TECHNICAL MANUAL CALIBRATION PROCEDURE FOR HIGH VOLTAGE INSTRUMENTS

Similar documents
TECHNICAL MANUAL CALIBRATION PROCEDURE FOR DIGITAL MULTIMETER 34401A (HEWLETT-PACKARD)

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR MULTIMETERS

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR LCR METER 875A, 875B (B & K PRECISION) This publication replaces T.O. 33K dated 30 August 2011.

CLAMP-ON METERS THIS PUBLICATION SUPERSEDES NAVAIR 17-20AQ-32 DATED 1 OCTOBER 2009

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR THREADED PLUG GAGES. This publication replaces T.O. 33K dated 30 January 2013.

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR SYNTHESIZED SIGNAL GENERATOR 7200() (GIGA-TRONICS)

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

CHANGE 1 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

*This bulletin supersedes TB , dated 18 July 1988, including all changes.

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Change 4 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR VOLTAGE STANDARAD, JOHN FLUKE, MODELS 332A, 332B, AND 332B/AF

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DIGITAL MULTIMETER HEWLETT-PACKARD MODELS 3435A AND 3438A

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

# Digital Multimeter

*TB DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

1.General instructions Specifications Description...7

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR GAGE BLOCKS MECHANICAL COMPARISON. This publication replaces T.O. 33K dated 30 December 2013.

CHANGE 1 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

R/C SMD Tweezers Multimeter Model RC200

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

Exercise 3: Voltage in a Series Resistive Circuit

BENNING. CM7 Electrical Tester. Service Information

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Digital Clamp Meter (TRMS) Model : 2727

1507/1503. Insulation Testers. Users Manual

Pen Multimeter. Model

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

BENCH METER Model>9803. Wavecom Instruments

MODEL: D03128 CLAMP METER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AP034-OM-E Rev D ISSUED: January 2000 ²

Sales: Technical: Fax:

Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL

True RMS Bench Multimeters 2831E and 5491B

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

Model 7000 Low Noise Differential Preamplifier

Electrical Multimeter

OPERATING AND MAINTENANCE MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

400Amp True RMS AC/DC Clamp Meter Model EX613

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

INSTRUCTION MANUAL DIGITAL MULTIMETER

AUTO RANGING DIGITAL MULTIMETER

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

DM-45 Digital Multimeter

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Model 3102D 0-2 kv H.V. Power Supply

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

OPERATOR S INSTRUCTION MANUAL

Model Operating Manual

200Amp AC Clamp Meter + NCV Model MA250

M-1000D DIGITAL MULTIMETER

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Figure 1(a) shows a complicated circuit with five batteries and ten resistors all in a box. The

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

Analog Technologies. Multimeter 15B and17b

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

USER'S MANUAL DMR-6700

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

Model DIGITAL MULTIMETER

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Digital Clamp Meter. User Manual

OPERATING INSTRUCTION

TECHNICAL MANUAL DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL FOR AUDIO FREQUENCY AMPLIFIER AM-1780B/VRC (NSN ) (EIC: N/A)

True RMS Digital Multimeter Model:

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent 970-Series Handheld Multimeters Data Sheet

Bench Test Instruments and Handheld Oscilloscopes Basic Service

8588A Reference Multimeter

True RMS Bench Multimeters 2831E and 5491B

True RMS AC / DC Power Clamp Meter Model

Transcription:

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR HIGH VOLTAGE INSTRUMENTS Distribution Statement - Distribution authorized to U. S. Government agencies and their contractors for official use or for administrative or operational purposes only, 20 October 1989. Other requests for this document shall be referred to AFMETCAL Detachment 1/MLLW, 813 Irving-Wick Dr W, Suite 4M, Heath, OH 43056-6116. Destruction Notice - For unclassified, limited documents, destroy by any method that will prevent disclosure of the contents or reconstruction of the document. Published under Authority of the Secretary of the Air Force 30 AUGUST 1999 CHANGE 10-30 SEPTEMBER 2005

