FIRESTRIP 30 Version No.3 Revision Date: 19/07/2013 Page 1 of 5

Similar documents
CERTIFICATE OF APPROVAL No CF 718 PILKINGTON GROUP LIMITED

CERTIFICATE OF APPROVAL No CF 284 INTUMESCENT SEALS

CERTIFICATE OF APPROVAL No CF SEALMASTER (A division of Dixon International Group Ltd)

CERTIFICATE OF APPROVAL No CF 581 CGI INTERNATIONAL LIMITED

CERTIFICATE OF APPROVAL No CF 5428 SEALMASTER

6.1. Glass & Glazing General

A F LCON PANEL PRODUCTS LTD

6.1. General: Glass & Glazing. Glass & Glazing

Title: Global Assessment Blankfort 30 & Blankfort 30+ Doorsets for 30 Minutes Fire Resistance. Report No: Chilt/A12151 Rev D. WF Contract:

Blankfort TM 60+ MDF. Description. Construction

Palusol SW Door Cores Technical Manual

6.1. General: Glass & Glazing. Glass & Glazing

Hardwood Splayed Bolection Bead. with FD60 Glass Types 1 ~ 12 (See page 6.5) when used with approved FD60 glazing systems. (See page 6.15).

Title: WF Report No: FEA/F98164 Revision M. WF Contract No: Prepared for: Pacific Rim Wood Ltd

THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM

The legal validity of this report can only be claimed on presentation of the complete report.

The basic tested construction for door leaves to this design comprises the following.

Title: Global Fire Resistance Assessment of EGGER FD30 & FD30 Decor 44mm Door Blanks. 30 Minutes Fire Resistance. Valid From: 18 th January 2016

Title: Global Fire Resistance Assessment of PT Yasanda Decorative Grooved Doorsets 30 Minutes Fire Resistance

A Guide to Best Practice in the Specification and Use of Fire-Resistant Glazed Systems

Simply Fire Doors FD60 Data Sheet

PFPF and FTSG Agreed Assessment Rules for: Timber Based Doorset. FTSG N288 (e)

CERTIFICATE OF APPROVAL No. ME 5048 WENG MENG INDUSTRIES SDN BHD

03/05. CI/SfB (22) scion. The beauty of natural wood

Unexposed face prior to testing

The legal validity of this report can only be claimed on presentation of the complete report.

IFC FIELD OF APPLICATION REPORT PAR/10341/01

CARE OF TIMBER DOORS ON SITE

General Product & Quality Specification

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

A F LCON PANEL PRODUCTS LTD

Optima fd30. Technical Support Manual. Innovative Solutions. Halspan Fabrication Door Assemblies Frames Doors Acoustic Doors Glass Fire Doors

CERTIFICATE OF APPROVAL No CF 370 SAMUEL HEATH & SONS PLC

Optima fd60. Technical Support Manual. Innovative Solutions. Halspan Fabrication Door Assemblies Frames Doors Acoustic Doors Glass Fire Doors

General guidance. L20Doors/ Shutters/ Hatches. 1 Fire doors

Optima fd30. Technical Support Manual. Innovative Solutions. Halspan Fabrication Door Assemblies Frames Doors Acoustic Doors Glass Fire Doors

EI60 FD60 EI60 SMOKE SEAL. F6002 R UK - Feb (pair) Rebated meeting edge

The perfect solution for imperfect walls

05/11. CI/SfB (22) fire & sound. tenon. A cost effective performer.

FD30 & FD60 FRAME & DOOR INSTALLATION GUIDE

CERTIFICATE OF APPROVAL No CF 731 ALLGOOD PLC

Liniar Window. installation guide

INSTALLATION MANUAL STOREFRONT DOORS

9.1. Door Assembly Coordination. Ÿ Architrave is not described in

SPECIAL DOORS & FIRE DOORS

Doors & Blinds. Free no obligation survey & quotation service Call: Web:

CERTIFICATE OF APPROVAL No. ME 5047 WENG MENG INDUSTRIES SDN BHD

A F LCON PANEL PRODUCTS LTD

fd30 Technical Support Manual Innovative Solutions Pro Tech fd30 to Access and Fire Safety

light Non-rebated and non-latched single action door (NR) EI30 / EI60

Fire Door Maintenance Scheme Accepted Repair Techniques

DOUBLE GLAZING SYSTEMS

FLAMEBREAK. Lippings & Facings 1. General: Rev.D

Installation Instructions Stainless Steel Wall Panels


CERTIFICATE OF APPROVAL No CF 767 RUTLAND UK

A F LCON PANEL PRODUCTS LTD

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom

Joinery and Flooring. Door Linings and Casings. Flooring. Lining Casing. Mouldings. Door Seals and Fire Strips

Glossary of Terms U.K.

