IXIAN-ORP ORP. Reads mV mV. Range. +/ 1mV. Accuracy. Calibration. Single point remotely through PLC or directly on board

Similar documents
Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

EZO ORP ORP. Reads mV mV. Range. +/ 1mV. Accuracy. 1 reading per sec. Max rate. Any type & brand. Supported probes.

Initial Power-Up Tests

Exercise 2: Temperature Measurement

User manual V1.0 RTB231 RTB232. RTD transmitter

ORP100 Sensor. Edition 1.0. User Manual

inc Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Channel 2 Temperature Transmitter Black (V-) Green (V-)

HC-220 PID Controller

W100/W600/W900 Controller ph Electrode Troubleshooting Guide

OPTISENS ORP 8590 Technical Datasheet

ph or ORP Transmitter

FC-33, DC SELECTABLE SIGNAL CONDITIONER

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM

Caution Notes. Features. Specifications. Installation. A3-L 3-axis Gyro User Manual V1.0

Technical Data Sheet. Sensoric 4-20 ma Transmitter Board

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

WIRELESS MODBUS GATEWAY WGW410

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Troubleshooting Guide for Aquatrac Smart AS and Flex

ph/orp Transmitter SIGNET

GE Fanuc IC695ALG600. Rx3i PacSystem

Process Calibrator. TechChek 820

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

EZO. Reads. Range / Accuracy. 1 reading per sec. Max rate. Any type & brand. Supported probes. 1, 2, 3 point. Calibration.

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

Modular Radio Telemetry System

Operating Instructions

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

WM1, WIND, W400, W100, W600: ORP Sensor Troubleshooting Guide (Electrode and Housing)

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

CONDUCTIVITY/ TDS METER + PH meter. Model : DCT2001

NPD - Nitrogen Phosphorus Detector

Signet ph/orp Electrodes General Purpose

GFL-1000 User Manual Ground Fault Locator

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

STX Stair lighting controller.

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

C 2030 חפר מיכשור ומערכות בע"מ טכנולוגיות לטיפול במים ושפכים מיכשור אנליטי למדידה ובקרת תהליכים OPERATOR'S MANUAL. 2- Wire E.C transmitter Din Rail

200, 201 Series Radio Telemetry Transmitters

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

ServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version.

Guidelines to Using a Three Phase Voltage Monitor

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

269 Troubleshooting Guide 11/4/98 1

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

OVEN INDUSTRIES, INC. Model 5C7-362

igeacom User Guide V2.0

Radio Control Installation and Operating Instructions System 4

XC-E6TCA-P Temperature control module User s manual

Modular Radio Telemetry System

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

Memosens CPS96D. Technical Information

Signet ph/orp Transmitter * *

When you have completed this exercise, you will be able to determine ac operating characteristics of a

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

1000TR. Instructions

PH METER OPERATION MANUAL. Model : PH-208

Operator Manual 1.4 FRACSIM MINI

The Instructions should be read, prior to commencing the installation, failure to follow these instructions will void your warranty.

DFM Repeater Service Manual A service guide for DFM Repeaters version RPT-5.3

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

Microprocessor Control Board Set Up Procedures (OR PLC)

Signet 9900 Transmitter

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

Signet 9900 Transmitter

PROCESS & TEMPERATURE CONTROLLERS

Please enter the identity code of your device here!

GE Fanuc IC695ALG312. Rx3i PacSystem

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

RB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver

CAMTO. Arc detecting relay. system. January Revised August D D1200

MODEL AT-10 ANALOG TRANSMITTER

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

DISSOLVED OXYGEN TRANSMITTER

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

CAST Application User Guide

User s Manual for Integrator Short Pulse ISP16 10JUN2016

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Operating Instructions

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Data Acquisition Modules/ Distributed IO Modules

Authors: Doug Bail, Angela Ziebell, Maria Triantis Figure 1 ph Electrode.

DNB Model To PLC. Liquid Level 4-20mA Output Transmitter

Signet ph/orp Electrodes

IVI STEP TYPES. Contents

Catalog

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

The Smallest, Quietest & Safest Garage Door Operator in the World!

