MONTRANO. Continuous monitoring system for power transformers

Similar documents
Why partial discharge testing makes good sense

The importance of partial discharge testing throughout the development and operation of power transformers

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

Advanced Test Equipment Rentals ATEC (2832)

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

New Techniques for the Monitoring of Transformer Condition

MPD 500. Partial Discharge Measuring System for Routine Test Applications

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Diagnostic testing of cast resin transformers

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

CP CU1. Coupling unit for line and ground testing

Primary Test Manager (PTM) Testing and management software for primary assets

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

TESTRANO 600 ordering information

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

PD Diagnostic Applications and TechImp solutions

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

MPD 600. High-End Measurement and Analysis System for Partial Discharges (PD)

ABB Power Products Service

PD Solutions. On-Line PD Measurement Devices

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

PHG 70 TD PD / PHG 80 TD PD

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Electrical Equipment Condition Assessment

Partial Discharge Monitoring and Diagnosis of Power Generator

Specialists in HV and MV test and diagnostics. Testing in Substations

CT Analyzer. Revolution in current transformer testing and calibration

WEIDMANN ELECTRICAL TECHNOLOGY NETA POWERTEST MARCH 2014 ELECTRICAL TECHNOLOGY. WEIDMANN DIAGNOSTIC SOLUTIONS INC. A Member of the WICOR Group

Partial discharge diagnostics on very long and branched cable circuits

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

TECHIMP Power Transformer Monitoring

Revision of C Guide for Application of Monitoring Equipment to Liquid Immersed Transformers and Components. Mike Spurlock Chairman

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

Onsite Mobile AC High Voltage Test System

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

APPLICATIONS OF ACOUSTIC LOCALIZATION TO ONLINE POWER TRANSFORMERS

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

Partial Discharge, Survey or Monitor?

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

MEDIUM & HIGH VOLTAGE

MPD 600. High-end partial discharge measurement and analysis system

Končar TMS - Bushing monitoring

Partial Discharge Monitoring of Power Transformers by UHF Sensors

Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages

Testing of 400 kv GIS

Dielectric analysis of high-voltage power transformers DIAGNOSIS ABSTRACT KEYWORDS. 1. Introduction

Cable testing and diagnostics

USING DAMPED AC VOLTAGES

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

INSULATION DIAGNOSIS OF HIGH VOLTAGE POWER CABLES

PARTIAL DISCHARGE MEASUREMENTS ON GENERATORS USING A NOISE GATING SYSTEM

MPD 600. High-end measurement and analysis system for partial discharges

TRANSFORMER SERVICES OUR KNOWLEDGE. YOUR EXPERTS.

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

BY JASON SOUCHAK, Megger

Dispersing the clouds gain clear insight into your bushings using advanced diagnostic methods

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Autotransformer Condition Monitoring Systems

The Generators and Electric Motor Monitoring and Diagnostics Systems

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

Control and Monitoring of Subsea Power Grid

HV AC TESTING OF SUPER-LONG CABLES

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

Software System for Finding the Incipient Faults in Power Transformers

ANSE VISUAL, developed within the

MPD 500. Partial discharge measurement system for routine test applications

MPD 600. High-end partial discharge measurement and analysis system

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

EI HIGH VOLTAGE INSULATION TESTING POLICY

SYSTEMS AND COMPONENTS FOR TRANSFORMER TESTING

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

Maintenance & Diagnosis Strategies. for. High Voltage Substations

Partial Discharge Theory, Modeling and Applications To Electrical Machines

TRAINING OVERVIEW EDUCATION IS POWER. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

Aspects of PD interpretation in HV power cables. by Edward Gulski, Piotr Cichecki, Rogier Jongen

In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC

IN HOUSE CALIBRATION OF PD DETECTOR SYSTEM FOR FIELD TEST RESULT RELIABILITY

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

PD Testing Considerations for MV Plant Cables

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Software for Partial Discharge and Localization

Diagnostic measurements on instrument transformers. Part II. A classification and overview of diagnostic measurements DIAGNOSIS EVENTS ABSTRACT

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

Session Number: 13 Application of Wireless Communication for Monitoring of Critical Infrastructure

Optimizing wind farms

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Transcription:

MONTRANO Continuous monitoring system for power transformers

Condition monitoring to extend transformer life Knowing the dielectric condition of insulation is vital Dielectric flashover of insulation in bushings and inside transformers is one of the most frequent causes of failure in power transformers. Bushings and windings often fail due to the aging of their insulation over many years of service. Aging insulation progressively degrades to the point that it can no longer withstand electrical stress. This can cause bushings to explode, transformer destruction and long outages for repair. Early detection prevents failures Damaged transformer after a bushing explosion The continuous monitoring of the dielectric state of bushing and transformer insulation is therefore essential for managing transformer health. It allows you to obtain continuous information about insulation condition status, to detect negative trends, and to plan corrective action early. Such online assessments ensure safe, reliable operation during the intended transformer service life. Capacitance (of bushings) Transient over-voltages (at bushings) Dissipation/ power factor (of bushings) Partial discharge (in bushings & tank) 2