LIST OF EFFECTIVE PAGES INSERT LATEST CHANGED PAGES. DESTROY SUPERSEDED PAGES. NOTE: The portion of the text and illustrations affected by the changes is indicated by a vertical line in the outer margins of the page. Date of issue for original and changed pages are: Original...0... 30 August 1999 Change...9... 30 June 2004 Change...1... 30 May 2000 Change...10... 30 September 2005 Change...2... 30 March 2001 Change...3...30 December 2001 Change...4... 30 May 2002 Change...5...28 February 2003 Change...6... 30 May 2003 Change...7... 30 August 2003 Change...8...28 February 2004 TOTAL NUMBER OF PAGES IN THIS PUBLICATION IS 50, CONSISTING OF THE FOLLOWING: Page * Change Page * Change Page * Change No. No. No. No. No. No. Title... 10 A... 10 1-2... 10 3-4... 5 A-1... 10 A-2... 4 A-3 - A-4... 0 A-5... 1 A-6 - A-8... 0 A-9... 8 A-10 - A-13... 0 A-14... 6 A-15 - A-20... 0 A-21... 5 A-22 - A-31... 0 A-32... 6 A-33 - A-34... 0 A-35... 2 A-36... 3 A-37... 6 A-38 - A-39... 7 A-40... 8 A-41 Added... 9 A-42... 10 A-43 Added... 10 A-44 Blank... 10 *Zero in this column indicates an original page A Change 10 USAF

HIGH VOLTAGE INSTRUMENTS 1 CALIBRATION DESCRIPTION: Table 1. Test Instrument (TI) Performance Test Characteristics Specifications Method DC Voltage Range: 0 to 40 kvdc Apply a known Voltage 2 EQUIPMENT REQUIREMENTS: Accuracy: As specified in Appendix A Minimum Use Calibration Sub- Noun Specifications Equipment Item 2.1 HIGH VOLTAGE Range: 0 to 40 kvdc Universal Voltronics SYSTEM BRC-40-4-NA-1 Accuracy: ±0.05% 2.2 DIGITAL Range: 0 to 10 VDC, 10 G Hewlett-Packard Fluke MULTIMETER Input Impedance 3458A 8506A (2 ea) Accuracy: ±0.01% 3 PRELIMINARY OPERATIONS: 3.1 Review and become familiar with entire procedure before beginning Calibration Process. WARNING Unless otherwise designated, and prior to beginning the Calibration Process, ensure that all test equipment voltage and/or current outputs are set to zero (0) or turned off, where applicable. Ensure that all equipment switches are set to the proper position before making connections or applying power. 3.2 Connect all test equipment to 115 V/60 Hz power and allow a warm-up as required by manufacturer. NOTE For PMELs without the High Voltage Measurement System, T.O. 33K1-4-676-1 may be used as an alternate method to certify ESH( ) Model Electrostatic Voltmeters up to 10 kvdc or 30 kvac. 3.3 Use para 4.2 if TI has a meter and para 4.1 if TI does not have a meter. 3.4 If the item to be certified has an Analog Meter, it is necessary to zero before placing the item into the HV Measurement System cage. Change 10 1

3.5 This procedure is for certification of DCV only. If TI has ACV specifications that are required by the owner/user, a written request may be submitted to AFPSL, or use T.O. 33K1-4-676-1 as specified in NOTE under para 3.2. Attach a Limited Certification Label annotated DC ONLY if this procedure only, T.O. 33K1-4-1820-1, is used to certify a TI with ACV capabilities. For ESH( ) Model Electrostatic Voltmeters, if fully calibrated, annotate calibration label AC Volts T.O. 33K1-4-676-1, DC Volts T.O. 33K1-4-1820-1. 3.6 Use only that portion of the calibration process section and Calibration Performance Table (CPT) applicable to the TI being calibrated. 3.7 The High Voltage System output voltage is certified at 5 kv to 40 kvdc. If desired, an additional check may be made at 1 kvdc (if within TI specifications) using a DC Voltage Standard such as the Fluke 332D or 5440B. This is not required, but need only be performed as a confidence check. 4 CALIBRATION PROCESS: 4.1 PROBE CALIBRATION: WARNING Voltages hazardous to personnel may be encountered during the sequence of these test procedures. All necessary precautions during the conduct of these tests must be observed. When using the BRC-40-4-NA-1 High Voltage System, ensure ground lead on the rear panel of the power supply is connected to building ground to provide maximum protection against shock due to an ungrounded chassis. This ground stud should be connected to the low voltage end of the load. NOTE Unless otherwise specified, verify the results of each test and take corrective action whenever the test requirement is not met, before proceeding. CAUTION Unless otherwise specified in Appendix A, do not apply High Voltage any longer than is necessary to sequentially complete steps in the CPT. 4.1.1 Connect the Digital Multimeter to the KNOWN and UNKNOWN jacks on the HV Measurement System, observe polarity. 4.1.2 Select VDC on the Digital Multimeter. Select 10 V range for the KNOWN Digital Multimeter. Set the range as required on the UNKNOWN Digital Multimeter. If TI requires a specified impedance for maximum accuracy, as stated in Appendix A, ensure that the range selected for the UNKNOWN Digital Multimeter matches this impedance. WARNING Ensure that HIGH VOLTAGE indicator is not ON before opening the cage door on the HV Measurement System. Ensure that the voltage has been set to 00000. 4.1.3 Open the cage door on the HV Measurement System and connect the TI high voltage terminal to the HV Measurement System high voltage lead and the TI ground to the HV Measurement System ground lead. Connect TI OUTPUT to the UNKNOWN Digital Multimeter lead, observe polarity. Close the cage door on the HV Measurement System. 2 Change 10

