REQUEST FOR INFORMATION (RFI)

Similar documents
TECHNICAL CORRECTION October Process Industry Practices Structural. PIP STF05121 Fabrication and Installation of Anchor Bolts

PIP STF05121 Anchor Fabrication and Installation Into Concrete

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

1.1 RELATED DOCUMENTS

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

STEEL PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

PART MATERIALS. Section Fencing Materials. Description

GENERAL ELEVATION SECTION A-A

Hex Cap Screws Coarse & Fine Thread

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

OUR QUALITY POLICY VISION MISSION

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Standard Specification for Quenched and Tempered Steel Bolts and Studs 1

Letter of Transmittal/Submittal

BOLTS AND NUTS Square Bolts( Table 1 ) Hex Nuts ( Table 7 ) Heavy Hex Nuts (Table 7) Heavy Hex Structural Bolts ( Table 2 )

SECTION METAL FABRICATIONS

ODOT ITB Group 4 Item 33 Qty. 1

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Evaluation of In-Pavement Light Fixture Designs and Performance

Shearwall System Installation Guide

Balaji THE COMPANY MISSION

Midwest Roadside Safety Facility

Indian Fasteners Marketing

Standard Specification for High-Strength Bolts for Structural Steel Joints [Metric] 1

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Multi-Institutional Academic Health Science & Research Center Evansville, IN

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Procedure for Wrench Calibration and Snug Tightening

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

August 2015 Fastener Industry Technology Update from the IFI

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

AUXILIARY FRAMING AND ACCESSORIES

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

Standard Specification for Carbons and Alloy Steel Nuts 1

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

KO LO SH E LT E R. High Capacity and Flexibility

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

Section 914. JOINT AND WATERPROOFING MATERIALS

Steel Casework Metal Framing System

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Large Diameter Tapcon

OFFICE OF MANAGEMENT AND FINANCE

FURNITURE LABORATORY METAL FRAMING SYSTEM. For additional information and help in planning contact Mott Manufacturing.

Khathij Industrial Fasteners

INSTRUMENT MOUNTING STANDS PRODUCT CATALOG Continuous Tray Support System for Instrumentation and Controls

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

COMMERCIAL ITEM DESCRIPTION RODS, GROUND (WITH ATTACHMENTS)

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

Midwest Roadside Safety Facility

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

Umbrella Inserts and Stubby Screens

CONCRETE ACCESSORIES BAR-LOCK REBAR COUPLER SYSTEM

Installation Instructions

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

THE WORLD LEADER.

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

DBP Technical Data Series Rev. 0 Jan. 1, Pre Assembled Door Canopies

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

SUBMITTAL INFORMATION "BOLTS, NUTS AND FLAT WASHERS" "ABSTRACT OF ASTM A307 GRADE A AND B" CARBON STEEL BOLTS AND STUDS, 60,000 PSI TENSILE STRENGTH

Product Guide Specification

OSE Submittal July 20, 2018

B " 787

Project: # Solano Community College District

Designation: F

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

Chemical composition. Type 2 as per F568: C ( ); P (max 0.048); S (max 0.058); Mn (min 0.74); B (min );

THE WORLD LEADER.

Load Tables, Technical Data and Installation Instructions

KEEP YOUR RESOURCE MOVING.

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

ICC-ES Evaluation Report

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

STRATUS SHELTER. Take bike parking to new heights

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Midwest Roadside Safety Facility

STRUCTURAL ATTACHMENTS

PRODUCT DATA CATALOG

SECTION TRAFFIC SIGNAGE

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Design and Construction Standards SECTION ATHLETIC LOCKERS

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

TAPTITE 2000 HEAT TREATMENT. Increased out of round of point threads. Low thread forming torque

Swerve Rack CUSTOM RACKS AVAILABLE

Transcription:

Planning, Development & Facilities 349 Magnolia Avenue Glendale, California 91204 Tel: 818.507.0201 Fax: 818.507.4911 Project Name: Jefferson ES-12 Classroom Bldg. DSA No: A#:03-114361, File#:19-41 District PO No: District Contract No: 113-15/16 REQUEST FOR INFORMATION (RFI) To: Armond Mailan From:Chalmers Construction Services Inc. Required by: Ara Baghdasarians RFI No. 076 Date: 12/12/16 Answered: REFERENCE: Drawing(s) - Specification(s) Page(s) CONTRACTOR S REQUEST: As the installed anchor bolts on grid line 2 ( Between gridlines B-E ) are +/- 1" lower than proposed elevation so It will not be enough threads out for anchor bolts after installing the washers and nuts. Same situation for few other base plate's anchors on different locations which It will not be enough threads out after installing the washer and nut. ( Please Advice ) Based on this also the 2" indicated non-shrink grout underneath the base plate will be 3". ( PLease confirm ) **See attached pictures** PROPOSED SOLUTIS: As the material of steel is same for both achor bolts and base plates so it is suggested to eliminates the nut and just use the 1" washer plate including the weld all around the washer and on top of it. DISTRICT REPRESENTATIVE S ADDITIONAL INFORMATION: ARCHITECT S RESPONSE: *This response was provided FOR INFORMATION ONLY with no effect to the contract. *This response is a CLARIFICATION of the contract. (NO COST or TIME EFFECT) *This response is a MINOR CHANGE to the contract with no effect to the contract cost or time. (NO COST or TIME EFFECT) **This response CHANGES the contract with an anticipated effect to contract cost and/or time. (COST/TIME EFFECT) The Contractor is to prepare a Change Order Proposal before proceeding. * This does not modify contract cost or time. If the recipient believes that the RFI has any effect on contract cost and/or time, the recipient shall respond in writing in accordance with Contract provisions.

RFI#076 response from NAC 01/09/2017 January 09, 2017 Issued as response attachment to RFI #76 Re: GUSD Jefferson ES ORG response to RFI #76 DSA A#03-114361 Architect s Response to RFI #076 DSA has approved the submitted CCD#0 which is now attached to the response to RFI#076. The CCD#0 addresses the grout and anchor bolt issues, but additional documentation for clarity has been provided as noted below. Testing shall be coordinated with the project Testing Lab and in keeping with Section #4 of DSA IR 17-8 (issued by DSA on 01-12-11). Below is from email of 12/23/2016, from Brad Brewer, NAC RFI#76: Low anchor bolts and grouting and shear lug o Chalmers confirmed that they will utilize we will use Sika 328 for locations that the grout thickness is more than 2 o Chalmers confirmed the coupler nut solution is preferred, and steel fabricator provided recommendation of coupler model number. Please confirm coupler meets ATSM parameters set in the DSA Approved CCD#0 (cut sheet documents for coupler provided by Chalmers are included in RFI#076 reference materials of response) o Chalmers confirmed that the Steel Fabricator has enough tolerance, in keeping with the Contract Documents, to account for anchor bolts that are 1/8 short. (email from Chalmers is provide by Chalmers are included in RFI#076 reference materials of response) NAC Response to RFI#076, as coordinated with KPFF Structural and discussed with GUSD, BPI and Chalmers. \\nac\0\it\nac-forms\2016-form-updates\don potts\new forms\word\general\letterhead.docx >837 North Spring Street, Third Floor, Los Angeles, CA 90012 327075 / nacarchitecture.com Seattle / Spokane / Los Angeles

RFI#076 response from NAC 01/09/2017 26 APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun

RFI#076 response from NAC 01/09/2017 8 APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun 12-28-2016 CCD-A0 CCD-0A 8 8 <AS REVISED>

RFI#076 response from NAC 01/09/2017 APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun 12-28-2016 CCD-A0 CCD-0A 8 <AS REVISED>

RFI#076 response from NAC 01/09/2017 8 8 APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun <AS REVISED> 12-28-2016 CCD-0A CCD-A0

