ZEPHYR LDA. Laser Diffraction Alternative. m 3000 m. Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0)

Similar documents
COFFEE LABORATORY WHITE STONE VA Tel (804)

Particle size range (0.8 microns 1000 microns)

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)

Flow-Cell FC200S+ OCCHIO. The best solution for measuring suspensions,emulsions and foams

Morphologi. Advanced image analysis for high sensitivity particle characterization. Particle size. Particle shape

PICO MASTER 200. UV direct laser writer for maskless lithography

SUPRA Optix 3D Optical Profiler

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Thermo Scientific SPECTRONIC 200

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Technical Benefits of the

Huvitz Digital Microscope HDS-5800

DiaInspect-P. Operating manual. Version Page 1

SIEVE CERTIFICATION SYSTEM

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Thermo Scientific SPECTRONIC 200 Education

PAINT BORER 518 MC PAINTXPLORER 548

Chapter Ray and Wave Optics

Colony Imaging with powerful Analysis Software

OIW-Microscopy. 13 September Connor Douglas PhD

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

CANTY PROCESS TECHNOLOGY

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

Laser Speckle Reducer LSR-3000 Series

CAMSIZER. Particle Analyzer. Particle Size and Particle Shape Analysis with Dynamic Image Analysis

Advanced Test Equipment Rentals ATEC (2832)

PICO MASTER. UV direct laser writer for maskless lithography

T92+ UV-VIS SPECTROPHOTOMETER

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

INTERFEROMETER VI-direct

NanoMet Nanoparticle Diameter Example Report

COTTON FIBER QUALITY MEASUREMENT USING FRAUNHOFER DIFFRACTION

LAARMANN. Sieving Machines and Test Sieves. Innovators in Solids

Foreign Particulate Matter testing using the Morphologi G3

8.0. High precision solutions for cleanliness analysis CLEMEX PSFILTER. Accurate measurement of particulates as small as 0.

PRO. Flexo System Analyzer HD FLEXO NEW! NEW! Measure: Verify: Halftone Dot Area Screen Frequency Bar Code Line Width

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Automatic hardness testing devices

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

Information & Instructions

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

smart_projector State-of-the-art Video Measuring Machine

Quality Performance, Innovative Design

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

LightGage Frequency Scanning Technology

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Imaging Photometer and Colorimeter

Low Voltage Electron Microscope

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

University of Washington Molecular Analysis Facility

Infra Red Interferometers

Zeta-20. Zeta3D OPTICAL PROFILER IMAGING THE IMPOSSIBLE

LA-950 Laser Diffraction Analyzer

CrystalPro is a computer-controlled microscope with top quality optics.

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Product data sheet Palas Fidas 200 E

Smart_Projector. The Next Generation Profile Projector. State-of-the-art Video Measuring Machine NEW 2015 VERSION. 10 Mpx Industrial Camera

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Pulsed Fiber Laser on Flatbed Technology FP 100 / FP 300. High Performance Marking Solutions

Tunable KiloArc. Tunable Broadband Light Source.

8.0. High precision solutions for cleanliness analysis CLEMEX PSFILTER. Metallic and non-metallic particles analyzed in one step

Indian Institute of Technology Bombay

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer

Technical Explanation for Displacement Sensors and Measurement Sensors

Machine Vision Lyte-MV 2

USTER TESTER 5-S800. The yarn inspection system. Technical Data

Colony Imaging with powerful Analysis Software

Micro IRHD Laser revolution

PRECISION CUTTING MICRACUT 202

A broadband achromatic metalens for focusing and imaging in the visible

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

T:GENIUS GEL IMAGING AT A TOUCH

LI-1500 Light Sensor Logger

Home Lab 5 Refraction of Light

Fresnel Lens Characterization for Potential Use in an Unpiloted Atmospheric Vehicle DIAL Receiver System

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Submersible Microscope User Guide

MacroPATH The new line of Digital Imaging Systems for Grossing

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

VERTICAL FORM FILL SEAL MACHINES

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING)

Scanner Basic Configuration Part-No. 21R

OPTIV CLASSIC 321 GL TECHNICAL DATA

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Low Voltage Electron Microscope. Nanoscale from your benchtop LVEM5. Delong America

Low Voltage Electron Microscope

EQUIPMENT INFORMATION

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

Quality-Management. Portable micrograph laboratory Microlab ML 3002

For Isotropic Measurement of Magnetic and Electric Fields

Transcription:

Imaging particle analyzers 200 nm 5 cm ZEPHYR LDA Laser Diffraction Alternative m 3000 m Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0) 42 43 00 14

Imaging analyzers from 200 nm up to 3 cm ZEPHYR LDA: New particle size analyzer for particles, emulsions, foams... Since 2001, through the efforts of an international and multidisciplinary team of engineers, OCCHIO offers you a complete range of imaging particle analyzers, starting from 200 nanometers up to several centimeters. Whether it is for laboratory instrumentation, «AT LINE» or even «ON LINE» solutions, OCCHIO is prepared to be your partner in high-level powder characterization. OCCHIO bring you accuracy, profit and innovation. Based upon a combination of mechnical and vacuum dispersion, ZEPHYR LDA provides for fast and accurate size and shape analysis. It is used to substitute manual sieves analysis. Associated with the software CALLISTO, it is easy to use and carries out rapid analyses in few minutes. Dry dispersion by air flow Dry powders, which fall from a vibratory feeder, are introduced into a pipe and are dispersed by means of an aspiration system. Laminar air flow allows having all particles in focal plane. High resolution camera associated with telecentric lens allows taking perfect pictures. High resolution camera OCCHIO Instruments develops ZEPHYR LDA with one high resolution camera in order to obtain perfect correlation with other particle size technique as manual sieve analysis or laser diffraction. Subsitute manual sieve analysis Manual sieves analysis is long and need a full time operator. ZEPHYR LDA is working alone. Just put powder in feeder than ZEPHYR LDA measures. Glass cleaning New principle to have an automatic cleaning of glass plates. No sticked particles during analysis No need to clean optics after analysis DRY & WET ANALYSIS Sieves distribution Particle size and shape Particle counting with Flowcell (WET option) Kinetic mode Applications: Sugar, Coffee, Chocolate, Fiber, Tobacco, Sand, Diamond, PTFE, Ceramics, Fertlizers... Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0) 42 43 00 14

ZEPHYR LDA: CALLISTO TM Since 2001, OCCHIO develops revolutionary systems by image analysis technique to study all particles types (powders, suspensions, emulsions and foams). These new systems, associated to the powerful software CALLISTO TM, allow particle size measurements, shape analysis & particle counting. Now, more than 50 parameters are available PARTICLE SHAPE PARAMETERS PARTICLE SIZE PARAMETERS Area diameter Inner diameter - Length Width - Geodesic lenght - Mean diameter O. Aspect Ratio and Elongation: The Elongation is defined as 1-AspectRatio with AspectRatio being the ratio between the width and the length of the particle ISO Straightness: For very elongated particles, the straightness is ratio between the maximal distance and the Feret Length ISO Compactness and ISO Roundness : Compactness and roundness are related to the degree to which the particle is similar to a disc. Roundness is less robust than compactness ISO Circularity: Degree to which the particle (or its projection area) is similar to a circle ISO Solidity: Solidity is the object area divided by the area enclosed by the convex hull (perfect to detect aggregates ) O. Bluntness : The Bluntness Index is the expression of a maturity in the abrasion process O- Roughness: Amount of material to be removed from the shape before getting a smooth surface Luminance: The luminance is the mean greyscale level of the particle O-Porosity; Porosity estimator SCATTERPLOT: Possibility of having a representation of the particle size parameters versus morphologic estimators. According to the particle size classes chosen by the operator, all plots are corresponding to particles. Operator can visualize each particle in clicking on each plot. MICROSCOPE MODE: Display of each parameters and picture for selected particle on Scatterplot or live pictures. Operator can save picture for individual particle in Bitmap format. (Particle size & shape distribution, trends, Excel export, sieves correlation ) ZEPHYR LDA Options WET Analysis Autosampler Do not hesitate to contact us for other idea... Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0) 42 43 00 14