Service Information System

Debugging a Boundary-Scan I 2 C Script Test with the BusPro - I and I2C Exerciser Software: A Case Study

RLT Rainfall Transmitter Instruction Manual

Ohm's Law and DC Circuits

Transcription:

V 1.2 Revised 5/29/18 IXIN-ORP ORP Transmitter Reads Range ccuracy Calibration Supported probes ORP -1900.0mV 1900.0mV +/ 1mV Single point remotely through PLC or directly on board ny type & brand uto Temp compensation N/ Mount 35mm Din rail Output 4 20m Operating voltage 14VDC 36VDC Electrically Isolated Yes Written by Jordan Press Designed by Noah Press This is an evolving document, check back for updates.

Table of contents Transmitter dimensions Wiring diagram Operating principle Mounting 3 4 5 7 Power connection ORP connection 4 20m connection 8 9 10 4 20m ORP transmission Reading 4 20m output with a multimeter PLC calibration node Fault detect line Calibration theory On-board calibration PLC calibration 4 20m calibration 4 20m High 4 20m Low Factory reset 11 12 13 14 15 15 16 17 18 19 20 Datasheet change log 21 2 Copyright tlas Scientific LLC

Transmitter dimensions 128mm (5 ) 8.5mm (0.3 ) 18.97mm (0.7 ) 35mm (1.37 ) 66.5mm (2.6 ) 27.6mm (1.08 ) 3 Copyright tlas Scientific LLC

Wiring diagram Connect to PLC output coil Connect to PLC input coil V1.0 tlas Scientific Industrial ORP Probe 4 Copyright tlas Scientific LLC

Operating principle ORP stands for oxidation/reduction potential. Oxidation is the loss of electrons and reduction is the gain of electrons. The output of the probe is represented in millivolts and can be positive or negative. Just like a v probe measures hydrogen ion activity in a liquid; an ORP probe measures electron activity in a liquid. The ORP readings represents how strongly electrons are transferred to or from substances in a liquid. Keeping in mind that the readings do not indicate the amount of electrons available for transfer. ph Probe ORP Probe 5 Copyright tlas Scientific LLC

When reading the ORP of a liquid that has very few electrons available for transfer, ORP readings can appear to be inconsistent. The water is unreactive and has only trace amounts of electron movement. These readings are equivalent to the readings you see with an unconnected multimeter. -234.6 Reading B 24.2 Reading B 606.9 Reading B 605.3 Reading B Tap water Tap water dd just a drop of bleach (which is an oxidizing agent) n ORP probe has a platinum tip that is connected to a silver wire, surrounded by silver chloride. That silver wire is then connected to a KCL reference solution. Because platinum is an unreactive metal it can silently observe the electron activity of the liquid without becoming apart of whatever reaction is occurring in the liquid. Silver wire Junction Silver chloride KCL reference solution Reference wire 6 Copyright tlas Scientific LLC

Mounting The IXIN ORP Transmitter is specifically designed to be mounted to a 35mm din rail. To detach the transmitter from the din rail, pull down on the din rail release notch. 35mm din rail Din rail release notch 7 Copyright tlas Scientific LLC

Power connection ny DC voltage from 14V 36V can be used to power the IXIN ORP Transmitter. The power connector is keyed differently and is larger than the other connectors. Power consumption table VDC 14 24 36 m 36 25 18 8 Copyright tlas Scientific LLC

ORP connection ny off the shelf two wire ORP probe can be used with the IXIN ORP Transmitter. Connecting the ORP probe in reverse order will not damage the probe however, the readings will be incorrect. 9 Copyright tlas Scientific LLC

4 20m connection Connecting the 4 20m data output to your PLC, allows the IXIN ORP Transmitter to communicate with your PLC. Connecting the 4 20m data output to your PLC is purely optional. Leaving it disconnected will have no effect on the IXIN ORP Transmitter s operation. 10 Copyright tlas Scientific LLC

4 20m ORP transmission The ORP value that is visible on the seven segment LED screen is also, simultaneously transmitted through the 4 20m data output. 225 Connecting the 4 20m data output to your PLC is purely optional. Leaving it disconnected will have no effect on the IXIN ORP Transmitter s operation. ORP to 4 20m equation PLC DC Resolution ORP -1900-500 -225 0 225 500 1900 m 10 BIT = 3.71 12 BIT = 0.92 16 BIT = 0.05 4 9.89 11.05 12 12.95 14.10 20 11 Copyright tlas Scientific LLC

Reading 4 20m output with a multimeter To debug the IXIN ORP Transmitter output, first connect it to a multimeter as shown. (make sure the multimeter is set to m ). Once properly connected, set the IXIN ORP Transmitter to calibrate to 225. Compare the reading on the mulitmeter to the chart below. 12.95 m m ORP m 225 12.95 12 Copyright tlas Scientific LLC