Easyfix. Easyglaze. Superglaze. Filmglaze

Aluminium Window Scheme to BS4873 & PAS24:2016

Method of Build 1. Fire. Sound

Innova. Concealed frame doorsets. Installation instructions

This section includes a detailed guide to what sound attenuation is and how to attain the optimum performance.

EMAC 001 ACCESS PANEL

Installation Instructions Palladium 3D Hi Impact Wall System, Partial Height with Color Matched Caulk Joints

A F LCON PANEL PRODUCTS LTD

Title: The Fire Resistance Performance of Advantage, Advantage Plus and NOR400 Letterboxes and DV Door Viewers within Timber Based Doorsets

fd90 Technical Support Manual Innovative Solutions Halspan Fabrication Door Assemblies Frames Doors Acoustic Doors Glass Fire Doors

DAP Latex Window Glazing

integra living doorsets

In-line Patio Fabrication & Installation

The Fire Resistance Performance of Advantage, Advantage Plus and NOR400 Letterboxes and DV Door Viewers within Timber Based Doorsets

FIXED FLAT ROOFLIGHT: INSTALLATION INSTRUCTIONS (Double & triple glazed)

CAUTION. Fitting and Fixing Guidelines for Rio French Doors - Outward Opening.

Key products guide: External water based preservatives and isolating products

Standard program overview Steel smoke-proof doors

Side Light Frame Pack Assembly Instructions

05/11. CI/SfB (22) flexplus. tenon. Versatility through simplicity.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Gluing windows with SABA Glasstack 760

Playaway Swiss Cottage Assembly Instructions

Side Light Frame Pack Assembly Instructions

French Door Pairs. Assembly Instructions IBFD54NN - ISSUE AC

Making Tomorrow Safer

Working Methods TOTAL JOINERY REPAIR SOLUTIONS

experts in veneer doors and panels since 1837

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

GRIP & GRAB ADHESIVE

Installation Instructions

Halspan FD120 Technical Support Manual

Working Methods TOTAL JOINERY REPAIR SOLUTIONS

Potting Store Assembly Instructions

Palladian/ Keystone Models 202/204 Maintenance Kit

Architect: Daluz/González Architekten Photo: Peter Baracchi CP 155 SLIDING DOOR INSTALLATION GUIDE. Edition 15/21

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

A Shell construction

Method of Build 1. General

Adjustment Has adjustment strike block screw for sealing action adjustment.

Transcription:

Version No.3 Revision Date: 19/07/2013 Page 1 of 5 DESCRIPTION An Intumescent Strip Sealant 12mm x 3mm which can provide 30 minutes resistance to the passage of fire and smoke when used to glaze a wide variety of glass types into internal doors and softwood or hardwood timber screens. Please ask our customer care team to send you a copy of our Certifire certificate CF297 for clear and concise application details for Firestrip 30 and Firestrip 60 and new increased glass sizes. KEY FEATURES Fully tested to provide 30 minutes resistance to the passage of fire and smoke in timber doors and screens. BWF Certifire Scheme Certificate No. CF297 for use in timber screens and doors for periods of 30 minutes fire resistance. Quick, clean and easy to apply. Excellent high tack surface provides good adhesion. Tested with a wide variety of non-insulating and insulating glass types. Can be overcoated with paints and decorative wood stains. Very cost effective compared to other rigid/semi-rigid fire resistant materials. Non-toxic. TECHNICAL APPROVALS BS476: Part 22: 1987 Test report WFRC 70068 BS 8000 Part 7: 1990. BS476: Part 22: 1987 Test report WFRC C82960 EN1634: Part 4:1998 Test reports Chilt/RF02065 Chilt/RF02064 and Chilt/RF02063 EN1364-1: 1999 WFRC 135349 EN1364-1: 1999 WFRC 142630 BWF - Certifire Fire Door and Doorset Scheme - Certificate No 297 Glass & Glazing Federation Glazing Manual Section 2.8 Fire Resistant Glazing, 13. Table of Tested Products and Materials. 9.1.2 Glazing Materials Strips. FIRAS register of specialist fire protection materials manufacturers & suppliers. USES Firestrip 30 is used for glazing non-insulating and insulating glass into timber fire doors and softwood or hardwood timber screens with hardwood beads using Hodgson FG2 Glazing System. Important: The performance of Firestrip 30 is dependent on the use of suitable fire resistant glass and suitable frame design. If in any doubt, please contact Hodgson Technical Services for further information.

