EMR CORPORATION N. 25th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623)

Master Reference Unit

Signal Isolation Module. Instruction Manual SIM

TERMS OF SALE. Quotations & Orders

RF Sense SDR Receiver TR Switch Model MFJ-1708B-SDR. RF Sense SDR Receiver TR Switch Model MFJ-1708B-SDR-S CTRL CTRL AUX AUX +12V +12V - + DELAY DELAY

Precision Frequency To Voltage Converter Card

Pre-Filter. Brushless/ Sparkless Blower. HEPA Filter. Fluorescent Light

Copyright Teletronics International, Inc. Patent Pending

Instruction Manual Bandpass Cavity Filters 6 5/8 and 10 Diameter

Copyright Teletronics International, Inc. Patent Pending

Instruction Manual Series-Notch Cavity Filters 6 5/8 and 10 Diameter

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz

MFJ-2389 Compact 8 Band Vertical

UMC16B/UMC16BL. Wideband UHF Antenna Multicoupler INSTRUCTION MANUAL. Fill in for your records: Serial Number: Purchase Date:

Preliminary Data Sheet!

50 Ohm Components Brochure

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER

SSR-150xxx-40VL-12P-xC-xxxCS

MFJ Enterprises, Inc. 300 Industrial Park Rd Starkville, MS USA

SSR VL-12P-xC-NCS

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier

Easy-Link Plus Version 2.2

Model 1791 VHF Radio User's Manual

Multiplier and Divider Card

860 DSP & 860 DSPi Multifunction Interactive Cable Analyzer. Section VI: Appendix

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

Owner s Manual DKW-3 HT. Wireless VHF Microphone System

TRANSMITTER COMBINERS

Additional JFW Brochures

Gypsy Statement of Limited Warranty. Part 1 General Terms

User s Guide ASSISTIVE LISTENING SYSTEMS

Model 6360/6361. Ambulance Cot Fastener INSTALLATION/OPERATION INSTRUCTIONS. IMPORTANT Keep manual on file at all times.

Additional JFW Brochures

Digital Lighting Systems, Inc.

16 Port. RF Multicoupler User s Guide 16 PORT RFM

Broadband Current Probe Series Operation Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

P.O. BOX 1521 POLSON, MT SSR V-12C

Multi-Function Assemblies

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12

MFJ ENTERPRISES, INC.

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

TRANSMITTER COMBINERS

WARRANTY We at DigiTech are very proud of our products and back-up each one we sell with the following warranty:

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Current Probe Fixture Instruction Manual

MFJ-1886TR. Receive Loop Antenna INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

User s Guide FM Transmitter

Digital Lighting Systems, Inc.

V-9927A DIGITAL MULTI-TONE GENERATOR

Model 9302 Amplifier-Discriminator Operating and Service Manual

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Kryptonite Authorized Seller Program

M2M. Overview. volts DC. AC power.

Mirage B-320-G FEATURES

2006 MFJ ENTERPRISES, INC.

User s Guide Instructions for Installation and Operation

Distribution Amplifiers 1

Warranty Terms & Conditions

Datasheet of SAW Device

2013 MFJ ENTERPRISES, INC.

About JFW Industries, Inc.

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

MFJ ENTERPRISES, INC.

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

o-ring grease can be used to hold the o-ring in the groove during installation.

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

LRF120VPR1L. User Manual. Overview. GAMA Electronics, Inc.

MODEL 3810/2 Line Impedance Stabilization Network

INSTRUCTION MANUAL. Model BN-4000B. High Power Balun for Beams with Type SO-239. Construction. General Description. Mounting on Boom or Mast

14 CHANNEL FAMILY RADIO SYSTEM MODEL # FR142

Overview. Thank you for purchasing the Suhr Eclipse Dual Overdrive/Distortion Pedal.

INTRODUCTION The B-24-G is a VHF band high power linear amplifier designed for the 144 MHz band. It has a maximum output power of 50W.

RFI & EMI Components and Subsystems

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

Introduction. Specifications. Features. Controls. Model 103

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

CDT. Service and Installation Manual. Manual Revision Oct 2014

Datasheet of SAW Device

GTX 320A. Mode A/C Transponder. pilot s guide

MFJ ENTERPRISES, INC.

MFJ ENTERPRISES, INC.