Model Particle size range Measurement time Parameters Dimensions and weight Disperser Optics and imaging device ZEPHYR LDA 7 microns 5000 microns 2 up to 10 minutes (sample depending) ISO 9276-6; 7; 8 norms + OCCHIO parameters SIZE: ISO Area diameter; ISO Inner diameter; Mean diameter; Perimeter diameter;crofton diameter; Half Crofton diameter; Width; Length; Ellipse Width; Ellipse Length; ISO Max Distance; ISO Geodesic Length; SHAPE: Occhio Bluntness; Occhio Roughness; Elongation; ISO Aspect Ratio; Ellipsoid Elongation; Ellipsoid Roundness; Ellipse Ratio; ISO Eccentricity ISO Straightness; ISO Roundness; ISO Compactness; ISO Extent; ISO Solidity; Convexity; ISO Circularity, Luminance mean Luminance var. 89.5(L) x 47 (l) x (H)38cm, 28 kg Vibrating feeder + vacuum principle Camera 5Mpixels Gigabit Ethernet Validation Option Computer specifications IQ,OQ,PQ in option Wet module, autosampler Windows 7, Intel Core i5-650 @3.2GHz, 4MB cache ; 4 GB @ 1156MHz, HD 500GB Thanks to contact OCCHIO to check computer specifications Power supply 110-240 V 50/60 Hz Working conditions Temperature 5 C 45 C, HR 35-80 % Images format Data storage Statistics tools (distribution in number & volume) Bitmap.oph binary Occhio files format contains:full size distribution valuesshape and size percentiles Outline and greyscale levels of each particle Acquisition info (short overview of the used SOP) ; Size distribution; Size percentiles; Shape percentiles; Shape distribution; Mean shape by size; 2D scatter-plot (fully selectable particles map); 3D scatter-plot (include animation); Percentiles sample images; Sample images (BMP exportable format); Id card for each particle (BMP exportable format); Morphological and size filtering procedure ; Raw data export (text format); Table distribution export (text format); Table distribution and percentile export (Excel format); Automatic or custom reporting; Full image export (bmp format); Single particle image export (bmp format); Figure and graph export(bmp format) Do not hesitate to contact us for more informations and to know about new developments YOUR DISTRIBUTOR * specification can be changed Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0) 42 43 00 14

Occhio LDA TECHNICAL DATASHEET Reference code: OCC164 Occhio LDA Technical specifications Working conditions Description Working temperature Temperature 5 C 45 C Humidity 35% - 80% non condensing Power Supply 100 or 220 Vac 50-60Hz (auto-switching is not available please ask to Occhio to set power supply) Computer (supplied by Occhio) Description Processor Intel Core i7-2600 @3.4GHz, 4MB cache Ram 4 GB @ 1600MHz Hard Disk 500MB Display LCD, FullHD, 22 Mouse, keyboard USB (English) Operating system Windows Seven professional Optics and imaging device Description Standard camera type Camera 5Mpixels Gigabit Ethernet 2/3 interline progressive scan CCD Camera resolution 5.0 Millions of pixels 2448 x 2050 pixels Pixel size 3.45 µm Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 1

Occhio LDA TECHNICAL DATASHEET Lens type Lens resolution (standard lens) (lens code 164-120-R1) Field of view (standard lens) (lens code 164-120-R1) Lens resolution (Optional lens) (lens code 164-121-R1) Field of view (Optional lens) (lens code 164-121-R1) Light source Light wavelength Telecentric lens Calibration : 10 µm/pixel 24480 x 20500µm @10µm/pixel Calibration : 7 µm/pixel 17136 x 14350µm @7µm/pixel Back light collimated monochromatic light source (wavelength 440nm) 440 nm (blue light) Dimensions Weight Dimensions and weight Description 85 x 64 x 47 cm (Width x Height x Deep) 52 kg Starting kit parts (these parts are included in the packing box at the delivery) Part number Description Quantity 164-081-R1 Glass plate 2 999-0014-R1* Vacuum cleaning (220VAC-240VAC) 1 999-0015-R1* Vacuum cleaning (110VAC) 1 999-0015-R1 Vacuum cleaning filter 1 164-500-R1 Zephyr and Zephyr ESR communication cable A 1 164-501-R1 Zephyr and Zephyr ESR communication cable B 1 999-0003-R1 Power supply cable North America 3 999-0004-R1 Power supply cable Europe 3 999-0013-R1** Computer + LCD, FullHD, 21.5 + Mouse + 1 Keyboard US 999-0010-R1 Keyboard USB (FR) 1 999-1016-R1 Calibrated quartz sand (Fr B 600µm 1180µm) Net weight 500g 1 bottle Option 164108 external wet dispersion module Dispersion beaker volume Flow type Cell thickness Description max 600 ml Circulation 1mm; 3mm; 6mm Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 2