4.1.4 On the HV Measurement System, set the ma ADJUST control to maximum and press HIGH VOLTAGE ON button. 4.1.5 Set the HV Measurement System HV ADJUST to the first applied value. 4.1.6 While monitoring the KNOWN Digital Multimeter, adjust the KV ADJUST until the KNOWN Digital Multimeter indication equals the applied value divided by 10000. 4.1.7 The indication on the UNKNOWN Digital Multimeter multiplied by Ratio of the TI must indicate within the corresponding values listed in the Limits column. 4.1.8 Repeat steps 4.1.5 through 4.1.7 for each remaining applied value. 4.1.9 Set FW Measurement System voltage to zero, press OFF RESET and disconnect all equipment. 4.2 METER CALIBRATION: CAUTION Unless otherwise specified in Appendix A do not apply High Voltage any longer than is necessary to sequentially complete steps in the CPT. 4.2.1 Connect the Digital Multimeter to the KNOWN jacks on the HV Measurement System, observe polarity. 4.2.2 Set Digital Multimeter to the 10 VDC range. WARNING Ensure that HIGH VOLTAGE indicator is not ON before opening the cage door on the HV Measurement System. Ensure that the voltage has been set to 00000. 4.2.3 Connect TI high voltage terminal to the HV Measurement System high voltage lead and the TI ground to the HV Measurement System ground lead. Place TI so that the meter can be seen through the cage door. Close the cage door on the HV Measurement System. 4.2.4 On the HV Measurement System, set the ma ADJUST control to maximum. 4.2.5 Set TI to first range indicated in the Range column (if applicable) and press HV ON button. 4.2.6 Set the HV Measurement System HV ADJUST to the first applied value. 4.2.7 While monitoring the TI, adjust the KV ADJUST until the TI or associated meter indicates the first applied value. 4.2.8 The indication on the KNOWN Digital Multimeter multiplied by 10000 must indicate within the corresponding values listed in the Limits column. 4.2.9 Repeat steps 4.2.5 through 4.2.8 for each remaining applied value. 4.2.10 Set HV Measurement System voltage to zero, press OFF RESET and disconnect and secure all equipment. Change 5 3

4.3 DIVIDER CALIBRATION: CAUTION Unless otherwise specified in Appendix A, do not apply High Voltage any longer than necessary to sequentially complete steps in the CPT. 4.3.1 Connect Digital Multimeter to the KNOWN and UNKNOWN on the HV Measurement System. 4.3.2 Set Digital Multimeter to the 10 VDC range. WARNING Ensure that HIGH VOLTAGE indicator is not ON before opening the cage door on the HV Measurement System. Ensure that the voltage has been set to 00000. 4.3.3 Open the cage door on the HV Measurement System, connect the TI high voltage terminal to the HV Measurement System high voltage lead and the TI ground to the HV Measurement System ground lead. Connect TI OUTPUT or TAP to be certified to the UNKNOWN Digital Multimeter lead, observe polarity. Close the cage door on the HV Measurement System. 4.3.4 On the HV Measurement System, set the ma ADJUST control to maximum and press HIGH VOLTAGE ON button. 4.3.5 Set the HV Measurement System HV ADJUST to the first applied value. 4.3.6 While monitoring the KNOWN Digital Multimeter, adjust the KV ADJUST until the KNOWN Digital Multimeter indication equals the applied value divided by 10000. 4.3.7 The indication on the UNKNOWN Digital Multimeter multiplied by the Ratio of the TI must indicate within the corresponding values listed in the Limits column. 4.3.8 Repeat steps 4.3.3 through 4.3.7 for each TI OUTPUT or TAP to be certified. 4.3.9 Set HV Measurement System voltage to zero, press OFF RESET and disconnect and secure all equipment. Set HV Measurement System voltage to zero, press OFF RESET and disconnect and secure all equipment. 4 Change 5

