PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION

S40A Three-Phase Relay Tester

PCT200 Series User Manual

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

SVERKER 900 Relay and Substation Test System

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Advanced Test Equipment Rentals ATEC (2832)

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

L336i HARDWARE INSTRUCTION MANUAL

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Universal Protective Relay Test Set

DC POWER SUPPLY AX-3003L-3 AX-3005L-3. Users manual

EXPERIMENT 1 TITLE: SINGLE PHASE TRANSFORMERS - TRANSFORMER REGULATION

PTE-100-C. Current and Voltage Relay testing unit to 250A

PTE-50-CET. Three phase relay test set Current/Voltage

T 1000 PLUS Secondary Injection Relay Test Set

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

MULTI-OUTPUT DC REGULATED POWER SUPPLY

Power systems Protection course

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

RT-5005/5006/5007/5008

ELECTRICAL POWER ENGINEERING

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

HYVA404 CTPT Analyzer instruction manual (V1.3.19) CT/PT Analyzer. User Manual (V1.3.19)

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

LAB I. INTRODUCTION TO LAB EQUIPMENT

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

MINUTES OF PRE BID MEETING

Process Calibrator. TechChek 820

SPECIFICATION, CONTROLS AND ACCESSORIES

Three Phase Power Calibrator and Tester of Power Engineering Devices

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

FINAL - EST Electrical Service Technician Answer Schedule

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

DEPARTMENT OF ELECTRICAL ENGINEERING BENGAL ENGINEERING AND SCIENCE UNIVERSITY, SHIBPUR

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

JPQ2 PULSE ACCUMULATOR

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

ODEN AT Primary Current Injection Test System

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

OPERATOR S INSTRUCTION MANUAL

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

GFL-1000 User Manual Ground Fault Locator

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Variable Transformers Product Design & Engineering Data

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

AC/DC CLAMP METER USER S MANUAL

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Deploying Current Transformers in Applications Greater Than 200 A

HAWK5000 Operators Manual

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

PRODUCT TEST MANUAL 2SY110K28 SYNCHRONISM CHECK RELAY

MC133C/133Ci. Electric Power/Energy Calibrator. Operation manual

R PROFLAME Instruction Book Collection

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

RS Pro ENGLISH. Datasheet

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

UT232. Operating Manual. Digital Power Clamp Meter

MS2109A AC/DC Clamp Meter. User Manual. Contents

Box chopper amplifier BOE

Operating Instructions

Motoplat CV-014DS TESTER FOR DIAGNOSTICS OF ALTERNATOR STATOR WINDINGS AND DIODE BRIDGES USER MANUAL

SPAE 010, 011 High Impedance Protection Relay

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

SVERKER 750/780 Relay Test Sets

BC145 SIGNAL ISOLATOR BOARD

SIPROTEC 5 Application Note

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Application and Commissioning Manual for Numerical Over Current Protection Relays Type MIT 121/131 CONTENTS PAGE APPLICATION 2-4 INSTALLATION 5-11

MW3105 DIGITAL CLAMP MULTIMETER

FFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS. Version 1.0 MICRON OPTICS, INC.

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

ELECTRICAL POWER TRANSMISSION TRAINER

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

LAB I. INTRODUCTION TO LAB EQUIPMENT

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

Using the VR448 in place of the Marathon DVR 2000

DLVP A OPERATOR S MANUAL

Transcription:

PONOVO POWER CO., LTD No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 Office TEL. +86 (10) 5908 9666 E-Mail Info@relaytest.com Website www.relaytest.com T1000 Series Universal Tester VERSION: DATE: 16/01/2017 T1000-AE-2.10 This manual is the publisher of PONOVO POWER CO., LTD. To make any kind of copy of this manual please contact PONOVO POWER CO., LTD in advance. This manual represents the technical status for the moment of publishing. The product information, description and specifications mentioned in the manual do not have any contact binding force and PONOVO POWER CO., LTD remains the right to make modifications to the technical specifications and configurations without prior notice. PONOVO POWER does not take responsibility to the possible error/mistakes in this manual. 1

Notes In order to prevent accumulation of static electricity inside the running tester, make reliable ground connection via its ground terminal before the test. Be caution when output voltage is over 36V, this might cause some electric accident. Keep safety and avoid this situation occurring. When high current is being outputted, avoid personal injury and the equipment damage, which is under test. Never add external voltage and current onto the voltage/current output terminals of the tester. Since the tester is a kind of precision electronic equipment, keep a water-proof and damp-proof environment for it. Find any abnormal signs during the installation of the tester, please inform factory immediately and don t fix it by yourself. - 2 -

