LFR: flexible, clip-around current probe for use in power measurements

Similar documents
RCTi and RCTi-3ph Technical Notes

RCTrms Technical Notes

CWT Ultra Mini Technical Notes

The practicalities of measuring fast switching currents in power electronics using Rogowski probes

INSTRUCTIONS FOR USE

ROGOWSKI CURRENT WAVEFORM TRANSDUCERS INSTRUCTIONS FOR USE CWT ULTRA MINI. POWER ELECTRONIC MEASUREMENTS Ltd.

AIM & THURLBY THANDAR INSTRUMENTS

Flexible AC current probes

ROGOWSKI CURRENT WAVEFORM TRANSDUCERS INSTRUCTIONS FOR USE CWT. POWER ELECTRONIC MEASUREMENTS Ltd.

AIM & THURLBY THANDAR INSTRUMENTS

How to Select the Right Current Probe APPLICATION NOTE

Specification for the CCDPS DAQ/Control Capacitor Charge/Discharge Power Supply (CCDPS) for FLARE

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

1. High Frequency Performance

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

ULTRASTAB I U Precision

RAZTEC LINK CURRENT SENSOR TECHNICAL INFORMATION

ULTRASTAB IHF Precision Current Transducer

AC/DC Current Probe CT6844/CT6845/CT6846

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER

High-precision, Wideband, Highly Stable Current Sensing Technology

Current transducer FHS 40-P/SP600

A New Method for the Calibration of the mv Ranges of an AC Measurement Standard

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

Current clamps for AC current

Current Probes. User Manual

Experiment 1: Instrument Familiarization (8/28/06)

Experiment 1: Instrument Familiarization

Chapter 9. Evaluation and Measurement

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Lab 4. Crystal Oscillator

CT Current. Transformer. Higher frequency Higher sensitivity Higher temperature More accuracy

World-Class Accuracy & Measurement Range (40 Conventional Models)

EIS Measurement of a Very Low Impedance Lithium Ion Battery

IsoVu Optically Isolated DC - 1 GHz Measurement System Offers >120 db CMRR with 2kV Common Mode Range

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

Contents Summary Application. 2 Electrical Specifications...3 Products and Accessories... 4 Products Accessories Typical Mechanical

FISCHER CUSTOM COMMUNICATIONS, INC.

Keysight Technologies How to Select the Right Current Probe. Application Note

The design of Ruthroff broadband voltage transformers M. Ehrenfried G8JNJ

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Channel Characteristics and Impairments

AN OVERVIEW OF ROGOWSKI COIL CURRENT SENSING TECHNOLOGY

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

INSTRUCTIONS FOR USE

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

Small and light weight at 32kg Peak continuous fields up to 3.7 T for 5mm pole face diameter at 2mm gap Any mounting orientation Fast cycle times

Laplace Instruments Ltd LAPLACE INSTRUMENTS LTD RF300. Large Loop Antenna. (Van Leen Loop) 2 metre diameter. Mk II-A. USER MANUAL Ver 2.

Measuring Power Line Impedance

note application Measurement of Frequency Stability and Phase Noise by David Owen

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Magnetic induction with Cobra3

Homework Assignment 10

Trees, vegetation, buildings etc.

Data Sheet. Hall effect transducers, current and voltage

Lab 10: Single Supply Amplifier

Measurement and Analysis for Switchmode Power Design


Non-Contact AC Voltage Probe SP3000, AC Voltage Probe SP9001

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

EK307 Passive Filters and Steady State Frequency Response

Current Sensor: ACS750xCA-100

Glossary of VCO terms

Model Operating Manual

Electron Spin Resonance v2.0

Rogowski Coil Based Digital Energy Meter

Testing Power Sources for Stability

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

RF300 LARGE LOOP ANTENNA

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

Low_Pass_Filter_1st_Order -- Overview

13 th Asian Physics Olympiad India Experimental Competition Wednesday, 2 nd May 2012

William Thomson, Lord Kelvin, CAS2004. High Precision Measurements - Gunnar Fernqvist/CERN 1

Experiment 4: Grounding and Shielding

AN-1106 Custom Instrumentation Amplifier Design Author: Craig Cary Date: January 16, 2017

MEASUREMENT AND STANDARDS

AC/DC Current Oscilloscope Probe Model SL261

InstrumentationTools.com

Laboratory 4 Operational Amplifier Department of Mechanical and Aerospace Engineering University of California, San Diego MAE170

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

Homework Assignment 13

Table of Contents...2. About the Tutorial...6. Audience...6. Prerequisites...6. Copyright & Disclaimer EMI INTRODUCTION Voltmeter...

Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

EE431 Lab 1 Operational Amplifiers

Experiment 5: Grounding and Shielding

Implementing Automated Oscilloscope Calibration Systems

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

I = I 0 cos 2 θ (1.1)

Demonstrating Electromagnetic Noise in an Undergraduate Measurement and Instrumentation Course

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Instrumentation amplifier

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

EE 3305 Lab I Revised July 18, 2003

User s Manual for Integrator Short Pulse ISP16 10JUN2016

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Current transducer FHS 40-P/SP600

Op-Amp Simulation Part II

Transcription:

LFR: flexible, clip-around current probe for use in power measurements These technical notes should be read in conjunction with the LFR short-form datasheet. Power Electronic Measurements Ltd Nottingham UK Tel: +44 (0) 115 946 9657 Fax:+ 44 (0) 115 946 8515 Email: info@pemuk.com Distributed By: GMW Associates 955 Industrial Road, San Carlos, CA, 94070 USA PHONE: +1 650-802-8292 FAX: +1 650-802-8298 EMAIL: sales@gmw.com WEB: www.gmw.com

Contents 1. Basic operation... 3 2. What are the advantages of the LFR Rogowski current probes for current sensing in power measurements?... 4 3. Frequency response... 5 3.1 Amplitude response 0.01Hz to 10Hz... 5 3.2 Phase response 10Hz to 1kHz... 5 3.3 Amplitude response above 100kHz for two different coil lengths... 6 3.4 Phase response 10kHz to 100kHz... 6 4. Accuracy... 7 4.1 Accuracy with current magnitude linearity, internally generated noise and dc offset... 7 4.2 Positional Accuracy... 9 4.3 Rejecting external currents... 10 4.4 Voltage interference... 11 Figures Figure 1. Basic Operation... 3 Figure 2. LFR Low frequency (-3dB) bandwidth... 5 Figure 3. LFR Phase response 10Hz to 1kHz bandwidth... 5 Figure 4. A comparison of the amplitude response > 10kHz of LFR 03/3 with a 300mm coil and a 700mm coil.. 6 Figure 5. A comparison of phase response 10k to 100kHz the LFR03/3 with a 300mm coil and a 700mm coil.... 6 Figure 6. Linearity of the LFR03/3 with 300mm coil... 7 Figure 7. Noise on 10mV/A (600A peak range) LFR03/3... 8 Figure 8. Positional accuracy variation... 9 Figure 9. Percentage of external current measured by the LFR... 10 2

1. Basic operation The LFR is an ac current sensor. It comprises of a thin, flexible, clip-around sense coil (a Rogowski coil), which is connected to an electronic integrator housed in a small electronics enclosure. The voltage induced in a Rogowski coil is proportional to the rate of change of current enclosed by the coilloop. It is therefore necessary to integrate the Rogowski coil voltage in order to produce a voltage proportional to the current. Figure 1. Basic Operation The coil is uniformly wound with N turns/m on a non-magnetic former of constant cross sectional area A m 2. If formed into a closed loop then the voltage e induced in the coil is given by the equation: e = o NA di/dt = H di/dt where H (Vs/A) is the coil sensitivity and I is the current to be measured passing through the loop. The loop does not need to be circular and e is independent of the current position in the loop. To reproduce the current waveform as a measurement signal which can be displayed on an oscilloscope or quantified using a DVM, all that is required is a means for accurately integrating the coil voltage, such that: V out = (1/T i ) e.dt = R SH.I where T i =R o C 1 and R sh =H/T i is the transducer sensitivity in (V/A). 3