Assistive Listening Systems. RX-6 User s Guide

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

RIOT DISTORTION USER GUIDE

Effective June 8, Canadian 2015 Parts Price List

MFJ SIGNAL ENHANCER II

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Operating Guide SMH 1525DT SMU 4525KT Technology Drive West Melbourne, FL RELM Wireless Corporation. All Rights Reserved CC OG 23

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

Advanced Test Equipment Rentals ATEC (2832)

Video/Audio Transmission System Series VA700. (formerly Series DVL4A)

3H Communication. Filters, Multiplexers, Switch Filter Banks and RF Front-End Assemblies. Relentless Innovations. Systems

Installation Instructions

o-ring grease can be used to hold the o-ring in the groove during installation.

MFJ ENTERPRISES, INC.

UTE MICROWAVE, INC Digital Catalog

Moveable Probe Thick Silver Plated

Transcription:

Practical & Compact EMR Corp. Systems Solutions for all LMR & PMR applications offering the most practical approach to full duplex combining in mobile and base station applications. These are single antenna systems. Each model includes transmitter combiner, receiver multicoupler and antenna duplexer. The systems are delivered ready for operation with no on-site tuning or adjustment needed. Loss figures are nominal. Losses and gains per individual channel can vary over filter bandwidth. EMR s Compact Integrated Combining Systems are available as 25 Watt (SYS-25), 50 Watt & 100 Watt systems. By using hybrid/ferrite technology a greater variety of difficult to combine frequencies can be used in the same compact system. Standard components provide economical products with reliable, uniform performance and quick delivery times. Contact the factory for systems in different frequency bands, with narrowed or expanded filter bandwidths and complex specialized combining. Product Features Available for up to 100 W Power Applications: VHF, UHF, 700 & 800 MHz Up to 8 CH: For 25 W, 4 for 50 &-100 W; VHF or UHF; Adjacent Channel Possible. Even 6.25 KHz Spacing! Suited for On-Site and Local Area: Industrial Applications for local area coverage. Compact Size: Only 3 RU Height (5.25 Vertical Height for 25 W, 2, 3 and 4 CH Version). TM TM Full Duplex: Ideal for New Digital RF Repeater Systems including idas, MOTOTRBO and NXDN R. Reduced Cost Costs Less Than $1,700 List Per repeater pair (4 CH 25 W Full Duplex System)! Contact Factory for Details: sales@emr.com SYS-25: 25 Watt / 4 Channel Model: UHF25341/SYS-25 OUR MISSION: TO PROVIDE HIGH QUALITY PRODUCTS, TECHNICAL EXCELLENCE & PRACTICAL ENGINEERING AT AN ECONOMICAL PRICE

138-300 MHz Model Number VHF24321/SYS-25 VHF24331/SYS-25 VHF24341/SYS-25 Frequency Band 150-174 MHz 150-174 MHz 150-174 MHz Number of Channels 2 3 4 Max. Input Power / CH 25 Watts 25 Watts 25 Watts TX Insertion Loss Typ (Note 1 & 2) 5.7 db 7.5 db 8.8 db Max. TX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz Max. RX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz TX-RX Stop Band Minimum (Note 3) 4.0 MHz 4.0 MHz 4.0 MHz TX-TX Isolation 50+ db 50+ db 50+ db TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 30+ db 30+ db 30+ db Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 34 db @ 150 MHz 34 db @ 150 MHz 34 db @ 150 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 3

138-300 MHz Model Number VHF24422/SYS-50 VHF24432/SYS-50 VHF24442/SYS-50 Frequency Band 150-174 MHz 150-174 MHz 150-174 MHz Number of Channels 2 3 4 Max. Input Power / CH 50 Watts 50 Watts 50 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db Max. TX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz Max. RX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz TX-RX Stop Band Minimum (Note 3) 4.0 MHz 4.0 MHz 4.0 MHz TX-TX Isolation 80+ db 80+ db 80+ db TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 60+ db 60+ db 60+ db Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 34 db @ 150 MHz 34 db @ 150 MHz 34 db @ 150 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 4

138-300 MHz Model Number VHF24522/SYS-100 VHF24532/SYS-100 VHF24542/SYS-100 Frequency Band 150-174 MHz 150-174 MHz 150-174 MHz Number of Channels 2 3 4 Max. Input Power / CH 100 Watts 100 Watts 100 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db Max. TX Passband (Note 3) 600 KHz 600 KHz 600 KHz Max. RX Passband (Note 3) 600 KHz 600 KHz 600 KHz TX-RX Stop Band Minimum (Note 3) 3.8 MHz 3.8 MHz 3.8 MHz TX-TX Isolation 80+ db 80+ db 80+ db TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 60+ db 60+ db 60+ db Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 34 db @ 150 MHz 34 db @ 150 MHz 34 db @ 150 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 5

