RUDOLF Digital power analyzer. Advanced Version

Similar documents
DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

Enhanced Quality with a Touch of Style

Applications. diris_581_e_1_gb_cat

COUNTIS and DIRIS systems CONTROL AND ENERGY MANAGEMENT FOR ELECTRICAL NETWORK INSTALLATIONS

 Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat

Energy Measurement & Management

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM9

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

DIRIS. The multi-function multi-measurement range MADE TO MEASURE

DE MEDIDA PROGRAMABLES - CLASE 0,2 MEASURING PARAMETER. Apparent power, per phase and total

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

PEM353. Universal measuring device

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Centrale de mesure Power Meter PM500 Merlin Gerin

MT 560/UMT TRANSDUCER & ANALYZER

Multimeter 500CVD21 RTU500 series

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

Energy Management Three-phase energy meter with output modules Type EM4-DIN

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Energy counting and measurement

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

DPF-MAC Auto power factor controller

EM-72 Electricity Meters for Current Transformers

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

ZHUHAI PILOT TECHNOLOGY CO., LTD.

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Monitoring Electric Network Via Internet

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Integra 1560 and 1580 Digital Transducer Systems

Protective Relays Digitrip 3000

Contents. Introduction and description Package contents Device identification PM Options... 80

sustainable savings that can be viewed directly on the internet

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Data Sheet. RISH Master Record %THD

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Application and features

ENGLISH WM3-96. ISE, Inc Royalton Rd. - Cleveland, OH USA - Tel: (440) Fax: (440)

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

1 INTRODUCTION ORDER CODE / INFORMATION

Digital Multifunction Instrument - Rish Master 3440

DUCATI INSTRUMENTS COMPARISON TABLE

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

Power factor correction and harmonic filtering. Automatic power factor regulators

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

ULTRA RAPID POWER QUALITY ANALYZER

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

ENERIUM. A powerful solution for energy management and the environment

Universal measuring transducer

Energy Management Modular Smart Power Transducer Type SPT-90

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

N. TEST TEST DESCRIPTION

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

PD300. Transformer, generator and motor protection Data sheet

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Power factor correction and harmonic filtering. Automatic power factor regulators R.1

Technical Data Sheet. x1000. kwh R Y B

Gutor PxW AC UPS Designed for North American Market

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management Modular Power Analyzers Type WM2-96

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

AMIK 200 / 201 Technical Data Sheet

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

269 Troubleshooting Guide 11/4/98 1

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Technical Data Sheet AMIK 300 / 301

The wireless alternative to expensive cabling...

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

The wireless alternative to expensive cabling...

Measuring transducers

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

EN61036 EN61268 CARLO GAVAZZI

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

IS-3000 SERIES INFRARED SCANNER

Transcription:

RUDOLF Digital power analyzer Advanced Version

Digital power analyzer Advanced Version Company Introduction Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for the Asian market. We are the first local electrical switchgear components manufacturer that launches our own Asian identity Today we aim to become a knowledge-based, technology driven engineering organization, with emphasis on providing solution for electrical distribution and control. Specialize in instruments & power quality equipment, we offer our expertise as a solution provider in this area. With our present headquarter in Singapore and subsidiaries that are located in Australia, Malaysia, Philippines and Vietnam, we are well equipped to service both local market and countries in the Asia Pacific. Product Introduction Control your energy distribution with Rudolf digital power analyzer made to measure. There is an increasing trend in electrical installations, operators need to identify large consumers, analyze networks and diagnose fault. Rudolf provides a universal multi-function solution with the advanced version R-DPA96A. The R-DPA96A optimizes the operation of your electrical network by Reducing operating costs Cutting down production losses Optimizing maintenance costs Improving the performance of the installation Basic Features Measure all electrical values to check that your network is functioning properly. Monitor your electrical networks using alarms for feeder load levels or loss of phase, voltage surges, voltage dips and outage. Analyze energy quality by breaking down the harmonics by phases to prevent cable over-heating, transformer overload or equipment ageing. Meter the energy used by buildings or production processes so that you can spread and optimize energy costs. Control to open or close feeder control gear (lighting, motor, production line, heating, air-conditioning). Centralize all data using digital (RS485 JBUS/MODBUS or PROFITBUS DB) or analogue communication. Added Advantages Optimized visibility The display showing the electrical values of the installation has have optimize using a large easy-to-read configurable backlit LCD. Direct access The large keys give quick and direct access to the data you want, without having to navigate through the menu. Plug & display modules Optional modules which can be used to add additional functions at any time. Easy to install Designed for ease in installation, R-DPA96A come with Compact 96 x 96 x 60 mm dimension (80mm with optional module) Easy to use terminal blocks for fast cabling Simple fixing using retaining clips A self test diagnostic menu to identify incorrect connection

