wenlok.com.mx Switched-mode and uninterruptible power supplies, and electronic fuses Let s connect. Power supply Catalogue 2015/2016

Similar documents
General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

Datasheet. PRO-M Series Power Supplies

Data sheet Functional Electronics PRO-M. Power supplies for space-saving use in automation technology

Power supply CP-E 24/2.5

QUINT-PS/ 3AC/24DC/10

MINI-PS AC/24DC/1.3

Power supply CP-E 24/20.0

QUINT-PS/ 3AC/24DC/40

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Type CP-S, CP-C & CP-A Switch mode

QUINT-PS-24DC/24DC/10

Power supply CP-E 24/0.75

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

CP-T range Product group picture

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

QUINT-PS AC/24DC/40

Power supply CP-T 24/40.0 Primary switch mode power supply

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Switching power supplies CP range, Linear power supplies CP-L range. Content

Power supply CP-T 48/5.0 Primary switch mode power supply

CP-E range Benefits and advantages

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

CP-T range Benefits and advantages

Primary switch mode power supplies Product group picture

QUINT-PS/ 1AC/24DC/20

Power supply CP-D 24/1.3

Power supply CP-D 12/2.1

No-wear isolation of potentials in terminal block design

MINI-PS AC/2X15DC/1

Short-circuit-proof switching amplifier for inductive loads up to 10 A

For Immediate Delivery call KMParts.com at (866)

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Electronic timer CT-TGD.22

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

EPSITRON Advanced Power Supply System. High-Performance Meets High-Efficiency

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

SITOP power supply: The standard for reliability, compactness, and functionality. Reliably supplies 24 V DC.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

TRIO-PS-2G/1AC/24DC/5

Power Supplies 3. SDN-C Compact DIN Rail Series

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

05/09/2012

Output Voltage* (nom.)(adjustable)

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

PHOENIX CONTACT - 09/2009

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Power Supplies. SCL Series. Features. Related Products. Applications

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

08/07/2015

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relay CM-PFS

Electronic timer CT-SDD.22

Single or parallel use selectable by user Adjustable output voltage. New narrow width saves panel space

02/11/2015

02/11/2015

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Industrial Power Supplies

Liquid level monitoring relay CM-ENS.2x

Output Voltage nom. (adjustable)

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

08/07/2015

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Switching Power Supply Type SPP1 60W Enclosed type

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-MFS.21

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

CB Scheme UL508 UL ATEX II3G

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Smart Power Relay E I...

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Solid-State Soft Starters

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Transcription:

Switched-mode and uninterruptible power supplies, and electronic fuses Catalogue 2015/2016 Let s connect. Power supply

Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses Catalogue 4.3 Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses Uninterruptible power supplies (UPS) Fuse protection for 24 V DC circuits Unregulated power supplies Electrical cabinet socket outlet Contents B C D E ppendix Glossary/Technical appendix Index Index Type / Index Order No. ddresses worldwide W X I

Product overview wenlok.com.mx Power supplies Overview connectpower 1ph PROeco connectpower 3ph PROeco connectpower PROeco diode modules Single-phase switched-mode power supply modules Slim design Large temperature range from 25 C to 70 C Three-coloured LED indicators for simple error detection dvanced visual warning at 90 % rated output current International approvals 3-phase switched-mode power supply modules Slim design Large temperature range from 25 C to 70 C Three-coloured LED indicators for simple error detection dvanced visual warning at 90 % rated output current International approvals Diode module for 100 % decoupling of switched-mode power supply modules Optimum doubling of output power Redundancy operation Up to 40 output current can be set International approvals connectpower 1ph PROmax connectpower 3ph PROmax connectpower PRO-M Extension modules Single-phase switched-mode power supply modules Very slim design High degree of efficiency Power category 70...1,000 W Up to five devices can be connected in parallel without a diode module International approvals 3-phase switched-mode power supply modules Very slim design High degree of efficiency Power category 120...1,000 W Up to five devices can be connected in parallel without a diode module International approvals Capacity module for increasing the peak current Diode modules for redundant construction Relay module for monitoring the output voltage connectpower PRO-M pplication solutions connectpower 1ph PRO-H connectpower PRO-H Multi-phase Wide-range input 85...264 V C 80...430 V DC larm relay Metal snap-on foot International approvals Single-phase switched-mode power supplies High MTBF values Cl. I Div. 2 + TEX Performance class: 70 to 600 W : 12, 24, 36 and 48 V DC Multi-phase switched-mode power supplies 85...132 / 187...550 V C UL approval Performance class: 180 to 600 W II

Product overview connectpower PRO-H Redundancy modules connectpower PRO-E connectpower 1ph INSTPOWER 15 or 25 100 % load sharing Remote On/Off International approvals Cl. I Div. 2 + TEX Wall mounting Flat design Metal housing Performance classes from 25 W to 350 W Universal input and output voltages Single-phase switched-mode power supply modules for the distribution board Compact form Power category 24 and 48 W Universal input and output voltage 5 48 V International approvals connectpower 1ph WVEPOWER connectpower DC/DC converters connectpower UPS control unit Single-phase switched-mode power supply unit Slim design 22.5 mm Power category 12 W International approvals Compact form Metal housing Universal input and output voltage of 5 V to 48 V International approvals Two 24 V models in 10 /20 and 40 Temperature-compensated charging feature, for a long battery life Integrated battery diagnostics including continuous availability test Status relay and additional transistor outputs for remote monitoring Convenient LED displays for easy error analysis connectpower battery module connectpower buffer module compactpower 1ph unregulated power supplies Maintenance-free, lead-acid batteries from 1.3 h to 17 h Integrated temperature sensor for optimal battery charging Integrated fuse for reliable activation Support capacity up to 40 / 30 min or 10 / 90 min Robust metal housing for wall mounting Maintenance-free UPS on a capacitor basis, with a capacity to support 20 / 200 ms Parallel switching to increase the output current or support time Status notification via LED and relay contact Single-phase unregulated power supplies Compact form Standard voltage ~230/400 V to IEC 38 +/ 15 V tap Reliable short-circuit and overload protection III

Product overview wenlok.com.mx Power supplies Overview compactpower 3ph unregulated power supplies WVEGURD Electrical cabinet socket outlet 3-phase unregulated power supplies Compact form Nominal voltage to IEC 38 +/- 5 V tap Reliable short-circuit and overload protection Electronic fusing Visual fault indication and potential-free contact Reset input Compact form Simple installation in electrical cabinet TS 35 module can be rail mounted VDE mark of conformity Two-pole with earthing contact IV

V

Product overview wenlok.com.mx Find the perfect product to meet your requirement Our extensive portfolio of power supplies at a glance Series / family side side dditional functions Recommendation for application Order No. Page PROeco.4 PROmax.14 PRO-H.30 Description Phases C input voltage [V] DC input voltage [V] Rated voltage [V] Rated current [] Power rating [V] Derating at [ C] Power boost [60 s] Status relay Side-by-side connectability Temperature range [ C] Efficiency [%] MTBF time [Mh] Surge category Field cabinets Small and series machine construction Machine construction and plant manufacture Simple process applications Process industry Energy technology Power distribution Marine engineering PRO ECO 72 W 24 V 3 1 85 264 80 370 24 3 72 NO 87 1469470000 PRO ECO 120 W 24 V 5 1 85 264 80 370 24 5 120 NO 87 1469480000 PRO ECO 240 W 24 V 10 1 85 264 80 370 24 10 240 NO 90 1469490000 PRO ECO 480 W 24 V 20 1 85 264 80 370 24 20 480 NO 91 % 1469510000 PRO ECO 960 W 24 V 40 1 85 264 80 370 24 40 960 NO 93 1469520000 PRO ECO3 120 W 24 V 5 3 340 575 450 870 24 5 120 NO 25 87 1469530000 PRO ECO3 240 W 24 V 10 3 340 575 450 870 24 10 240 > 55 NO to 88 > 0.5 II 1469540000 PRO ECO3 480 W 24 V 20 3 340 575 450 870 24 20 480 NO +70 89 1469550000 PRO ECO3 960 W 24 V 40 3 340 575 450 870 24 40 960 NO 90 1469560000 PRO ECO 72 W 12 V 6 1 85 264 80 370 12 6 72 NO 90 1469570000 PRO ECO 120 W 12 V 10 1 85 264 80 370 12 10 120 NO 90 1469580000 PRO ECO 240 W 48 V 5 1 85 264 80 370 48 5 240 NO 90 1469590000 PRO ECO 480 W 48 V 10 1 85 264 80 370 48 10 480 NO 90 1469610000 PRO MX 72 W 24 V 3 1 85 277 80 370 24 3 72 CO 90 1478100000 % PRO MX 120 W 24 V 5 1 85 277 80 370 24 5 120 CO 90 1478110000 PRO MX 180 W 24 V 7,5 1 85 277 80 370 24 7.5 180 CO 91 1478120000 PRO MX 240 W 24 V 10 1 85 277 80 370 24 10 240 CO 91 1478130000 PRO MX 480 W 24 V 20 1 85 277 80 370 24 20 480 CO 25 91.5 1478140000 PRO MX 960 W 24 V 40 1 85 277 80 370 24 40 960 CO to 92.5 1478150000 PRO MX3 120 W 24 V 5 3 3 x 320 3 x 575 450 800 24 5 120 120% CO +70 90 1478170000 PRO MX3 240 W 24 V 10 3 3 x 320 3 x 575 450 800 24 10 240 CO 91 1478180000 > 60 > 0.5 III PRO MX3 480 W 24 V 20 3 3 x 320 3 x 575 450 800 24 20 480 300% CO 91.5 SEMI F47 1478190000 PRO MX3 960 W 24 V 40 3 3 x 320 3 x 575 450 800 24 40 960 @ 1 s CO Start-up 92.5 1478200000 PRO MX 70 W 5 V 14 1 85 277 80 370 5 14 70 CO @ 86 1478210000 PRO MX 72 W 12 V 6 1 85 277 80 370 12 6 72 CO 40 C 89 1478220000 PRO MX 120 W 12 V 10 1 85 277 80 370 12 10 120 CO 89 1478230000 Cl1Div2 PRO MX 240 W 48 V 5 1 85 277 80 370 48 5 240 CO 91 1478240000 PRO MX 480 W 48 V 10 1 85 277 80 370 48 10 480 CO 91.5 u 1478250000 Some not yet awarded PRO MX 960 W 48 V 20 1 85 277 80 370 48 20 960 CO 92.5 (status July 2014) 1478270000 CP T SNT 70 W 12 V 6 1 85 264 n/a 12 6 70 NO 82 1105430000 CP T SNT 140 W 12 V 12 1 85 132/187 264 n/a 12 12 140 NO 85 1105440000 CP T SNT 90 W 24 V 3.8 1 85 264 n/a 24 3.8 90 NO 85 % 1105790000 CP T SNT 90 W 24 V 3.8 CL2 1 85 264 n/a 24 3.8 90 NO 85 1194410000 CP T SNT 180 W 24 V 7.5 1 85 132/187 264 n/a 24 7.5 180 NO 88 1105810000 CP T SNT 360 W 24 V 15 1 85 132/187 264 n/a 24 15 360 NO 87 1105820000 25 CP T SNT 600 W 24 V 25 1 85 132/187 264 n/a 24 25 600 NO 89 1105840000 > 40 to > 1.8 II CP T SNT 90 W 48 V 2 1 85 264 n/a 48 2 96 NO 87 1194420000 +70 CP T SNT 180 W 48 V 4 1 85 132/187 264 n/a 48 4 192 NO 90 1105850000 CP T SNT 360 W 48 V 7.5 1 85 132/187 264 n/a 48 7.5 360 NO 89 1105860000 CP T SNT 600 W 48 V 12.5 1 85 132/187 264 n/a 48 12.5 600 NO 91 1105870000 CP T SNT2 180 W 24 V 7.5 1.2 85 132/187 550 n/a 24 7.5 180 NO 88 1194480000 Cl1Div2 CP T SNT2 360 W 24 V 15 1.2 85 132/187 550 n/a 24 15 360 NO 88 1194490000 CP T SNT2 600 W 24 V 25 1.2 85 132/187 550 n/a 24 25 600 NO 88 1194310000 NO = NO contact CO = CO contact Start-up @ 40 C = In the range of 40 to 25 C the device starts, but some technical parameter may differ (i. e., ripple-voltage). VI