MONTRANO at a glance Monitors critical defect indicators MONTRANO continuously monitors critical dielectric indicators of progressive insulation breakdown in power transformers: > Capacitance and dissipation/power factor of bushings > Transient over-voltages > Partial discharge (PD) in bushings and inside the transformer Reliable online results MONTRANO provides bushing capacitance and dissipation/ power factor monitoring with lab accuracy in the field. It achieves this by using absolute measurement references. Additionally, MONTRANO employs advanced noise suppression techniques for reliable PD source recognition. It also detects transients directly at the bushings to assess their impact on transformer health. Actionable data to optimize maintenance strategy MONTRANO provides you detailed trend data and early warnings well before failures occur. Using this actionable data, you can assess the risk of dielectric failure and optimize your maintenance strategy accordingly. Flexible system design & easy implementation MONTRANO can be implemented at any point of time during a transformer s lifetime. The system s modular design allows it to be easily customized and expanded to match your exact monitoring requirements. Web-based data access & visualization MONTRANO provides a web interface for convenient data access and monitoring system management from a central computer. It allows you to schedule monitoring, set alarm and warning thresholds and check system status. You can view data anytime to determine the actual dielectric condition of insulation in bushings and inside the transformer. Trend charts show you how their condition has changed over time. Complete expert support & advice You do not have to be a high-voltage expert to benefit from MONTRANO s powerful monitoring capabilities. Our dedicated team of HV engineers provides you complete guidance and support. This includes onsite consultations to evaluate your monitoring needs; system installation, setup and training; as well as data evaluation support. Your benefits > Continuous assessment of insulation state > Absolute C, DF/PF monitoring ensures lab accuracy in the field > Advanced noise suppression for reliable PD source detection > HV transients detected directly at bushings with complete waveform > Detailed trend data for modern transformer health management 3

One system for complete dielectric assessment MONTRANO system overview The complete MONTRANO monitoring system for power transformers includes a set of bushing tap adapters, UHF sensor, acquisition units, a central computer and monitoring software. The system can be customized and expanded over time to meet your exact monitoring needs. 1 Bushing tap adapters > Robust, modular design for different types of bushings > Safe and multiple redundant high-voltage protections > Synchronously captures signals for capacitance, dissipation/power factor, transient over-voltages and partial discharge (PD) > Built-in temperature sensor for temperature compensation of measured values 2 UHF sensor > Highly sensitive PD measurements inside the transformer > Operates in UHF frequency range > Results can be correlated to the bushing signals 1 1 1 3 2

3 Acquisition unit/transformer 5 Fiber optic communication > 4-channel, simultaneous acquisition of data from the bushing tap adapters and UHF sensor > Advanced signal processing for capacitance, dissipation/ power factor, transient over-voltages and PD calculation > Used to connect each acquisition unit to the central computer > Provides uninterrupted data transmission over long distances > Complete galvanic isolation eliminates electrical interference and ensures personal safety > Monitoring Control Unit (MCU) provides USB connection to the central computer 6 Central computer & monitoring software 4 Acquisition unit/reference > Provides reference signal for absolute capacitance, dissipation/power factor measurement > Connects with up to three voltage transformers or three power transformer reference bushings > State-of-the-art database system ensures long-term data storage and retrieval > Performs intelligent data post-processing to provide useful information about condition status > Manages monitoring parameters and defined thresholds for warning and alarm levels > Visualization and classification of events and trends > Accessible via web browser interface 6 4 5 5 5

Reliable and early detection of defects Capacitance & dissipation/power factor Typical defects in bushing insulation can be detected by changes in bushing capacitance and dissipation/power factor (DF/PF). Recordings are made by MONTRANO at the bushing taps to determine the state of the bushing insulation. MONTRANO uses the individual phases of a nearby voltage transformer as an absolute reference. The bushings of a second transformer can also be used alternatively for comparison. The provided accuracy allows you to use the recommended DF/PF reference values of your bushing supplier to determine bushing insulation condition. Transient over-voltage recording Transient over-voltages originate from nearby switchgear or events in the power grid. Due to their magnitude and frequency, they can cause stress to bushing and transformer insulation. MONTRANO detects transient over-voltages directly at the bushings where dielectric stress occurs. It records transients on all three phases, including their waveforms. This enables you to determine their impact on the transformer. The IEEE compliant export format is supported (COMTRADE C37.111-1999). Capacitance trending DF/PF trending Transient over-voltages with oscillations 1 Bushing aging Reference aging 2 Reducing the level of uncertainty Changes in grid unbalance (phase shifts) can have a misleading impact on relative measurements for capacitance and dissipation/power factor. MONTRANO reduces uncertainty by using measurement references to detect aging in individual bushings reliably. Using a voltage transformer reference provides an absolute measurement. Grid unbalance Bushing aging Reference aging 3 Bushing aging 1 Transformer Relative measurement Dual transformer comparison Voltage transformer reference Highest uncertainty Lowest uncertainty Relative measurement (bushing-to-bushing comparison) 6

