Desalting using ÄKTA start

Similar documents
New Amersham Hyperfilm

Cytell Cell Imaging System

LOABeads AffiAmino. Product Manual. Lab on a Bead AB. Revision date Copyright Lab on a Bead AB All rights reserved

LOABeads Protein A. Product no Product Manual. Lab on a Bead AB

Column Chromatography System

NGC Chromatography Systems

Amersham Amplify Fluorographic Reagent

AffiAmino UltraRapid Agarose

Flash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility

M-Beads Magnetic Silica Beads WAX

Technical Manual No. TM0261 Version

High Capacity Magne Streptavidin Beads

MicroLab 500-series Getting Started

IN Cell Analyzer 6500HS

New core bead medium enables group separation and high productivity IgM purification

Bead Injection. MicroSI Chromatography on Renewable Column FLOWCELL MPV

30 Plex Human Luminex (Invitrogen Kit, Single Plate)

IN Cell Analyzer 2000

2.0. NGC Fraction Collector Instrument Guide Version 2.0

LOABeads MagSep 15/50 LOABeads MagSep 500

Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads. Product Numbers: RPNQ0096

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit

BD FC Beads 7-Color Kit

Sodium Thiosulphate and hydrochloric acid

Strep-tag Purification using MagStrep type3 XT Beads

LC/MS Purification System TRILUTION LC v3.0 User s Guide

Strep-tag Purification using MagStrep type3 XT Beads

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

TrueBlot Protein G Magnetic Beads PG ml. TrueBlot Protein G Magnetic Beads PG ml. Bead Mean Diameter 0.5 µm. Bead Concentration

SOP-P094. BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis

Strep-tag Purification using MagStrep type3 XT Beads

Recording EPR spectra using the Loop Gap Resonator (LGR)

When to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules

FC 203B Fraction Collector. Quick Reference Guide

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Rev F 8/30/ O Neil Rd, Macedon NY Telephone: (315) Fax: (315)

Downloaded from:

308940J INSTRUCTIONS-PARTS LIST. Kit, Beads Dispenser WARNING. Pressure Relief Procedure ENG GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN

Nexera Method Scouting

BD FC Beads 7-Color Kit

Formaldehyde Cross-linking of Chromatin from Drosophila

Determining the Dynamic Characteristics of a Process

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field.

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit

GE AMX 4+ Portable X-Ray

GPS Position Sensor PS-2175

Gradient Programmer GP-250 Plus

ImageScanner III LabScan 6.0

DPM Kit DK-1. Using the DPM Kit

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol

Uytengsu Teaching Lab Consumable Inventory

RayBio anti-mouse IgG Magnetic Beads

Discover and enjoy Fast Flash purifications offered by EasyVarioFlash cartridges!

Minimizing purification time with high resolution flash chromatography

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

DeltaVision OMX SR. DeltaVision OMX SR microscope. gelifesciences.com

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Top Support Kit: (x2) - 2 Top Supports. Quantities are per bench

PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract

Determining the Dynamic Characteristics of a Process

BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012

New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03. Technical Note.

pluribead KIT Cell Separation Protocol M-Bead

Epson SureColor P5000. Quick Reference

HYDRO-TOWER INSTALLATION INSTRUCTIONS

MANUAL FOR DIRECT PRINTING

Start Here. Installing your Microtek ScanMaker i280

Installing the detector filter assembly (G )

Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads

The Virgo/Libra Steam Engine

Game Specifications. Size: 93 (2362 mm) D x 43 (1100 mm) W x 83 (2112 mm) H Weight: 661 lbs. (300 kg) Power: 1200 W. light box. Speaker box 42 LCD

Instructions & Parts SM100B SM400 K025S1 K005

GE Healthcare. Senographe Crystal The choice is crystal clear

Problem-free economical and safe use of bulk materials

V-GES operation. Technical Bulletin E-02 MATERIAL PROCEDURE

T. REX. Assembly Instructions Model 2: Real Action T. REX. Model 4: Biped Walking Robot. Get instructions for even more robots!