2. What are the advantages of the LFR Rogowski current probes for current sensing in power measurements? Like a current transformer (CT), the LFR does not measure the direct current component, only the alternating components. However unlike CTs, the LFR sensors: have a very wide-bandwidth have a small, known, phase error, for power measurements at 45/65Hz and above. Ideal for power measurement or power quality monitoring. do not suffer from magnetic saturation so are very linear the size of the Rogowski coil can be chosen independently of the current magnitude. This is unlike other current transducers which become bulkier as the current magnitude increases. For currents of several ka's or more there is really no better alternative than the Rogowski transducer! are very easy to use - the coil is thin, flexible and easy to insert around a current carrying device. can take large current overloads without damage can measure AC signals superimposed on large DC. The transducer does not measure direct currents - as a result it can measure small AC currents in the presence of a large DC component. provide an isolated measurement at ground potential similar to other current transducers (except coaxial shunts) i.e. there is no direct electrical connection to the main circuit. are intrinsically safe devices. There is no danger of an open circuit secondary. 4

3. Frequency response The LFR has a wide-bandwidth and is optimised to give a flat sensitivity (V/A) and small phase error over a very wide range of frequencies. At low frequencies < 1kHz the phase error of the sensor is determined principally by high stability passive components. Hence any phase error is very predictable. At higher frequency > 10kHz the phase error is determined by the dynamics of the Rogowski coil, the connecting cable and the electronic integrator which are carefully controlled to provide a predictable frequency response. Longer Rogowski coils give a larger phase error and have a lower high frequency (-3dB). 3.1 Amplitude response 0.01Hz to 10Hz Figure 2. LFR Low frequency (-3dB) bandwidth 3.2 Phase response 10Hz to 1kHz The phase error is controlled to ±10% of the nominal value shown in the bode plot below. Figure 3. LFR Phase response 10Hz to 1kHz bandwidth 5

3.3 Amplitude response above 100kHz for two different coil lengths Figure 4. A comparison of the amplitude response > 10kHz of LFR 03/3 with a 300mm coil and a 700mm coil. 3.4 Phase response 10kHz to 100kHz Figure 5. A comparison of phase response 10k to 100kHz the LFR03/3 with a 300mm coil and a 700mm coil. PEM have an accurate models of the high frequency performance of the LFR for all possible combinations of coil and cable length and can provide a frequency response or phase error calculation as necessary. 6

4. Accuracy 4.1 Accuracy with current magnitude linearity and internally generated noise Linearity error is the difference I between the true current value, I,and the measured value V out / R SH (where R SH is the sensitivity in V/A). For a fixed frequency and fixed current position the linearity error will vary with the current magnitude over the rated current of the Rogowski current probe. Rogowski current transducers contain no magnetic materials. Therefore there are no saturation or non-linear effects associated with the magnitude of the current. Additionally the integrator gain is set by highly stable low drift passive components which ensure excellent linearity. As an example, linearity was measured by varying a sinusoidal current source such that the LFR03/3 measured from peak current to around 5% of full scale and the results are tabulated in Figure 6. below. Figure 6. Linearity of the LFR03/3 with 300mm coil The comparative measurement device is a current transformer, having a traceable UKAS calibration certificate across the current range. The measurements are compared on a Keithley model 2000 DMM, having a traceable UKAS calibration certificate. The number of ampere turns through the Rogowski coil and through the current transformer is arranged such that the DMM is used only to compare two substantially equal voltages. Thus the accuracy of the DMM is not relevant. Taking into account the specified uncertainty and the typical calibration drift over one year, the estimated uncertainty for the calibrated sensitivity (V/A) of the current transformer is ±0.1%. From the results in the scatter graph of the linearity was found to be better than ±0.05% of full scale quoted on the shortform datasheets. The linearity is almost certainly better than this since the accuracy of measuring the current is of the same order as the differences. 7

The factors that can affect the linearity of the LFR 03/3 include: Low Frequency Noise The integrator op-amp generates random low frequency noise (often called 1/f noise). This noise is distributed around the low frequency bandwidth f L where the integrator gain is at a maximum. The magnitude of this noise is proportional to 1/f L H where H is the coil sensitivity in (Vs/A). An example of low frequency noise is shown below. Figure 7. Noise on 10mV/A (600A peak range) LFR03/3 Peak to peak value is 6.1mV corresponding to an rms value of 1.0mV DC Offset The output from the electronic integrator is decoupled into a buffer amplifier. The mean output should ideally be zero but in practice there is a very small DC offset. The maximum DC offset at the output of the LFR is ±2.5mV 8