RFI#076 response from NAC 01/09/2017 1 1/2" MIN 6" MIN TO 8" MAX EMBED 2" MIN TO 4" MAX 009 ROD COUPLER WHERE TOP OF THREADED ROD HAS LESS THAN 0" OF PROJECTION THROUGH NUT AT TOP OF BASE PLATE 008 NTS APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun DSA FILE NUMBER: 19 41 DSA APPLICATION NUMBER: 03 114363 PROJECT NAME: Jefferson ES ORG NEW DETAIL DATE: 12.28.2016 CCD-A0 008 REFERENCE DRAWING 1/S6

RFI#076 response from NAC 01/09/2017 ASTM A354 GRADE BD THREADED ROD TO MATCH DIA OF SHORT ROD BELOW BRACED FRAME BASE PLATE EQ NON SHRINK HI STRENGTH GROUT T.O. FOUNDATION PER PLAN ASTM A563 DH COUPLING NUT APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun 2" MIN, 3" MAX EQ 1" MAX TYP SHORT ASTM A354 GRADE BD ANCHOR ROD PER 1/S618 CHIP OUT AND SOLID GROUT NOTES: 1. SEE 1/S618 FOR BALANCE OF INFORMATION NOT SHOWN. BRACED FRAME BASE ANCHOR ROD EXTENSION DSA FILE NUMBER: 19 41 DSA APPLICATION NUMBER: 03 114363 PROJECT NAME: Jefferson ES ORG NEW DETAIL DATE: 12.28.2016 CCD-A0 009 REFERENCE DRAWING 2/S618

RFI#076 response from NAC 01/09/2017 ASTM A36 ALL THREAD ROD TO MATCH DIA OF HEX HEAD ANCHOR BOLT BELOW COLUMN BASE PLATE EQ NON SHRINK HI STRENGTH GROUT T.O. FOUNDATION PER PLAN ASTM A563 A COUPLING NUT APPROVED DIV. OF THE STATE ARCHITECT LOS DIV. ANGELES OF THE REGIONAL STATE ARCHITECT OFFICE LOS ANGELES REGIONAL OFFICE DATE SS 01/05/2017 FLS AC DATE lzeitoun 2" MIN, 3" MAX EQ 1" MAX TYP SHORT ASTM A307 HEX HEAD ANCHOR BOLT PER 5/S600 CHIP OUT AND SOLID GROUT NOTES: 1. SEE 5/S600 FOR BALANCE OF INFORMATION NOT SHOWN. GRAVITY COLUMN BASE ANCHOR ROD EXTENSION DSA FILE NUMBER: 19 41 DSA APPLICATION NUMBER: 03 114363 PROJECT NAME: Jefferson ES ORG NEW DETAIL DATE: 12.28.2016 CCD-A0 0 REFERENCE DRAWING 5/S600

RFI#076 Initial Reference Materials/photos: Provided by Chalmers with initial RFI #076 Coversheet

RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 From: To: Cc: Subject: Date: Attachments: Ara Baghdasarian Bradford Brewer manuel@chalmerscs.com Anchor bolts Wednesday, December 14, 2016 1:36:46 PM IMG_0749-14-12-16-09-07.png Hello Brad, Please disregard anchors that are low 1/8. After we sent you previous email, I talked to steel sub and he told me that he has enough tolerance to adjust the 1/8. So top of nut will be flush with anchor. Three steel plates on Grid line 2 are the ones that needed to be fix. Thank you, Sincerely, Ara Baghdasarian Chalmers Construction Services Inc 2600 Foothill Blvd. Suite 304 La Crescenta CA 91214 Office 818-957-4521 Fax 818-957-4223 Cell 818-220-2641