APPENDIX A HIGH VOLTAGE INSTRUMENTS Table A-1. SPECIFICATIONS AND S LISTING Part Number Page Part Number Page Part Number Page DVM-1 (Digital)... A-41 D102H... A-2 ESH ( )... A-3 HVP-40... A-5 HV-2... A-6 HV231-22... A-7 HV40... A-8 HV40B... A-9 HV 40C... A-10 IM5210... A-11 LHM-80B... A-12 MARK-IV... A-42 MARKV... A-43 N2771A... A-37 PM9246... A-13 PR-28... A-14 PR28... A-14 PR28A... A-35 VD60-12.5-B... A-39 VD60-6.2-A... A-39 VD60-6.2-B... A-39 V41A/V40A... A-15 00033... A-16 00034... A-17 00749... A-18 10800BC... A-19 12100... A-20 12500... A-21 139D... A-40 1600A... A-22 248... A-23 2900... A-36 2900A... A-36 34111A... A-24 34119A... A-25 34136A... A-38 382846... A-26 80E10... A-27 80E5... A-28 80F15 ( )... A-29 80F5... A-30 80K30... A-31 80K40... A-32 80K-40-5... A-33 80K6... A-34 Change 10 A-1

APPENDIX A SPECIFICATIONS AND S D102H (W.H. ASSOCIATES/MEDISTOR) HV DIVIDER RANGE: 5 kvdc OUTPUT TAPS: Accuracy: ±0.01% Stability: ±0.01% FRONT PANEL METER: Not specified, for approximate magnitude indications only. Tap 1 V 5 k 4990 to 5010 10 V 5 k 4990 to 5010 NOTE Attach a Limited Certification Label annotated with Accuracy ±0.2% A-2 Change 4

ESH ( ) (SENSITIVE RESEARCH, SINGER, SR ENGINEERING) ELECTROSTATIC VOLTMETER 0 to 40 kvdc/ac, ±1% FS, ±0.5% FS NOTE Use ±0.5% FS limits if TI P/N ends with X. Use ±1% FS limits for all others. Range * (±1% FS) (±0.5% of FS) 5000 5 k 4950 to 5050 4975 to 5025 7500 5 k 4925 to 5075 4962 to 5038 6 k 5925 to 6075 5962 to 6038 7.5 k 7425 to 7575 7462 to 7538 10000 5 k 4900 to 5100 4950 to 5050 7 k 6900 to 7100 6950 to 7050 10 k 9900 to 10100 9950 to 10050 15000 5 k 4850 to 5150 4925 to 5075 10 k 9850 to 10150 9925 to 10075 15 k 14850 to 15150 14925 to 15075 20000 5 k 4800 to 5200 4900 to 5100 10 k 9800 to 10200 9900 to 10100 15 k 14800 to 15200 14900 to 15100 20 k 19800 to 20200 19900 to 20100 25000 5 k 4750 to 5250 4875 to 5125 10 k 9750 to 10250 9875 to 10125 15 k 14750 to 15250 14875 to 15125 20 k 19750 to 20250 19875 to 20125 See footnote at end of Table. A-3

(Cont.) Range * (±1% FS) (±0.5% of FS) 25000 25 k 24750 to 25250 24875 to 25125 30000 10 k 29700 to 30300 29850 to 30150 20 k 19700 to 20300 19850 to 20150 30 k 29700 to 30300 29850 to 30150 40000 5 k 4600 to 5400 4800 to 5200 10 k 9600 to 10400 9800 to 10200 20 k 19600 to 20400 19800 to 20200 30 k 29600 to 30400 29800 to 30200 40 k 39600 to 40400 39800 to 40200 * Use ranges that apply to the TI being calibrated. A-4

HVP-40 (PINTEK) HV PROBE ±1% at 1 to 20 kvdc ±2% at 20 to 40 kvdc Use with 10 M Ohm Input Voltmeter 5 k 4950 to 5050 10 k 9900 to 10100 20 k 19800 to 20200 25 k 24500 to 25500 30 k 29400 to 30600 35 k 34300 to 35700 40 k 39200 to 40800 Change 1 A-5