4.2 Positional Accuracy Due to small variations in the winding density and coil cross sectional area the transducer output varies slightly depending on the position of the current in the Rogowski coil and also the size of the current conductor relative to the coil. PEM have developed an accurate method of manufacturing Rogowski coils which keeps this positional variation to a minimum. To quantify this variation tests were performed with two different coil circumferences, 300mm and 700mm, and two different conductor diameters 10mm and 50mm, the results are shown in Figure 8Error! Reference source not found.. Where the Tables mention 700mm (x2) the Rogowski coil was wrapped twice around the conductor. The LFR is calibrated with the conductor central in the coil, position 1, to an accuracy of ±0.3%. The values listed in the tables are an additional uncertainty due to the conductor position. The results are all worst case of the total batch of six coils tested. Positional error % of reading -10mm conductor Coil length (mm) Touching the edge of the coil Ferrule 3cm from ferrule 2 3 4 5 6 300 ±1 ±1 ±1-3.5-0.75 700 ±1.5 ±2.0 ±2.0-3.5-1 700 (x2) ±0.5 ±0.5 ±0.5-1.5-0.5 Positional error % of reading 50mm conductor Coil length (mm) Touching the edge of the coil Ferrule 2 3 4 5 300 ±0.5 ±0.5 ±0.5-0.5 700 ±1 ±1 ±1-1 700 (x2) ±0.3 ±0.3 ±0.3-0.3 Figure 8. Positional accuracy variation The results can be summarised as follows: For both coil lengths the variation of accuracy with conductor position improves as the size of the conductor increases relative to the Rogowski coil area. The positional variation is always at its worst where the coil clips together, every effort must be made to keep the conductor away from this area. Wrapping the Rogowski coil twice around a given conductor greatly improves the positional variation (i.e. comparing the 300mm and the 700mm (x2) results). However it should be noted that wrapping the coil twice around the conductor also halves the rated current and doubles the sensitivity (V/A). From these results we derive the typical accuracy of ±1% of reading quoted on the short-form datasheet. 9

4.3 Rejecting external currents Currents external to the Rogowski coil can cause measurement interference. Positional error % of reading Coil length Touching the edge of the coil Ferrule Touching the coil (mm) 2 ext 3 ext 4 ext 5 ext Y-plane Z-Plane 700 ±1.5 ±2 ±2-3.5 ±1 ±1 Figure 9. Percentage of external current measured by the LFR Figure 9. shows similar conductor positions to those shown in Figure 8, adjacent to the coil edge but this time outside the Rogowski loop. All the tests in Figure 9. were carried out using the 10mm conductor and the 700mm coil and there is a very similar error of reading to those specified in equivalent positions in Error! Reference source not found.. This is worst case; a 10mm conductor represents only 2% of the Rogowski coil area (point source of current). The LFR will often be installed in areas where conductors external to the Rogowski coil are in alternate planes to those shown in Figure 9. The LFR coil has a cancellation loop which greatly reduces its susceptibility to these currents keeping the external pick-up to typically ±1% in the Y and Z plane positions shown. If the external current (outside the coil loop) is much greater than the current being measured (inside the coil loop) then the error may be significant. This is particularly relevant if the external current is flowing in a nearby multi-turn coil. 10

4.4 Voltage interference Rogowski coils are susceptible to voltage pick-up through capacitive coupling onto the Rogowski coil winding. For a given Rogowski coil this pick-up gets worse as the rated current of the unit decreases and the sensitivity (V/A) increases. PEM has published significant research into resolving this problem. The LFR range of Rogowski coils has been optimised to attenuate any voltage interference. If the voltage close to the coil is subject to high rates of change (e.g. several 100V/ s or high frequency oscillations in the MHz range) then a larger interference can occur. As a check for the effect of external voltages or currents the user should place the Rogowski coil in approximately the same position as used for measuring the desired current, but not looped around the desired current. Ideally there should be no measured signal. If there is interference then the same interference will be superimposed on the current waveform when it is measured and this can be taken into account when interpreting the measurement. 11