stop for attachment of weatherstripping. 2. Door Type: [As indicated on drawings] [Standard door] [ ]. 3. Product: Entry Fit KF-Series by International Door Products Inc. (IDP Inc.). D. Adjustable Split Double Rabbet Kerfed Steel Door Frames for Interior and Exterior Applications: 1. Frame Type: [As indicated on drawings] [Double rabbet] [ ] with kerf cut in door stop for attachment of weatherstripping. 2. Door Type: [As indicated on drawings] [Standard door] [ ]. 3. Closure Trim: [22 gage, 0.0299 inch (0.76mm), nominal] [18 gage, 0.0478 inch (1.21 mm), nominal] thickness, with 16 gage, 0.0598 inch (1.52 mm) thick retainer, projection welded six places on each jamb and three places on header. 4. Product: Entry Fit K2A-Series by International Door Products Inc. (IDP Inc.). E. Adjustable Double Rabbet Steel Door Frames for Interior Applications: 1. Frame Type: [As indicated on drawings] [Double rabbet] [ ]. 2. Door Type: [As indicated on drawings] [Standard door] [ ]. 3. Closure Trim: [22 gage, 0.0299 inch (0.76mm), nominal] [18 gage, 0.0478 inch (1.21 mm), nominal] thickness, with 16 gage, 0.0598 inch (1.52 mm) thick retainer, projection welded six places on each jamb and three places on header. 4. Product: Entry Fit NK2A-Series by International Door Products Inc. (IDP Inc.). F. Casings: Provide die cut mitered metal casings held tight together and in alignment with concealed corner backing pieces. FILE NAME 08 1213.17-3

1. Steel: 22 gage, 0.0299 inch (0.76 mm) thick galvanized steel in accordance with ASTM A653/A653M. a. Width: 1-7/16 inch (36.8 mm), nominal. b. Height: 5/16 inch (8.6 mm), nominal. c. Finish: Prefinished casing to match frame. 2. Aluminum: 16 gage, 0.050 inch (1.27 mm) thick extruded aluminum alloy 6063-T5 temper. a. Width: 1-1/2 inch (38 mm), nominal. b. Height: 7/16 inch (11 mm), nominal. c. Finish: Prefinished casing to match frame. 3. Steel Colonial: 22 gage, 0.0299 inch (0.76 mm) thick galvanized steel in accordance with ASTM A653/A653M. a. Width: 1-3/4 inch (45.2 mm), nominal. b. Shaped Colonial Style: 9/16 inch (14.7 mm), nominal, on wider side. c. Finish: Prefinished casing to match frame. G. Wood Casing: [Medium density fiberboard (MDF)] [Poplar] [Oak] [Cherry] [ ] wood type and profile [as indicated on drawings] [ ]. 1. Refer to Section 06 2000. 2.03 FINISHES A. Factory Finish: Factory primed with 3 mil, 0.003 inch (0.076 mm) dry film thickness (DFT) and premium quality powder coated finish conforming to AAMA 2604 applied over cleaned and phosphate coated surface using electrostatic method. 1. Impact Resistance: Meets 100 inch lbs (110.8 meter kilograms) in both direct and reverse in accordance with ASTM D2794. 2. Salt Spray and Humidity Tests: Factory finished paint passes salt spray test conforming to ASTM D1654 and 3000 hour humidity test conforming to ASTM D714 with no blistering. 3. Paint Hardness: Factory finish paint meets calibrated pencil test conforming to ASTM D3363 for film hardness. 4. Color: [IDP White] [IDP Brown] [Satin Black] [Sky White] [Pale Brown] [Polar White] [RAL 1013] [RAL ] [ ]. B. Factory Primed: Factory primed, ready for field applied finish. 1. Field paint prime painted frames within 30 days of installation with a good quality oil based enamel as recommended, or a high quality water base latex; use flash rust inhibitor with water base latex method. 2. Color: White. 2.04 ACCESSORIES A. Hardware Preparations: Conforming to approved hardware schedule, BHMA/ANSI A156.115, and manufacturer s recommendations. 1. Mortise frames for hinges and strikes. 2. Drill and tap or reinforce frames for mortised or surface mounted hardware. 3. Refer to Section 08 7100. B. Hardware Reinforcing: Conform to ANSI/SDI A250.6 recommended practices. 1. Standard Hinges: 4-1/2 inch (114.3 mm) high, and 10 gage, 0.1345 inch (3.42 mm) thick galvanized steel in accordance with ASTM A653/A653M. 2. 4 inch and 3-1/2 inch High Hinges: 11 gage, 0.1196 inch (3.04 mm) thick steel in accordance with ASTM A653/A653M. 3. Strikes and Deadbolt Covers: 11 gage, 0.1196 inch (3.04 mm) thick steel in accordance with ASTM A653/A653M. 4. Door Closer Reinforcement: Steel or aluminum in accordance with manufacturer s standard. 5. Standard Arm Mounting: Extruded aluminum alloy 6063-T5 temper in accordance with manufacturer s standard. 6. Door Guard: Extruded aluminum alloy 6063-T5 temper in accordance with manufacturer s standard. 7. Parallel Mounted Arm, Field Installed: 12 gage, 0.1046 inch (2.66 mm) thick, galvannealed steel in accordance with ASTM A653/A653M. C. Casing Corner Alignment Clips: Injection molded plastic. FILE NAME 08 1213.17-4