Product overview Series / family dditional functions Order No. Page Description C input voltage [V] DC input voltage [V] Rated voltage [V] DC/DC.68 djustable range [V] Rated current [] Power rating [W] Status relay Parallel connection option Side-by-side connectability Temperature range [ C] (all CE) CP DCDC 250 W 24 V 10 18 31.2 24 22.5 29.5 10 240 5 1313320010 CP DC BUFFER 24 V 20 22.5 30 24 20 480 25 to +70 1251220000 CP DC UPS 24 V 20 /10 20 30 U in 0.3 V 20/10 480/240 1370050010 USV.39 B.4 Ergänzungsmodule.23.12 CP DC UPS 24 V 40 20 30 U in 0.3 V 40 960 1370040010 CP BTTERY 24 V DC 1,3 h 24 10 / 11.3 min. 1.3 h 2 1406930000 CP BTTERY 24 V DC 3,4 h 24 10 / 11.3 min. 3.4 h 2 0 1251070000 CP BTTERY 24 V DC 7,2 h 24 10 / 26.5 min. 7.2 h 2 to 1251080000 CP BTTERY 24 V DC 12 h 24 10 / 51 min. 12 h 2 +40 1251090000 CP BTTERY 24 V DC 17 h 24 10 / 81 min. 17 h 2 1251110000 CP T RM 10 (PRO-H redundancy module) 24 24 24 27 15 25 to 1105880000 CP T RM 20 (PRO-H redundancy module) 24 24 24 27 25 +70 1105890000 CP DM 10 (diode module) 10 40 U IN 0.7 10 10 8710620000 to CP DM 20 (diode module) 10 40 U IN 0.7 20 +55 8768650000 CP M DM 20 (diode module) 18 30 U IN 0.7 20 5 1222210000 25 CP M DM 40 (diode module) 18 30 U IN 0.7 40 5 to 1222220000 +70.24 CP M CP (capacity module) 18 30 U IN 40 /1 ms 5 1222240000 INSTPOWER.60 CP SNT 24 W 28 V 1 85 265 120 300 28 1 28 9928890028 CP SNT 24 W 24 V 1 85 265 120 300 24 1 24 20 9928890024 CP SNT 24 W 15 V 1,5 85 265 120 300 15 1.5 22.5 to 9928890015 CP SNT 24 W 12 V 1,5 85 265 120 300 12 1.5 18 +50 9928890012 CP SNT 24 W 5 V 2 85 265 120 300 5 2 10 9928890005 CP SNT 25 W 5 V 5 85 264 110 370 5 4 8 5 25 3 8754960000 CP SNT 48 W 12 V 4 85 264 110 370 12 9 15 4 48 3 10 8754970000 to CP SNT 48 W 24 V 2 85 264 110 370 24 15 28 2 48 3 +70 8739140000 CP SNT 48 W 48 V 1 85 264 110 370 48 46 55 1 48 3 8879230000 VII

VIII

Contents Overview.2 connectpower PROeco.4 connectpower PROmax.14 connectpower PRO-H.30 connectpower PRO-E.44 connectpower INSTPOWER.60 connectpower WVEPOWER.67 connectpower DC/DC converter.68.1

Overview wenlok.com.mx The switch-mode power supplies feature a high degree of efficiency, compact dimensions and minimal heat generation. They are an excellent, reliable solution for providing power in all automation applications safely providing 24 V DC voltage. The different product series are optimised for the automation industry: they feature Ex approvals for the processing industry, a flat shape perfect for distribution tasks within buildings, or provide decentralised control voltages. ll-purpose usage: with a wide range of C/DC inputs, single-, double- or three-phase versions, and a wide temperature range. dditional performance increases are possible using simple parallel circuitry. Weidmüller switch-mode power supplies can be depended upon for all applications because of their high efficiency and their resistance to both short circuits and overloads. Weidmüller offers a system of one- and three-phase swtichmode power supplies especially for the PROmax family. These can be expanded with additional modules to create whole system solutions. The appropriate system can be assembled for any type of application: with redundancy circuits containing decoupled outputs, monitoring of the output voltage or triggering of circuit breakers..2

Overview C / DC International use wide-range input (both DC as well as C voltages can be used; no switching required) and extensive approvals (UL/CS and GL (EMC 1 bridge)). Parallel connection connectpower Module power can be increased by connecting upto five power supplies in parallel without diode module. connectpower PROeco Narrow connectpower PROmax from 33 mm Space-saving configuration in the switching cabinet through very narrow housing construction and side-by-side connectability. connectpower PRO-H Robust Wide temperature range from 25 C +70 C. connectpower PRO-E Wide choice The right power supply for every application: 1-phase 3, 5, 7.5, 10, 20, 40 and 3-phase 5, 10, 20, 40. connectpower INSTPOWER connectpower WVEPOWER connectpower DC/DC converters.3

connectpower PROeco wenlok.com.mx PROeco power supplies with basic functionality and a high level of reliability Single- and three-phase switched-mode power supply units Slim design Large temperature range from 25 C to 70 C The output voltage can be precisely adjusted via the potentiometer on the front Remote monitoring via integrated status relay Three-coloured LED indicators for simple error detection dvanced visual warning at 90 % rated output current International approvals Derating curves Ioutput (% IN) Ioutput (% IN) 480 Watt 120 100 80 60 40 20 0 25 0 20 30 40 50 60 70 mbient temperature ( C) 960 Watt 120 100 80 60 40 20 0 25 0 20 30 40 50 60 70 mbient temperature ( C) General technical data % \ Ž mbient temp. operating / storage temperature 25 C +70 C / 40 C +85 C Max. perm. air humidity (operation) 5 % 95 % RH Degree of protection IP 20 Class of protection I, with PE connection Pollution degree 2 Insulation voltage input/output 3 kv E/ / 2 kv E/earth / 0.5 kv /earth MTBF > 500.000 h acc. to IEC 1709 (SN29500) Parallel connection option yes, max. 5 without diode module Housing version metal, corrosion resistant Mounting position, installation notice horizontal on mounting rail TS35, 50 mm spacing top and bottom for free air circulation Short-circuit protection Yes, automatic restart Overload protection Yes, IU characteristic curve Overtemperature protection Yes, automatic restart EMC / shock / vibration Noise emission acc. to EN55022 Class B Noise immunity tests acc. to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN61000-4-6 (conducted), EN61000-4-11 (Dips) Limiting of mains voltage harmonic currents cc. to EN61000-3-2 Resistance against vibration and shock 1 g acc. to EN50178, shock: 15 g in all directions Electrical safety (applied standards) Electrical equipment of machines cc. to EN60204 Safety transformers for switched-mode power units cc. to EN61558-2-17 Machinery with electronic equipment cc. to EN50178 / VDE0160 Safety extra-low voltage SELV acc. to EN60950-1, PELV acc. to EN60204-1 Protective separation / protection against electrical shock VDE0100-410 / acc. to DIN57100-410 Protection against dangerous shock currents cc. to VDE0106-101.4

connectpower PROeco connectpower PROeco PRO ECO 72W 24V 3 PRO ECO 120W 24V 5 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 0,55 @ 230 V C / 1,04 @ 110 V C 0,22 @ 370 V DC / 0,68 @ 120 V DC Yes / max. 40 2 / DI, safety fuse 6, Char. B, circuit breaker 2...4, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 3 at 55 C 3 @ 55 C, 2,25 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 87 % 4 W / 9.5 W 1 m > 0.5 @ 230 V C / > 0.53 @ 115 V C > 100 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 34 / 125 mm / 578 g CE; TUEV (EN/IEC 60950-1); culus; RCM 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 1,26 @ 230 V C / 2,24 @ 110 V C 0,39 @ 370 V DC / 1,16 @ 120 V DC Yes / max. 40 4 / DI, safety fuse 6, Char. B, circuit breaker 3...5, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 5 at 55 C 5 @ 55 C, 3,75 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 87 % 4 W / 15 W 1 m > 0.5 @ 230 V C / > 0.53 @ 115 V C > 80 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 40 / 125 mm / 680 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 3 for L/N/PE 5 (+,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 3 for L/N/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 Ordering data PRO ECO 72W 24V 3 1 1469470000 PRO ECO 120W 24V 5 1 1469480000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..5

connectpower PROeco wenlok.com.mx connectpower PROeco PRO ECO 240W 24V 10 PRO ECO 480W 24V 20 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 1,23 @ 230 V C / 2,47 @ 110 V C 1,18 @ 370 V DC / 2,4 @ 120 V DC Yes / max. 15 4 / DI, safety fuse 10, Char. B, circuit breaker 3...4, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 10 @ 55 C 10 @ 55 C, 7.5 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 90% 3 W / 24 W 1 m > 0.94 @ 230 V C / > 0.99 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 60 / 125 mm / 1026 g CE; TUEV (EN/IEC 60950-1); culus; RCM 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 2,37 @ 230 V C / 5,2 @ 110 V C 1,55 @ 370 V DC / 4,65 @ 120 V DC Yes / max. 5 6 / DI, safety fuse 16, Char. B, circuit breaker 6...8, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 20 @ 55 C 20 @ 55 C, 15 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 91% 5 W / 43 W 1 m > 0.98 @ 230 V C / > 0.98 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 3 120 / 100 / 125 mm / 1557 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 3 for L/N/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 3 for L/N/PE 7 (++,---,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 10 0.5 / 0.6 Ordering data PRO ECO 240W 24V 10 1 1469490000 PRO ECO 480W 24V 20 1 1469510000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..6

connectpower PROeco connectpower PROeco PRO ECO 960W 24V 40 Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 4,6 @ 230 V C / 9,9 @ 110 V C 2,9 @ 370 V DC / 9 @ 120 V DC Yes / max. 5 16 / DI, safety fuse 20, Char. B, circuit breaker 16, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 40 @ 50 C 40 @ 50 C, 24 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 93% 6 W / 76 W 1 m > 0.98 @ 230 V C / > 0.98 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 3 120 / 160 / 125 mm / 3019 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 3 for L/N/PE 7 (++,---,13,14) 0.5 / 6 0.5 / 16 0.5 / 2.5 2.5 / 10 26 / 12 22 / 8 0.5 / 0.6 Ordering data PRO ECO 960W 24V 40 1 1469520000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..7