300-512 MHz Model Number UHF25321/SYS-25 UHF25331/SYS-25 UHF25341/SYS-25 UHF25351/SYS-25 Frequency Band 300-650 MHz 300-650 MHz 300-650 MHz 300-650 MHz Number of Channels 2 3 4 5 Max. Input Power / CH 25 Watts 25 Watts 25 Watts 25 Watts TX Insertion Loss Typ (Note 1 & 2) 5.7 db 7.5 db 8.8 db 10.0 db Max. TX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz 1.0 MHz Max. RX Passband (Note 3) 1.0 MHz 1.0 MHz 1.0 MHz 1.0 MHz TX-RX Stop Band Minimum (Note 3) 4.0 MHz 4.0 MHz 4.0 MHz 4.0 MHz TX-TX Isolation 50 db Min. 55 db Typ. 50 db Min. 55 db Typ. 50 db Min. 55 db Typ. 50 db Min. 55 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db 70+ db ANT-TX Isolation 30 db Min. 35 Typ. 30 db Min. 35 Typ. 30 db Min. 35 Typ. 30 db Min. 35 Typ. Input Return Loss 20 db or better 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Yes Maximum Amplifier Gain 30 db @ 460 MHz 31 db @ 470 MHz 31 db @ 470 MHz 31 db @ 470 MHz Amplifier Gain Field Adjust Yes Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 6

300-512 MHz Model Number UHF25422/SYS-50 UHF25432/SYS-50 UHF25442/SYS-50 UHF25452/SYS-50 Frequency Band 300-650 MHz 300-650 MHz 300-650 MHz 300-650 MHz Number of Channels 2 3 4 5 Max. Input Power / CH 50 Watts 50 Watts 50 Watts 50 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db 10.2 db Max. TX Passband (Note 3) 1 MHz 1 MHz 1 MHz 1 MHz Max. RX Passband (Note 3) 1 MHz 1 MHz 1 MHz 1 MHz TX-RX Stop Band Minimum (Note 3) 4.0 MHz 4.0 MHz 4.0 MHz 4.0 MHz TX-TX Isolation 80+ db Min. / 90 db Min. 80+ db Min. / 90 db Min. 80+ db Min. / 90 db Min. 80+ db Min. / 90 db Min. TX-RX Isolation 70+ db 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db 70+ db ANT-TX Isolation 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Yes Maximum Amplifier Gain 30 db @ 460 MHz 30 db @ 460 MHz 30 db @ 460 MHz 30 db @ 460 MHz Amplifier Gain Field Adjust Yes Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 7

300-512 MHz Model Number UHF25522/SYS-100 UHF25532/SYS-100 UHF25542/SYS-100 UHF25552/SYS-100 Frequency Band 300-650 MHz 300-650 MHz 300-650 MHz 300-650 MHz Number of Channels 2 3 4 5 Max. Input Power / CH 100 Watts 100 Watts 100 Watts 100 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db 10.2 db Max. TX Passband (Note 3) 600 KHz 600 KHz 600 KHz 600 KHz Max. RX Passband (Note 3) 600 KHz 600 KHz 600 KHz 600 KHz TX-RX Stop Band Minimum (Note 3) 3.8 MHz 3.8 MHz 3.8 MHz 3.8 MHz TX-TX Isolation 80 db / 90 db Typ. 80 db / 90 db Typ. 80 db / 90 db Typ. 80 db / 90 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db 70+ db ANT-TX Isolation 60 db / 70 db Typ. 80 db / 90 db Typ. 80 db / 90 db Typ. 80 db / 90 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Yes Maximum Amplifier Gain 30 db @ 460 MHz 30 db @ 460 MHz 30 db @ 460 MHz 30 db @ 460 MHz Amplifier Gain Field Adjust Yes Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 8

764-806 MHz Model Number HUHF26321/SYS-25B HUHF26331/SYS-25B HUHF26341/SYS-25B HUHF26351/SYS-25B Frequency Band 764-806 MHz 764-806 MHz 764-806 MHz 764-806 MHz Number of Channels 2 3 4 5 Max. Input Power / CH 25 Watts 25 Watts 25 Watts 25 Watts TX Insertion Loss Typ (Note 1 & 2) 6 db 7.8 db 9 db 10.0 db Max. TX Passband (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz Max. RX Passband (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz TX-RX Stop Band Minimum (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz TX-TX Isolation 50+ db Min. / 55 db Typ. 50+ db Min. / 55 db Typ. 50+ db Min. / 55 db Typ. 50+ db Min. / 55 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db 70+ db ANT-TX Isolation 30+ db Min. / 35 db Typ. 30+ db Min. / 35 db Typ. 30+ db Min. / 35 db Typ. 30+ db Min. / 35 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Yes Maximum Amplifier Gain 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 9