Nut Compatibility Chart - Portland Bolt RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 12/20/16, 2(38 PM (800) 547-6758 sales@portlandbolt.com Nut Compatibility Chart A563 Grade and ANSI Nut Style Grade of Bolt Surface Finish Nominal Size Inches Recommended Suitable A307 Grade A & C A307 Grade B Any Any Hex Heavy Hex Hex Heavy Hex to 1 A B,D,DH A,B,C,D,DH,DH3 >1 to 2 A A C,D,DH,DH3 >2 to 4 A C,D,DH,DH3 to 1 A B,D,DH A,B,C,D,DH,DH3 >1 to 2 A A >2 to 4 A A325 Type 1 Plain - 1 C C3,D,DH,DH3 Galvanized - 1 DH A325 Type 3 Plain - 1 C3 DH3 A354 Grade BC A354 Grade BD A449 Plain Galvanized Plain Plain Galvanized to 1 C D,DH C3,D,DH,DH3 >1 to 4 C C3,D,DH,DH3 to 1 DH >1 to 4 DH to 1 DH DH D,DH,DH3 >1 to 4 DH DH3 to 1 B D,DH B,C,C3,D,DH,DH3 >1 to 3 A C,C3,D,DH,DH3 to 1 DH D,DH D >1 to 3 DH D A490 Type 1 Plain - 1 DH DH3 A490 Type 3 Plain - 1 DH3 A687 Plain - 3 D DH,DH3 Galvanized - 3 DH to 1 A B,D,DH A,B,C,D,DH,DH3 http://www.portlandbolt.com/technical/nut-compatibility-chart/ Page 1 of 2

Nut Compatibility Chart - Portland Bolt RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 12/20/16, 2(38 PM F1554 Grade 36 Any >1 to 4 A C,D,DH,DH3 F1554 Grade 55 Plain to 1 A B,D,DH A,B,C,D,DH,DH3 >1 to 4 A C,D,DH,DH3 Galvanized to 4 A C,D,DH,DH3 F1554 Grade 5 Plain to 1 D DH,DH3 >1 to 3 DH DH3 Galvanized to 3 DH DH3 1. The availability of A563 grade DH nuts in nominal sizes 3/4 and larger is very limited and generally available only on special orders of 50,000 or more. For smaller quantities, ASTM A194 grade 2H should be considered. ASTM A194 Nut Compatibility Chart Grade of Bolt A194 Heavy Hex Nut Grade A193 Grade B7 2H or 4 or 7 A193 Grade B8 (Class 1 and 2) 8 A193 Grade B8M (Class 1 and 2) 8M A320 Grade L7 4 or 7 A320 Grade B8 (Class 1 and 2) 8 A320 Grade B8M (Class 1 and 2) 8M For Class 2 stainless steel grades, strain hardened nuts available as a supplementary requirement http://www.portlandbolt.com/technical/nut-compatibility-chart/ Page 2 of 2

Hex Coupling Nuts - Portland Bolt RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 12/20/16, 2(38 PM (800) 547-6758 sales@portlandbolt.com Hex Coupling Nuts A194 A563 F594 Hex couplers are used to connect two pieces of threaded material. Hex and heavy hex couplers are threaded right hand. If a right hand-left hand coupler is needed, consider using a sleeve nut. Related Products Sleeve Nuts Turnbuckles Washers See our nut compatibility chart to determine the compatible hex coupler for a specific grade of bolt. Since hot-dip galvanizing typically adds 2.2 to 5 mils of thickness to the threaded portion of a fastener, galvanized couplers are tapped oversize to compensate for the corrosion resistant coating on the bolts. Stock Diameters: 1/2 1 Origin: Domestic and import Finish: Plain and hot-dip galvanized Grades: A563 (grades A and DH) Related Links Coupling Nut Thread Engagement Galvanized Nuts Tapped Oversize Coupling Nut Grades Available Diameters: 1/2 6 Origin: Domestic and import Finish: Plain and hot-dip galvanized Grades: A563 (grades A, C, and DH), A194 grade 2H Dimensions Finished Hex Coupler Pattern F C H Part Numbers Size Width Width Across Across Flats Corners Bas Max Min Max Min ic Ba sic Nominal Length/Thickness Import Max Min Plain Galvanized http://www.portlandbolt.com/products/nuts/hex-coupling/ Page 1 of 3