connectpower PROeco wenlok.com.mx connectpower PROeco PRO ECO 72W 12V 6 PRO ECO 120W 12V 10 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 0.6 @ 230 V C / 1.1 @ 115 V C 0.25 @ 370 V DC / 0.7 @ 120 V DC Yes / max. 40 2 / DI, safety fuse 6, Char. B, circuit breaker 2...4, Char. C, circuit breaker 12 V DC ± 1 % 10...16 V (adjustable via potentiometer) 100 ms / < 50 mv ss @ 12 V DC, I Nenn 6 @ 55 C 6 @ 55 C, 4.5 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 85 % 4 W / 15 W 1 m > 0.5 @ 230 V C / > 0.53 @ 115 V C > 100 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 34 / 125 mm / 644 g CE; TUEV (EN/IEC 60950-1); culus; RCM 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 1.25 @ 230 V C / 2.25 @ 110 V C 0.4 @ 370 V DC / 1.2 @ 120 V DC Yes / max. 40 4 / DI, safety fuse 6, Char. B, circuit breaker 3...5, Char. C, circuit breaker 12 V DC ± 1 % 10...16 V (adjustable via potentiometer) 100 ms / < 50 mv ss @ 12 V DC, I Nenn 10 @ 55 C 10 @ 55 C, 7.5 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 87 % 4 W / 20 W 1 m > 0.5 @ 230 V C / > 0.53 @ 115 V C > 80 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 40 / 125 mm / 698 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 3 for L/N/PE 5 (+,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 3 for L/N/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 Ordering data PRO ECO 72W 12V 6 1 1469570000 PRO ECO 120W 12V 10 1 1469580000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..8

connectpower PROeco connectpower PROeco PRO ECO 240W 48V 5 PRO ECO 480W 48V 10 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 1.2 @ 230 V C / 2.4 @ 115 V C 1.2 @ 370 V DC / 2.4 @ 120 V DC Yes / Max. 10 4 / DI, safety fuse 10, Char. B, circuit breaker 3...4, Char. C, circuit breaker 48 V DC ± 1 % 42...56 V (adjustable via potentiometer) 100 ms / < 100 mv ss @ 48 V DC, I Nenn 5 at 55 C 5 @ 55 C, 3,75 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 92 % 5 W / 50 W 1 m > 0.94 @ 230 V C / > 0.99 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 5 100 / 60 / 125 mm / 1076 g CE; TUEV (EN/IEC 60950-1); culus; RCM 100...240 V C (wide-range input) 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 370 V DC (Derating @ 120 V DC) 2.4 @ 230 V C / 5.2 @ 110 V C 1.5 @ 370 V DC / 4.6 @ 120 V DC Yes / max. 3 6 / DI, safety fuse 16, Char. B, circuit breaker 6...8, Char. C, circuit breaker 48 V DC ± 1 % 42...56 V (adjustable via potentiometer) 100 ms / < 100 mv ss @ 48 V DC, I Nenn 10 @ 55 C 10 @ 55 C, 7.5 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 93% 3 W / 23 W 1 m > 0.98 @ 230 V C / > 0.98 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C yes, max. 3 120 / 100 / 125 mm / 1570 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 3 for L/N/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 3 for L/N/PE 7 (++,---,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.22 / 4 26 / 12 26 / 10 0.5 / 0.6 Ordering data PRO ECO 240W 48V 5 1 1469590000 PRO ECO 480W 48V 10 1 1469610000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..9

connectpower PROeco wenlok.com.mx connectpower PROeco PRO ECO3 120W 24V 5 PRO ECO3 240W 24V 10 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.3 @ 3 x 500 V C / 0.4 @ 3 x 400 V C 0.2 @ 800 V DC / 0.4 @ 450 V DC Yes / max. 40 2 / DI, safety fuse 2...3, Char. C, circuit breaker 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.6 @ 3 x 500 V C / 0.8 @ 3 x 400 V C 0.4 @ 800 V DC / 0.7 @ 450 V DC Yes / max. 50 2 / DI, safety fuse 2...3, Char. C, circuit breaker Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 5 at 55 C 5 @ 55 C, 3,75 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 87 % 6 W / 13 W 1 m > 0.55 @ 3 x 500 V C / > 0.65 @ 3 x 400 V C > 40 ms @ 3 x 500 V C / > 20 ms @ 3 x 400 V C yes, max. 5 100 / 40 / 125 mm / 710 g CE; TUEV (EN/IEC 60950-1); culus; RCM 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 10 @ 55 C 10 @ 55 C, 7.5 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 88% 6 W / 24 W 1 m > 0.55 @ 3 x 500 V C / > 0.65 @ 3 x 400 V C > 40 ms @ 3 x 500 V C / > 20 ms @ 3 x 400 V C yes, max. 5 100 / 60 / 125 mm / 971 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 4 for L1/L2/L3/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 4 for L1/L2/L3/PE 6 (++,--,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 / 0.6 Ordering data PRO ECO3 120W 24V 5 1 1469530000 PRO ECO3 240W 24V 10 1 1469540000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..10

connectpower PROeco connectpower PROeco PRO ECO3 480W 24V 20 PRO ECO3 960W 24V 40 Similar to illustration Similar to illustration Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Ramp-up time / Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Capacitive load Protection against inverse voltage Signalling Indication Floating contact / Contact load Relay on/off General data Degree of efficiency Power loss, idling / Power loss, nominal load Earth leakage current, max. Power factor (approx.) C failure bridging time @ I Nom Parallel connection option Depth x width x height / Weight 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 1.2 @ 3 x 500 V C / 1.5 @ 3 x 400 V C 0.7 @ 800 V DC / 1.2 @ 450 V DC Yes / max. 50 4 / DI, safety fuse 3...5, Char. C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 20 @ 55 C 20 @ 55 C, 15 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 89% 8 W / 48 W 1 m > 0.55 @ 3 x 500 V C / > 0.65 @ 3 x 400 V C > 30 ms @ 3 x 500 V C / > 20 ms @ 3 x 400 V C yes, max. 3 120 / 100 / 125 mm / 1495 g CE; TUEV (EN/IEC 60950-1); culus; RCM 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 2,15 @ 3 x 500 V C / 2,68 @ 3 x 400 V C 1,37 @ 800 V DC / 2,37 @ 450 V DC Yes / max. 40 6 / DI, safety fuse 10, Char. B, circuit breaker 6...8, Char, C, circuit breaker 24 V DC ± 1 % 22...28 V (adjustable via potentiometer) 100 ms / < 50 mv SS @ 24 V DC, I N 40 @ 50 C 40 @ 50 C, 24 @ 70 C unrestricted Yes LED green (U output > 21.6 V DC), LED yellow (I output > 90% I Rated typ. ), LED red (overload, overtemperature, short-circuit, U output < 20.4 V DC) Yes / max. 30 V DC / 1 voltage > 21.6 V / < 20.4 V, overload 90% 5 W / 95 W 1 m > 0.55 @ 3 x 500 V C / > 0.65 @ 3 x 400 V C > 25 ms at 3 x 500 V C / > 20 ms at 3 x 400 V C yes, max. 3 120 / 160 / 125 mm / 2899 g CE; TUEV (EN/IEC 60950-1); culus; RCM Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque range Nm 4 for L1/L2/L3/PE 7 (++,---,13,14) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 10 0.5 / 0.6 4 for L1/L2/L3/PE 7 (++,---,13,14) 0.5 / 6 0.5 / 16 0.5 / 2.5 2.5 / 10 26 / 12 22 / 8 0.5 / 0.6 Ordering data PRO ECO3 480W 24V 20 1 1469550000 PRO ECO3 960W 24V 40 1 1469560000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system..11

connectpower PROeco wenlok.com.mx connectpower PROeco diode module CP DM 10 CP DM 20 E1 E2 V V DC +V V E1 E2 V DC + +V -V +V -V E1 E2 -V E1 E2 -V voltage current voltage current General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Mounting position, installation notice Installation advice Weight 40 V DC max. 2 x 0...10 max. U in - 0.5 V typical 0...20 max. or 10 max. for redundancy operation -10 C...55 C -20 C...85 C 95.5% horizontally, on terminal rail TS 35 Clearance: side 2 cm; above/below 10 cm 399 g CE; culus; curus; EC 40 V DC max. 2 x 0...20 max. U in - 0.5 V typical 0...40 max. or 20 max. for redundant operations -10 C...55 C -20 C...85 C 97.5% horizontally, on terminal rail TS 35 Clearance: side 2 cm; above/below 10 cm 411 g CE; culus; curus; EC Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm 4 / 0.13 / 6 4 / 0.13 / 6 110 / 55.5 / 125 110 / 55.5 / 125 4 / 0.13 / 6 10 / 0.32 / 16 110 / 55.5 / 125 110 / 55.5 / 125 Ordering data CP DM 10 1 8710620000 CP DM 20 1 8768650000 ccessories.12

connectpower PROeco - ccessories Small metal foot Large metal foot Small plastic foot Large plastic foot Type Order No. MT 30 MF 1251320000 Type Order No. MT 45 MF 1251310000 Type Order No. MT 30 BK 1168970000 Type Order No. MT 45 BK 1962250000 Small wall mounting Large wall mounting Type Order No. CP WLLDPTER 30 MM 1461870000 Type Order No. CP WLLDPTER 45 MM 1461850000 Small screwdriver Type Blade type Size/F a b c Order No. SDIK PH1 1.00 80 9008570000 SDIS 0.5X3.0X100 B 0.5 3 100 9008380000 Markers End bracket For DIN rail TS 35 Type Colour Qty. Order No. SM 18/9.5 K MC NE WS white 200 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Order No. WEW 35/1 SW black 1.2 Nm 50 1162600000.13

connectpower PROmax wenlok.com.mx connectpower PROmax Derating curve Max. limiting average on state current [] Typ\Temp. 45 C 50 C 55 C 60 C 65 C 70 C 1ph 24 V / 3 3,6 3,3 3,2 3 2,6 2,2 1ph 24 V / 5 6 5,7 5,4 5 4,4 3,8 1ph 24 V / 7,5 9 8,5 8 7,5 6,6 5,6 1ph 24 V / 10 12 11,3 10,7 10 8,8 7,5 1ph 24 V / 20 24 22,6 21,4 20 17,6 15 1ph 24 V / 40 48 45,2 42,8 40 35,2 30 1ph 5 V / 14 16,8 15,8 15 14 12,3 10,5 1ph 12 V / 6 7,2 6,8 6,4 6 5,3 4,5 1ph 12 V / 10 12 11,3 10,7 10 8,8 7,5 1ph 48 V / 5 6 5,7 5,4 5 4,4 3,8 1ph 48 V / 10 12 11,3 10,7 10 8,8 7,5 1ph 48 V / 20 24 22,6 21,4 20 17,6 15 3ph 24 V / 5 6 5,7 5,4 5 4,4 3,8 3ph 24 V / 10 12 11,3 10,7 10 8,8 7,5 3ph 24 V / 20 24 22,6 21,4 20 17,6 15 3ph 24 V / 40 48 45,2 42,8 40 35,2 30 General technical data Current limiting > 120 % I N Insulation voltage input earth 3.5 kv Insulation voltage output earth 0.5 kv Insulation voltage input/output 4 kv Earth leakage current 3.5 m Series switching capability Yes mbient temp. operating / storage temperature / Start up -25 C...+70 C / -40 C...+85 C / -40 C Humidity at operating temperature 5...95 %, no condensation Class of protection / Pollution degree I / 2 MTBF >500,000h (25 C, IEC 61709) Housing version Metal, corrosion resistant Status indication LED red/green and relay ( 21.6 V DC LED green, relay on/ 20.6 LED red, relay off) Mounting position, installation notice Horizontal on TS35 mounting rail, with 50 mm of clearance at top and bottom for air circulation. Can be mounted side by side with no space in between. EMC / shock / vibration Noise immunity tests acc. to Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents EN55024; EN55022; IEC61000-3-2,-3; IEC61000-4-2,-3,-4,-5,-6,-8,-11 2.3 g / 30 g in all directions cc. to EN60204 cc. to EN61558-2-16 cc. to EN50178 / VDE0160 SELV acc. to EN60950, PELV acc. to EN60204, IEC61204 VDE0100-410 / acc. to DIN57100-410 cc. to VDE0106-101.14