764-806 MHz Model Number HUHF26422/SYS-50B HUHF26432/SYS-50B HUHF26442/SYS-50B HUHF26452/SYS-50B Frequency Band 764-806 MHz 764-806 MHz 764-806 MHz 764-806 MHz Number of Channels 2 3 4 5 Max. Input Power / CH 50 Watts 50 Watts 50 Watts 50 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db 10.2 db Max. TX Passband (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz Max. RX Passband (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz TX-RX Stop Band Minimum (Note 3) 12 MHz 12 MHz 12 MHz 12 MHz TX-TX Isolation 80+ db Min. / 90 db Typ. 80+ db Min. / 90 db Typ. 80+ db Min. / 90 db Typ. 80+ db Min. / 90 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db 70+ db ANT-TX Isolation 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. 60+ db Min. / 70 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Yes Maximum Amplifier Gain 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 10

764-806 MHz Model Number HUHF26522/SYS-100B HUHF26532/SYS-100B HUHF26542/SYS-100B Frequency Band 764-806 MHz 764-806 MHz 764-806 MHz Number of Channels 2 3 4 Max. Input Power / CH 100 Watts 100 Watts 100 Watts TX Insertion Loss Typ (Note 1 & 2) 6.0 db 7.8 db 9.0 db Recommended TX Passband (Note 3) 12 MHz 12 MHz 12 MHz Recommended RX Passband (Note 3) 12 MHz 12 MHz 12 MHz TX-RX Stop Band Minimum (Note 3) 12 MHz 12 MHz 12 MHz TX-TX Isolation 80+ db Min. / 90 db Typ. 80+ db Min. / 90 db Typ. 80+ db Min. / 90 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 60+ db typ. / 70 db min. 60+ db typ. / 70 db min. 60+ db typ. / 70 db min. Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 11

806-869 MHz Model Number HUHF26321/SYS-25C HUHF26331/SYS-25C HUHF26341/SYS-25C Frequency Band 806-869 MHz 806-869 MHz 806-869 MHz Number of Channels 2 3 4 Max. Input Power / CH 25 Watts 25 Watts 25 Watts TX Insertion Loss Typ (Note 1 & 2) 5.7 db 7.5 db 8.8 db Recommended TX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz Recommended RX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz TX-RX Stop Band Minimum (Note 3) 27 MHz 40.0 MHz 40.0 MHz TX-TX Isolation 50 db Min. 55+ db Typ. 50 db Min. 55+ db Typ. 50 db Min. 55+ db Typ. TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 30 db Min. 35+ db Typ. 30 db Min. 35+ db Typ. 30 db Min. 35+ db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 12

806-869 MHz Model Number HUHF26422/SYS-50C HUHF26432/SYS-50C HUHF26442/SYS-50C Frequency Band 806-869 MHz 806-869 MHz 806-869 MHz Number of Channels 2 3 4 Max. Input Power / CH 50 Watts 50 Watts 50 Watts TX Insertion Loss Typ (Note 1 & 2) 5.7 db 7.5 db 8.8 db Recommended TX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz Recommended RX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz TX-RX Stop Band Minimum (Note 3) 27 MHz 40.0 MHz 40.0 MHz TX-TX Isolation 80 db Min. 90 db Typ. 80 db Min. 90 db Typ. 80 db Min. 90 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 60 db Min. 70 db Typ. 60 db Min. 70 db Typ. 60 db Min. 70 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 22 db at 800 MHz 22 db at 800 MHz 22 db at 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 3.0 db 3.0 db 3.0 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13

806-869 MHz Model Number HUHF26522/SYS-100C HUHF26532/SYS-100C HUHF26542/SYS-100C Frequency Band 806-869 MHz 806-869 MHz 806-869 MHz Number of Channels 2 3 4 Max. Input Power / CH 100 Watts 100 Watts 100 Watts TX Insertion Loss Typ (Note 1 & 2) 5.7 db 7.5 db 8.8 db Recommended TX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz Recommended RX Passband (Note 3) 24 MHz 3.0 MHz 3.0 MHz TX-RX Stop Band Minimum (Note 3) 27 MHz 40.0 MHz 40.0 MHz TX-TX Isolation 80 db Min. 90 db Typ. 80 db Min. 90 db Typ. 80 db Min. 90 db Typ. TX-RX Isolation 70+ db 70+ db 70+ db RX-TX Isolation 70+ db 70+ db 70+ db ANT-TX Isolation 60 db Min. 70 db Typ. 60 db Min. 70 db Typ. 60 db Min. 70 db Typ. Input Return Loss 20 db or better 20 db or better 20 db or better TX Bandpass Filter (Note 3) Optional Optional Optional Receiver Multicoupler Amp Yes Yes Yes Maximum Amplifier Gain 22 db @ 800 MHz 22 db @ 800 MHz 22 db @ 800 MHz Amplifier Gain Field Adjust Yes Yes Yes Amplifier NF 2.8 db 2.8 db 2.8 db Standard Voltage Required 115 / 230 VAC 115 / 230 VAC 115 / 230 VAC Optional Voltages 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 13.6 / 24 / 48 VDC 14

