kw Digital panel meter ½-digit DV, DT Without setpoints Analog status /0/04 - panelmeter_gb.doc page subject to alterations; errs including printer s errs
Digital panel meter Direct voltage Direct current Shunt Alternating voltage Alternating current Resistance Potentiometer PT00/PT000 Thermocouple kw Direct voltage, direct current ORDER NUMBER OF TYPE (without options) 0 V 0/4-0 ma 0 V signal input (DC) 4 5 6 7 Power supply Power supply ( ) DV.00.850B DV.00.870B Transmitter connections see page 6 Direct voltage (Shunt) 60 mv 50 mv 0 V signal input (DC) 4 5 6 7 Power supply Power supply ( ) DV.00.850B DV.00.870B Alternating voltage, alternating current 0 V 5 A 0 V signal input (AC) 4 5 6 7 Power supply Power supply ( ) Standard DV.004.850B True effective value RMS DV.04.850B Standard DV.004.870B True effective value RMS DV.04.870B Resistance, potentiometer Rx Thermocouple L, J K Thermocouple Power supply Measuring range Power supply Measuring range ( ) Power supply Power supply ( ) 0kΩ DV.506.850B Measuring range 00kΩ DV.606.850B Measuring range MΩ DV.706.850B 0kΩ DV.506.870B Measuring range 00kΩ DV.606.870B Measuring range MΩ DV.706.870B DT.40x.850B DT.40x.870B Typ L (FeCuNi - DIN) -50 up to 500 C Typ J (FeCuNi - americ.) -50 up to 500 C Typ K (NiCrNi) -00 up to 800 C (fill in the desired type of thermocouple in the der number instead of x) status /0/04 - panelmeter_gb.doc page subject to alterations; errs including printer s errs DV, DT
PT00 ( wire) Power supply ORDER NUMBER OF TYPE (without options) wire DT.0.850B (99,9 C) wire DT.06.850B (600 C) wire DT.0.850B (99,9 C) wire DT.06.850B (600 C) Power supply wire DT.0.870B (99,9 C) PT00 ( wire) ( ) wire DT.06.870B (600 C) wire DT.0.870B (99,9 C) wire DT.06.870B (600 C) PT00 -wire PT00 -wire PT00 -wire PT000 ( wire) PT000 -wire Power supply Power supply ( ) Power supply Power supply ( ) wire DT.60.850B (99,9 C) wire DT.60.870B (99,9 C) wire DT.606.850B (600 C) wire DT.606.870B (600 C) OPTIONS DV 00... Direct voltage DV.00... Shunt DV.004... Alternating voltage DV.006... Resistance DT.40x... Thermocouple DT.x0.../.x06... PT00/0 ( wire) l LED green x x x x x x Protection IP54 at the front x x x x x x Protection IP65 at the front x x x Plug in terminal x x x x x Analog 0-0 VDC/ ma x x x x x x Analog 0-0 ma/load 500 Ω x x x x x x Analog 4-0 ma/load 500 Ω x x x x x x Analog 0-0 VDC/ ma (supply voltage ) x x x x x x Analog 0-0 ma/load 500 Ω (supply voltage ) x x x x x x Analog 4-0 ma/load 500 Ω (supply voltage ) x x x x x x Analog with customer specified offset (S6) x x x x x x Analog and protection IP65 See series PVE 8 signs) x x x x X x Other power supplies on demand x x x x X x Setpoints See series PVE status /0/04 - panelmeter_gb.doc page subject to alterations; errs including printer s errs DT
Technical data f all units of the DV, DT serie, if not indicated otherwise Dimensions Housing B48 x H48 x T mm, including screw terminal (T=47 mm, including plug in terminal) Assembly cut out 45.0 0.6 x 45.0 0.6 mm Fastening special quick plastic clamp proper to fix in wall thickness up to 50 mm Housing material PC/ABS-blend, colour black, UL94V-0 Protective system at the front IP40 connection IP00 Weight approx. 0.8 kg Connection at the rear side via terminals up to.5 mm Input DV.00... Direct voltage, Direct current Measuring range 0-0 V, 0-0 ma - 4-0 ma - all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (-500 up to 500) Input resistance Ri with 0 V = ~55 kω 0 ma = ~00 Ω DV.00... Direct voltage (Shunt) Measuring range 0-60 mv, 50 mv - all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (-00 up to 00) Input resistance Ri with 60 mv = ~5 kω 50 mv = ~9 kω DV.004... Direct voltage, Direct current Measuring range 0 V, A, 5 A all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (-00 up to 00) Input resistance Ri with 0 V = ~00 kω A = ~76 mω 5 A = ~56 mω DV.006... Resistance Measuring range 0 kω, 00 kω, MΩ Offset adjustment suppted by offset potentiometer (-00 up to 00) DT.x0... PT00 Sens -wire, -wire Measuring range -50.0 up to 99.9 C Sens current approx. ma DT.x06... PT00 Sens -wire, -wire Measuring range -00 up to 600 C Sens current approx. ma DT.60... PT000 Sens -wire Measuring range -55 up to 99,9 C Sens current approx. 0. ma DT.606... PT000 Sens -wire Measuring range -00 up to 600 C Sens current approx. 