HV-2 (VALHALLA) HV PROBE Up to 40 kvdc, ±2% FS Use with 10 Megohm Input Voltmeter 10 k 9200 to 10800 15 k 14200 to 15800 20 k 19200 to 20800 25 k 24200 to 25800 30 k 29200 to 30800 35 k 34200 to 35800 40 k 39200 to 40800 A-6

HV231-22 (BECKMAN) HV PROBE Up to 40 kvdc, ±2% Use with 22 MΩ Input Impedance Voltmeter NOTE Owner must supply the meter with which the TI will be used or a meter with 22 MΩ input impedance and a DCV accuracy of at least 0.5% may be substituted for the UNKNOWN Voltmeter. 5 k 4900 to 5100 10 k 9800 to 10200 20 k 19600 to 20400 30 k 29400 to 30600 40 k 39200 to 40800 A-7

HV40 (B & K PRECISION) HV PROBE ±2% at 25 kvdc ±4% at 1 to 20 kvdc and 30 to 40 kvdc 5 k 4800 to 5200 10 k 9600 to 10400 20 k 19200 to 20800 25 k 24500 to 25500 30 k 28800 to 31200 35 k 33600 to 36400 40 k 38400 to 41600 A-8

HV40B (COLINE LTD) HV PROBE ±2% at 0 to 40 kv, DC to 300 Hz Use with 10 Megohm Input Voltmeter 5 k 4900 to 5100 10 k 9800 to 10200 20 k 19600 to 20400 25 k 24500 to 25500 30 k 29400 to 30600 35 k 34300 to 35700 40 k 39200 to 40800 Change 8 A-9

HV 40C (Test Probes Inc.) HV Probe ±1% 1 to 20 kvdc ±2% 20 to 40 kvdc Use with 10 Megohm Input Voltmeter DC 5 k 4950 to 5050 10 k 9900 to 10100 20 k 19600 to 20400 25 k 24500 to 25500 30 k 29400 to 30600 35 k 34300 to 35700 40 k 39200 to 40800 A-10

IM5210 (HEATH) HV PROBE ±3% FS, 0 to 40 kvdc 5 k 3800 to 6200 10 k 8800 to 11200 15 k 13800 to 16200 20 k 18800 to 21200 25 k 23800 to 26200 30 k 28800 to 31200 35 k 33800 to 36200 40 k 38800 to 41200 A-11

LHM-80B (LEADER) HV METER PROBE ±0 to 40 kvdc, ±3% FS 5 k 3800 to 6200 10 k 8800 to 11200 15 k 13800 to 16200 20 k 18800 to 21200 25 k 23800 to 26200 30 k 28800 to 31200 35 k 33800 to 36200 38 k 36800 to 39200 A-12

PM9246 (PHILLIPS) HV PROBE ±2%, 30 kvdc Max Input Impedance set to 10 Megohm 5 k 4900 to 5100 10 k 9800 to 10200 15 k 14700 to 15300 20 k 19600 to 20400 25 k 24500 to 25500 30 k 29400 to 30600 A-13

PR-28 (B & K PRECISION) & PR28 (DYNASCAN CORP) HV PROBE ±3% of output at 1 to 40 kvdc; ±5% of output at 1 to 20 kvac, 50/60 Hz Use with 10 Megohm Input Impedance Voltmeter 5 k 4850 to 5150 10 k 9700 to 10300 15 k 14550 to 15450 20 k 19400 to 20600 25 k 24250 to 25750 30 k 29100 to 30900 35 k 33950 to 36050 40 k 38800 to 41200 A-14 Change 6

V41A/V40A (DATA PRECISION) HIGH VOLTAGE PROBE ±2% at 20 kvdc ±4% at 1 to 2 kvdc and 30 to 40 kvdc Use with 10 Megohm Input Voltmeter 5 k 4815 to 5185 10 k 9690 to 10310 15 k 14450 to 15550 20 k 19600 to 20400 30 k 28800 to 31200 35 k 33600 to 36400 40 k 38400 to 41600 A-15

00033 (SIMPSON) HV PROBE ±2% FS, 0 to 40 kvdc NOTE Before proceeding, connect a 50 kω, 1 watt, 0.5% resistor across the INPUT of the UNKNOWN Digital Multimeter. Division Ratio 20000:1. 5 k 4200 to 5800 10 k 9200 to 10800 15 k 14200 to 15800 20 k 19200 to 20800 25 k 24200 to 25800 30 k 29200 to 30800 35 k 34200 to 35800 40 k 39200 to 40800 A-16