connectpower PROmax connectpower PROmax PRO MX 72W 24V 3 PRO MX 120W 24V 5 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 V C / 1.5 @ 115 V C 1 @ 370 VDC / 1,5 @ 120 VDC Yes / max. 15 6, Char. B, circuit breaker, 3-5 Char. C, circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 VC / 2,5 @ 115 VC 1,5 @ 370 VDC / 2,5 @ 120 VDC Yes / max. 15 6, Char. B, circuit breaker, 6, char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 3 @ 60 C 3,6 @ 45 C, 2,25 @ 70 C 3.6 (1 min), 4.5 (4s) 9 (2ms) 89% > 0.90 @ 230 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 32 / 130 mm 650 g CE; culus; culusex; curus; EC; TUEV 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 5 @ 60 C 6.0 @ 45 C, 3,75 @ 70 C 6 (1 min), 7.5 (4s) 15 (2ms) 89% > 0.90 @ 230 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 40 / 130 mm 859 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 Ordering data PRO MX 72W 24V 3 1 1478100000 PRO MX 120W 24V 5 1 1478110000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.15

connectpower PROmax wenlok.com.mx connectpower PROmax PRO MX 180W 24V 7,5 PRO MX 240W 24V 10 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 V C / 2 @ 115 V C 1 @ 370 VDC / 2 @ 120 VDC Yes / max. 15 10, char. B circuit breaker, 6 8, char. C circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1.5 @ 230 V C / 3 @ 115 V C 1,5 @ 370 VDC / 3 @ 120 VDC Yes / max. 15 10, char. B circuit breaker, 6 8, char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 7,5 @ 60 C 9 @ 45 C, 5,6 @ 70 C 9 (1 min), 11.25 (4s) 22,5 (2ms) 91.5% > 0.95 @ 230 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 50 / 130 mm 950 g CE; culus; culusex; curus; EC; TUEV 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 10 @ 60 C 12 @ 45 C, 7,5 @ 70 C 12 (1 min), 15 (4s) 30 (2ms) 91.5% > 0.95 @ 230 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 60 / 130 mm 1050 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 Ordering data PRO MX 180W 24V 7,5 1 1478120000 PRO MX 240W 24V 10 1 1478130000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.16

connectpower PROmax connectpower PROmax PRO MX 480W 24V 20 PRO MX 960W 24V 40 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 2,3 @ 230 VC / 4,8 @ 115 VC 1,5 @ 370 VDC / 4.8 @ 120 VDC Yes / max. 15 16, Char. B circuit breaker, 10, char. C circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 4,52 @ 230 VC / 10 @ 115 VC 2,8 @ 370 VDC / 10 @ 120 VDC Yes / max. 15 20, char. B circuit breaker, 16, Char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 20 @ 60 C 24 @ 45 C, 15 @ 70 C 24 (1 min), 30 (4s), 100 240 V C 60 (2ms) 92 % > 0.95 @ 230 V C min. 20 ms 30 35 V DC yes, max. 3 150 / 90 / 130 mm 2000 g CE; culus; culusex; curus; EC; TUEV 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 40 @ 60 C 48 @ 45 C, 30 @ 70 C 48 (1 min), 60 (4s), 100 240 V C 120 (2ms) 93% > 0.95 @ 230 V C min. 20 ms 30 35 V DC yes, max. 3 150 / 140 / 130 mm 3900 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 16 0.22 / 4 0.5 / 16 26 / 10 22 / 8 0.8 x 4.0, PZ 1 1.0 x 5.5 Ordering data PRO MX 480W 24V 20 1 1478140000 PRO MX 960W 24V 40 1 1478150000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.17

connectpower PROmax wenlok.com.mx connectpower PROmax PRO MX 70W 5V 14 PRO MX 72W 12V 6 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 V C / 1.5 @ 115 V C 1 @ 370 VDC / 1,5 @ 120 VDC Yes / max. 15 6, Char. B, circuit breaker, 3-5 Char. C, circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 V C / 1.5 @ 115 V C 1 @ 370 VDC / 1,5 @ 120 VDC Yes / max. 15 6, Char. B, circuit breaker, 3-5 Char. C, circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 5 V DC 4.5...7 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 14 @ 60 C 16,8 @ 45 C, 10,5 @ 70 C 16.8 (1 min), 21 (4s) 42 (2ms) 86% > 0.90 @ 230 V C min. 20 ms > 7.5 V DC yes, max. 5 125 / 32 / 130 mm 650 g CE; culus; culusex; curus; EC; TUEV 12 V DC ± 1 % 10...15 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 6 @ 60 C 7.2 @ 45 C, 4.5 @ 70 C 7.2 (1 min), 9 (4s) 18 (2ms) 89% > 0.90 @ 230 V C min. 20 ms > 18 V DC yes, max. 5 125 / 32 / 130 mm 650 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 Ordering data PRO MX 70W 5V 14 1 1478210000 PRO MX 72W 12V 6 1 1478220000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.18

connectpower PROmax connectpower PROmax PRO MX 120W 12V 10 PRO MX 240W 48V 5 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1 @ 230 VC / 2,5 @ 115 VC 1,5 @ 370 VDC / 2,5 @ 120 VDC Yes / max. 15 6, Char. B, circuit breaker, 6, char. C circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 1.5 @ 230 V C / 3 @ 115 V C 1,5 @ 370 VDC / 3 @ 120 VDC Yes / max. 15 10, char. B circuit breaker, 6 8, char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 12 V DC ± 1 % 10...15 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 10 @ 60 C 12 @ 45 C, 7,5 @ 70 C 12 (1 min), 15 (4s) 30 (2ms) 89% > 0.90 @ 230 V C min. 20 ms > 18 V DC yes, max. 5 125 / 40 / 130 mm 850 g CE; culus; culusex; curus; EC; TUEV 48 V DC ± 1 % 30...56 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 5 @ 60 C 6.0 @ 45 C, 3,75 @ 70 C 5 (1 min), 7.5 (4s) 15 (2ms) 92.5% > 0.95 @ 230 V C min. 20 ms 58 65 V DC yes, max. 5 125 / 60 / 130 mm 1050 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 Ordering data PRO MX 120W 12V 10 1 1478230000 PRO MX 240W 48V 5 1 1478240000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.19

connectpower PROmax wenlok.com.mx connectpower PROmax PRO MX 480W 48V 10 PRO MX 960W 48V 20 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 2,3 @ 230 VC / 4,8 @ 115 VC 1,5 @ 370 VDC / 4.8 @ 120 VDC Yes / max. 15 16, Char. B circuit breaker, 10, char. C circuit breaker 100...240 V C (wide-range input) 85 277 V C 45 65 Hz 80...370 V DC 4,52 @ 230 VC / 10 @ 115 VC 2,8 @ 370 VDC / 10 @ 120 VDC Yes / max. 15 20, char. B circuit breaker, 16, Char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 48 V DC ± 1 % 30...56 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 10 @ 60 C 12 @ 45 C, 7,5 @ 70 C 12 (1 min), 15 (4s), 100 240 V C 60 (2ms) 93% > 0.95 @ 230 V C min. 20 ms 58 65 V DC yes, max. 5 150 / 90 / 130 mm 2000 g CE; culus; culusex; curus; EC; TUEV 48 V DC ± 1 % 30...56 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 20 @ 60 C 24 @ 45 C, 15 @ 70 C 24 (1 min), 30 (4s), 100 240 V C 60 (2ms) 94% > 0.95 @ 230 V C min. 20 ms 58 65 V DC yes, max. 5 150 / 140 / 130 mm 1350 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 3 for L/N/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 16 0.22 / 4 0.5 / 16 26 / 10 22 / 8 0.8 x 4.0, PZ 1 1.0 x 5.5 Ordering data PRO MX 480W 48V 10 1 1478250000 PRO MX 960W 48V 20 1 1478270000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.20

connectpower PROmax connectpower PROmax PRO MX3 120W 24V 5 PRO MX3 240W 24V 10 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 45 65 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0,28 @ 3*500 VC / 0,3 @ 3*400 VC 0.18 @ 800 V DC / 0.3 @ 450 V DC Yes / max. 15 2 3, char. C circuit breaker 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 45 65 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0,35 @ 3*500 VC / 0,4 @ 3*400 VC 0.35 @ 800 V DC / 0.6 @ 450 V DC Yes / max. 15 3-5 Char. C, circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 5 @ 60 C 6.0 @ 45 C, 3,75 @ 70 C 6 (1 min), 7.5 (4s), 400 500 V C 15 (2ms) 90% > 0.50 @ 3*400 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 40 / 130 mm 850 g CE; culus; culusex; curus; EC; TUEV 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 10 @ 60 C 12 @ 45 C, 7,5 @ 70 C 12 (1 min), 15 (4s) 30 (2ms) 91.5% > 0.85 @ 3*400 V C min. 20 ms 30 35 V DC yes, max. 5 125 / 60 / 130 mm 1350 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 4 for L1/L2/L3/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 6 0.22 / 4 0.5 / 4 26 / 10 26 / 12 0.8 x 4.0, PZ 1 0.6 x 3.5 4 for L1/L2/L3/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 Ordering data PRO MX3 120W 24V 5 1 1478170000 PRO MX3 240W 24V 10 1 1478180000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.21

