Permissible Variations

Similar documents
WaveTrax. Fiber Cable Management System

99 Straight Sections 100 fittings, splices & connectors. 103 fasteners

ES-A Series Photovoltaic Panels

P2784 3" (76.2) (31.8) 25 to 45 PFL2-37

Numerical Roots and Radicals

Estimates based on a model of room acoustics. Arthur Boothroyd 2003 Used and distributed with permission for 2003 ACCESS conference

TRUflex PWR Series. High Power RF Cable Assemblies

388 SQUARE BASE TIME DELAY RELAYS

NOTES: 4" OVERHANG MAX. (TYP) DETAIL N (SHEET 13)

Turn your soroban into a foot inch calculator By Dino Marcantonio

4-7 Point-Slope Form. Warm Up Lesson Presentation Lesson Quiz

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

The several methods for making linear measurements are quite simple and straightforward. They are described below:

Tru products are now under the Tru-Win brand from Winchester Interconnect.

CHAPTER WAVE MOTION

Forming and Shoring Product Selector

CertainTeed Ceilings

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

How Close Can You Get?

Construction Tolerances - The following tolerances apply to cast-in-place structures:

Fleet of our own Semi Trucks to reach all states. 80,000 sq. ft. 125,000 sq. ft. 12 Crane Building 25,000 sq. ft. Office Space.

Model Number Designation F- PV2R1-6 -L -R A A -42 -* Shaft Rotation. A: Upwards (Normal)

SECTION 5 TOLERANCES

Split case double suction centrifugal pump. Technical data Serie: DPAS C

Chapter 5. Veneer and Plywood

IPE 381 Chapter:04 Limit, Fits and Tolerance

POST TEST KEY. Math in a Cultural Context*

Learning Log Title: CHAPTER 2: ARITHMETIC STRATEGIES AND AREA. Date: Lesson: Chapter 2: Arithmetic Strategies and Area

Linear Equations in Two Variables

Tru products are now under the Tru-Win brand from Winchester Interconnect.

Extract 8.7 When dimensioning an acute angle the tangential lines shown in Figure 4 shall be used. (C) Figure 4 - Dimensioning of an acute angle

Section 8 Stainless Steel Buttweld Fittings & Flanges

Math Review Questions

Similar Polygons

Squares Multiplication Facts: Square Numbers

Sand Surf and Sun. APQS Lethbridge a Ave North Lethbridge Alberta Canada

Oblique Surfaces. Obl-1. Surface A is cut at an angle to all three reference planes. It will appear foreshortened in all the regular views.

ERRATA APRIL Manual of Standard Practice 29th Edition, 1st Printing, 2018

Rugged Powerful Durable

FSA Math Review. **Rounding / Estimating** **Addition and Subtraction** Rounding a number: Key vocabulary: round, estimate, about

DIBD2 and DIBD23 CURTAIN TYPE DYNAMIC FIRE DAMPERS 1 1 /2 AND 3 HOUR UL555 RATED FOR USE IN DYNAMIC AND STATIC SYSTEMS

COLUMN 11/2013 LINEAR STRUCTURAL ELEMENT

Safety Awareness Barriers

E4-WM5-Y525A00 MOUNTING INSTRUCTION

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

Suggested Reinforcement Detailing Practices Based on comments from R&D and ES ESS Committees

SL1117C 1A Low Dropout Positive Voltage Regulator

DIJET INCORPORATED

CONTINUING EDUC ATION

Lead Screw Assemblies

Actual testimonials from people that have used the survival guide:

DUCTILE IRON PIPE JOINTS AND THEIR USES

Incremental encoders Solid shaft with square flange pulses per revolution

Installation Manual. For Gerard Shingle Products

CM6200 MILLING MACHINE

22 22, 24, , 18, AWG. 50 ohm 50 ohm. 75 ohm 75 ohm. 95 ohm 95 ohm

Insulator (Heat & Frost) IP Red Seal Practice Exam BLUE PRINT READING

Grade 2 Mathematics Scope and Sequence

DF COLLECTION. Architectural Detail Guide Double-Hung Window DF 3604 TABLE OF CONTENTS

COMPOSITE RAILING INSTALLATION

Architectural detail manual Double-Hung window DF3604

Rigid Line Components and Accessories

HP-4 Wall Wash Recessed Flush Diffuser Visible Flange Starter/Independent Installation Instructions

Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1

Effective Date: September 2017 Void After: September Product: Cast Iron Soil Pipe and Fittings (Hubless) File No. 4818

Multiplication and Area

Dimensioning. Dimensions: Are required on detail drawings. Provide the shape, size and location description: ASME Dimensioning Standards

( This link will provide you with a list of all ISO-6983 G-Codes

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

Trigonometry, Exam 2 Review, Spring (b) y 4 cos x

Legal Description & Site Plan Requirements and Layouts

appendix f: slope density

01. a number of 4 different digits is formed by using the digits 1, 2, 3, 4, 5, 6,7, 8 in all possible

Create Fractions in Google Sketch up

KwikSplice aluminum cable tray system

WORKSHOP DRAWING & DESIGN STANDARDS

Aircraft Drawing and Blueprint Reading

Machine Drawing MEC-304. Dr. Shankar Sehgal Asst. Professor in Mech. Engg. UIET, Panjab University, Chandigarh