Notice: In order to facilitate the practical application, the design of the superstructure is removable; the illustration is shown in the chart below. - 3 -

Content 1. General Introduction... 5 2. Panel introduction... 6 3. Technique parameters... 8 4. Operation guide... 10 4.1 How to select test item... 10 4.2 How to select variable... 11 4.3 How to set parameters... 12 4.4 How to control output... 12 4.5 Report s setting, view and saving... 12 4.6 System setting... 13 5. Introduction to test function... 14 5.1.Aux DC... 14 5.2. Any test... 15 5.2.1 Manual &Meter... 15 5.2.2 Shot,Linear Ramp... 16 5.3 Relay test... 18 5.3.1 Trip time test, Trip time + pulse length test... 18 5.3.2 Trip value test... 19 5.3.3 Reclosing... 20 5.3.4 Motor overload test... 21 5.4 CT Test:... 22 5.4.1 Ratio test... 22 5.4.2 Excitation curve test... 23 5.4.3 Secondary impedance test... 25 5.5 DC test of operating loop... 26 5.6 Timer... 27 6. Accessories... 29 6.1 Soft Bag for Test Leads... 29 6.2 Transportation Case... - 34 - - 4 -

1. General Introduction The T1000 series single phase relay test kits are designed for easy and safe test of different type of relays. The powerful 1000A current source can be used to test all kinds of current relays, including high burden relay and CT. The AC/DC current and/or voltage sources allow phase angle and frequency to be adjusted smoothly. This makes it possible to precisely test directional and frequency relay. 1000A is integrated with two current sources and thus can test differential relays easily. The kit uses advanced switching power amplifier to replace the traditional transformer, thus avoiding the dangerous high voltage across the current output. Model High power AC current I1 Hardware Configuration T1000 1000A High power AC voltage U1 10-250V High power DC voltage Udc 10-300V Auxiliary DC 20-240V Ammeter 0-2000V Voltmeter 0-600V Binary inputs 2 Binary output 1 Function configuration Model Ratio CT test V-A test CT resistance Manual Auto Relay test Trip time Pick up Recloser Tripping current test Timer Multimeter T1000 5

2. Panel introduction 1) High power output: it s mainly applied for CT test and relay test. 2) AC/DC voltmeter and ammeter: they can be applied for measuring both internal and external outputs. 3) Binary output: one pair, relay contacts Binary input: two pairs with no polarity. It can not only receive protection acting contacts, but be applied for timer test, with single channel and double channels for options. 4) Auxiliary DC power supply: it s mainly used to provide power supply to protection or relay with the load of 0.5A. 5) Running lamp: it s used for the equipment to output indications. Overheat lamp: it will turn on the lamp, alarm and close the output, if the operation temperature of the power module inside the equipment exceeds 80. Overload lamp: it will turn on the lamp and close the output when an overload of current and/or voltage occurs. Open-circuit lamp: it will flame if an open circuit is detected at the output of high power current I1. 6

6) USB port: it is applied for reading report and debugging the computer in high level. 7) Menu selection, parameter setting and adjustment s output control areas. 7

3. Technique parameters High power AC current I1 Range 2-50A 50-10 Accuracy (relative) ±0.5% ±0.5% Compliance voltage 20V 7V Max load time 120S at 1000A High power AC voltage U1 Range 10-250V Accuracy (relative) ±0.5% Power 750VA(250V) High power DC voltage Udc Range 10-300V Accuracy (relative) ±0.5% Power 750W(300V) Auxiliary DC voltage Range 20-240V 0.5A Accuracy ±1% Power 55W/110V 110W/ 220V Output time Continuous at 0.5A Ammeter and voltmeter 8

Voltmeter Ammeter 0~600V 0~6A AC direct measurement Range AC/DC 0-2000A AC with external CT Accuracy ±1% ±1% 9

4. Operation guide 4.1 How to select test item The tester has a test unit selection area on the right bottom of the equipment panel, where gets 4 buttons: F1, F2, F3 and the menu. Press the MENU button in the area, you will enter into the main menu directly. In the main menu, rotate the ENTER button to select certain test item, and then press the ENTER button to go into the interface of the test item you selected. For sub-menu, you may press the F1 button to go back to last level menu. 10