connectpower PROmax wenlok.com.mx connectpower PROmax PRO MX3 480W 24V 20 PRO MX3 960W 24V 40 Rated input voltage voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) / Inrush current Recommended back-up fuse 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 45 65 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0,7 @ 3*500 VC / 0,85 @ 3*400 VC 0.7 @ 800 V DC / 1.2 @ 450 V DC Yes / max. 15 3-5 Char. C, circuit breaker 3 x 400...3 x 500 V C (wide-range input) 3 x 320...3 x 575 V C / 2 x 360...2 x 575 V C 45 65 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 1,3 @ 3*500 VC / 1,6 @ 3*400 VC 1.4 @ 800 V DC / 2.4 @ 450 V DC Yes / max. 15 6 8, char. C circuit breaker Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Continuous output current @ U Rated Power boost @ U Rated Pulsed current capacity @ U Rated General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Protection against reverse voltages from the load Parallel connection option Depth x width x height Weight 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 20 @ 60 C 24 @ 45 C, 15 @ 70 C 24 (1 min), 30 (4s) 60 (2ms) 91.5% > 0.85 @ 3*400 V C min. 20 ms 30 35 V DC yes, max. 3 150 / 70 / 130 mm 1600 g CE; culus; culusex; curus; EC; TUEV 24 V DC ± 1 % 22.5...29.5 V (adjustable via potentiometer) < 50 mvss @ U Nenn, Full Load 40 @ 60 C 48 @ 45 C, 30 @ 70 C 48 (1 min), 60 (4s), 400 500 V C 120 (2ms) 93.5% > 0.75 @ 3*400 V C min. 20 ms 30 35 V DC yes, max. 3 150 / 140 / 130 mm 3400 g CE; culus; culusex; curus; EC; TUEV Connection data Connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Screwdriver blade 4 for L1/L2/L3/PE 8 (++,---,11,13,14) 0.18 / 6 0.18 / 6 0.22 / 4 0.22 / 4 26 / 10 26 / 10 0.8 x 4.0, PZ 1 0.8 x 4.0, PZ 1 4 for L1/L2/L3/PE 8 (++,---,11,13,14) 0.18 / 6 0.5 / 16 0.22 / 4 0.5 / 16 26 / 10 22 / 8 0.8 x 4.0, PZ 1 1.0 x 5.5 Ordering data PRO MX3 480W 24V 20 1 1478190000 PRO MX3 960W 24V 40 1 1478200000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. ccessories.22

connectpower PROmax PRO-M: diode, capacity and relay modules CP M DM20 CP M DM40 1+ 3+ 4+ 11 12 14 1-2- 2+ 21 22 24 3-4- 1+ 3+ 4+ 11 12 14 1-2- 2+ 21 22 24 3-4- Rated input voltage / DC input voltage range current Rated output voltage / voltage Rated (nominal) output current @ U Nom continous output current @ 24 V DC Voltage monitoring / Floating contact Switching thresholds General data Degree of efficiency Depth x width x height / Weight mbient temperature (operational) / Storage temperature Humidity Protection degree / Class of protection / Pollution degree Insulation voltage MTBF Mounting position, installation notice EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to 24 V DC / 18 30 V DC 2 x 10 or 1 x 20 24 V DC ± 1 % / voltage - 0.7 V 20 @ 60 C 24 @ 45 C, 22.5 @ 55 C, 15 @ 70 C Yes, In both inputs / Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail > 97% @ 24 V input voltage 150 / 34 / 130 mm / 0.3 kg -25 C...70 C / -40 C...85 C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kv /output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. Class B EN 61000-4-2 (ESD) EN 61000-4-3 and EN 61000-4-8 (fields) EN 61000-4-4 (burst) EN 61000-4-5 (surge) EN 61000-4-6 (conducted) 24 V DC / 18 30 V DC 2 x 20 or 1 x 40 24 V DC ± 1 % / voltage - 0.7 V 40 @ 60 C 48 @ 45 C, 45 @ 55 C, 30 @ 70 C Yes, In both inputs / Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail > 97% @ 24 V input voltage 150 / 60 / 130 mm / 0.6 kg -25 C...70 C / -40 C...85 C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kv /output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. Class B EN 61000-4-2 (ESD) EN 61000-4-3 and EN 61000-4-8 (fields) EN 61000-4-4 (burst) EN 61000-4-5 (surge) EN 61000-4-6 (conducted) Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 1 g according to EN50178 / 15 g In all directions cc. to EN60204 cc. to EN50178 / VDE0160 SELV acc. to EN60950, PELV acc. to EN60204 ccsus; CE; culus; EC; GL; GOSTME25 4 (1+, 2+, 1-, 2-) 4 (3 +, 4 +, 3 -, 4 -) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 1 g according to EN50178 / 15 g In all directions cc. to EN60204 cc. to EN50178 / VDE0160 SELV acc. to EN60950, PELV acc. to EN60204 ccsus; CE; culus; EC; GL; GOSTME25 4 (1+, 2+, 1-, 2-) 4 (3 +, 4 +, 3 -, 4 -) 0.5 / 16 0.5 / 16 2.5 / 10 2.5 / 10 22 / 6 22 / 6 Ordering data Plastic clip-on foot Metal clip-on foot CP M DM20 1 1222210000 CP M DM20 1 1222210010 CP M DM40 1 1222220000 CP M DM40 1 1222220010 ccessories.23

connectpower PROmax wenlok.com.mx PRO-M: diode, capacity and relay modules CP M CP Pulse triggering for circuit breakers: with the Weidmüller capacitance module The following conditions apply to the table entries: mbient temperature of 20 C Inner resistance of the circuit breakers is taken into account Half of the rated current flows to a neighbouring circuit before the short circuit is formed DC-compatible circuit breakers: Siemens 5SY series 1+ 2+ 11 12 14 + Power supply + CP module Load 1-2- Distance in m Rated input voltage / DC input voltage range Peak current output / Recovery time for the capacitor Switching thresholds Floating contact General data Depth x width x height / Weight mbient temperature (operational) / Storage temperature Humidity Protection degree Class of protection Pollution degree Insulation voltage MTBF Mounting position, installation notice EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage 24 V DC / 18 30 V DC Depending on the load (typically 40 for 1 ms) / pprox. 1 sec. 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail Yes 150 / 34 / 130 mm / 0.4 kg -25 C...70 C / -40 C...85 C 5...95 %, no condensation IP 20 III, with no ground connection, for SELV 2 0.5 kv /output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. Class B EN 61000-4-2 (ESD) EN 61000-4-3 and EN 61000-4-8 (fields) EN 61000-4-4 (burst) EN 61000-4-5 (surge) EN 61000-4-6 (conducted) EN 61000-4-11 (dips) 1 g according to EN50178 / 15 g In all directions cc. to EN60204 cc. to EN50178 / VDE0160 SELV acc. to EN60950, PELV acc. to EN60204 CE; culus; EC; GL Fuse tripping Conductor cross section B6 B10 0.75 mm 2 10 m 1.0 mm 2 14 m 6 m 1.5 mm 2 20 m 9 m 2.5 mm 2 30 m 15 m 4 mm 2 50 m 24 m 6 mm 2 B16 0.75 mm 2 1.0 mm 2 1.5 mm 2 4 m 2.5 mm 2 6 m 4 mm 2 10 m 6 mm 2 16 m C2 C4 0.75 mm 2 11 m 6 m 1.0 mm 2 14 m 8 m 1.5 mm 2 21 m 12 m 2.5 mm 2 34 m 19 m 4 mm 2 32 m 6 mm 2 C6 C10 0.75 mm 2 3 m 1.0 mm 2 3.5 m 2 m 1.5 mm 2 5.5 m 3 m 2.5 mm 2 9 m 5 m 4 mm 2 14 m 8 m 6 mm 2 12 m Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 4 (++--) 3 (CO contacts) 0.5 / 6 0.5 / 6 0.5 / 4 0.5 / 2.5 26 / 12 26 / 12 For low-impedance connections we recommend 2.5. Ordering data Plastic clip-on foot Metal clip-on foot CP M CP 1 1222240000 CP M CP 1 1222240010 ccessories.24

.25

wenlok.com.mx connectpower PROmax PRO-M: pplication solution for wind power Switched-mode power supply with wide-range input pplication solution for wind power: 80... 430 V DC input larm contact Metal snap-on foot % { \u General technical data characteristic curve / current limit Earth discharge current mbient temperature (operational) / Storage temperature / Start-up Max. permitted humidity (operational) Degree of protection Class of protection Pollution degree Insulation voltage MTBF Protection against reverse voltages from the load Can be connected in parallel Housing version Signal indication Mounting position, installation notice Voltage derating 110 Pout [% Pn] 190 90 80 70 60 50 40 80 120 160 200 240 280 320 360 400 440 DC [V] Temperature derating 130 120 EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to Pout [% Pn] 110 100 90 80 70 60 20 30 40 50 60 mbient temperature [ C].26 70 80 Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Safety transformers for switched-mode power units Safety extra low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents IU / > 120 % IR < 3.5 m 25 C +70 C / 40 C +85 C / 40 C 5 % 95 % RH IP 20 I, with PE connection 2 3 kv C 1 min. / 2 kv C 1 min. / 0.5 kv C 1 min. > 500,000 h according to IEC 1709 (SN29500) 30 35 V DC Yes, without diode module Metal, corrosion resistant Operations, green/red LED Horizontal on TS 35 mounting rail, with 50 mm of clearance at top and bottom for air circulation. Can be mounted side by side with no space in between. Suitable for installation in rotating systems. Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) according to EN61000-3-2 according to EN50178, Shock: 5 g in all directions according to EN60204 according to EN61558-2-17 according to EN50178 / VDE0160 SELV according to EN60950, PELV according to EN60204 VDE0100-410 / according to DIN57100-410 according to VDE0106-101

connectpower PROmax PRO-M: application solutions for wind power CP M SNT 250W 24V 10 UW Rated input voltage / voltage range C Frequency range C DC input voltage range C current consumption DC current consumption fuse (internal) Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency Power factor (approx.) C failure bridging time @ I Nom Depth x width x height / Weight dditional equipment Status indicator Relay on/off 100...240 V C (wide-range input) / 85 264 V C (Derating @ 100 V C) 47...63 Hz 80 430 V DC 1.2 @ 230 V C / 2.4 @ 115 V C 0.8 @ 370 V DC / 2.3 @ 120 V DC Yes 4 / DI, safety fuse 10, Char. B, circuit breaker 3...4, Char. C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mv SS @ 24 V DC, I N, < 2,4 V SS @ 24 V DC, I N @ -40 C 10 @ 60 C 12 @ 45 C, 10.7 @ 55 C, 7.5 @ 70 C 90 % @ 230 V C / 87 % @ 115 V C > 0.99 @ 230 V C / > 0.97 @ 115 V C > 20 ms @ 230 V C / > 20 ms @ 115 V C 155 / 60 / 130 mm / 1.2 Kg Green LED, red LED voltage > 21.6 V / < 20.4 V CE; culus; EC; GL; GOSTME25; TUEV Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 6 (+,+,-,-,COM,NO) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 Ordering data CP M SNT 250W 24V 10UW 1 1165480010 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..27

connectpower PROmax - ccessories wenlok.com.mx Small metal foot Large metal foot Small plastic foot Large plastic foot Type Order No. MT 30 MF 1251320000 Type Order No. MT 45 MF 1251310000 Type Order No. MT 30 BK 1168970000 Type Order No. MT 45 BK 1962250000 Small wall mounting Large wall mounting Type Order No. CP WLLDPTER 30 MM 1461870000 Type Order No. CP WLLDPTER 45 MM 1461850000 Small screwdriver Large screwdriver Type Blade type Size/F a b c Order No. SDIK PH1 1.00 80 9008570000 SDIS 0.5X3.0X100 B 0.5 3 100 9008380000 Type Blade type Size/F a b c Order No. SDIS 1.0X5.5X125 B 1 5.5 125 9008410000 Markers Endwinkel For DIN rail TS 35 Type Colour Qty. Order No. SM 18/9.5 K MC NE WS white 200 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Order No. WEW 35/1 SW black 1.2 Nm 50 1162600000.28