Basic Features Rudolf Digital Power Analyzer - Advanced Version

Rudolf Digital Power Analyzer - Advanced Version Specifications Type of measurement Network (3P3W, 3P4W & single phase) LV/HV True RMS value upto harmonics 51 Accuracy of measurement Current 0.2% from 10 to 110%/ In Voltage 0.2% from 140 to 700% VAC Power 0.5% of full scale (-90 to +90 ) Power Factor 0.5% for 0.5 < PF< 1 Frequency 0.1% from 45 to 65 Hz Active energy ±0.5% from 0.02 to 1.2 In with PF = 0.5L or 0.8C (Class 0.5s IEC 62053-22) Reactive energy ±2% from 0.1 to 1.2 In with cos = 0.5L or C (Class 2 IEC 62053-23) Display refresh rate Time 1sec Current inputs Primary CT 5-10000A Secondary CT 5A / 1A Sensing range 10mA to 10A Permissible overload 50A 1sec Consumption < 0.1VA Galvanic insulation 2.5kV CT earth connection (secondary) yes Voltage inputs Direct measurement Voltage sensing transformer (secondary 60, 100, 110, 115, 120, 173, 190V) Galvanic insulation Frequency from 18 to 700VAC (phase/ phase) from 10 to 404VAC (phase/ neutral) 2.5kV 45 to 65 Hz Update period 1 second Auxiliary power supply Standard 110 to 440 VAC ±10% 120 to 350 VDC ±20% Others 12- to 48VDC -6/+20% Consumption < 10VA Inputs Type Monitoring or command outputs Type Pulse outputs Type Communication RS 485 Protocol Speed Analogue outputs 0/4 20mA Load resistance Response time Memory Memory size Optocouplers (10 to 30VDC) REED relays (250VAC 5A 1250VA) REED relays (100VDC 0.5A 10VA) 2 or 3 wire half duplex PROFIBUS/ JBUS/ MODBUS protocol mode 2400 to 38400 Bauds 0 to 600 ohms 1sec 512 ko

Rudolf Digital Power Analyzer - Advanced Version Ordering Information Product code R-DPA96A R-DPA96AN R-MODULE 1 R-MODULE 2 R-MODULE 3 R-MODULE 4 R-MODULE 5 R-MODULE3+6 R-MODULE 7 Description Basic unit supply 110 to 440VAC & 120 to 350VDC Basic unit with measured neutral supply 110 to 440VAC & 120 to 350VDC Pulse Output 2 configurable pulse outputs Pulse Output & Harmonics 2 configurable pulse outputs + harmonics Communication JBUS/MODBUS Communication module RS485 for JBUS/MODBUS Analogue Outputs 2 configurable analogue outputs 2 inputs - 2 outputs 2 inputs / 2 outputs Communication PROFITBUS DB Communication module RS485 for PROFITBUS DB Memory Memory module R-DPA96A can be communicated remotely using Control Vision software to: - Centralize and display all electrical values - Create demand curves - Historical trend analysis of measured values - Manage alarm logs Display showing numerical values or Indicator for all electrical values All electrical values permanently scanned are stored in a database in a table which can be displayed for a selected time period Display tables of energy consumption (electricity, gas, water) or pulses counted Every R-DPA96A present on the network can be viewed in the form of al table showing all electrical values 3 rd order to 25 th order harmonics display in table form or as bar chart

Rudolf Digital Power Analyzer - Advanced Version 47 Yishun Industrial Park A, Singapore 768724 Tel : 6756 0833 Fax : 6756 2007 Website : http://www.bridex.com.sg E-mail : sales@bridex.com.sg R-0EDCI-000MR-C0-0806