4.2 How to select variable In the test item interface, rotate the ENTER button (clockwise or counter clockwise) to select the variable. The variable you selected will be displayed in white characters with black background. 11

4.3 How to set parameters When the variable was selected, press the ENTER button and rotate it clockwise or counter-clockwise to change the magnitude of the variable. Select the step of parameter changing by using the Fast/Fine adjustment button. You may switch the step between 0.001, 0.1, 1,10,100 and 1000 by pressing the button. The parameter setting of action unit and manual unit: Both before and after test, you may select certain variable to set corresponding parameters Both before and after test, you may press the Fast/Fine adjustment button to change the variable output. Other units can t be changed with their parameters as soon as the test starts. 4.4 How to control output The Run and Stop buttons are applied to control the tester of its output, or to stop it. 4.5 Report s setting, view and saving 4.5.1 Report view: select the view option in the main menu to go into the report view interface, where you may view all saved reports. Here, each page can display 10 reports. With total 3 pages, it can save 30 reports at most. 1/3 denotes there have 3 pages and the current page is the first page. The report with cursor below has test items whose names are listed as following figure in their item names. 12

4.5.2 Report saving: after the test, you may save current item following the guide on the screen. Both date and time will be saved in the report. 4.6 System setting Select the system setting option in the main menu, and then go to its interface, where you can set time, volt, freq., off delay. Time can be represented by second or cycles. Off delay:when the tester receive a trip or reclose signal from the relay undertest, the tester will generate the voltage and current continually,until the delay time end. 13

5. Introduction to test function 5.1.Aux DC Mainly provide power supply for protection or relay Select the Aux DC menu as above figure shown. Set the output voltage value,press the Run button to output The ON/OFF button on the panel can control the output voltage, Note: a. The aux DC output can be controlled by the ON/OFF button, and be outputted 14

with other terminals at the same time. b. The maximum output current is 0.5A. 5.2. Any test 5.2.1 Manual &Meter This unit can output high power AC voltage/current, high power DC voltage, high precision voltage/current and display the reading values of voltmeter and ammeter. It can realize manual control on the amplitude, phase of AC variables or amplitude of DC variables by the step. 15

5.2.2 Shot, Linear Ramp It can output high power AC voltage/current, high power DC voltage, high precision voltage/current, realize automatic control on amplitude, phase of AC variables and amplitude of DC variables by the step, and record action values, action time automatically. There have 3 test methods for your selection. Pulse Select variables from the menu: AC-I1-1000A, AC-I1-50A, AC-U1, U DC Set the start value and duration time of variables. Press the Run button to output. When the tester receives the binary input of protection acting signal and finish recording the action time, the test will stop. 16

Linear ramp Select output phase from the menu: AC-I1-1000A, AC-I1-50A,, AC-U1, UDC Set variable, start value, stop value, step and step time. Press the Run button to start output, shown as figure. The variable will gradually increase on the step from the start value to the stop value. When the tester receives the binary input of protection acting signal and finish recording the action time, the test will stop. 17

5.3 Relay test 5.3.1 Trip time test, Trip time + pulse length test There have two states for setting. You can set amplitude and phase for these two states, and the tester will count time when entering into the 2nd state. Perform tests on the action time in all kinds of over-voltage/current and under-voltage/current relays. Test process 1) Select test item. 2) Set voltage and current values. Set the variable of Offset to relay but no-action. Set the variable of test to reliable action of relay undertest. 18

3) Test: Press the Run button, the tester will start to output under the Offset. Press the ENTER button into the Test and start time counting at the same time. As soon as the tester receives the binary input of protection acting signal, the tester will start to record the action time,pulse time. 5.3.2 Trip value test a) For high power output, you can manually control the amplitude to change on the step. b) Nominal voltage and current can manually control the amplitude, phase and frequency of AC variables and amplitude of DC variables to change on the step. Test process: 19

1) Select test item and then go into the action value test unit. 2) Set voltage and current values. 3) Press the Run button the tester starts to output based on the setting rotate the ENTER button to control the output of the variable you selected as soon as the tester receives the binary input of relay acting signal, the tester will start to record the action time. change the variable to make the relay equipment return the record values, and automatically calculate the return coefficient at the same time, and finally stop the test. 5.3.3 Reclosing a) This unit can perform reclosing test, set 6 times of faults at most and record 6 times of reclosing time. b) During test, you must connect the relay s acting contacts and reclosing contacts to the binary input terminals of the tester to make sure the correct logic for output. 20

c) Time counting definition: pick up, denotes the time of first time tripping; reclosing, denotes the time between binary input a and b after each fault. Test process: 1) Select test item, go into the reclosing unit. 2) Set the fault times, which can be 6 times at most, and each fault current (I1/I2 for options) 3) Press the Run button, the tester will start to output based on the setting. As soon as the tester receieves the binary input of relay acting signal, it will record acting time, reclosing time, etc. 5.3.4 Motor overload test This unit can test trip time of motor. 21