00034 (SIMPSON) HV PROBE ±2% FS, 0 to 10 kvdc NOTE Before proceeding, connect a 50 kω, 1/2 watt, 0.5% resistor across the input of the UNKNOWN Digital Multimeter. Multiply UNKNOWN Digital Multimeter indication by 4000 to obtain reading for Limits. 5 k 4800 to 5200 6 k 5800 to 6200 7 k 6800 to 7200 8 k 7800 to 8200 9 k 8800 to 9200 10 k 9800 to 10200 A-17

00749 (SIMPSON) HV PROBE ±2% FS, 0 to 40 kvdc Use with 10 Megohm Input Voltmeter 5 k 4200 to 5800 10 k 9200 to 10800 15 k 14200 to 15800 20 k 19200 to 20800 25 k 24200 to 25800 30 k 29200 to 30800 35 k 34200 to 35800 40 k 39200 to 40800 A-18

10800BC (BALLANTINE) HV PROBE ±4% at 1 and 40 kvdc ±3% at 10 kvdc ±2% 20 and 30 kvdc ±1% at 25 kvdc Use with 10 Megohm Input Voltmeter 10 k 9700 to 10300 20 k 19600 to 20400 25 k 24750 to 25250 30 k 29400 to 30600 40 k 38400 to 41600 A-19

12100 (JENNINGS) KILOVOLTMETER DC and AC PK 0 to 10 kv, 0 to 50 kv; AC rms 1 to 10 kv, 2 to 35 kv; ±1% FS ±1 Digit Range (VDC) 10 k 5 k 4890 to 5110 9 k 8890 to 9110 50 k 10 k 9400 to 10600 20 k 19400 to 20600 22 k 21400 to 22600 24 k 23400 to 24600 26 k 25400 to 26600 28 k 27400 to 28600 30 k 29400 to 30600 35 k 34400 to 35600 40 k 39400 to 40600 A-20

12500 (JENNINGS) KILOVOLTMETER DC and AC rms 2 to 20 kv, ±(1% Rdg + 0.1% FS + 1 Digit); 5 to 50 kv, ±(1% Rdg + 0.1% FS + 1 Digit) Range (VDC) 20 k 5 k 4920 to 5080 10 k 9870 to 10130 15 k 14820 to 15180 19 k 18780 to 19220 50 k 5 k 4800 to 5200 10 k 9700 to 10300 20 k 19600 to 20400 22 k 21600 to 22400 24 k 23600 to 24400 26 k 25600 to 26400 28 k 27600 to 28400 30 k 29500 to 30500 35 k 34500 to 35500 40 k 39400 to 40600 Change 5 A-21

1600A (KEITHLEY) HV PROBE ±2% at 1 to 40 kvdc Use with 10 Megohm Input Voltmeter 5 k 4900 to 5100 10 k 9800 to 10200 15 k 14700 to 15300 20 k 19600 to 20400 25 k 24500 to 25500 30 k 29400 to 30600 35 k 34300 to 35700 40 k 39200 to 40800 A-22

248 (SIMPSON) HV PROBE ±3% up to 40 kvdc 5 k 4850 to 5150 10 k 9700 to 10300 15 k 14550 to 15450 20 k 19400 to 20600 25 k 24250 to 25750 30 k 29100 to 30900 35 k 33950 to 36050 A-23

34111A (HEWLETT-PACKARD) HV PROBE Less than; ±2% at 20 to 30 kvdc Less than; ±4% at 0 to 20 kvdc and 30 to 40 kvdc Use with 10 Megohm Input Voltmeter 5 k 4800 to 5200 10 k 9600 to 10400 15 k 14400 to 15600 22 k 21560 to 22440 25 k 24500 to 25500 28 k 27440 to 28560 35 k 33600 to 36400 40 k 38400 to 41600 A-24

34119A (HEWLETT-PACKARD) HV PROBE ±1.5% 0 to 5 kvdc; ±1.5% 0 to 5 kvac @ <100 khz; ±2.5% 0 to 5 kvac @ 100 khz to 250 khz; ±2.5% 0 to 2.5 kvac @ 250 khz to 1 MHz Use with 10 Megohm input meter for DC and 1 Megohm input meter for AC 5 k 4925 to 5075 A-25