.29

wenlok.com.mx connectpower PRO-H connectpower PRO-H % { \ CB Scheme L (+) N ( ) C DC PE General technical data Current limiting mbient temp. operating / storage temperature Max. perm. air humidity (operation) Degree of protection / Class of protection Pollution degree Insulation voltage input/output MTBF according to IEC 61709 + + 13 14 DC OK Data Link > 100 % Irated -25 +70 C -25 C +85 C 95 % RH IP 20 / I, with PE connection 2 4 kv I/O 2 kv I/earth 0.5 kv O/earth CP T 70/90 W > 1.8 Mio. h CP T 140 W > 1.2 Mio. h CP T 180/360/600 W > 0.9 Mio. h 16 V DC / 35 V DC / 63 V DC yes, without diode module metal, corrosion resistant Thermal protection, autom. restart Unlimited, autom. restart Dual LED Operational: Green LED; Error: Red LED Horizontal on TS 35 mounting rail, with 80 mm space at top and bottom. Side by side mounting with 50 mm clearance. 7 mm Protection against reverse voltages from the load Parallel connection option Housing version Overload protection Short circuit protection Indication Mounting position, installation notice Stripping length (rated connection) Signal indication Power Good Signal Trigger point 12 V Version 9 11 V DC 24 V Version 18...22 V DC 48 V Version 36...44 V DC NO contact 30 V DC / 1.0 max. for 12/24 V DC modules 48 V DC/ 0.5 max. for 36/48 V DC modules 70 W 11 V DC ± 1 V DC / 20 m max. 140 W 11 V DC ± 1 V DC / 40 m max. 90 W 22 V DC ± 2 V DC / 10 m max. 180/360/600 W 24 V DC 22 V DC± 2 V DC / 20 m max. 180/360/600 W 48 V DC 44 V DC± 4 V DC / 15 m max. Potential free, floating signal contact ctive output signal Max. limiting average on state current [] Type\Temp. 1 ph 12 V / 6 1 ph 12 V / 12 1 ph 24 V / 3.8 1 ph 24 V / 7.5 1 ph 24 V / 15 1 ph 24 V / 25 1 ph 36 V / 16.5 1 ph 48 V / 2 1 ph 48 V / 4 1 ph 48 V / 7.5 1 ph 48 V / 12.5 1-2 ph 24 V / 7.5 1-2 ph 24 V / 15 1-2 ph 24 V / 25 40 C 6.0 12.0 3.8 7.5 15.0 25.0 16.5 2.0 4.0 7.5 12.5 7.5 15.0 25.0 50 C 5.7 9.5 3.1 6.3 12.5 22.5 15.0 1.6 3.3 6.3 11.3 6.3 12.5 22.5 60 C 5.4 7.0 2.5 5.0 10.0 20.0 13.3 1.3 2.5 5.0 10.0 5.0 10.0 20.0 70 C 4.5 3.7 1.7 3.3 6.7 13.3 9.0 0.8 1.7 3.3 7.5 3.3 6.7 13.3 EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) according to EN61000-3-2 3 axes, Sinus, 10 55 Hz, 1 g, 1 oct./min 3 axes, 15 g, half sinus, 11 ms Limiting of mains voltage harmonic currents Vibration IEC 60068-2-6 Shock IEC 60068-2-27 Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra low voltage according to EN60204 according to EN61558-2-4 according to EN50178 SELV according to EN60950 CP T SNT... 100 100 90 600 W 80 70 90 W 180 W 360 W 60 50 40-25 40 50 Temperature [ C].30 70 W 140 W 60 70 Power [% Pmax] Power [% Pmax] 90 80 70 60 50 40 85 90 100 110 115 132 187 230 264 Voltage [V C]

connectpower PRO-H connectpower PRO-H CP T SNT 70W 12V 6 CP T SNT 140W 12V 12 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100...240 V C (wide-range input) 85...264 V C 47...63 Hz 1 @ 230 V C, 2 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 12 V DC ± 1 % 12...14 V DC (adjustable via potentiometer on front) 100 mv SS @ 12 V DC, I nom 6 @ 40 C 6 @ 40 C, 5.4 @ 60 C, 4.5 @ 70 C typ. 82 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 35 / 110 mm 0.5 kg BVTEX; CE; CS; curus; EC; UL 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 1.4 @ 230 V C, 2.5 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 12 V DC ± 1 % 12...14 V DC (adjustable via potentiometer on front) 100 mv SS @ 12 V DC, I nom 12 @ 40 C 12 @ 40 C, 7 @ 60 C, 3.7 @ 70 C typ. 85 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 54 / 110 mm 0.7 kg BVTEX; CE; CS; curus; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 2 (+ / -) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 24 / 12 18 / 12 3 for L/N/PE 7 (+ / - / Signal) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 24 / 12 18 / 12 Ordering data CP T SNT 70W 12V 6 1 1105430000 CP T SNT 140W 12V 12 1 1105440000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.31

connectpower PRO-H wenlok.com.mx connectpower PRO-H CP T SNT 90W 24V 3.8 CP T SNT 90W 24V 3.8 CL2 Class 2, UL 1310 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100...240 V C (wide-range input) 85...264 V C 47...63 Hz 1 @ 230 V C, 2.1 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 3.8 @ 40 C 3.8 @ 40 C, 2.5 @ 60 C, 1.7 @ 70 C typ. 85 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 35 / 110 mm 0.5 kg BVTEX; CE; CS; curus; EC; UL 100...240 V C (wide-range input) 85...264 V C 47...63 Hz 1 @ 230 V C, 2.1 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 3.8 @ 40 C 3.8 @ 40 C, 2.5 @ 60 C, 1.7 @ 70 C typ. 85 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 35 / 110 mm 0.5 kg CE; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 2 (+ / -) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 0.5 / 2.5 24 / 12 24 / 12 3 for L/N/PE 2 (+ / -) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 0.5 / 2.5 24 / 12 24 / 12 Ordering data CP T SNT 90W 24V 3,8 1 1105790000 CP T SNT 90W 24V3,8CL2 1 1194410000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.32

connectpower PRO-H connectpower PRO-H CP T SNT 180W 24V 7.5 CP T SNT 360W 24V 15 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 1.4 @ 230 V C, 2.5 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 7.5 @ 40 C 7.5 @ 40 C, 5 @ 60 C, 3.3 @ 70 C typ. 88 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 54 / 110 mm 0.7 kg BVTEX; CE; CS; curus; EC; UL 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 2.5 @ 230 V C, 5 @ 115 V C 6.3 / < 25 (230 V C) 10 16, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 15 @ 40 C 15 @ 40 C, 10 @ 60 C, 6.7 @ 70 C typ. 87 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 80 / 110 mm 1.1 kg BVTEX; CE; CS; curus; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 7 (+ / - / Signal) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 0.5 / 2.5 24 / 12 24 / 12 3 for L/N/PE 7 (+ / - / Signal) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 24 / 12 18 / 12 Ordering data CP T SNT 180W 24V 7,5 1 1105810000 CP T SNT 360W 24V 15 1 1105820000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.33

connectpower PRO-H wenlok.com.mx connectpower PRO-H CP T SNT 600W 24V 25 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 5 @ 230 V C, 10 @ 115 V C 12 / < 30 (230 V C) 16 25, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 25 @ 40 C 25 @ 40 C, 20 @ 60 C, 13.3 @ 70 C typ. 89 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 125 / 165 / 125 mm 2.8 kg BVTEX; CE; CS; curus; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 7 (+ / - / Signal) 1 / 4 1 / 2.5 1 / 4 2.5 / 4 18 / 10 12 / 10 Ordering data CP T SNT 600W 24V 25 1 1105840000 ccessories The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system..34

connectpower PRO-H connectpower PRO-H CP T SNT 90W 48V 2 CP T SNT 180W 48V 4 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100...240 V C (wide-range input) 85...264 V C 47...63 Hz 1 @ 230 V C, 2.1 @ 115 V C 4 / < 20 (230 V C) 6 16, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mv SS @ 48 V DC, I Nenn 2 @ 40 C 2 @ 40 C, 1.3 @ 60 C, 0.8 @ 70 C typ. 87 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 35 / 110 mm 0.5 kg BVTEX; CE; EC; UL 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 1.4 @ 230 V C, 2.5 @ 115 V C 4 / < 25 (230 V C) 6 16, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mv SS @ 48 V DC, I Nenn 4 @ 40 C 4 @ 40 C, 2.5 @ 60 C, 1.7 @ 70 C typ. 90 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 110 / 54 / 110 mm 0.7 kg BVTEX; CE; CS; curus; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 2 (+ / -) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 0.5 / 2.5 24 / 12 24 / 12 3 for L/N/PE 7 (+ / - / Signal) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 0.5 / 2.5 24 / 12 24 / 12 Ordering data CP T SNT 90W 48V 2 1 1194420000 CP T SNT 180W 48V 4 1 1105850000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.35

connectpower PRO-H wenlok.com.mx connectpower PRO-H CP T SNT 360W 48V 7.5 CP T SNT 600W 48V 12.5 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 2.5 @ 230 V C, 5 @ 115 V C 6.3 / < 25 (230 V C) 10 16, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mv SS @ 48 V DC, I Nenn 7.5 @ 40 C 7.5 @ 40 C, 5 @ 60 C, 3.3 @ 70 C typ. 89 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 125 / 80 / 125 mm 1.1 kg BVTEX; CE; CS; curus; EC; UL 100 240 V C (auto-select) 85 132 V C, 187 264 V C 47...63 Hz 5 @ 230 V C, 10 @ 115 V C 12 / < 30 (230 V C) 16 25, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mv SS @ 48 V DC, I Nenn 12.5 @ 40 C 12.5 @ 40 C, 10 @ 60 C, 7.5 @ 70 C typ. 91 % @ 230 V C min. 20 ms @ 230 V C, min. 10 ms @ 115 V C yes, max. 5 125 / 165 / 125 mm 2.8 kg BVTEX; CE; CS; curus; EC; UL Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 7 (+ / - / Signal) 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 24 / 12 18 / 12 3 for L/N/PE 7 (+ / - / Signal) 1 / 4 1 / 2.5 1 / 4 2.5 / 4 18 / 10 12 / 10 Ordering data CP T SNT 360W 48V 7,5 1 1105860000 CP T SNT 600W 48V 12,5 1 1105870000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.36

connectpower PRO-H connectpower PRO-H CP T SNT2 180W 24V 7.5 CP T SNT2 360W 24V 15 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100 500 V C (switchable) 85 132 V C, 187 550 V C 50 / 60 Hz / < 23 @ 230 V C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 7.5 @ 40 C 7.5 @ 40 C, 5 @ 60 C, 3.3 @ 70 C typ. 88 % min. 20 ms Yes 110 / 54 / 110 mm 0.7 kg CE; EC 100 500 V C (switchable) 85 132 V C, 187 550 V C 50 / 60 Hz / < 23 @ 230 V C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 15 @ 40 C 15 @ 40 C, 6.7 @ 70 C, 10 @ 60 C typ. 88 % min. 20 ms Yes 125 / 80 / 125 mm 1.1 kg CE; EC Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 4 (++ / --) 1 / 4 2.5 / 4 1 / 4 2.5 / 4 18 / 10 12 / 10 The device is suitable for single-phase and two-phase operation. 3 for L/N/PE 4 (++ / --) 1 / 4 2.5 / 4 1 / 4 2.5 / 4 18 / 10 12 / 10 The device is suitable for single-phase and two-phase operation. Ordering data CP T SNT2 180 W 24 V 7,5 1 1194480000 CP T SNT2 360 W 24 V 15 1 1194490000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. ccessories.37