Version No.3 Revision Date: 19/07/2013 Page 2 of 5 GLASSES WHICH CAN BE GLAZED WITH INTO TIMBER FRAMED SCREENS BS476: Part 22: 1987 WFRC C82960 Non-Insulating Glasses Manufacturer Glass Maximum Area (m²) Maximum Dimensions (m) CGI International Pyroguard Clear and Wired (7.2mm) C730 2.0 2.4 Pilkington Glass Pyroshield Clear, Safety and Textured (6mm) 3.6 2.4 Pyrodur 10mm 3.1 2.5 Schott Glass Pyran S 6mm 3.6 2.45 Caradon Everest Techniglass Pyrocet 6mm 4.2 2.1 Glaverbel Pyrobelite 7mm 2.9 2.2 Vetrotech, St Gobain Pyroswiss 6mm 3.0 2.0 Fivestar 5mm 1.5 1.5 Insulating Glasses Manufacturer Glass Maximum Area (m²) Maximum Dimensions (m) Pilkington Glass Pyrostop 15mm 2.8 2 Glaverbel Pyrobel 12mm 2.8 2.3 Vetrotech, St Gobain Contraflam 22mm 2.6 2.2 Design Information WFRC C82960 The glazing material shall be Firestrip 30, 12mm wide x 3mm thick between glass and the beads. Hardwood or non-combustible material setting blocks shall be used to achieve the required edge cover. Screens: Screens should be designed using softwood (plus Ash and Iroko) with a minimum density of 560kg/m 3 and with a minimum cross section of 80mm x 45mm or hardwood (except Ash and Iroko) with a minimum density of 650kg/m 3 and with a minimum cross section of 65mm x 45mm. Beads: Choose any type of hardwood that has a minimum density of 620kg/m 3. The beads shall be a minimum 21mm x 13mm (slightly larger for Ash or Iroko) and 25mm x 25mm when used with Pyrocet. The beads shall be chamfered by 10 when used with non-insulating glasses and square or chamfered by 10 for insulating glasses. Beads shall be fixed with 1.5mm diameter x 32mm long pins or 32mm screws, screw fixed at 45 placed at a maximum of 50mm from each corner and at a maximum of 150mm centres.

Version No.3 Revision Date: 19/07/2013 Page 3 of 5 GLASSES WHICH CAN BE GLAZED WITH INTO TIMBER DOORS CERTIFIRE No. CF297 Manufacturer Glass Maximum Pane Height (mm) Maximum Pane Width (mm) Maximum Area (m²) CGI International Pyroguard 7.2mm Glaverbel Pyroshield Clear, Safety and Textured (6mm) Schott Glass Pyran S 6mm Southern Ceramic Supplies Firelite Pilkington Glass Pyrodur Plus 2358 (at 950mm wide) 1093 (at 2050mm high) 2.24 The aspect ratio of the glass may be unlimited within these glass dimensions. Design Information The glazing material shall be Firestrip 30, 12mm wide x 3mm thick between glass and the beads. Hardwood or non-combustible material setting blocks shall be used to achieve the required edge cover. The glazing beads shall be of Sapele, or equivalent or higher density (610 kg/m 3 ), sections, 22mm wide by 21mm high, chamfered by approximately 13 and fixed using 1.5mm diameter, 50mm long steel pins at a maximum of 100mm centres and angled to pass under the face of the glass. Firestrip 30 is suitable for installation directly into a solid (high-density) flax board or laminated timber door leaf core. When joinery type door leaves are used, the timber for the rails and stiles shall have a density of at least 400 Kg/m 3. There are a number of alternative framing systems available, which are also suitable for use with Firestrip 30, which may not have specific test evidence. These framing systems are those listed in the CERTIFIRE Product Register as suitable for use with intumescent based glazing systems and up to the maximum sizes listed for the specific system. When the framing system is determined as suitable using this method, and the system shows sizes smaller than allowable above, the aperture sizes specified in the framing system certificate shall take precedence. European Fire Testing Softwood Timber Screens 30 minutes integrity BS EN 1364 part 1: 1999 - WRFC Test Report 142630. Firestrip 30 has been successfully tested with Pyroshield from Pilkington for a period of 37 minutes against BS EN 1364 part 1. Please contact Hodgson or Pilkington for information on maximum glass sizes and design details. European Fire Testing Softwood Timber Screens 30 minutes integrity BS EN 1364 part 1: 1999 - WRFC Test Report 135349. Firestrip 30 has been successfully tested with Pyran S from Schott Glass for a period of 38 minutes against BS EN 1364 part 1. Please contact Hodgson or Schott for information on maximum glass sizes and design details.