382846 (FLUKE) HV PROBE ±1% at 25 kvdc; ±2% at 20 to 30 kvdc; ±5% up to 28 kvac @ 60 Hz Changes Linearly from; ±4% at 1 kvdc to ±2% at 20 kvdc and ±2% at 30 kvdc to ±4% at 40 kvdc Use with 10 Megohm Input Voltmeter 5 k 4825 to 5175 10 k 9700 to 10300 20 k 19600 to 20400 25 k 24750 to 25250 30 k 29400 to 30600 35 k 33950 to 36050 40 k 38400 to 41600 A-26

80E10 (FLUKE) HV DIVIDER Range: 10 kvdc OUTPUT TAPS: Accuracy: ±0.01% Stability: ±0.01% FRONT PANEL METER: Not specified, for approximate magnitude indications only. NOTE Full input voltage should be applied for a minimum of 30 minutes prior to calibration. Tap 1 V 5 k 4990 to 5010 10 k 9980 to 1020 10 V 5 k 4990 to 5010 10 k 9980 to 10020 NOTE Attach a Limited Certification Label annotated with Accuracy ±0.2%. A-27

80E5 (FLUKE) HV DIVIDER Range: 5 kvdc OUTPUT TAPS: Accuracy: ±0.01% Stability: ±0.01% FRONT PANEL METER: Not specified, for approximate magnitude indications only. NOTE Full input voltage should be applied for a minimum of 30 minutes prior to calibration. Tap 1 V 5 k 4990 to 5010 10 V 5 k 4990 to 5010 NOTE Attach a Limited Certification Label annotated with Accuracy ±0.2%. A-28

80F15( ) (FLUKE) HV PROBE 1 kv to 15 kvdc, ±0.05% NOTE Ensure that input impedance of multimeter matches the value marked on TI divider box. Attach a Limited Certification Label annotated with Accuracy ±0.2%. 5 k 4990 to 5010 10 k 9980 to 10020 15 k 14970 to 15030 A-29

80F5 (FLUKE) HV PROBE Accuracy: ±0.05% 5 k 4990 to 5010 NOTE Attach a Limited Certification Label annotated with Accuracy ±0.2%. A-30

80K30 (FLUKE) HV PROBE ±1% at 15 kvdc Changes Linearly to 4% at 1 kvdc and 30 kvdc ±5% to 21 kvac, 60 Hz Use with 10 Megohm Input Voltmeter 5 k 4800 to 5200 10 k 9750 to 10250 15 k 14850 to 15150 20 k 19530 to 20470 25 k 24075 to 25925 30 k 28800 to 31200 A-31

80K40 (FLUKE) HV PROBE NOTE The 80K40 HV Probe may have one of at least three different sets of known Comm Data specifications depending upon when it was manufactured. Please refer to the specifications that came with the probe and match it to the correct specifications. Use applicable Limits column listed below. If specifications do not accompany the probe, or are not available from the User, please calibrate the TI to the first set of specifications below. If the TI does not meet these specifications, calibrate to the second or third set of specifications and place an appropriate Limited Certification Label on the probe. If this is unacceptable to the User, a second option is to return the probe to the User and have them upgrade it to the latest specifications by purchasing an upgrade kit from Fluke Corp., or by sending the probe to Fluke Corp. for upgrade. After this upgrade, the probe should meet the first set of specifications. In all situations, annotate the Certification Label or Limited Certification Label, as appropriate, with the accuracy TI is calibrated to. *¹ ±1%, 20 to 35 kv DC at 20 to 30 C add 1% at 10 C to <20 and >30 to 45 C; ±2%, 0 to <20 and >35 to 40 kv DC; ±5% @ 60 Hz, up to 28 kv AC rms Use with 10 Megohm Input Voltmeter *² ±1%, 20 to 30 kv DC Changes linearly from: ±1% at 30 kv DC to 2% at 40 kv DC and ±1% at 20 kv DC to 2% at 1 kv DC; ±5% @ 60 Hz, up to 28 kv AC rms Use with 10 Megohm Input Voltmeter *³ ±2%, 20 to 30 kv DC; Changes linearly from: ±2% at 30 kv DC to 4% at 40 kv DC and ±2% at 20 kv DC to 4% at 1 kv DC; ±5% @ 60 Hz, up to 28 kv AC rms Use with 10 Megohm Input Voltmeter *¹ *² *³ 5 k 4900 to 5100 4910 to 5090 4821 to 5179 10 k 9800 to 10200 9847 to 10153 9695 to 10305 20 k 19800 to 20200 19800 to 20200 19600 to 20400 25 k 24750 to 25250 24750 to 25250 24500 to 25500 30 k 29700 to 30300 29700 to 30300 29400 to 30600 35 k 34650 to 35350 34475 to 35525 33950 to 36050 40 k 39200 to 40800 39200 to 40800 38400 to 41600 A-32 Change 6

