SPECIFICATION OUTLINE

Similar documents
SPECIFICATION OUTLINE

SPECIFICATION OUTLINE

TECHNICAL PRODUCT DATASHEET

TTRM MHZ 16W BI-DIRECTIONAL AMPLIFIER

TTRM1004-D MHZ 25W BI-DIRECTIONAL AMPLIFIER

TTRM MHZ 20W BI- DIRECTIONAL AMPLIFIER

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

TTRM MHZ 100W BI-DIRECTIONAL AMPLIFIER

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

TB65 65W Single Output Test and Measurement/Industrial Series

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Series AM50E-NZ 50 Watt DC-DC Converter

OIS25. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

RSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R-78HB-0.5(L) DC/DC Converter

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R-78HB-0.5(L) R-78HB - /L. DC/DC Converter

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

Electronic timer CT-TGD.22

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

C B. Models. Models 2MOPP

Doc. EA Model Number:

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R R DC/DC Converter

P-Channel 100 V (D-S) MOSFET

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

SPECIFICATION. Online UPS 3000VA

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

P-Channel 100 V (D-S) MOSFET

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Schottky Rectifier, 16 A

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX

Power supply CP-D 24/4.2 Primary switch mode power supply

P-Channel 60-V (D-S) 175 C MOSFET

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDD.22

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

MB120S 120W Single Output Medical Series

High Voltage, Input Rectifier Diode, 10 A

L9333 QUAD LOW SIDE DRIVER

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

BH series Paddle joystick controllers

WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

75W Constant Current (700mA) LED Driver

300W Railway Single Output DC-DC Converter

DC-DC CONVERTER HFBC60-xxW/O

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Notes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix /H, high isolation voltage (3kVDC/1 second)

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

CB Scheme UL508 UL ATEX II3G

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Smart Power Relay E I...

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Packaging. nom. Output Voltage

BL series Miniature paddle joystick controllers

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

ACTUATOR LA12/LA12 PLC

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Fast Soft Recovery Rectifier Diode, 20 A

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

VNP35N07FI VNB35N07/VNV35N07

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

1800PT Series. Phase Control Thyristors (Hockey PUK Version), 1800A FEATURES TYPICAL APPLICATIONS. RoHS. Nell High Power Products.

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Power supply CP-D 24/1.3

ES-777-MV-P2_A1 03/01/10

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

MDW-45 Converter RS RS-422/485

Analog amplifier RA. RE Edition: Replaces:

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Potential Applications

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Power supply CP-D 12/2.1

PM24S/DR24S series 60W Single Output DC/DC Converter

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Dual Reversing Module

Product Specification sheet

COMPACT MEDICAL GRADE 365 W AC-DC POWER SUPPLY MFA350 SERIES

TE W Single Output External Power Test & Measurement/Industrial Series

Single phase bridge. (Power Modules), 25 A/35 A

TEST REPORT... 1 CONTENT...

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

Three-phase AC input. Suitable for 3U or 5U height mounting. Single-wire current share or Droop current share

FS10 Series AC-DC Converter Compact Case(Power tank)

Transcription:

ECO DESCRIPTION DTE BY 001 5479 PRODUCTION RELESE 10/02/2009 GF 5663 OMIT PRODUCT ND SERIL NUMBER LBEL DETIL REPLCE PPROPRITE SE REFERENCES WITH ISO REFERENCES ENHNCE REGULTORY REQUIREMENTS TBLE 5/26/2010 BF Converter 24V to 12V/ 20 mps, with Switched output PROPRIETRY THIS DRWING IS THE PROPERTY OF SURE POWER INC. and shall not be copied, reproduced, lent, or disposed of, nor used for any purpose other than that for which it is specifically provided without written permission of SURE POWER INC. UNLESS OTHERWISE SPECIFIED DIMENSIONS RE IN INCHES [MM] TOLERNCES RE:.XX ±.10 [X.X ± 2.5].XXX ±.030 [X.XX ± 0.76] INTERPRET GEOMETRIC DIMENSIONS ND TOLERNCING PER SME Y14.5-1994 DRWINGS IN THIS DOCUMENT RE NOT TO SCLE PPROVLS DTE DRWN BY MM 08/05/08 PROJECT ENG PPROVL ENG MNGER PPROVL CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. PRODUCT MNGER PPROVL SCLE: NONE FILE: - SHEET 1 OF 11

