Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Similar documents
CP CU1. Coupling unit for line and ground testing

CT Analyzer. Revolution in current transformer testing and calibration

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

Onsite Mobile AC High Voltage Test System

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

TRAX Transformer and Substation Test System

MONTRANO. Continuous monitoring system for power transformers

Diagnostic testing of cast resin transformers

N. TEST TEST DESCRIPTION

Specialists in HV and MV test and diagnostics. Testing in Substations

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

TESTRANO 600 ordering information

CT Analyzer. Current transformer testing, calibration and assessment

Primary Test Manager (PTM) Testing and management software for primary assets

World Leader in Innovative Power System Testing Solutions

N. TEST TEST DESCRIPTION

MPD 500. Partial Discharge Measuring System for Routine Test Applications

Substation Preventive Maintenance

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

TESTRANO 600. Three-phase test system for comprehensive power transformer testing

Why partial discharge testing makes good sense

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

3. COMBINED TRANSFORMERS Oil-paper insulation

OFFER OF SERVICE / Cité 1200 Logts, Coopérative Granitex Bt. 05, N 01-Bab Ezzouar Alger Algerie

MEDIUM & HIGH VOLTAGE

UTILITY & SUBSTATION TESTING

TESTRANO 600. Three-phase test system for comprehensive power and distribution transformer testing

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Three-Phase Transformer Test Systems

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

ODEN AT Primary Current Injection Test System

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

VOTANO 100. Accurate and mobile voltage transformer testing and calibration system

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

Automatic Transformer Winding Analyser

HV AC TESTING OF SUPER-LONG CABLES

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

700 Series AC Dielectric Test Sets

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

The importance of partial discharge testing throughout the development and operation of power transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

Fully automated three phase 250V Transformer Turns Ratio Meter

MIT510/2, MIT520/2 and MIT1020/2

ELECTRICAL POWER ENGINEERING

True Three-Phase Transformer Turns Ratio Tester TRT4x

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

SGM series. AC Resonant Test System. Applications & Advantages

Three-Phase Winding Ohmmeter TWA25K

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

TRM-203/403 transformer resistance meters

FRAX Series Sweep Frequency Response Analyzers

VFRA-25 transformer frequency response analyzer

True Three-Phase Transformer Turns Ratio Tester TRT4x

Advanced Test Equipment Rentals ATEC (2832)

CIBANO in-1 test system for medium- and high-voltage circuit breakers

Tan Delta test on rotative machines (generators and motors) Fully automatic

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

700 Series AC Dielectric Test Sets

Capacitive voltage transformers

True Three-Phase Transformer Turns Ratio Tester TRT40A

RESONANT TRANSFORMER

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

OMICRON Academy Hong Kong. Excellence through Education

Dissipation / Power Factor and Capacitance Measurement on Rotating Machines using the CPC100/TD1 and CR500

Transformer test equipment easy to use

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

The NEW itig II Winding and Motor Analyzer A revolution in automated, safe, and comprehensive high and low voltage tests all in a lightweight

Maintenance & Diagnosis Strategies. for. High Voltage Substations

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

S T S MULTIFUNCTION SUBSTATION MAINTENANCE & COMMISSIONING TEST SYSTEM FOR CURRENT, VOLTAGE AND POWER TRANSFORMERS THE OPTIONAL MODULE TD 5000

PHG 70 TD PD / PHG 80 TD PD

Končar TMS - Bushing monitoring

CONTENTS. 1. Introduction Generating Stations 9 40

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Advanced Test Equipment Rentals ATEC (2832)

Fixed Series Compensation

AC Dielectric Test Sets

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

EI HIGH VOLTAGE INSULATION TESTING POLICY

ELECTRICAL POWER TRANSMISSION TRAINER

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing

A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear to date Gas-insulated switchgears (GIS) are compact and are, therefore, used in applications where space is limited. For commissioning of GIS a high-voltage (HV) withstand test is required in accordance with standards (IEC 62271-203). To date the test voltage needed for a withstand test has been produced by a resonance circuit. This test system consists of an HV test transformer and a coupling capacitor. This resonance circuit, a resonant coil, and a power control unit have to be connected to the GIS. Weak points of this testing principle: > The complete test system is difficult to transport, because it consists of very heavy and large components. > It is difficult to use it at test sites with limited space, such as wind turbines. > The HV test lead must be connected to, and disconnected from, the GIS system for testing. This normally includes a time-consuming venting and refilling process of the SF 6 gas. Auto-transformer CP AT1 The CP AT1 allows you to connect the mains supply of the CPC 100 to a three-phase 16 A power outlet, and delivers the required power for the test setup. Control unit CPC 100 The CPC 100 supplies the required energy and acts as both measuring and controlling device. Isolation transformer CP TR The CP TR provides a potential-free output signal and compensates the capacitive load. CPC 100 + CP RC1: testing GIS up to 123 kv rated CPC 100 + CP RC2: testing GIS up to 145 kv rated voltage 2