80K-40-5 (FLUKE) HV PROBE ±2% at 1 to 5 kvdc ±5% at 1 to 5 kvac @ 60 Hz 5 k 4900 to 5100 A-33

80K6 (FLUKE) HV PROBE ±1% at 0 to 6 kv, DC to 500 Hz Use with 10 Megohm Input Voltmeter 5 k 4950 to 5050 6 k 5940 to 6060 A-34

PR28A (B & K PRECISION) HV PROBE ±3% of output at 1 to 40 kvdc; ±5% of output at 1 to 28 kvac, 50/60 Hz Use with 10 Megohm Input Impedance Voltmeter 5 k 4850 to 5150 10 k 9700 to 10300 15 k 14550 to 15450 20 k 19400 to 20600 25 k 24250 to 25750 30 k 29100 to 30900 35 k 33950 to 36050 40 k 38800 to 41200 Change 2 A-35

2900, 2900A (POMONA) HV PROBE ±3% of FS at 0 to 30 kvdc 5 k 4100 to 5900 10 k 9100 to 10900 15 k 14100 to 15900 20 k 19100 to 20900 25 k 24100 to 25900 30 k 29100 to 30900 A-36 Change 3

N2771A (AGILENT) HV PROBE * ±2% rdg at 0 to 15 kvdc ±2% rdg at 1 khz VAC Use with 1 Megohm Input Voltmeter 5 k 4900 to 5100 10 k 9800 to 10200 15 k 14700 to 15300 * See step 3.5. Change 6 A-37

34136A (AGILENT) HV PROBE * ±2% of rdg at 1 to 20 kvdc ±3% of rdg at 20 to 40 kvdc ±5% of rdg to 28 kvac @ 60 Hz Use with 10 Megohm Input Voltmeter Applied (kvdc) 5 4900 to 5100 10 9800 to 10200 15 14700 to 15300 20 19600 to 20400 25 24250 to 25750 30 29100 to 30900 35 33950 to 36050 40 38800 to 41200 * See step 3.5. A-38 Change 7

VD60 SERIES (ROSS ENGINEERING CORP) HV DIVIDERS VD60-12.5B, VD60-6.2-A, VD60-6.2-B * ±0.1% of rdg at 0 to 60 kvdc ±0.5% of rdg to 60 kvac p @ 60 Hz Applied (kvdc) 5 4995 to 5005 10 9990 to 10010 15 14985 to 15015 20 19980 to 20020 25 24975 to 25025 30 29970 to 30030 35 34965 to 35035 40 39960 to 40040 * See step 3.5. NOTE Attach a Limited Certification Label annotated with Accuracy ±0.2%. Change 7 A-39

139D (BRANDENBURG) HIGH VOLTAGE METER 0 to ±40 kvdc; ±(0.25% of rdg @ 20 kv + 0.025%/kV < or > 20 kv) Range) 20 kv 6 k 5964 to 6036 12 k 11946 to 12054 19 k 18948 to 19052 40 kv 13 k 12945 to 13055 20 k 19950 to 20050 26 k 25896 to 26104 39 k 38717 to 39283 A-40 Change 8

DVM-1 (HD ELECTRIC COMPANY) VOLTMETER/PHASER 0 to ±20 kv DC/AC, (DC to 1000 Hz) ±(2% of rdg + 3 dgts) Applied (kvdc) 6 5850 to 6150 14 13690 to 14310 18 17610 to 18390 Change 9 A-41

* Hotsticks Required MARK-IV (HD ELECTRIC COMPANY) VOLTMETER/PHASER ±3% of FS at 0 to ±5 kv DC * ±3% of FS at 0 to 5 kv AC at 50/60 Hz * Range (kv DC) Applied (kv DC) 5 5 4850 to 5150 A-42 Change 10

* Hotsticks Required MARKV (HD ELECTRIC COMPANY) VOLTMETER/PHASER ±3% of FS at 0 to ±15 kv DC * ±3% of FS at 0 to 15 kv AC at 50/60 Hz * Range (kv DC) Applied (kv DC) 5 5 4850 to 5150 15 5 4550 to 5450 10 9550 to 10450 15 14550 to 15450 Change 10 A-43/(A-44 Blank)