PLC calibration node Using the input connection marked 225 it s possible to use a PLC to fully calibrate the IXIN ORP Transmitter. This is particularly beneficial when using a PLC touch screen. Sending an output signal from the PLC to the ORP Transmitters 225 input connection will calibrate the device. The voltage used to trigger a calibration event should be the same voltage used to power the IXIN ORP Transmitter. Connecting to the PLC calibration node is purely optional. Leaving it disconnected will have no effect on the IXIN ORP Transmitter s operation. 13 Copyright tlas Scientific LLC

Fault detect line The connection marked F is the fault detect line. During normal operation the fault detect line will output a voltage equal to the voltage used to power the device. If the IXIN ORP Transmitter detects a problem the fault line will drop to 0 volts. When a fault is detected the fault LED will turn on. Normal operation (24V typical) Fault 0 Volts Example The IXIN ORP Transmitter is powered with 24V the F line will output 24V during normal operation. Events that will trigger the fault line to go to 0 volts disconnected 4 20m output. calibration in process. loss of power. Connecting to the fault detect line is purely optional. Leaving it disconnected will have no effect on the IXIN ORP Transmitter s operation. 14 Copyright tlas Scientific LLC

Calibration theory The tlas Scientific IXIN ORP Transmitter has a simple single point calibration protocol. Place the probe in the 225mV calibration solution (chemically known as Zobell's Solution). Wait for the readings to stabilize, then calibrate the transmitter. The calibration data is stored in the EEPROM, and will be retained even if the Transmitter is powered off. On-board calibration To begin the on-board calibration process, press and hold the middle gray button marked 225, for 1.5 seconds to calibrate to an ORP of 225mV. 1.5 seconds The display will flash: 225, after a few seconds the display will then flash: done. 15 Copyright tlas Scientific LLC

PLC calibration Using the input connection marked 225 it s possible to use a PLC to fully calibrate the IXIN ORP Transmitter. Setting the PLC s output to 200ms or more will trigger a calibration event. This is particularly beneficial when using a PLC touch screen. Calibrate 225 The voltage used to trigger a calibration event should be the same voltage used to power the IXIN ORP Transmitter. CL button press T1 CL Transmitter ( OUT ) Timer 1 200ms T1 calibration event will only trigger if the corresponding input pin has been held high for 200ms. Holding the line for more then 200ms will have no effect. 16 Copyright tlas Scientific LLC

4 20m calibration To ensure that the PLC is receiving the most accurate 4 20m signal the current output from the IXIN ORP Transmitter can be adjusted. The 4m signal and the 20m signal can both be adjusted independently. To enter 4 20m calibration mode press and hold the two blue buttons marked and B simultaneously for 1.5 seconds. 1.5 seconds 17 Copyright tlas Scientific LLC

4 20m High The display will flash: 4-20H (the H stands for high) The IXIN ORP Transmitter will now output exactly 20m, and your PLC should show an ORP of 1900. Use the gray (up) and blue B (down) buttons to adjust the 20m output so the ORP moves to 1899.9, then move it back up, so it is just hits 1900. When you have finished making adjustments, press the blue (save) button to confirm. The 20m offset will be permanently stored in memory. 1899.9 1900.0 Save 18 Copyright tlas Scientific LLC

4 20m Low The display will flash: 4-20L (the L stands for low) The IXIN ORP Transmitter will now output exactly 4m, and your PLC should show an ORP of -1900. Use the gray (up) and blue B (down) buttons to adjust the 4m output so the ORP moves to -1899.9, then move it back, so it is just hits -1900. When you have finished making adjustments, press the blue (save) button to confirm. The 20m offset will be permanently stored in memory. -1899.9-1900.0 Save 19 Copyright tlas Scientific LLC

Factory reset The IXIN ORP Transmitter can be reset to its default settings. To issue a factory reset, press and hold the gray and blue B buttons for three seconds. The display will flash: reset Cancel 3 seconds Press and hold the gray and blue B buttons again to confirm the factory reset. To cancel a factory reset, press the blue button. 20 Copyright tlas Scientific LLC

Datasheet change log Datasheet V 1.2 dded info about calibration data saved to EEPROM on pg 15. Datasheet V 1.1 Corrected typo on pg 16. Datasheet V 1.0 Revised enitre datasheet. 21 Copyright tlas Scientific LLC