FITTINGS & GAUGES 20,000 PSI

Owner s Manual #TSGUARD

Basic Troubleshooting Guide Media Mogul and Apprentice Machines

Energate Foundation Meter Data Collector Installation Guide

OFFICICAL COPY. VeraCode TM and BeadXpress TM Equipment, Materials, and Reagents Checklist

Aluminum Frame Type Instruction Manual

Assay development (biochemical protein-protein interaction assays)

P R O D U C T I N S E R T

ISOFECAL for Beads Beating Manual (First edition)

Electronic Supplementary Information (ESI) Photoenzymatic Synthesis through Sustainable NADH Regeneration by SiO 2 - Supported Quantum Dots

OPTISENS PH 8100 Technical Datasheet

Agilent 1200 Infinity Series

Ultraclean Flow Measurement!

Dremel 3D Printer Digital Fabrication Lab College of Design, Iowa State University

Density-Based Diamagnetic Separation: Devices for Detecting Binding Events and for

FOCUSED INNOVATIONS IN LIFE SCIENCES

ph or ORP Transmitter

Purchase Guide STANDARD AP * CHEMISTRY LABORATORY SUPPLIES SCIENTIFIC. from. P.O. Box 219 Batavia, IL (800) Fax (866)

Signet 9900 Transmitter

Table of contents. User interface 1: Customizable tool palette... 6 User interface 2: General GUI improvements... 7

UNDERPINNERS CS 88 & CS 89 FOOT-OPERATED PNEUMATIC. Technical and User Manual. Version 1 au 12 / 01. Cassese / Communication

Metzger Lab Protocol Book Written by Pierre Coutu 08/06/2003. Ionoptix Procedure

Signet 9900 Transmitter

Transcription:

GE Healthcare Life Sciences Desalting using ÄKTA start Training cue card This protocol will help you understand the practical principles of desalting chromatography by taking you step-by-step through the desalting of Bovine Serum Albumin (BSA). Requirements ÄKTA start system Frac30 fraction collector Desalting Buffer (DS buffer): 25 mm sodium phosphate, 150 mm NaCl, ph 7.5 (Prepare at least 200 ml of buffer) Sample: BSA 1 mg/ml in 25 mm sodium phosphate buffer, 0.5 M NaCl, ph 7.5. (Prepare 5 ml of sample) Column: HiTrap Desalting 5 ml Fraction tubes: 1.5 ml microcentrifuge tubes 1 ml Sample loop USB 2.0 memory stick Checklist Ensure the Frac30 fraction collector is connected to the ÄKTA start instrument. Ensure the pump tube is properly inserted in the pump head and the pump cover is closed properly. Ensure there is no column connected in the flow path while preparing the system for a run. If the system or column is stored in ethanol, wash with water prior to starting the run. Preparing the system 1. Place the bottle containing the DS buffer in the buffer tray on top of the instrument. 2. Immerse buffer inlet A in the bottle containing DS buffer. 3. Place the waste bottle on the right side of the instrument. Note: The waste tubing (from Wash valve, Manual injection valve and Outlet valve) should be inserted into the waste bottle as shown in Figure 1. Fig 1. ÄKTA start instrument with Frac30 fraction collector. 4. Power ON the ÄKTA start instrument. Note: Enable Frac30 from the Fraction collector screen in the Settings and service screen menu, if not previously enabled. 5. Prime the entire flow path (buffer tubing to fractionation tubing) with DS buffer to ensure the tubing is filled with DS buffer before starting the chromatography run. Perform Washout fractionation tubing: a. Place the fractionation tubing in the waste bottle. b. From ÄKTA start instrument display home screen (Fig 2), tap Method run. Fig 2. ÄKTA start display: Screenshot of the main menu. 29-1094-91 AA 1

