Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

Similar documents
OPERATING MANUAL. Earth Resistance Meter MRU-21. SONEL SA ul. Wokulskiego Świdnica, Poland

OPERATING MANUAL EARTH/GROUND RESISTANCE METER MRU-200-GPS

OPERATING MANUAL EARTH RESISTANCE METER MRU-200-GPS

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

Fluke and

Insulation Testers and Earth Ground Testers

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

Indeks: WMXXCMM60 Advanced Industrial Multimeter

MS2030 CAT III 600 V A V AUTO RS232

GSC57 Rel of 257/10/05

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

GAMMA 20 DIGITAL MULTIMETER

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

3B SCIENTIFIC PHYSICS

GROUND TESTERS For all of your Ground Testing needs...

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Instruction Manual for Digital Grounding Resistance Meter

GROUND RESISTANCE TESTERS

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Testboy TV 416/432(A) CEE adapter*

GROUND RESISTANCE TEST EQUIPMENT

DET4 Series. 4-Terminal Earth/Ground Resistance and Soil Resistivity Testers. DET4 Series Earth/Ground Resistance & Soil Resistivity Testers

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

MIT510/2, MIT520/2 and MIT1020/2

User Manual 4 wire Earth Resistance Tester Model GRT300

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

DM-III MULTITEST Power Quality Recorder

Family 400 meters Rel /04/2007

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Indeks: WMGBPAT815 Miernik bezpieczeństwa sprzętu elektrycznego

MIT415 Insulation tester

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Multifunction Digital

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

6470-B. User Manual DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Electrical measurement technology. Re-invented.

MIT510, MIT520 and MIT1020

USER MANUAL INSULATION RESISTANCE METER MIC-5010

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER. User Manual ENGLISH. Shop for AEMC products online at:

Digital Clamp Meter. User Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

CONTENT Ⅰ. Brief introduction... 3 Ⅱ. Technical specification Base Conditions and Working Conditions General specification...

Measure voltage without test leads. Product Highlights

HT COMBI419. Innovative meter designed to perform all safety test

Eurotest 61557, Instaltest 61557

1650 Series Multifunction Installation Testers

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Model DIGITAL MULTIMETER

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

GAMMA 12 DIGITAL MULTIMETER

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Working under tension. Voltage testers.... convincing solutions

SUBJECT TO CHANGE WITHOUT NOTICE

Current clamps for AC current

IDM 98-III & IDM 99-III Digital Multimeters

E Series 9.00 (1/2) E series

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

Analog Digital Multimeter with Insulation Resistance Measurement

AMM-1022 Digital Multimeter USER`S MANUAL

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH. User Manual

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH. User Manual

OPERATOR S INSTRUCTION MANUAL

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Current clamps for AC current

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

TORKEL 900-series Battery Load Unit

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

G SAFETY WARNINGS. LT300 High current loop tester. User guide

1507/1503. Insulation Testers. Technical Data. Features and benefits:

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OPERATING MANUAL METER FOR ELECTRICAL INSTALLATION PARAMETERS MPI-520

GOSSEN METRAWATT. Testers

Electrical Measuring Instruments. Vol.3.

Flexible AC current probes

UAT-600 Series. amprobe.com

GAMMA 10 DIGITAL MULTIMETER

A Clamp W/TRMS

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Digital Clamp Meter Model: &

Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

MIT400/2 CAT IV Insulation testers

Dawson DDM190. Digital Multimeter User s Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

OPERATING MANUAL FAULT LOOP IMPEDANCE METER MZC-304

APPA 300 Series. The Most User-Friendly High Performance Multimeter

BENNING. CM7 Electrical Tester. Service Information

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

TT-SI MHz Active Differential Probe

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Transcription:

MRU-30 Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter Description The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3- pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can't be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages. Robust and weatherproof (IP65) - no ingress of dust, water protected by a nozzle against enclosure from any direction. Ergonomic casing - small and handy casing to make the measurements more convenient than before. Built-in rechargeable battery - saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket! Clear on-screen notes - displayed on screen before and after the measurement to alert user of possible dangers and irregularities. Many measurement methods available in a small, portable casing. Virtual instrument application of Sonel MRU-30 Technical Specification

It allows to take the measurements of: earthing resistance using auxiliary electrodes, earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing), earthing resistance using double clamps for measuring multiple earthing without underground connections. ground resistivity (Wenner method), continuity of equipotential bondings and protective conductors (meeting the requirements IEC 60364) with autozero function with current 200mA. Additionally: measurement of resistance of auxiliary electrodes RS and RH, measurement of interference voltage, measurement in the presence of interference voltage in the power network with frequency 50Hz, 60Hz, selection of maximum measuring voltage (25V and 50V), introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft), memory of 990 measurements (10 banks of 99 cells each), calibration of clamp used, data transmission to the computer (USB), indication of battery state. Measurement of interference voltage U N (RMS) 0...100 V 1 V ±(10% m.v. + 1 digit) Measurement of continuity of equipotential bondings and protective conductors (R cont ) measurement range to IEC 61557-4:2007: 0,13 Ω...1999 Ω 0,00...9,99 Ω 0,01 Ω

10,0...99,9 Ω 0,1 Ω ±(2% m.v. + 3 digits) 100...1999 Ω 1 Ω measurement current: under short circuit >200mA 150 Hz (for networks 60 Hz) Measurement of earthing resistance (method 3- and 4-pole) measurement range to IEC 61557-5:2007: 0,53 Ω...9999 Ω (dla 50 V) 0,00...19,99 Ω 0,01 Ω 20,0...199,9 Ω 0,1 Ω ±(3% m.v. + 3 digits) 200,0...1999 Ω 1 Ω ±5% m.v. 2000...9999 Ω 1 Ω ±8% m.v. measurement current: under short circuit >20 ma, voltage on open terminals: selectable 25 V AC or 50 V AC, frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz). Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp) 0,00...19,99 Ω 0,01 Ω 20,0...199,9 Ω 0,1 Ω ±(3% m.v. + 3 digits) 200...1999 Ω 1 Ω ±5% m.v. 2000...9999 Ω 1 Ω ±8% m.v.

voltage on open terminals: selectable 25 V AC or 50 V AC, measurement current: under short circuit >20 ma, 150 Hz (for networks 60 Hz) Measurement of resistance of auxiliary electrodes R H i R S 0...999 Ω 1 Ω 1,00k...9,99 kω 10,0k...19,9 kω 0,01 kω 0,1 kω ±(5% m.v.+ 8 digits) Measurement of multiple earthing resistance with using double clamps 0,00...19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits) 20,0...99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits) 150 Hz (for networks 60 Hz) Measurement of ground resistivity Measurement method: Wenner, ρ=2πlr E 0,00...9,99 Ωm 0,01 Ωm

10,0...99,9 Ωm 0,1 Ωm 100...999 Ωm 1 Ωm 1,00...9,99 kωm 0,01 kωm depending on measurement accuracy R E with 4p method, but not less than ±1 digit 10,0...99,9 kωm 0,1 kωm 100...999 kωm 1 kωm L distance between probes: 1...50 m.. or 1...150 ft Electric security: type of insulation: double, according to EN 61010-1 i IEC 61557, measurement category: CAT III 300V wg EN 61010-1, protection class acc. to EN 60529: IP65, Rated operational conditions: operation temperature: -10...+55 C, storage temperature: -20...+80 C, humidity: 20...90%, Other technical data: LCD display: segment, backlit, dimensions: 200x150x74 mm.