THEORY OF OPERTION The is a 20 DC to DC converter. The converter is used to provide a regulated voltage for 12V apparatus from a 24V source. The converter provides both a switched output and an unswitched output. The switched output responds to the IGNITION input. When the IGNITION input is active the switched output is enabled. The feature is primarily used when the converter is used to power a radio with memory requirements. If a switched output is not required then the unswitched output should be used, and the ignition input and switched output pins can be left unconnected. The converter is designed to withstand the severe electrical environment of heavy-duty trucks and off highway equipment. The converter can withstand load dump, reverse battery, short circuit, and over-temperature without damage to the unit. The switched output is implemented using a MOSFET transistor. Due to the MOSFET body diode the switched output should never be connected to a battery or voltage source. Protection circuits include an over voltage monitor for input voltage and over temperature monitor attached to the PCB near the internal FET s. Both monitors can shut the converter off until the corresponding out of range condition is corrected. n additional protection circuit is used to protect the system loads in the event of a fault where the output voltage increases above its regulation. The output over protection circuit (OCP) will latch the converter off. This latch can be reset by removing and reapplying the input power. CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 2 OF 11

CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 3 OF 11

FUNCTIONL DESCRIPTION Connections Connections to the unit are made via a 6 pin connector. The terminals are as follows: Deutsch connector DT13-6P Pin 1* +24V Input Voltage Input voltage to the converter. Pin 2 Ignition Switched output control lead, active high. Pin 3 Ground System ground. Pin 4 +12V Unswitched Unswitched output voltage. Pin 5 +12V Switched Switched output voltage, controlled by Pin 2 above. Pin 6 Ground System ground. DEUTSCH MTING CONNECTOR HOUSING: DT06-6S SOCKET: 0462-209-16141 LOCK: W6S * Recommend external fuse on input wiring (25 fuse minimum). CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 4 OF 11

ENVIRONMENTL SPECIFICTIONS Characteristic Parameter Unit Notes: Operational Temperature Range Storage Temperature Range -40 to +85 C See derating curve (Figure 1) below. -55 to +105 C Over-Temp Limit 105 C pproximate case temperature that activates the over-temperature protection circuit. Maximum Heatsink Temperature 100 C Heatsink temperature must be kept below this value to prevent activation of over-temperature shutdown circuit. Humidity 0 to 95 %RH SE J1455,. JUN2006, Section 4.2 Salt Spray 96 Hrs Handling Drop Will show damage STM B 117-07 and IEC 60068-2-11 Part 2, Test Ka SE J1455, Rev. JUN2006, Section 4.10.3.1 Sealing +/-35 kpa Sealed against water and water vapor. Vibration 9.26Grms, 5 Hz 2kHz MIL-STD-202G, Method 214, Fig. 214-1, Test Condition 1C Immersion 1 meter 1 meter for ½ hour. IEC 60529 Ed. 2.1, IP67 Water Ingress DIN 40050 T9, IPX9K Shock 30G, 11mS, ½ sine MIL-STD-202G, Method 213B, Conditions J Thermal Cycle -40 to +85 12 cycles C SE J1455, Rev June 2006 Sect 4.1.3.1 Fig 2B Thermal Shock -55 to +90 100 cycles C SE J1455, Rev June 2006 Sect 4.1.3.1 Fig 2C CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 5 OF 11

Figure 1 CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 6 OF 11

ELECTRICL SPECIFICTIONS MXIMUM RTINGS: Maximum ratings establish the maximum electrical rating to which the unit may be subjected without damage. Characteristic Parameter Unit Notes: Standoff Voltage 80 V pplied between pins 1 and 2 relative to pins 3 and 6. Unit must remain functional after this voltage is removed. Time at Standoff 60 min 25C Reverse Polarity -52 V Time at Reverse Polarity 1 Hr Maximum llowable load 20 This is the maximum reverse voltage that may be applied between pins 1 and 2 relative to pins 3 and 6 without permanent unit damage. Tested at 85 C per SE J1455, Section 4.11.1 Output current is the sum of the currents from the switched and unswitched outputs. CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 7 OF 11