Hex Coupling Nuts - Portland Bolt RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 12/20/16, 2(38 PM 11 16 0.688 0.663 0.794 0.756 1 1.760 1.690 12338 17525 13 16 1 8 0.813 0.782 0.939 0.89 2.135 2.067 12559 18195 1 1.000 0.963 1.155 1.097 2 2.260 2.190 12557 17526 7 8 1 1.250 1.212 1.443 1.382 2 2.5 2.440 12558 19504 1 1 1.375 1.325 1.588 1.51 2.760 2.690-18494 1 8 1 1 1.500 1.450 1.732 1.653 3 3.0 2.940 18394-3 8 1 1 1.625 1.575 1.876 1.825 3 3.0 2.940 18994 17529 1 2 2.000 1.950 2.309 2.275 3 3.5 3.440 - - Dimensions per ASME B18.2.2 20 Some dimensions may vary by supplier Heavy Hex Coupler Pattern F C H Part Numbers Nomi nal Size Width Across Basi c Flats Width Across Corners Max Min Max Min Basi c Thickness A563DH Domestic Max Min Plain Galvanized 7 8 0.875 0.850 1.0 0.969 1 - - - - 1 16 7 8 1 1.062 1.031 1.227 1.175 1 - - 17543 17544 1 1.250 1.212 1.443 1.382 2 - - - 17527 7 8 7 16 1 1.438 1.394 1.660 1.589 2 - - - - 1 1 1.625 1.575 1.876 1.796 3 - - - 12343 1 8 13 16 3 8 1 1 1.812 1.756 2.093 2.002 3 - - - - 1 2 2.000 1.938 2.309 2.209 3 - - 17547 17548 3 8 1 2 2.375 2.300 2.742 2.622 4 - - 17551 17552 9 16 7 8 1 2 2.562 2.48.959 2.828 4 4.9.83 - - 1 2 2.750 2.662 3.175 3.035 5 5.29 5.21 17553 17554 7 8 15 16 1 2 2.938 2.844 3.392 3.242 5 5.67 5.58 - - 1 8 2 3 3.125 3.025 3.608 3.449 6 6.04 5.95 17555 17556 2 3 3.500 3.388 4.041 3.862 6 6.80 6.70 - - 7 8 2 3 3.875 3.750 4.474 4.275 7 7.55 7.44 - - 2 4 4.250 4.112 4.907 4.688 8 8.31 8.19 - - 4.625 4.475 5.340 5.2 9 9.06 8.94 - - http://www.portlandbolt.com/products/nuts/hex-coupling/ Page 2 of 3

Hex Coupling Nuts - Portland Bolt RFI#076 Reference Materials: Provided by Chalmers via email 12/14/2016 12/20/16, 2(38 PM 3 5 5.000 4.838 5.774 5.515 9 9.81 9.68 - - 3 8 3 5 5.375 5.200 6.207 5.928.57.43 - - 3 5 5.750 5.562 6.640 6.341 11 11.32 11.17 - - 1 8 4 6 6.125 5.925 7.073 6.755 12 12.08 11.92 - - 7 8 4 6 6.875 6.650 7.939 7.581 13 - - - - 5 7 7.625 7.37.80.408 15 - - - - Heavy coupler dimensions are not defined by ASME 18.2.2. The width across the flats and corners match the dimensions of a heavy hex nut. http://www.portlandbolt.com/products/nuts/hex-coupling/ Page 3 of 3

RFI#076 Reference Materials: Anchor Bolt Dimension Shy of Being Flush Provided by Chalmers via email 12/14/2016

RFI#076 Reference Materials: Grout Thicknesses Exhibit, Provided by Chalmers via email 12/15/2016 RFI#076 Reference Materials: Grout Thicknesses Exhibit, Provided by Chalmers via email 12/15/2016