Innovative GIS testing With OMICRON s CPC 100 + CP RC you can perform GIS tests without the need of a big HV transformer. This is possible because the system directly makes use of a specially designed Power VT for testing. This Power VT is an integral part of the GIS and generates the required test voltage. CPC 100 injects power at the low-voltage (LV) side of the VT, producing the necessary voltage on the HV side. As you can directly connect the measuring system to the integrated VT of the GIS system it eliminates the need for draining and refilling any SF 6 gas. The CPC 100 + CP RC system comprises several small and light-weight components (< 21 kg / 46 lbs) which can be transported by one person. With its modular design you can perform GIS tests even at test sites with limited space. Powerful voltage withstand testing With the combination of CPC 100 + CP RC1 you can perform voltage withstand tests with a maximum test voltage of 200 kv on GIS systems up to a rated voltage of 123 kv. For testing GIS systems with a rated voltage of up to 145 kv and a maximum test voltage of 235 kv, CPC 100 + CP RC2 is appropriate. This package is supplied with the additional CP AT1 auto-transformer to guarantee the necessary output power of the CPC 100 for higher loads. High-voltage source for partial discharge measurements During production or maintenance, impurities can occur in GIS. These can cause major problems in operation. Therefore, it is recommended to perform a partial discharge measurement during commissioning (acceptance tests). While performing these measurements with OMICRON s MPD series you can use CP RC as the highvoltage source. Compensating reactor CP CR With 4 mh (CP CR4) or 6 mh (CP CR6) the CP CR compensates the capacitance in a modular fashion. Power VT In addition to the measurement function of a VT the Power VT offers the possibility to generate high voltage for testing. Your benefits > Light-weight: less than 21 kg / 46 lbs per unit GIS > Small: less space required on site > Powerful: up to 235 kv test voltage > Fast: short measuring time as no draining or refilling of SF 6 gas is necessary voltage 3 GIS

CPC 100: flexible and powerful unit Full control of your tests During GIS tests OMICRON s CPC 100 is used as the control unit for the CP RC resonance circuit. Using the front panel of the CPC 100 you can conveniently control the CP RC and define your own test templates. After transferring the test results to a PC, you can create customized reports including graphical result evaluation and further analyses. High-voltage measurements on GIS If available, you can use a second VT of the GIS system to measure high voltage. As soon as you enter the VT ratio CPC 100 will directly display the actual test voltage. If there is no second VT accessible for the HV measurement, CPC 100 can determine the test voltage. It uses the LV input to the Power VT and automatically compensates the losses of the winding to achieve high accuracy. Automatic detection of resonance frequency The system s resonance frequency is automatically detected by CPC 100. This frequency is needed to determine the absolute capacitive load and for adjusting the frequency to the resonance point of the compensated system. Programmed to individual requirements The user-friendly software allows you to program a voltage ramp in accordance with the specific standard or your personal requirements. After performing the test you can directly assess the values and save the test protocol. 4

CPC 100: the all-in-one system Apart from GIS, the CPC 100 covers a lot of other applications in and around substations as well as at the manufacturer s production site. The powerful device provides up to 800 A or 2 kv with up to 5 kva over a frequency range of 15 Hz to 400 Hz or 400 A DC. It can test various substation assets, thereby replacing several individual testing devices. This makes testing with CPC 100 a time- saving and cost-effective alternative, especially as the application range of CPC 100 is further expanded by a high number of valuable accessories. Despite its expansive capabilities, the CPC 100 is very simple to use. Thus it is the ideal instrument for all major applications in the area of substation asset testing. Featured assets > Current transformers > Voltage transformers > Power transformers > Power lines > High-voltage cables > Grounding systems > Rotating machines > Switchgear and circuit breakers > IEC 61850 installations > Protection relays Ground resistance meter Micro ohmmeter 400 A DC Turns ratio meter for transformers, CTs and VTs High-current injection transformer 29 kg / 64 lbs single phase wall outlet Tester for Rogowski coils and other unconventional CTs / VTs (IEC 61850) Winding resistance meter Power meter (P, Q, S) Protection relay tester (one phase V, A, f) Excitation curve tester 2 kv 400 A DC Multimeter (V, I, R, Z,...) 12 kv (with booster) 800 A AC Phase angle meter 2 ka (with booster) Step up transformer 2000 V Line impedance and cable measurement Complex impedance meter (burdens, cables, lines and transformers) 15 Hz - 400 Hz On load tap changer test equipment Vector group verification system for power transformers Polarity checker Power / dissipation factor measurement set 5