ORDERING, TERMS & POLICIES ORDER PLACEMENT: All prices shown are list price, FOB factory (Phoenix Arizona - USA) and are subject to change without prior notice. Prices include domestic packaging and are exclusive of federal, state or local excise or sales taxes, duty or brokerage charges on export shipments. Unless otherwise negotiated freight will be prepaid and added to the invoice. OPERATING FREQUENCIES: Operating frequencies and power levels used in preparing EMR products are those provided by the customer. Errors in operating frequencies or power levels made by EMR will be corrected at no charge. Errors due to faulty information from the customer are subject to all shipping charges and any material and/or labor cost incurred by EMR Corporation to correct the order. TERMS OF SALE: Terms of sales are C.O.D., or Cash with Order unless other terms have been established prior to shipment. Open account status will be extended upon reasonable assurance of credit worthiness. Past due accounts are subject to a late charge of up to 2.0% monthly, beginning 30 days after the date of issuance of our valid invoices. ORDER ACCEPTANCE: An order is considered contractually valid when a purchase order is accepted by mail, telephone, facsimile or e-mail. Cancellations made less than 15 days prior to scheduled ship date may be subject to a cancellation charge. CLAIMS FOR SHIPPING LOSS OR DAMAGE: All shipments will be made via the customers specified mode of transportation. If coded best way the shipment will be consigned to the most economical, reliable commercial carrier. Insurance will be taken unless the customer specifically takes responsibility for shipping loss or damage. Although claims for loss are the responsibility of the consignee, EMR will assist in all ways in making claims and tracking for loss or damage to any of its shipment. MODIFICATION AND DELAYS: EMR reserves the right to make design changes or modifications to any of its products without specific prior notification provided that such modifications do not materially reduce the value or performance of the equipment concerned. EMR will not be responsible for delays in shipment occasioned by slow or interrupted deliveries to EMR of components, materials or processes necessary to the completion of any project as originally scheduled. PRODUCT RETURNS: Merchandise returned without having first obtained written acknowledgment from EMR may be rejected. Unless otherwise authorized, credit or refund will not exceeds 90% of originally invoiced amounts, and in no event shall include transportation costs. Return authorizations shall expire in 60 days unless otherwise specifically noted. MECHANICAL SEALS: EMR provides mechanical seals on many of its products. These seals insure that the unit has not been modified or tampered with once it has left the factory. Breaking these seals without consent from an authorized EMR Corporation engineer or technician may void the warranty policy stated below. STANDARD WARRANTY POLICY: EMR Corporation, hereinafter called EMR, warrants that all equipment of its manufacture shall be free from defects in design, material and workmanship for a period of 5 years from date of shipment unless otherwise covered by special warranty. If any such product, entirely or in part, fails to produce the performance as set forth in the brochure, quotations or literature provided by EMR, such product will be replaced or repaired at EMR s expense provided that the failure was not the result of alteration, misuse, tampering, misapplication, shipping damage or vandalism. If a product failure is found to be the fault of EMR the cost of transportation to the EMR factory and its return will be born by EMR. A reasonable charge for travel and subsistence costs will be invoiced when on-site repairs are necessary. Should EMR supply components not of its own manufacture, but specified by a customer, the warranty shall reflect the original manufacturers warranty, only. It is understood that this statement constitutes EMR s entire and only warranty, there being no other warranties expressed or implied in law or in fact, including implied warranties of fitness. In no event shall EMR be liable for damages, either direct or consequential, that may be occasioned by any defect in material, workmanship or product support. DESTINATION CONTROL STATEMENT: EMR Corporation strictly adheres to all laws and regulations of the United States Government regarding the export or re-export of our products outside the United States of America. EMR Corporation requires notification regarding the intention to export any products outside the United States of America. Information for the export or re-export requires country of ULTIMATE destination, purchasing individual(s), corporations, financial institution(s), shipping documentation, and shipping entities. This information must be disclosed and on file at EMR Corporation prior to any shipments in accordance with the Export Administration Regulations. Any action contrary to U.S. laws is strictly prohibited.