connectpower PRO-H wenlok.com.mx connectpower PRO-H CP T SNT2 600W 24V 25 L (+) N ( ) PE C 13 Data 14 DC Link + DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 100 500 V C (switchable) 85 132 V C, 187 550 V C 50 / 60 Hz / < 50 @ 230 V C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 25 @ 40 C 25 @ 40 C, 20 @ 40 C, 13.3 @ 70 C typ. 88 % min. 20 ms Yes 125 / 190 / 125 mm 3 kg CE; EC Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 3 for L/N/PE 5 (++ / ---) 1 / 4 2.5 / 4 1 / 4 2.5 / 4 18 / 10 12 / 10 The device is suitable for single-phase and two-phase operation. Ordering data CP T SNT2 600 W 24 V 25 1 1194310000 ccessories The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system..38

connectpower PRO-H connectpower PRO-H CP T RM 10 CP T RM 20 1 Data Link PS1 Data Link PS2 1 Data Link PS1 Data Link PS2 Control Control 2 Remote ON/OFF DC OK 2 Remote ON/OFF DC OK Rated input voltage voltage range C Frequency range C C current consumption fuse (internal) / Inrush current Recommended back-up fuse Rated output voltage voltage Residual ripple, breaking spikes Rated (nominal) output current @ U Nom continous output current @ 24 V DC General data Degree of efficiency C failure bridging time @ I Nom Parallel connection option Depth x width x height Weight 24 V DC 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 15 @ 40 C 110 / 35 / 110 mm 0.4 kg CE; CS; curus; EC; GOSTME25 24 V DC 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mv PP @ 24 V DC, I nenn 25 @ 40 C 110 / 54 / 110 mm 0.45 kg CE; CS; curus; EC; GOSTME25 Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 4 (++--) 4 (++ / --) 1 / 4 2.5 / 4 1 / 4 2.5 / 4 18 / 10 12 / 10 4 (++--) 4 (++ / --) 1 / 4 2.5 / 4 1 / 4 2.5 / 4 18 / 10 12 / 10 Ordering data CP T RM 10 1 1105880000 CP T RM 20 1 1105890000 ccessories.39

connectpower PRO H - ccessories Small screwdriver Type Blade type Size/F a b c Order No. SDIK PH1 1.00 80 9008570000 SDIS 0.5X3.0X100 B 0.5 3 100 9008380000 Large screwdriver Type Blade type Size/F a b c Order No. SDIK PH2 2.00 100 9008580000 SDIS 1.0X5.5X125 B 1 5.5 125 9008410000 Markers End bracket For DIN rail TS 35 Type Colour Qty. Order No. SM 18/9.5 K MC NE WS white 200 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Order No. WEW 35/1 SW black 1.2 Nm 50 1162600000.40

connectpower PRO-H (4.33) 35.0 (1.38) - - + + s ON 24 27 V 38.5 (1.52) 110.0 (4.33) (4.33) 54.0 (2.13) DC 24 V / 25 s ON 24 27 V 38.5 (1.52) 110.0 (4.33) 110.0 DC IN 1 DC IN 2 - + - + 80.0 (3.15) 110.0 DC IN 1 DC IN 2 80.0 (3.15) 5.0 (0.20) 25.0 (0.98) 5.0 (0.20) 5.0 (0.20) 25.0 (0.98) 14.5 (0.57) 54.0 (2.13) 110.0 (4.33) DC ON O/P DJ. DC OK (4.33) S P wenlok.com.mx PRO-H Dimensional drawings CP T RM 10 CP T RM 20 CP T SNT 70 W / 90 W CP T SNT 180 W / 140 W 35.0 (1.38) 110.0 (4.33) DC OK DC ON O/P DJ. 38.5 (1.52) 38.5 (1.52) 110.0 (4.33) PE N L 80.0 (3.15) 110.0 PE N L 80.0 (3.15) 5.0 (0.20) 25.0 (0.98) 5.0 (0.20) 5.0 (0.20) 25.0 (0.98) 14.5 (0.57) P/ S P S Remote P/ S Remote.41

connectpower PRO-H wenlok.com.mx PRO-H Dimensional drawings CP T SNT 360 W / 480 W (4.92) 125.0 PE N 80.0 (3.15) DC OK DC ON O/P DJ. L 45.0(1.77) 86.5(3.41) 125.0 (4.92) CP T SNT 600 W / 960 W 25.0 (0.98) P/ S P S Remote 123.0 (4.84) 25.0 (0.98) 21.0 (0.83) 165.0 (6.50) 125.0 (4.92) 5.0 (0.20) 25.0 (0.98) 46.0 17.0 (1.81) (0.67) 25.0 (0.98) (4.92) 45.0 (1.77) 125.0 PE N L DC OK DC ON O/P DJ. 86.5 (3.41) Remote P S P/ S.42

.43

connectpower PRO-E connectpower PRO-E CP E SNT 25W 5V 5 CP E SNT 25W 12V 2.1 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 0.3 @ 230 V C / 0.6 @ 120 V C 47...63 Hz yes / max. 20 1 at 230 V C, characteristic curve C 5 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 5 @5 V DC 25 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 5.6...6.8 V @ 5 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 77 % @ 5 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 240 g CE; curus; EC 0.34 / 4 91 / 51 / 28 mm 85...264 V C / 110 370 V DC 0.3 @ 230 V C / 0.6 @ 120 V C 47...63 Hz yes / max. 20 1 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 2.1 @12 V DC 25 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 79 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 240 g CE; curus; EC 0.34 / 4 91 / 51 / 28 mm Ordering data CP E SNT 25W 5V 5 1 1202640000 CP E SNT 25W 12V 2.1 1 1202630000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..44

connectpower PRO-E connectpower PRO-E CP E SNT 25W 24V 1.1 CP E SNT 25W 48V 0.57 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 0.3 @ 230 V C / 0.6 @ 120 V C 47...63 Hz yes / max. 20 1 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 1.1 @24 V DC 25 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 84 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 240 g CE; curus; EC 0.34 / 4 91 / 51 / 28 mm 85...264 V C / 110 370 V DC 0.3 @ 230 V C / 0.6 @ 120 V C 47...63 Hz yes / max. 20 1 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 0.57 @48 V DC 25 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 83 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 240 g CE; curus; EC 0.34 / 4 91 / 51 / 28 mm Ordering data CP E SNT 25W 24V 1.1 1 1202620000 CP E SNT 25W 48V 0.57 1 1202610000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..45

connectpower PRO-E connectpower PRO-E CP E SNT 50W 5V 10 CP E SNT 50 W 12V 4.2 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 0.6 @ 230 V C / 1.2 @ 120 V C 47...63 Hz yes / max. 20 2 at 230 V C, characteristic curve C 5 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 10 @5 V DC 50 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 5.6...6.8 V @ 5 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 78 % @ 5 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 310 g CE; curus; EC 0.34 / 4 105 / 100 / 35 mm 85...264 V C / 110 370 V DC 0.6 @ 230 V C / 1.2 @ 120 V C 47...63 Hz yes / max. 20 2 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 4.2 @12 V DC 50 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 81 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 310 g CE; curus; EC 0.34 / 4 105 / 100 / 35 mm Ordering data CP E SNT 50W 5V 10 1 1202590000 CP E SNT 50W 12V 4.2 1 1202580000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..46

connectpower PRO-E connectpower PRO-E CP E SNT 50W 24V 2.2 CP E SNT 50W 48V 1.1 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 0.6 @ 230 V C / 1.2 @ 120 V C 47...63 Hz yes / max. 20 2 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 2.2 @24 V DC 50 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 84 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 310 g CE; curus; EC 0.34 / 4 105 / 100 / 35 mm 85...264 V C / 110 370 V DC 0.6 @ 230 V C / 1.2 @ 120 V C 47...63 Hz yes / max. 20 2 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 1.1 @48 V DC 50 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 86 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 310 g CE; curus; EC 0.34 / 4 105 / 100 / 35 mm Ordering data CP E SNT 50W 24V 2.2 1 1202450000 CP E SNT 50W 48V 1.1 1 1202460000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..47

connectpower PRO-E connectpower PRO-E CP E SNT 75W 5V 12 CP E SNT 75W 12V 6 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 1 @ 230 V C / 2 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 5 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 12 @5 V DC 75 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 5.6...6.8 V @ 5 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 76 % @ 5 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 440 g CE; curus; EC 0.34 / 4 135 / 98.5 / 40 mm 85...264 V C / 110 370 V DC 1 @ 230 V C / 2 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 6 @12 V DC 75 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 81 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 440 g CE; curus; EC 0.34 / 4 135 / 98.5 / 40 mm Ordering data CP E SNT 75W 5V 12 1 1202470000 CP E SNT 75W 12V 6 1 1202480000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..48

connectpower PRO-E connectpower PRO-E CP E SNT 75W 24V 3.2 CP E SNT 75W 48V 1.6 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 1 @ 230 V C / 2 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 3.2 @24 V DC 75 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 85 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 440 g CE; curus; EC 0.34 / 4 135 / 98.5 / 40 mm 85...264 V C / 110 370 V DC 1 @ 230 V C / 2 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 1.6 @48 V DC 75 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 86 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 440 g CE; curus; EC 0.34 / 4 135 / 98.5 / 40 mm Ordering data CP E SNT 75W 24V 3.2 1 1202490000 CP E SNT 75W 48V 1.6 1 1202510000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..49

connectpower PRO-E connectpower PRO-E CP E SNT 100W 5V 16 CP E SNT 100W 12V 8.5 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 1.5 @ 230 V C / 3 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 5 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 16 @5 V DC 100 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 5.6...6.8 V @ 5 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 77 % @ 5 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 590 g CE; curus; EC 0.34 / 4 164 / 97.5 / 40 mm 88 132 V C / 176 264 V C optional / 250...370 V DC 1.5 @ 230 V C / 3 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 8.5 @12 V DC 100 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 81 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 590 g CE; curus; EC 0.34 / 4 164 / 97.5 / 40 mm Ordering data CP E SNT 100W 5V 16 1 1165820000 CP E SNT 100W 12V 8.5 1 1165830000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..50

connectpower PRO-E connectpower PRO-E CP E SNT 100W 24V 4.5 CP E SNT 100W 48V 2.3 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 1.5 @ 230 V C / 3 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 4.5 @24 V DC 100 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 85 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 590 g CE; curus; EC 0.34 / 4 164 / 97.5 / 40 mm 88 132 V C / 176 264 V C optional / 250...370 V DC 1.5 @ 230 V C / 3 @ 120 V C 47...63 Hz yes / max. 20 4 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 2.3 @48 V DC 100 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 86 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 590 g CE; curus; EC 0.34 / 4 164 / 97.5 / 40 mm Ordering data CP E SNT 100W 24V 4.5 1 1165840000 CP E SNT 100W 48V 2.3 1 1165850000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..51