Occhio LDA TECHNICAL DATASHEET Occhio LDA short instrument overview Based upon a combination of mechanical and vacuum dispersion, the Occhio LDA provided, for a fast and accurate size and shape analysis of sieveable powders. The instrument combines,high quality imaging system with a robust mechanical design for at-line and on-line process control. The powder is dispersed by means a vacuum system, different layers of air flow inside the pipe are maintained in laminar conditions. The area of image capture is close to the powder entry point to avoid differential speed. The system uses a unique combination of telecentric lens and collimated monochromatic light; therefore all particles are within the focus region. Sampling The sample is feed directly onto the Occhio LDA vibrating feeder and thanks to standard operation procedure analysis duration and cleaning time are automatically set, the measurement starts. Within a few seconds, results are displayed and database is generated. This instrument is able to analyze a large quantity of sample in just a few minutes due to the high-speed air flow. Typically, for plastic pellets 0.5-2.5 mm, sample flow is 500 grams/min. Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 3

Occhio LDA TECHNICAL DATASHEET All Occhio instruments are based upon specific optical technology, using high quality lenses with low distortion and mounted on a precision, robust mechanical system suitable for industrial working conditions. Sample analysis Model Sample dispersion Sample particles size range Time measurement Sample analysis Standard Operating Procedure includes Software mains features Model Size parameters (Iso 9276-6; 7; 8) All the size parameters are displayable or not according with the customer setting preference Shape parameters (Iso 9276-6; 7; 8) All the shape parameters are displayable or not according with the customer setting preference Occhio LDA Vibrating feeder combined with air flow From 7 µm to 5 mm 1-3 minutes (sample et quantity dependent) Size distribution cumulate and proportional curve Number distribution or volume weighted distribution Sieves correlation (according with OCCHIO) Maximum number of particles Control on vibrating feeder (initial speed, acceleration, max) Particles per picture Light intensity calibration Background calibration Creation of a particle database Image storage Filtering procedure Automatic reporting generation Callisto Software for Flowcell FC200M ISO Area diameter ISO Inner diameter Mean diameter Perimeter diameter Crofton diameter Half Crofton diameter Width Length Ellipse Width Ellipse Length ISO Max Distance ISO Geodesic Length Occhio Bluntness Occhio Roughness Elongation ISO Aspect Ratio Ellipsoid Elongation Ellipsoid Roundness Ellipse Ratio ISO Eccentricity ISO Straightness ISO Roundness Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 4

Occhio LDA TECHNICAL DATASHEET Advanced shape parameters Image format Data storage Data comparisons Plots and figure (By number or volume weighted values) Statistics tools Reporting and data export Microscope mode pane External images analysis ISO Compactness ISO Extent ISO Solidity Convexity ISO Circularity Luminance mean Luminance var. Porosity Developed in function of customer specifications Bitmap.oph binary Occhio files format contains: Full size distribution values Shape and size percentiles Outline and greyscale levels of each particle Open and compare more analysis on the same plots include trends graphic Acquisition info (short overview of the used SOP) Size distribution Size percentiles Shape percentiles Shape distribution Mean shape by size 2D scatter-plot (fully selectable particles map) 3D scatter-plot (include animation) Percentiles sample images Sample images (BMP exportable format) Id card for each particle (BMP exportable format) Morphological and size filtering procedure Raw data export (text format) Table distribution export (text format) Table distribution and percentile export (Excel format) Automatic or custom reporting Full image export (bmp format) Single particle image export (bmp format) Figure and graph export(bmp format) Real time images acquisition without analyzing Possibility to analyse images coming from others acquisition sources (bmp greyscale format) Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 5

Occhio LDA TECHNICAL DATASHEET OCCHIO SA 4 rue des chasseurs ardennais BELGIUM Tel :+32 43729330 Fax : +32 43652346 info@occhio.be www.occhio.be Ref. OCC164 (C) Copyright 2013 OCCHIO s.a. All rights reserved. 6

