Grounding & EMC : Status and Plans Belle II Focused Review

Similar documents
EMC review for Belle II (Grounding & shielding plans) PXD DEPFET system

Detector noise susceptibility issues for the future generation of High Energy Physics Experiments

EMC Immunity studies for front-end electronics in high-energy physics experiments

Verifying Simulation Results with Measurements. Scott Piper General Motors

Overview of the ATLAS Electromagnetic Compatibility Policy

Tracking Detectors for Belle II. Tomoko Iwashita(Kavli IPMU (WPI)) Beauty 2014

Lecture 11. Complex Detector Systems

EMI Filter Design and Stability Assessment of DC Voltage Distribution based on Switching Converters.

EMC Phenomena in HEP Detectors: Prevention and Cost Savings

Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4. Final design and pre-production.

Immunity Testing for the CE Mark

Particle identification at Belle-II

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

10 Safety earthing/grounding does not help EMC at RF

Unleash SiC MOSFETs Extract the Best Performance

Common Impedance Coupling Effect on Video and Audio Circuitry. Prof. Bogdan Adamczyk Grand Valley State University

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Electromagnetic Compatibility

Grounding, Shielding and Power Distribution in LHCb

The Detector at the CEPC: Calorimeters

R & D for Aerogel RICH

The 1st Result of Global Commissioning of the ATALS Endcap Muon Trigger System in ATLAS Cavern

EMC of Power Converters

BaBar and PEP II. Physics

Relationship Between Signal Integrity and EMC

Topologies for Optimizing Efficiency, EMC and Time to Market

Determining The Size Of Cabinet Apertures For Effectively Mitigating Radiated Emissions. By David Norte Thursday, April 7 th, 2005

Design for Guaranteed EMC Compliance

75W Constant Current (700mA) LED Driver

Motivation Overview Grounding & Shielding L1 Trigger System Diagrams Front-End Electronics Modules

Differential Amplifiers

EMC Testing to Achieve Functional Safety

SLAC-LLNL ILC Damping Ring Kicker High Availability Modulator R&D Program

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

Applications of 3D Electromagnetic Modeling in Magnetic Recording: ESD and Signal Integrity

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling

CALICE AHCAL overview

Facility Grounding & Bonding Based on the EMC/PI/SI Model for a High Speed PCB/Cabinet

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Semiconductor Detector Systems

Pixel hybrid photon detectors

Introduction to Electromagnetic Compatibility

EMC Simulation of Consumer Electronic Devices

2620 Modular Measurement and Control System

EMI AND BEL MAGNETIC ICM

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

3.7 Grounding Design for EAST Superconducting Tokamak

Class-D Audio Power Amplifiers: PCB Layout For Audio Quality, EMC & Thermal Success (Home Entertainment Devices)

Status of the LHCb Experiment

Common myths, fallacies and misconceptions in Electromagnetic Compatibility and their correction.

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

INTRODUCTION TO CONDUCTED EMISSION

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

EMC Near-field Probes + Wideband Amplifier

50W Constant Current (700mA) Dimming LED Driver

Test of Signal Transmission for a GERDA string

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

11 Myths of EMI/EMC ORBEL.COM. Exploring common misconceptions and clarifying them. MYTH #1: EMI/EMC is black magic.

Plans for RPC DHCAL Prototype. David Underwood Argonne National Laboratory

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

Designing external cabling for low EMI radiation A similar article was published in the December, 2004 issue of Planet Analog.

Spectrometer cavern background

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Electromagnetic Compatibility of Power Converters

Reminder on the TOB electronics architecture Test of the first SS rod prototype

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Modeling and Simulation of Powertrains for Electric and Hybrid Vehicles

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

Solving Electromagnetic Interference (EMI) with Ferrites

Max. Output Power. Efficiency (1) 110Vac 220Vac

Max. Output Power. Typical Efficiency (2) 24 Vdc 176 ~ 305 Vac 0~20.83 A 500 W 93.5% EBV-500S024SV

Development and Test of a Demonstrator for a First-Level Muon Trigger based on the Precision Drift Tube Chambers for ATLAS at HL-LHC

Common myths, fallacies and misconceptions in Electromagnetic Compatibility and their correction.

CHAPTER 2 EQUIVALENT CIRCUIT MODELING OF CONDUCTED EMI BASED ON NOISE SOURCES AND IMPEDANCES

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

Intra-system EMI hardening for increased machine reliability. Ray Brett.

Production of HPDs for the LHCb RICH Detectors

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

Balanced Constant Current Excitation for RTD Sensor Measurements

SELECTION GUIDE. Nominal Input Voltage Output Voltage. Output Current

Overall Design Considerations for a Detector System at HIEPA

Max. Output Power. Efficiency (1) 110Vac 220Vac

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

MER1 Series 1kVDC Isolated 1W Single Output DC/DC Converters

PC Krause and Associates, Inc.