The output current values can be set in two states, the tester will count time when press the ENTER button. There are two ways to record the action time. Firstly, as soon as the tester receives a single from the relay under test; secondly, the current stop to output, In this unit, the max output time of max output current is 40s. Test process 1) Select test item. 2) Set current values. 3) The first state output current value should be smaller than trip current value of relay. 4) The second state output current value should be bigger than trip value of relay, and makes the relay act. Press the Run button, the tester will start to output the first state current value. Press the ENTER button, the state will change into the second state and start time counting at the same time. As soon as the tester receives the acting signal from relay or stops to output, the tester will record the action time. 5.4 CT Test: 5.4.1 Ratio test 22

Connect I1 output to the CT once side and CT secondary side to the current measuring terminal, shown as above figure. Don t make open circuit. Select the Ratio 250A menu, shown as above figure. Set the current for output, and CT secondary current rating. The software will calculate the ratio by the CT secondary current rating automatically. Press the Run button to output current. The tester will display the current it has measured and the ratio that has been calculated. 5.4.2 Excitation curve test 23

Connect wires as above figure shown Select the Excitation Curve test menu, shown as above figure. Set the start current value for output Press the Run button to output the start current, elevate the current gradually and record the corresponding voltages that have been measured and corresponding series of test points. Note: During the test, the current should be rise gradually and can t be swing up and down, which might cause remanence. The existence of remanence will have great effects on the measuring results. Once this situation happens, you should re-elevate the current to be higher than the original value and then decrease it gradually to zero. Repeat foregoing process for one or two times, thus the effect of CT remanence can be cured. 24

5.4.3 Secondary impedance test Connect wires as above figure shown. Disconnect the connecting sheet inside the CT terminal box heading to CT winding. Select the Manual&Meter menu, shown as above figure. Set the current value for output, which is normally the secondary current rating. Press the Run button to output current, and the tester will display the voltage and secondary impedance value that have been measured. 25

5.5 DC test of operating loop Connect wires as above figure shown. Select the Manual&Meter menu, shown as above figure. Select the DC voltage value from the menu. Press the Run button to output the DC voltage, adjust DC voltage value, and record the corresponding DC current value at the same time. 26

5.6 Timer Single channel test Double channels test Connect wires as above figure shown Select the Timer menu, shown as above figure. 27

Set single channel and/or double channels from the menu. Press the Run button to start the test. The action time will be measured automatically before the test has ended. 28

6. Accessories 6.1 Soft Bag for Test Leads The T1000 Wiring Accessory Package contains the following articles: 1. Colour coded current cables Colour coded current cable Amount: 1xred, 1xblack The current cables to connect the T1000 output to other safety sockets of, generally the current parts. 29

2. Color coded voltage cables and signal cables Colour coded voltage and signal cable (Long) Amount: 2x red, 2x black Colour coded voltage and signal cable (Short) Amount: 2x red, 2x black The voltage cables to connect the T1000 output to other safety sockets of, generally the voltage parts and signal tripping. 30

3. Crocodile Clips Crocodile clips 10mm Crocodile clips 20mm Amount: 2xred, 2xblack, 2xred, 2xblack, Crocodile clips for secondary side to connect to pins or screw types. 4. Pin clamps Pin clamps Amount: 2xred, 2xblack It is used to connect test leads with screw type terminals. 31

5. Power Cord Power cord Amount: 1 piece Power cord connects the T1000 with power supply socket. 32

6. Grounding cable Grounding cable Specification: 2.5mm² 4m Amount: 1 piece Grounding cable connects the T1000 with ground to ensure kit safety. ------------------------------------------------------------------------------- Notes: In order to avoid static induction, users should connect the T1000 with ground reliably before testing. ------------------------------------------------------------------------------- 33

T200A Operation Manual 6.2 Transportation Case The large-size case with wheels is designed for heavy transport stress with folding hand it is made of fireproof materials and smooth rolling rubber tires. Transportation case - 34 -