LDA WET SPECIFICATIONS Reference code: OCC169 LDA WET LDA WET allows making particle size, shape and counting analysis in WET mode. Particle size range (1 µm 3000 µm) Working conditions Description Working temperature Temperature 5 C 45 C Humidity 35% - 80% non condensing Power Supply 100 or 220 Vac 50-60Hz (auto-switching is not available please ask to Occhio to set power supply) Computer (supplied by Occhio) Description Processor Intel Core i7-2600 @3.4GHz, 4MB cache Ram 4 GB @ 1600MHz Hard Disk 500MB Display LCD, FullHD, 22 Mouse, keyboard USB (English) Operating system Windows Seven or 8 Instrument dimensions, weight and power supply Dimensions (WxDxH) 700mm x 420mm x 440mm (H include upper stirrer) Weight 26 Kg Power supply type External power supply module (delivered with the instrument) Input 100 to 240 VAC 50 to 60 Hz Output 5 12 24 VDC 200W Optical configuration and sample size range Camera résolution 5 megapixels Lens type Bitelecentric motorized zoom Lens resolution Position 1 : 13.8 µm/pixel Ref. OCC164 (C) Copyright 2015 OCCHIO s.a. All rights reserved. 1

LDA WET SPECIFICATIONS Image size (WxL @ resolution) Back light wavelenght Position 2 : 6.9 µm/pixel Position 3 : 3.45 µm/pixel Position4 : 1.725 µm/pixel 33.8 x 28.3 mm @ 13.8 µm/pixel 16.9 x 14.1@ 6.9 µm/pixel 8.4 x 7.1 @ 3.45 µm/pixel 4.2 x 3.5 @ 1.725 µm/pixel 440 nm Sample size range, sample dispersion and flow-cell size Sample dispersion In water or ethanol (for others solvents please contact Occhio) Sample type Suspension or emulsion Sample size range 1 µm to 3000 µm (sample and sample preparation dependent) Beaker material Stainless steel Beaker volume Min 500 ml Max 700ml Flow mode Circulation with centrifugal pump Pump speed (rpm) Min 200 Max 3000 Flow-cell material Stainless steeel Flow-cell thickness Spacer 1: 1mm thickness x 40.5 mm large Spacer 2: 2mm thickness x 40.5 mm large Spacer 4: 4mm thickness x 40.5 mm large Spacers material Stainless steel Stirrer type Upper brushless stirrer Stirrer speed (rpm) Min: 100 Max: 500 Software mains features Model Size parameters (Iso 9276-6; 7; 8) All the size parameters are displayable or not according with the customer setting preference Callisto Software ISO Area diameter ISO Inner diameter Mean diameter Perimeter diameter Crofton diameter Half Crofton diameter Width Length Ellipse Width Ref. OCC164 (C) Copyright 2015 OCCHIO s.a. All rights reserved. 2

LDA WET SPECIFICATIONS Shape parameters (Iso 9276-6; 7; 8) All the shape parameters are displayable or not according with the customer setting preference Advanced shape parameters Image format Data storage Data comparisons Plots and figure (By number or volume weighted values) Statistics tools Reporting and data export Ellipse Length ISO Max Distance ISO Geodesic Length Occhio Bluntness Occhio Roughness Elongation ISO Aspect Ratio Ellipsoid Elongation Ellipsoid Roundness Ellipse Ratio ISO Eccentricity ISO Straightness ISO Roundness ISO Compactness ISO Extent ISO Solidity Convexity ISO Circularity Luminance mean Luminance var. Porosity Developed in function of customer specifications Bitmap.oph binary Occhio files format contains: Full size distribution values Shape and size percentiles Outline and greyscale levels of each particle Open and compare more analysis on the same plots include trends graphic Acquisition info (short overview of the used SOP) Size distribution Size percentiles Shape percentiles Shape distribution Mean shape by size 2D scatter-plot (fully selectable particles map) 3D scatter-plot (include animation) Percentiles sample images Sample images (BMP exportable format) Id card for each particle (BMP exportable format) Morphological and size filtering procedure Raw data export (text format) Table distribution export (text format) Table distribution and percentile export (Excel format) Automatic or custom reporting Full image export (bmp format) Single particle image export (bmp format) Ref. OCC164 (C) Copyright 2015 OCCHIO s.a. All rights reserved. 3

LDA WET SPECIFICATIONS Microscope mode pane External images analysis Figure and graph export(bmp format) Real time images acquisition without analyzing Possibility to analyse images coming from others acquisition sources (bmp greyscale format) OCCHIO SA 4 rue des chasseurs ardennais BELGIUM info@occhio.be www.occhio.be Ref. OCC164 (C) Copyright 2015 OCCHIO s.a. All rights reserved. 4