D. Clear Adhesive Silencers, Weatherstripping and Smoke Gasketing (Standard Profile): In accordance with manufacturer s standard. 1. Interior Frames: Install clear adhesive silencers on header and strike jamb; single door opening, one per header, two per strike jamb; pair door opening, two per header. E. Exterior and Fire-Rated Frames: Provide weatherstripping and smoke gasket material to seal opening; material must compress to 1/16 inch (1.59 mm) thick. F. Kerf Profile Weatherstripping and Smoke Gasketing: At interior and exterior frames, provide kerf profile weatherstripping to seal opening. 1. Acceptable Product: Schlegel QEBD 50 or approved equivalent. G. Removable Glazing Bead for Sidelite and Borrowed Lite Frames: 16 gage, 0.0598 inch (1.52 mm) thick galvannealed A60/ZF180 steel in accordance with ASTM A653/A653M, 5/8 inch (15.9 mm) by 5/8 inch (15.9 mm), and prepunched for #6 by 1-1/4 inch (31.8 mm) long bugle-head self-tapping screws. H. Door Sill: Extruded aluminum with manufacturer s standard finish, compliant with ADA Standards [saddle type] [tile back type] [5 inch (127 mm) wide] [6 inch (152 mm) wide] [7 inch (178 mm) wide] [8 inch 201 mm) wide] [high sill type] [, with 1 inch (25.4 mm) sill extension] [, with 2 inch (51 mm) sill extension]. I. Hollow Metal Doors: Refer to Section 08 1113. J. Flush Wood Doors: Refer to Section 08 1416. K. Fiberglass Doors: Refer to Section 08 1613. L. Glass and Glazing: Refer to Section 08 8000. PART 3 - EXECUTION 3.01 VERIFICATION OF CONDITIONS A. Verify that substrate conditions of previously installed work are acceptable for product installation in accordance with manufacturer s instructions. B. Verify opening and dimensions with shop drawings, and use door as template to ensure proper alignment and clearances. 3.02 INSTALLATION A. Install prefinished steel door frames plumb and square, in accordance with shop drawings and manufacturer s instructions. B. Attach hinges and hang door in frame, and adjust frame to door for equal and uniform clearance between top and sides of door and frame. C. Secure frame to wall with appropriate type of fasteners. D. Install casing on frame. E. Install silencers on interior door frames. F. Install weatherstripping on exterior door frames. G. Install smoke gaskets as required. H. Adjust strike plate to hold door tight to stops when closed. I. Install fire-rated door frames in accordance with NFPA 80. 3.03 CLEANING A. Cleaning: Remove temporary coverings and protection of adjacent work areas. FILE NAME 08 1213.17-5

B. Repair or replace damaged installed products, and clean installed products in accordance with manufacturer s instructions prior to Date of Substantial Completion. C. Remove construction debris from project site and legally dispose of debris. [See Section 01 7419 - Construction Waste Management and Disposal for additional requirements.] 3.04 PROTECTION A. Protect installed product and finish surfaces from damage until Date of Substantial Completion. B. Repair or replace damaged or defective frames. C. Touch up damaged areas of factory-applied finishes with aerosol spray of color and paint to match. END OF SECTION FILE NAME 08 1213.17-6