Designing Your EMI Filter

EMC output filter recommendations for MA120XX(P)

ITk silicon strips detector test beam at DESY

HEC-30/35LTA-33TDAA Rev A

HEC-35LTA-XXTSAA Rev A

FLTR100V10 Filter Module 75 Vdc Input Maximum, 10 A Maximum

How EMxpert Diagnoses Board-Level EMC Design Issues

Chapter 12 Digital Circuit Radiation. Electromagnetic Compatibility Engineering. by Henry W. Ott

Transcription:

Grounding & EMC : Status and Plans Dr. F. Arteche Instituto Tecnológico de Aragon (ITA) Max Planck Institute für Physik (MPI) On behalf of Belle II EMC (Grounding) working group

Outline 1.Introduction 2. GND & EMC strategy 3.Grounding issues 4.Cabling issues 5.EMC issues 6.Future plans 7.Conclusions 1 de 28

1. Introduction During last one and a half years a lot of activities have been carried out in order to ensure the correct integration of Belle II electronics. A working group has been created to coordinate this activities Grounding & EMC working group We usually meet during Belle II general meetings in order to coordinate and follow up these activities. 1 st meeting Nov 2011 2 nd meeting Jul 2012 3 rd meeting March 2013 4 th Meeting - July 2013 They have been very good and useful meetings All sub-detectors have participated 2 de 28

1. Introduction During the last meeting we have organized a review of the grounding and EMC activities in order to verify Grounding topologies - Belle II grounding policy Cable layout Cable Installation EMC plans - Control noise issues The review committee was created with Belle II members and external reviewers (EMC experts) Manobu Tanaka C.Rivetta G.Varner H.G. Moser / C.Kiesling C. Irmler / K. Hara Suji Uno Many thanks to all of them S. Korpar I.Adachi A. Kuzmin P.Pakhlov/L.Pillonen Yutaka Ushiroda F.Arteche 3 de 28

1. Introduction The review was a very good overview of sub detectors activities on these topics. We have made a lot of progress since first meeting Big effort from everybody It has helped us to detect first incompatibilities before installation and commissioning. This is only one more step to full system integration The discussion has only started... The review committee has prepared a report with the most important issues of the meeting During the next slides I will summarize: Grounding and EMC activities. Main topics and conclusions from this review 4 de 28

2. GND & EMC strategy CsI EM calorimeter (ECL) RPC μ & K L counter: scintillator + Si-PM (for end-caps) (eklm-bklm) Solenoid SVD (Silicon Vertex Detector) PXD (DEPFET), Central Drift Chamber (CDC) PI barrel / PI Endcap TOP+A-RICH 5 de 28

2. GND & EMC strategy The main goal of Grounding & EMC integration strategy is to ensure the correct performance of Belle II experiment. Ensure the compatibility in each sub-system Ensure the compatibility among units sub-systems It establishes a safety margin EMC integration strategy has three parts: Grounding issues Cabling issues EMC issues Compatibility Compatibility Compatibility SUB1 SUB2 6 de 28

3. Grounding What is a ground? It is a reference : Uniform reference voltage at any frequency It is a structure to bypass currents Fault (short circuits..) Noise Reasons for Grounding Safety Equipment protection Equipment performance Golden rule: Make the system safe and then make it work Several recommendations were made. 7 de 28

3.1 Grounding Topologies Most of the grounding topologies has been presented Multipoint ground Floating PS units (LV) It is time to define a common topology for all subdetectors First hot areas have arisen Grounded vs Floating (FEE) Performance vs Safety (HV) Safety issues have become a priority concern Belle II electrical safety requirements KEK electrical safety rules (Coordination) They may have an impact on the design 8 de 28

3.1 Grounding Topologies PXD Multipoint GND using cooling blocks LV floating power supply DC-DC converters Multipoint GND at DOCK box DOCK connected to CDC (detector structure) Isolated LV DC-DC Non Isolated HV Gnd via resistors FDAC Differential Transmi. SVD 9 de 28

3.1 Grounding Topologies Multipoint GND Isolated LV Non-isolated HV 100/200 ohms common ground at FEE LV shields connected locally ARICH TOP Plan to ground at the detector side support structure LV, HV, Bias, DAQ cables connected to the detector Signal processing done at the front-end board shielded. Pick-up noise not observed 10 de 28

3.1 Grounding Topologies bklm Grounding topology Single-point at each detector module (multipoint) Grounding connections AC ground at detector, DC ground at readout crate; HV DC ground at power supply It is planned to use the same gnd scheme as for Belle. (good results) No connect: Mech.structure - FE board Connection: FE amp gnd frame Shield connected 1s 11 de 28 ECL

3.1 Grounding Topologies CDC It proposes an isolation ground philosophy. It required to be separated from Belle- II structure, BPID, SVD and others. Signal ground connected to: The backward end plate in the CDC Through the power modules in the electronics hut. High voltage ground may be disconnected from the forward end plate. Grounding topology still open Some test set-up are ready for noise measurements: They plan to study several ground topologies. 12 de 28 eklm

3.2 Grounding summary The sub-detectors have presented different gnd strategies Locally, floating, multipoint, A general grounding policy should be defined. Even in sub-detectors that are intrinsically immune to noise, grounding should be coordinated in order to avoid EM radiation to neighbors. Special attention should be paid to large floating system due to the creation of uncontrolled noise paths. A detailed definition of electrical schematics and grounding techniques may be used to start coordinating the installation of sub-systems These activities will be carried out by a group of people (Belle II) It is recommended to evaluate the grounding technique at prototype level before installation It will help to take corrective actions in advance 13 de 28