ELECTRICL CHRCTERISTICS: Unless otherwise stated, conditions apply to full temperature range and full input voltage range. Characteristic MIN TYP MX Unit Notes: Input voltage operating range Input Over Voltage Turn OFF Input Under Voltage Turn ON 18 27.5 32 V 32 36 V 18 V Output voltage to remain within specified output range under full load. Converter will shutdown within this range and above. Converter must have this input voltage level to start up into specified maximum load. Maximum Input Current 18 Input voltage 18V, load of 20, 25C Quiescent Current 5 7 m Efficiency 88% 92% Output Voltage 13.2 13.7 14.2 V Input Voltage 24V. Current draw from the input with no load attached to either output, and ignition off. 25C. Over entire input voltage range at rated output current at 25C. Over entire input voltage range at rated output current at 25C. Output Operational Current Limit Output Short Circuit Current Limit Ignition thresholds (SW Output on) 20 22 32 18 V Sum of unswitched and switched outputs with output voltage within specified range. Input voltage 18V to 32V, output voltage less than 2 Volts. Ingintion input will sink about 6 m when greater than 15V is applied. CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 8 OF 11

ELECTROMGNETIC COMPTIBILITY Immunity to Radiated Electromagnetic Fields Bulk Current Injection (BCI) Method 30 MHZ to 18 GHz, bsorber-lined Chamber Level 180 m 100 V/m Notes: SE J1113-4, Rev. UG2004 Requirements = Class B, Region IV SE J1113-21, Rev. OCT2005 Requirements = Status 2 Conducted Immunity Level Notes 250 khz to 400 MHz Direct Injection of Radio Frequency (RF) Power 200mW SE J1113-3, Rev. SEP2006 Requirements = Status II, Level 3 Emissions Level Notes: Conducted Emissions Class 2 Radiated Emissions Class 2 SE J1113-41, Rev. MY2000 Section 5 Conducted Emissions - Component/Module SE J1113-41, Rev. MY2000 Section 7 Radiated Emissions - Component/Module Transient Immunity Test Level Notes: Inductive Switching Inductive Switching Switching Spikes Starter Motor Engagement Load Dump Class B Class B Class B Class B Class B ISO 7637-2, Ed. 2, Pulse 1 ISO 7637-2, Ed. 2, Pulse 2 & 2B ISO 7637-2, Ed. 2, Pulse 3 & 3B ISO 7637-2, Ed. 2, Pulse 4 ISO 7637-2, Ed. 2, Pulse 5 & 5B CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 9 OF 11

Electrostatic Discharge Immunity Level Notes: ESD, Powered (In Vehicle) ESD, Package and Handling ±8kV direct ±15kV air ±8kV direct ±15kV air SE J1113/13, Rev. Nov 2004 ll connections and exposed parts. SE J1113/13, Rev. Nov 2004 8kV max on pin 5 Regulatory Requirements Level Notes: Radiated Emissions Radiated Broadband and Narrowband Emissions Transient Immunity and Emissions Restriction on the use of certain Hazardous Substances in electrical and electronic equipment End of Life Vehicles Testing Methods for Hazardous Substances in Electronic Information Products EU Directive 2004/108/EC as amended, ISO 13766 and EN13309 EU Directives 72/245/EEC as amended EU Directives 72/245/EEC as amended EU Directive 2/95/EC as amended EU Directive 2/53/EC as amended People s Republic of China legislation SJ/T 11365-2006 CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 10 OF 11

MECHNICL SPECIFICTIONS CONVERTER WEIGHT: 1023-1131 grams UNIT DIMENSIONS: Inches [Millimeters] 5.750 [146.05] 5.000 [127.00] 6X.210 [5.33] 2.500 [63.50].375 [9.53] (.28 [7.1]).180 [4.57] 4.140 [105.16] 4.500 [114.30] (6X.325±.020) ([8.25±0.51]) (MOUNTING SLOTS) 2.350 [59.69] CONV,20,24/12V,RoHS CGE CODE NO. DRWING NO. SCLE: NONE FILE: - SHEET 11 OF 11