ff Partial discharge detection Partial discharge (PD) reveals weak spots in the insulation caused by aging. It is a reliable early indicator of defects in dielectric insulation. MONTRANO monitors PD at the bushing taps and inside the transformer tank. The system uses synchronous, multi-channel recording. This captures not only PD signals in bushings but also inside the transformer, using non-conventional UHF methods. Advanced PD denoising and source separation using selectable center frequency, 3PARD and 3CFRD enable the system to effectively suppress external noise, like corona. Phase C Phase B Phase C Phase B Phase A Phase A PD diagrams of three phases without separation Measurements related to each other in a 3PARD diagram Separated PD activity 2 2 nd Transformer 3 Voltage transformer Transformer Transformer Dual transformer comparison Absolute measurement (voltage transformer reference) 7

Monitoring packages to fit your specific needs Choose the solution right for you The following MONTRANO monitoring packages are examples of possible system configurations. Our team of monitoring specialists can assist you in customizing the perfect monitoring solution, based on your needs. CPL 843 bushing tap adapter UVS 610 drain valve sensor UHF converter MONTRANO Package 1 > Capacitance, disipation/power factor, transients & partial discharge (PD) > Voltage transformer reference 3 1 1 MONTRANO Package 2 > Capacitance, disipation/power factor, transients & PD > Option A: bushing-to-bushing comparison, or > Option B: dual transformer comparison 3 1 1 6 2 2 MONTRANO Package 3 > Capacitance, disipation/power factor & transients > Voltage transformer reference 3 MONTRANO Package 4 > Capacitance, disipation/power factor & transients > Option A: bushing-to-bushing comparison, or > Option B: dual transformer comparison 3 6 User-friendly monitoring software The MONTRANO monitoring software is easy to use via a convenient web-based interface. It enables you to configure and schedule monitoring, set warning and alarm thresholds, and generate reports from a central computer. System configuration & control > Topology views of the monitored assets > Configuration of all monitoring-related parameters > Continuous measurement configurations 8

OMS 843 transformer acquisition unit OMS 843 VT reference acquisition unit MCU fiber optic bus controller Central computer & monitoring software 1 1 1 1 1 2 1 1 1 1 1 1 1 2 1 1 Warnings and alarms > Defined threshold settings for alarm notifications > Real-time display of current alarm level > View of events that triggered alarm Data visualization > Trend charts show data for each monitored parameter > Data visualization for C, DF/PF, PD and transients > All data records and corresponding charts can be exported 9

Dedicated support for your monitoring needs Why OMICRON monitoring solutions are different MONTRANO is not only a set of excellent system components. Our knowledged experts are working for you to support you in all stages of your monitoring project. In simple words: We provide you with peace of mind while matching the actual needs of your HV equipment over its operational lifetime. High-quality support at every stage of your project We start the implementation of your monitoring system by understanding your needs and challenges. With this input, the system can be designed according to your needs. Our team of specialists then installs the system for you on-site. During the commissioning of the system, its performance and measurement sensitivity are verified. You are then trained on how to use the system and take maximum advantage of its features. The measured data is stored, processed and visualized by the monitoring software. Our high-voltage experts are available to help you interpret and analyze the data. We can also provide you regular asset condition reports and recommendations for further action. Flexibility Project-specific monitoring system design to match your requirements Competence On-site monitoring system installation, calibration & commissioning Knowledge Customer training in system operation and data analysis 10

Monitoring project knowledge and expertise you can rely on > Evaluation of monitoring requirements > Project-specific monitoring system design > Integration of monitoring system into existing infrastructure > Installation, commissioning and calibration of the monitoring system > Monitoring system and data evaluation training > Dielectric failure analysis and follow-up based on monitoring data > High-voltage expert assistance > Worldwide customer service & hotline Availability Worldwide customer support, system upgrades & HW/SW maintenance Expertise Support in condition assessment and data evaluation 11

OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete. Customers in more than 140 countries rely on the company s ability to supply leadingedge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry. For more information, additional literature, and detailed contact information of our worldwide offices please visit our website. www.omicron.at www.omicronusa.com OMICRON L2262, January 2014 Subject to change without notice.