CGT KROSSGRINDING. Plated diamond tools 3.1. Approximate Surface Finish

SWITCH STAND Switch Stand Assembly Connecting Rod Target Assembly (when required) TURNOUT ACCESSORIES Standard Tie Plates Rail Anchors Joints

Injection Molding. System Recommendations

SUPPLEMENT 1127 PAY FACTORS DETERMINATION FOR PAVEMENT AND STRUCTURE CONCRETE

Known Errata/Corrigenda Items: ISO/FDIS 10423:2003 (E) (*Items starred are of higher priority for correction)

Performance Data. Single Deflection Register, DDFRSDS 5 Double Deflection Register, DDFRDDS 5

SECTION 3. Housing. FAppendix F SLOPE DENSITY

SECTION CABLE TRAYS

Covering and Surrounding Practice Answers

Bulk Storage Rack Assembly Instructions

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

= 5th_Grade_Math (5th_Grade_Math) What is the perimeter of the triangle shown in the drawing? A. 1,258. B C D. 1.

WOOD FRAMING WALL+ FEATURES

Section 1.4 Fractions LAWS & PROCESSES. Addition of Fractions DEFINITIONS & BASICS. 1. Common Denominator 2. Add numerators 3. Carry by denominator

Section 1: Data (Major Concept Review)

Slope. Domain 2 Lesson 11. Getting the Idea

LINER MEASURING Made Easy

Wednesday, May 4, Proportions

Math 65A Elementary Algebra A Exam II STUDY GUIDE and REVIEW Chapter 2, Sections 3 5, and Chapter 3, Sections 1-3

LIVE CENTER BIN. c. DONALD FISHER

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

Transcription:

H-Pile & Wide Flange C C () Flange Width () + 1 E Max (C) FLNGES OU OF SQ. MX WE OFF CENER MX EPH NY CROSS SEC. ll Up to 12- Over 12- /16 is measured at center line of web, is measured parallel to flange, C is measured parallel to web * hrough 426 lbs/ft, over 426 lbs/ft, /16-. permissible variations in LENGH from Specified Length for Lengths Given 30-FOO N 30-FOO 24-Inch and Under in Nominal 3/8 plus 1/16 for each additional feet or fraction thereof 3/8 24-Inch in Nominal Length & Columns plus 1/16 for each additional feet or fraction thereof

merican Standard/Channel 1 * S Shapes () Flange Width () Max (C) Sections Nominal Size (Inches) OU OF SQURE PER INCH OF IN INCHES S Shapes 3-7 Over 7-14 Over 14 3/32- - - 1/16-3/32- - - /32- - - /32- - 1/32-1/32-1/32- Channel Shapes 3-7 Over 7-14 Over 14 3/32- - - 1/16-3/32- - - - - - /32- - 1/32-1/32-1/32- is measured at center line of web permissible variations in LENGH UP O 30 F (with 30 ft included) from Specified Length for Lengths Given 30 F O 40 F 40 F O 0 F (with 0 ft included) 0 F O 6 F (with 6 ft included) 6 F S Shapes & 2 es 2 es 2 es 2 es 2 es S Shapes &

H-Pile/Wide Flange/Standard/Channel Camber Sweep Camber Sweep Horizontal Surface W, HP Shapes permissible variations in Camber & sweep in Inches Length CMER SWEEP with flange width equal to or greater than 6 es ll x total length (in feet) with flange width equal to or greater than 6 es ll x total length (in feet) x total length (in feet) Certain sections with flange width approximately equal to depth & specified on order as columns 4 Ft. and Under Over 4 Ft. x total length (in feet) (with 3/8 max) x total length (in feet) 3/8 + other tolerances for H-pile & wide flange Variation in Weight ± 2.% of theoretical or published weight Ends out of Square 1/64 per of depth, or flange width if it is greater than depth other tolerances for Standard & Channel Variation in Weight ± 2.% of theoretical or published weight Camber x total length (in feet) Ends out of Square 1/64 per of depth, or flange width if it is greater than depth Sweep x total length (in feet)

ngles () Flange Width () E Nominal Size FLNGES OU OF SQ. MX WE OFF CENER MX L ngles 3-4 (including 4) Over 4-6 (including 6) Over 6-8 (including 8) - 3/32-3/128- * - - 3/128- * - 1-8- 3/128- * * 3/128- per = 1 degrees. permissible variations in LENGH from Specified Length for Lengths Given UP O 30 F (with 30 ft included) 30 F O 40 F 40 F O 0 F (with 0 ft included) 0 F O 6 F (with 6 ft included) 6 F L ngles - 3/4-1- 1-1 - L ngles - - - - - CMER straightness in Inches CMER HORIZONL SURFCE x total length (in feet) Sweep tolerances are subject to negotiation for the individual shapes involved.

Structural ees Generally, any w or s shape from 6 to 36 es in depth can be split to form tees ee ee Shape - ee Shape ee Shape Center Splitting Off-Center Splitting wo Lines of Cut Nominal W-Shape in Inches 6 to 16 es (excluding 16) 16 to 20 es (excluding 20) 20 to 24 es (excluding 24) 24 es and Over Variation from ee Over and Under in Inches /16 3/8 ll weight, length and ends out of square variations for split tees are the same as those applicable to the shape from which the tees are split. Straightness in Inches CMER x total length (in feet)