4. Cabling issues There are two elements that play an important role in the electromagnetic noise level of any experiment: Cables Racks They may cause many EMC problems: Cable radiation Cable susceptibility Malfunctions due to high electronics density The EMC effects of this type of elements may be decreased by design ( layout and connectivity) Some recommendations were presented They may be implemented wherever possible. 14 de 28

4. Cabling issues Cables and racks components of different EMC categories should be laid separately wherever possible 15 de 28

4.1 Sub-detector cabling The cable layout and power levels of each subdetector have been discussed during the meetings. There is a wide variability of different options Type of cable Some of them are new In some cases it is planned to use Belle I cables Power levels KV, V, Signal, power Common cable channels have been shown There are some areas that need to be analyzed in detail to avoid interference problems Some cables are shielded and others not at all 16 de 28

4.1 Sub-detector cabling PXD SVD 17 de 28

4.1 Sub-detector cabling CDC Definition of cable power levels +5.5, +3.8, +2.0, +1.5 ARICH 18 de 28

4.1 Sub-detector cabling layout levels Types Exit radially from the magnet to readout crates nearby on perimeter of magnet 12V, 5V, 6kV, -3.5kV Unshielded twist-n-flat signal cable, RG-59 HV cable eklm 19 de 28

4.2 Cabling summary The cable layout and power levels of each sub-detector have been partially presented Some areas are common to different sub-detectors and mix different types of cables Detail analysis is required Attention should be paid to cable shield as well as noise sources. Interference evaluation: Noise sources vs type of cable A collection of safety rules beyond the ampacity of the cables should be defined and communicated to all sub-detectors Noise & Transients fuse coordination, electronic protection, de-rating cable ampacity for cable bundles It is recommended to create a committee that reviews and enforces that the cable and wire layout complies with rules 20 de 28 Belle II and KEK members

5. EMC issues Analysis & tests to ensure the compatibility level among noise sources and victims have started This noise control is being tackled at two levels 21 de 28 Noise emissions analysis Noise emission test (conducted and radiated) Noise immunity analysis Signal circuit analysis It will help to define grounding topologies Noise Immunity test Evaluate grounding topologies Ensure the compatibility of the FEE Subsystem evaluation: Signal to noise quantification

5.1 EMC issues - Emissions One of the most important noise sources in Belle II are the power supplies. Several of them have been developed with DC-DC They have EM emissions Radiated Conducted Emissions The spectra content is very closely related to : Switching frequency - Topology Few khz up to MHz The emission level of the power supply has to be coordinated: Sub-detector level Experiment level 22 de 28

db A / m db A 5.1 EMC issues - Emissions 60 50 CM DCDC5 DIF Steering ST4V3 40 30 20 10 0-10 -20 PXD 10 4 10 5 10 6 10 7 Frequency 60 Radiated - H 40 20 0-20 -40 23 de 28 10 4 10 5 10 6 10 7 Frequency

5.2 EMC unit analysis: Noise immunity Are the PS noise emissions (or other) compatible with the FEE?? Do we have enough safety margin? Noise sources that deteriorate the FEE performance are: Intrinsic thermal noise EM contribution detector FEE PS - others n a (t) n th (t) n in (t) n ps (t) This noise defines the minimum signal level that the FEE can process Thermal noise dominant effect EMI contribution characterization important The characterization of EMI contributions may be carried out via : Modeling and simulation of system Immunity tests on prototypes The main goals of this EM characterization are: Evaluate grounding topologies Ensure the compatibility of the FEE Subsystem evaluation : Signal to noise quantification 24 de 28

5.2 EMC issues - Immunities ECL System Verification PXD bklm Signal circuit analysis 25 de 28

5.3 EMC summary Analysis and test to ensure the compatibility level among noise sources and victims has started. The noise control is tackled at two levels Noise emissions Noise immunities Some subsystems have presented EMC plans and tests but it is still necessary to prepare a detailed global plan. This plan will help to define sensitive frequencies that may interfere among sub-detectors Some of the immunity tests will be very useful for final grounding topology of each sub-detector Still under development 26 de 28

6. Future Plans Electrical safety rules for Belle II need to be clarified. An overall "Belle II" grounding diagram and more detailed EMC plan should be prepared. Each sub-detector system will provide a very detailed /grounding overview (simplified schematic) & EMC plans It will be necessary to establish a grounding and EMC responsible at KEK in order to follow the indications. This person may act now as a link person Belle II - KEK It is planned to follow up all plans in order to define global aspects of the Belle II integration Cabling (Short term) Grounding (Short-medium term) EMC (long term) 27 de 28

7. Conclusions A general overview of the status and plans of the grounding and EMC issues has been presented EMC & grounding activities started one and a half years ago All sub-detectors have been involved Several meetings were held On July, we had a GND & EMC review at VPI, USA This review has produced a significant step forward Groundings configuration Cables layout EMC issues This is only the beginning of a long work. 28 de 28