c. From Method run screen, tap Prepare system. d. Select Washout fractionation tubing (Fig 3). e. Select the run parameters. Tap Run to initiate the method. Connecting the column Connect the HiTrap Desalting 5 ml column to the system (Fig 5). To avoid introducing air into the column, connect the column drop to drop. 7. Attach a column clamp to the column holder rail on the instrument. 8. Remove the column stoppers and mount the column on the union connector. 9. Fix the column to the column clamp. Fig 5. Image showing the column position. Fig 3. ÄKTA start display: Screenshots of the Prepare system methods, Select parameters, and Fractionation wash run screens. 6. Prepare Frac30 fraction collector (Fig 4A). a. Fill the inner row of holders with 1.5 ml microcentrifuge tubes (Fig 4B). b. Move the dispenser arm to the dispensing position. c. Insert the fractionation tubing into the tubing holder. 10. Remove the G5 tubing from the union connector (Manual injection valve to the top/inlet of the column). 11. Start a manual run with 0.5 ml/min flow rate. Wait for the buffer to flow continuously from the tubing labeled G5 and then start filling the top part of the column with the buffer. When the top part of the column is filled with the buffer, connect the tubing to the top part of the column. 12. Connect the G6 tubing (column outlet to UV) to the bottom of the column holder/union connector. Loading sample 13. Ensure that the 1 ml sample loop is connected to the Manual injection valve (ports 2 and 5). 14. Ensure the Manual injection valve is in LOAD position, as illustrated in Figure 6. Wash the sample loop with 5 ml DS buffer with a syringe (through port 3 of the Manual injection valve). (A) (B) Fig 4. Frac30 fraction collector with collection tubes. A) Frac30 fraction collector. B) Fraction collector showing placement of the microcentrifuge tubes. Fig 6. Image showing Manual injection valve in LOAD position and sample loop attached to ports 2 and 5. 2 29-1094-91 AA

15. Pre-fill the loop with 1.5 ml sample (port 3). Note: In order to avoid sample drainage do not remove the syringe until the sample is loaded onto the column It is recommended to overload the loop with higher sample volume to make sure the loop is completely filled Starting the run 16. Insert a USB memory stick in the USB port of the instrument. Note: The result files will be saved in the GE folder which is automatically created by the instrument once the USB memory stick is plugged in. 17. From ÄKTA start instrument display home screen, tap Method run. 18. From the Method run screen, tap Templates (Fig 7). Fig 9. ÄKTA start display: Screenshot of Run parameters screen (2/3). 24. Select sample from Loop. 25. Enter Sample volume = 1 ml. 26. Enter Equilibration volume = 3 CV. Tap the forward arrow to go to screen (3/3) (Fig 10). Fig 7. ÄKTA start display: Screenshot of the Templates screen. 19. Select Desalting/Buffer exchange, and tap Select. 20. The following run parameter screen (1/3) appears (Fig 8). Fig 10. ÄKTA start display: Screenshot of Run parameters screen (3/3). 27. Enter Fractionation volume = 1 ml. 28. Tap Run to start the run (Fig 9) Note: While the run is in progress, the real time UV curve can be observed by tapping on the graph icon. The run view screen also displays other real-time run parameters such as conductivity, pressure, flow rate, and tube number (Fig 11). Fig 8. ÄKTA start display: Screenshot of Run parameters screen (1/3). 21. Tick the Save Result to USB check box. 22. Provide a result file name (e.g. DS04). Only the two digits of the result file name can be modified. 23. Tap the forward arrow to go to screen (2/3) (Fig 9). Fig 11. ÄKTA start display: Screenshot of Run view and real time graph screens. 29-1094-91 AA 3

During the run 29. When prompted on the screen (as depicted below in Fig 12), manually turn the injection valve to INJECT position. Note: The system is in hold state while injecting the sample from loop. To ensure that the injection mark coincides with the injection event, acknowledge the message immediately after the action is performed. Typical result 36. Insert the USB memory stick into a computer to open the chromatography result file (DS01) in any image viewing software (Microsoft picture manager/ paint etc.). A representative chromatogram for the chromatography run is shown in Figure 14. Fig 12. ÄKTA start display: Screenshot of Sample inject message screen. 30. After manually switching the position, acknowledge the message by tapping Continue (Fig 12). The sample is injected from the loop on to the column. 31. After 1 ml of sample has been injected, a prompt appears on the screen (depicted below in Fig 13). Fig 13. ÄKTA start display: Screenshot of Sample inject message screen prompt following sample injection. 32. Manually turn the injection valve to LOAD position. 33. After manually switching position, acknowledge the message by tapping Continue (Fig 13). 34. After the completion of the run tap Exit. 35. Remove the USB memory stick from the ÄKTA start instrument. Fig 14. Chromatogram (.bmp image) of desalting on ÄKTA start. Troubleshooting High back pressure Column clogged: Clean the column according to instructions. Make sure the sample has been centrifuged and/or filtered through a 0.45 μm filter. System clogged: Replace the column with a piece of tubing. Check pressure using water at a flow rate of 5 ml/min. If backpressure is more than 0.3 MPa (3 bar, 43.5 psi), clean system according to instructions in manual. No separation Check that the correct column is used. Check that the inlet tubing from each buffer is connected to the correct inlet port. Check that the composition and ph of the buffers are correct. Check that the sample contains target protein. System maintenance and storage For detailed description of maintenance and storage see ÄKTA start operating instructions. Storage of column For detailed description of column storage see HiTrap Desalting column instructions. 4 29-1094-91 AA