0. ma DT.40x... Thermocouple L FeCuNi (DIN) -50 up to 500 C J FeCuNi (americ.) -50 up to 500 C K NiCrNi -00 up to 800 C Output F all versions Analog 0-0 VDC/ ma (0.% of measuring value, /-0.05% of full scale) 0-0 ma, 4-0 ma - load 500 Ω (0.% of measuring value, /-0.05% of full scale) Offset Not changeable, offset cresponds to 0 digit, see options. Final value Adjustable to 0 V 0 ma, within the indication range 50 to 999. (The measuring inputs are not from the!) DT.x0... Final value 00 C 0 V 0 ma adjustable f range from 5.0 C up to 99.9 C DT.x06... Final value 600 C 0 V 0 ma adjustable f range from 80 C up to 600 C DT.40x... Final value 500 C 0 V 0 ma adjustable f range from 80 C up to 500 C Final value 800 C 0 V 0 ma adjustable f range from 80 C up to 800 C status /0/04 - panelmeter_gb.doc page 4 subject to alterations; errs including printer s errs
Technical data Accuracy F all versions Measuring principle Dual-Slope-Integration DV.00... Temp. drift ~ 00 ppm/k DV.00... ~ 50 ppm/k DV.004... I ~ 00 ppm/k / U ~ 00 ppm/k DV.006... ~ 00 ppm/k DT.40x... ~ 00 ppm/k DT.x0... ~ 00 ppm/k DT.x06... ~ 00 ppm/k F all versions Measuring fault /-0.% of measuring value, /- digit DV.0x4... Frequency range Nominal precision 40 Hz up to 000 Hz Measuring fault Voltage range: /-0.5% of measuring value, /-digit A range: /-0.5% of measuring value, /-digit 5 A range: /-0.5% of measuring value, /-digit Measuring principle (input) Via rectifier effective value with sine wavefm only DV.x4... Frequency range Nominal precision 40 Hz up to 000 Hz Measuring fault Voltage range: /-0.5% of measuring value, /-digit, crest fact A range: /-0.5% of measuring value, /-digit, crest fact 5 A range: /-0.5% of measuring value, /-digit, crest fact Measuring principle (input) True effective value RMS DT.x0... Measuring fault max. /-0.5 C, /- digit DT.x06... Measuring fault max. /- C, /- digit DT.60x... Measuring fault R L 0 Ω = /-K R L > 0 Ω 0 Ω = /-K DT.40x... Measuring fault type J, L max. 5 C Measuring fault type K range from -00 C up to -50 C max. 5 C range > -50 C up to 600 C max 5 C range > 600 C up to 800 C max 5 C F all versions Resolution /-999 digit DT.x0... 0. C DT.x06... C DT.40x... C Power unit Supply voltage /- 0% (50-60 Hz), (8-0 V), (/-0%) Consumption max. 5 VA Indication Display LED with 7 segments, 0 mm high, red ½-digit = indication 999 Overflow by showing on the fourth digit DV.00... DV.00... DV.006... Decimal point Adjustable by bridging on front side. Measuring time sec. Blanking Blanking out of last digit (selectable by bridge). Plus sign Selectable by bridging on front side DV.004... Decimal point Adjustable by bridging on front side. Measuring time sec. Blanking Blanking out of last digit (selectable by bridge). DT.xx... DT.xx6... Measuring time sec. Ambient Wking temperature 0 up to 60 C conditions Sting temperature -0 up to 80 C Housing: mm 48 mm 48 mm mm(with plug in terminal 48 mm) 4 mm 4 mm 0,6 mm 45,0 mm -0,0 mm Assembly cut out 0,6 mm 45,0 mm -0,0 mm 6 mm status /0/04 - panelmeter_gb.doc page 5 subject to alterations; errs including printer s errs
Connection diagrams DV.00... -wire: 4-0 ma -wire: 0-0 ma -wire: 0-0 V /0-5 V 4-0 ma 0- V / -6 V 6 7 6 7 6 7 Signal - Transmitter Signal Transmitter Transmitter i.e. /DC - i.e. /DC - i.e./dc Signal Ordering code DV, DT Digital panel meter D V 0 0 8 5 0 B Basic model Internal index Mechanical options Voltage metering V 0 Protection IP40 Temperature metering T Protection IP65 Protection IP54 5 Plug in terminal, protection IP54 Number of digits 6 Plug in terminal, protection IP40 ½ digits 7 Plug in terminal, protection IP65 Sens supply Power supply No sens supply 0 5 7 ( ) Temperature devices PT00- wire PT00- wire Size of housing PT000- wire 6 8 Thermocouple 4 Resistance Measuring input Measuring range up to 0 kω 5 Direct voltage, direct current Measuring range up to 00 kω 6 Direct voltage, shunt measuring Measuring range up to MΩ 7 4 Alternating voltage, alternating current 6 Resistance Alternating voltage, current Range PT00/000 (00 C) f DT Standard 0 6 Range PT00/000 (600 C) f DT True effective RMS L Thermocouple type L f DT J Thermocouple type J f DT K Thermocouple type K f DT Outputs No 0 0-0 V 0-0 ma 4-0 ma status /0/04 - panelmeter_gb.doc page 6 subject to alterations; errs including printer s errs