Version No.3 Revision Date: 19/07/2013 Page 4 of 5 European Fire Testing Timber Doors: 30 and 60 minutes integrity BS EN 1634 part 1: 2000:- Chiltern RF02063 30minutes Chiltern RF02064 30 minutes Chiltern RF02065 60 minutes Firestrip 30 has been tested with Fivestar, Swissflam Lite SFL30-N2 and Swissflam Lite SFL60-N2 in softwood doors for both 30 and 60 minutes integrity (depending on glass type). Please contact Hodgson or Vetrotech for information on maximum glass sizes and design details. PERFORMANCE Adhesion: Excellent to glass and timber. Compression to seal: Positive compression. Density: 1.2g/cm 2 Force to compress by 20%: 1.4kg/cm 2 Movement accommodation: ±10% Paintability: Excellent. Resistance to mould: High. Service life (predicted): in excess of 20 years. Service temperature range: +5ºC to +40ºC Shrinkage: <1% Slump: Nil. Staining: Nil. Tack: Very Good. Tensile strength: 1.3kg/cm 2 UV resistance: Excellent. APPLICATION PROPERTIES Application temperature range: +5 C to +30 C Shelf life: 12 months when stored flat in original packaging in cool, dry conditions. INSTRUCTIONS Surface preparation: All surfaces should be clean, dry and free from frost, grease and loose materials. Application: Secure one set of glazing beads to act as a rebate if the opening is not already rebated. Pins or screws should be angled at 45. Apply Firestrip 30 on the paper along the rebate upstand of the top rebate by running the edge of the backing paper along the rebate platform so that the strip comes up to the sightline. For larger rebates it may be necessary to lift the paper above the platform to ensure that the Firestrip 30 comes up to the sightline. Repeat the application to the sides and then the bottom rebate. Remove backing paper. Butt the corner joints, do not overlap. Position setting blocks. Centralise glass in frame on setting blocks. Press firmly around the edge of the glass to ensure that contact with the surface of Firestrip 30 is achieved. Apply Firestrip 30 to the glass in the same way as it was applied to the upstands by running the edge of the paper along the rebate platform or alternatively direct to the beads. Remove the backing paper. Bed the beads to the Firestrip 30 by applying pressure to obtain good contact between the strip and the bead. Fix the beads with pins or screws in accordance with the design requirements of the installation. Pins or screws should be angled at 45 to pass beneath the glass.trim off any Firestrip 30 above the sight line with a sharp knife. PACKAGING Standard: 12mm x 3mm (15m) x 10 reels Trade Pack: 12mm x 3mm (10m) x 12 reels Available colours: Mahogany and off-white

Version No.3 Revision Date: 19/07/2013 Page 5 of 5 GENERAL Firestrip 30 is part of a full range of cartridge sealants, tapes and fire resistant foam designed for use by the professional user to resist the passage of fire and smoke. For further information please contact our Customer Care Team or visit our Website. The information given in this product data sheet is based on laboratory tests and experience which we believe to be correct. Properties quoted are typical and do not therefore constitute a specification. In view of the wide range and variability of substrates, we would advise that our product should be tested by the user to establish suitability for its intended application. E &OE.