Technical specifications and ordering information CPC 100 CP TR Power specifications Power specifications Single-phase, nominal 1 100 V... 240 V AC, 16 A Frequency range 90 Hz... 120 Hz Single-phase, permissible 85 V... 264 V AC (L-N or L-L) Inductivity 7 mh (CP TR7) / 8 mh (CP TR8) Frequency, nominal Mechanical data Dimensions (W H D) (cover without handles) 50 Hz / 60 Hz 468 394 233 mm / 18.4 15.5 9.2 in Apparent power on secondary side Outputs Output voltage 10.8 kva r (CP TR7) / 13.2 kva r (CP TR8) 180 V (CP TR7) / 220 V (CP TR8) Weight (case without protection cover) 29 kg / 64 lbs Output current Mechanical data 60 A Dimensions (W H D) (cover without handles) 262 225.5 222 mm / 10.3 8.9 8.7 in Weight 19 kg / 42 lbs CP AT1 CP CR Power specifications Three-phase, nominal Frequency, nominal Outputs Output voltage Output current Mechanical data Dimensions (W H D) 262 277.5 222 mm / 10.3 8.7 10.9 in Weight 3 400 V AC, 16 A 50 Hz / 60 Hz 254 V AC... 278 V AC (4 steps) 16 A 15.5 kg / 34 lbs Power specifications Frequency range Inductivity Apparent power on secondary side Outputs Output voltage Output current Mechanical data Dimensions (W H D) (cover without handles) Weight 90 Hz... 120 Hz 4 mh (CP CR4) / 6 mh (CP CR6) 33 kva r 220 V 150 A 262 225.5 222 mm / 10.3 8.9 8.7 in 20.5 kg / 45 lbs Package specifications CP RC1 CP RC2 GIS voltage, nominal 123 kv AC 145 kv AC Maximum test voltage 2 200 kv 235 kv Maximum system power > 40 kva r for > 1 min > 50 kva r for > 5 min Maximum capacitive compensation range 1 300 μf at 100 Hz 1 600 μf at 100 Hz Weight 68 kg / 150 lbs 103 kg / 227 lbs Temperature Operating: -10 C... +55 C / +14 F... +131 F Storage: -20 C... +70 C / -4 F... +158 F Operating: -10 C... +55 C / +14 F... +131 F Storage: -20 C... +70 C / -4 F... +158 F Humidity range 5 %... 95 % relative humidity, non-condensing 5 %... 95 % relative humidity, non-condensing 1 There are power restrictions for mains voltages below 190 V AC. 2 There can be voltage restrictions depending on the integrated Power VT. 6

CP RC1 resonance circuit (order no. VEHZ0760) Hardware 1 1 CP CR4 1 CP CR6 1 CP TR8 Software 1 HV resonance test system test card Cables and accessories 2 CP RC Y cable 4 m / 13.1 ft black (16 mm 2 ) 2 CP RC Y cable 4 m / 13.1 ft red (16 mm 2 ) 1 CP RC cable 1 m / 3.3 ft (16 mm 2 ) 1 Booster connection cable 6 m / 19.7 ft (3 1.5 mm 2 ) 3 Grounding cable (green/yellow) 6 m / 19.7 ft (6 mm 2 ) 1 Current transformer KSO104 1 Terminal adapters 2 Transport case 1 CP RC1 user manual CP RC2 resonance circuit (order no. VEHZ0770) Hardware 1 1 CP AT1 1 CP TR7 3 CP CR6 Software 1 HV resonance test system test card Cables and accessories 2 CP RC Y cable 4 m / 13.1 ft black (16 mm 2 ) 2 CP RC Y cable 4 m / 13.1 ft red (16 mm 2 ) 1 CP RC cable 1 m / 3.3 ft (16 mm 2 ) 1 Booster connection cable 6 m / 19.7 ft (3 1.5 mm 2 ) 5 Grounding cable (green/yellow) 6 m / 19.7 ft (6 mm 2 ) 1 Power cord 3-pole 1 Power cord 5-pole 1 Current transformer KSO104 1 Terminal adapters 3 Transport case 1 CP RC2 user manual 1 The CPC 100 control unit has to be ordered separately. For further information on the CPC 100, please have a look at the CPC 100 brochure. 7

OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete. Customers in more than 140 countries rely on the company s ability to supply leadingedge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry. The following publications provide further information on the solutions described in this brochure: CPC 100 Multi-functional primary test system for substation commissioning and maintenance MPD 600 High-end measurement and analysis system for partial discharges CPC 100 brochure MPD 600 brochure For more information, additional literature, and detailed contact information of our worldwide offices please visit our website. www.omicron.at www.omicronusa.com OMICRON L2234, September 2013 Subject to change without notice.