Check your knowledge Q1: Where should the Desalting buffer be placed? a. Under the ÄKTA start instrument b. On the bench c. On the buffer tray Q2: How can you load your sample on the column using ÄKTA start? a. Via the pump b. Via a sample loop c. All of the above Q3: Why is it recommended to overload the sample loop? a. To load more sample volume in the sample loop b. To make sure that the capillary loop is completely filled c. All of the above Q4: Why should the Sample inject message be acknowledged as soon as the Manual injection valve has been manually turned? a. To ensure that the injection mark coincides with the injection event b. To ensure that the injection of sample is performed c. All of the above Q5: Why should the column be connected to the ÄKTA start instrument using drop-to-drop? a. To equilibrate the column faster b. To avoid introducing air into the column c. To remove the storage solution Q6: What can be viewed in the Run view screen? a. Real-time UV absorbance and conductivity b. Real-time tube number c. Real-time flow rate and pressure d. Chromatogram e. All of the above Q7: Where can the result file be found after the run is completed? a. On the USB stick b. On the display c. There is no result file 29-1094-91 AA 5

Answers Q1. C Q2. C Q3. B Q4. A Q5. B Q6. E Q7. A Ordering information Product Quantity Code number HiTrap Desalting 1 5 ml 29-0486-84 HiTrap Desalting 5 5 ml 17-1408-01 Sample Loop 1 ml 1 1 ml 18-1114-01 Column Clamp 1 28-9563-19 Union 1/16 female-1/16 female 1 11-0003-39 Reference information Document Code number ÄKTA start System cue card 29-0240-42 ÄKTA start Maintenance cue card 29-0240-43 ÄKTA start Operating instructions 29-0270-57 HiTrap Desalting instructions 71-7154-00 Related literature Product Code number Application notes Purification of N-terminal histidine-tagged protein using ÄKTA start 29-0642-77 Purification of GST-tagged protein using ÄKTA start 29-0642-98 Purification of antibodies using ÄKTA start and HiTrap Protein G HP column 29-0643-02 Depletion of albumin from serum samples using ÄKTA start 29-0642-95 Training cue cards Gel filtration using ÄKTA start 29-1120-91 Affinity purification using ÄKTA start 29-1150-58 Anion exchange purification using ÄKTA start 29-1107-59 6 29-1094-91 AA

29-1094-91 AA 7

For local office contact information, visit www.gelifesciences.com/contact www.gelifesciences.com/akta GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden imagination at work GE, GE monogram, and imagination at work are trademarks of General Electric Company. ÄKTA and HiTrap are trademarks of General Electric Company or one of its subsidiaries. Microsoft is a registered trademark of Microsoft Corporation. All other third party trademarks are the property of their respective owner. 2014 General Electric Company All rights reserved. First published Jul. 2014 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. GE Healthcare UK Limited Amersham Place Little Chalfont Buckinghamshire, HP7 9NA UK GE Healthcare Europe, GmbH Munzinger Strasse 5 D-79111 Freiburg Germany GE Healthcare Bio-Sciences Corp. 800 Centennial Avenue, P.O. Box 1327 Piscataway, NJ 08855-1327 USA GE Healthcare Japan Corporation Sanken Bldg., 3-25-1, Hyakunincho Shinjuku-ku, Tokyo 169-0073 Japan 29-1094-91 AA 07/2014