connectpower PRO-E connectpower PRO-E CP E SNT 150W 12V 12.5 CP E SNT 150W 24V 6.5 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 2 @ 230 V C / 3.5 @ 120 V C 47...63 Hz yes / max. 35 4 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 12.5 @12 V DC 150 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 82 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 820 g CE; curus; EC 0.34 / 4 205 / 99 / 40 mm 88 132 V C / 176 264 V C optional / 250...370 V DC 2 @ 230 V C / 3.5 @ 120 V C 47...63 Hz yes / max. 35 4 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 6.5 @24 V DC 150 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 86 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 820 g CE; curus; EC 0.34 / 4 205 / 99 / 40 mm Ordering data CP E SNT 150W 12V 12.5 1 1165870000 CP E SNT 150W 24V 6.5 1 1165880000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..52

connectpower PRO-E connectpower PRO-E CP E SNT 150W 48V 3.3 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 2 @ 230 V C / 3.5 @ 120 V C 47...63 Hz yes / max. 35 4 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 3.3 @48 V DC 150 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 87 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 820 g CE; curus; EC 0.34 / 4 205 / 99 / 40 mm Ordering data CP E SNT 150W 48V 3.3 1 1165890000 The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. ccessories.53

connectpower PRO-E connectpower PRO-E CP E SNT 250W 12V 21 CP E SNT 250W 24V 10.5 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 2.5 @ 230 V C / 4.7 @ 120 V C 47...63 Hz yes / max. 35 6 at 230 V C, characteristic curve C 12 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 21 @12 V DC 250 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 13.5...16.2 V @ 12 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 80 % @ 12 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 1080 g CE; curus; EC 0.34 / 4 231 / 115 / 49.5 mm 88 132 V C / 176 264 V C optional / 250...370 V DC 2.5 @ 230 V C / 4.7 @ 120 V C 47...63 Hz yes / max. 35 6 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 10.5 @ 24 V DC 250 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 81 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 1080 g CE; curus; EC 0.34 / 4 231 / 115 / 49.5 mm Ordering data CP E SNT 250W 12V 21 1 1202520000 CP E SNT 250W 24V 10.5 1 1202530000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..54

connectpower PRO-E connectpower PRO-E CP E SNT 250W 48V 5.2 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 88 132 V C / 176 264 V C optional / 250...370 V DC 2.5 @ 230 V C / 4.7 @ 120 V C 47...63 Hz yes / max. 35 6 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 5.2 @48 V DC 250 W < 100 mv PP 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 83 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 1080 g CE; curus; EC 0.34 / 4 231 / 115 / 49.5 mm Ordering data CP E SNT 250W 48V 5.2 1 1202540000 The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. ccessories.55

connectpower PRO-E connectpower PRO-E CP E SNT 350W 24V 14.6 CP E SNT 350W 48V 7.3 voltage current frequency fuse (internal) Recommended back-up fuse voltage voltage adjustment current power Residual ripple, breaking spikes Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output General data mbient temperature (operational) Storage temperature Max. perm. air humidity (operational) Degree of efficiency Status indicator Standards EMC standards Mounting position, installation notice Weight Connection cross-section, solid, min. / max. Depth x width x height 85...264 V C / 110 370 V DC 3 @ 230 V C / 5.6 @ 120 V C 47...63 Hz yes / max. 35 6 at 230 V C, characteristic curve C 24 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 14.6 @24 V DC 350 W 120~150% Ikonst. of max. output power, automatic restart 28...32 V @ 24 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 83 % @ 24 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 1250 g CE; curus; EC 0.34 / 4 230 / 115 / 49.5 mm 85...264 V C / 110 370 V DC 3 @ 230 V C / 5.6 @ 120 V C 47...63 Hz yes / max. 35 6 at 230 V C, characteristic curve C 48 V DC ± 10% nominal output voltage tolerance, adjustable with potentiometer 7.3 @48 V DC 350 W 120~150% Ikonst. of max. output power, automatic restart 55...62 V @ 48 V DC 20 ms 0.5% Recommended with diode module 0.5 kv 1.5 kv 3 kv -20 C 70 C (>50 C derating,refer derated curve); 70% rated load@70 C -20 C...85 C 5 % 95 % RH 85 % @ 48 V DC Operation, green LED EN 60950 EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3 Panel mount, screw fix 1250 g CE; curus; EC 0.34 / 4 230 / 115 / 49.5 mm Ordering data CP E SNT 350W 24V 14.6 1 1202550000 CP E SNT 350W 48V 7.3 1 1202560000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..56

.57

connectpower PRO-E wenlok.com.mx Installation drawing CP E SNT 25W 78 55 11 25.5 CP E SNT 50W Ø 3.5 6.5 105 99.5 52.5 34 2-M3 32 93 100 66 3 Ø 4 2-M3 Ø 3.5 3.25 Ø 3.5 3.25 2-M3 14 28 30 93 100 12 12 15 13.5 35 15 3-M3 CP E SNT 75W CP E SNT 100W 6.5 135 124.5 52 4.4 Ø 3.5 Ø 3.5 34 32 91.5 98.5 2-M3 Ø 3.5 Ø 3.5 2.75 124.5 78 22 2.25 Ø 3.5 31 19.8 3-M3 18 29.5 40 11 205 195.5 120 18.5 6.5 6 164 78 57 32 32.5 90.5 97.5 Ø 3.5 4-M3 3-M3 9.25 Ø 3.5 3.25 2.25 Ø 3.5 28.4 18.6 117 20 152.5 18 28.5 40 10 CP E SNT 150W 28 Ø 3.5 18 4-M3 157 157 193 205 Ø 3.5 4.75 Ø 3.5 3.5 20.5 11 18.5 80.5 31 92 40 99 3-M3.58

5-M3 20 150 32.5 25 12.5 49.5 230 5-M3 Ø4.5 wenlok.com.mx connectpower PRO-E Installation drawing CP E SNT 250W and CP E SNT 350W CP E SNT 250W and CP E SNT 350W (with mounting clip) 115 57 50 115 15 8 32.5 26 14 150 26 8 15 3-Ø4.5 230 150 150.5 32.5 32.5 26 Ø4.5 150 6-M3 32 118 32.5 12.5 25 145 131 115 230 14 26 Ø4.5 49.5 26 Ø4.5 32.5 26 150 26 3-Ø4.514 115 131 145 15 8 Ø4.5 49.5 8 68 15 3-Ø4.5 230 25 14 26 CP-E-SNT derating curve / ambient temperature CP E SNT 25W up to CP E SNT 350W 100% 80% Load (%) 60% 40% 20% 0 10 20 30 40 50 60 70 80 mbient temperature ( C).59

connectpower INSTPOWER wenlok.com.mx connectpower Single-phase CP SNT 24W 24V 1 CP SNT 24W 15V 1.5 L C/DC N PWM + DC L N FUSE + L N FUSE + voltage current frequency Turn-on current limit fuse Surge protection voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...265 V C, 120...300 V DC 460 m @ 115 V C; 250 m @ 230 V C 50/ 60 Hz Thermistor 2 time-lag fuse (internal) Varistor 24 V DC 1 24 W < 2 % Surge current / thermal cut-out Varistor 35 ms @ 115 V C / 160 ms @ 230 V C 0.5% 8000 µf 0.5 kv 1.5 kv 3 kv 4 kv -20 C...50 C -40 C...85 C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CS; CSEX; culus; EC; GOSTME25 EN 61000-6 /-2, -3 yes, max 2. 85...265 V C, 120...300 V DC 460 m @ 115 V C; 250 m @ 230 V C 50/ 60 Hz Thermistor 2 time-lag fuse (internal) Varistor 15 V DC 1.5 22.5 W < 2 % Surge current / thermal cut-out Varistor 35 ms @ 115 V C / 160 ms @ 230 V C 0.5% 8000 µf 0.5 kv 1.5 kv 3 kv 4 kv -20 C...50 C -40 C...85 C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CS; culus; EC; GOSTME25 EN 61000-6 /-2, -3 yes, max 2. Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. / 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data CP SNT 24W 24V 1 1 9928890024 CP SNT 24W 15V 1.5 1 9928890015 The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. ccessories.60

connectpower INSTPOWER connectpower Single-phase CP SNT 24W 12V 1.5 CP SNT 24W 5V 2 L C/DC N PWM + DC L N FUSE + L N FUSE + voltage current frequency Turn-on current limit fuse Surge protection voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...265 V C, 120...300 V DC 460 m @ 115 V C; 250 m @ 230 V C 50/ 60 Hz Thermistor 2 time-lag fuse (internal) Varistor 12 V DC 1.5 18 W < 2 % Surge current / thermal cut-out Varistor 35 ms @ 115 V C / 160 ms @ 230 V C 0.5% 8000 µf 0.5 kv 1.5 kv 3 kv 4 kv -20 C...50 C -40 C...85 C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CS; culus; EC; GOSTME25 EN 61000-6 /-2, -3 yes, max 2. 85...265 V C, 120...300 V DC 460 m @ 115 V C; 250 m @ 230 V C 50/ 60 Hz Thermistor 2 time-lag fuse (internal) Varistor 5 V DC 2 10 W < 2 % Surge current / thermal cut-out Varistor 35 ms @ 115 V C / 160 ms @ 230 V C 0.5% 8000 µf 0.5 kv 1.5 kv 3 kv 4 kv -20 C...50 C -40 C...85 C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CS; culus; EC; GOSTME25 EN 61000-6 /-2, -3 yes, max 2. Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. / 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data CP SNT 24W 12V 1.5 1 9928890012 CP SNT 24W 5V 2 1 9928890005 The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system. ccessories.61

connectpower INSTPOWER wenlok.com.mx connectpower Single-phase CP SNT 25W 5V 5 L C/DC N PWM + DC L N FUSE + voltage current frequency Turn-on current limit fuse voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...264 V C / 110...370 V DC 500 m at rated load @ 230 V C 50/ 60 Hz Yes Fusible link 2.5 (T) / 250 V 4...8 V DC (adjustable via potentiometer) 5 25 W 120 mv SS 105 %...150 % I const of max. output load; automatic reset Varistor 11 ms @ 115 V C / 50 ms @ 230 V C 1% 10000 µf 0.5 kv 1.5 kv 3 kv 4 kv -10...70 C (Derating ab 55 C) -20 C...85 C 70% DIN EN 50178 (PELV), DIN EN 60950 (SELV) ccsus; curus; EC; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 Max. 3 devices (rated voltages are to be calibrated at ±20 mv) Derating curve Current () 6 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 mbient temperature ( C) Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 2.5 / 0.5 / 4 62.5 / 70 / 90.5 Ordering data CP SNT 25W 5V 5 1 8754960000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..62

connectpower INSTPOWER connectpower Single-phase CP SNT 48W 12V 4 L C/DC N PWM + DC L N FUSE + voltage current frequency Turn-on current limit fuse voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...264 V C / 110...370 V DC 500 m at rated load @ 230 V C 50/ 60 Hz Yes Fusible link 2.5 (T) / 250 V 9...15 V DC (adjustable via potentiometer) 4 48 W 120 mv SS 105 %...150 % I const of max. output load; automatic reset Varistor 11 ms @ 115 V C / 50 ms @ 230 V C 1% 10000 µf 0.5 kv 1.5 kv 3 kv 4 kv -10...70 C (Derating ab 55 C) -20 C...85 C 75% DIN EN 50178 (PELV), DIN EN 60950 (SELV) ccsus; CE; curus; EC; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 Max. 3 devices (rated voltages are to be calibrated at ±20 mv) Derating curve Current () 6 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 mbient temperature ( C) Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 2.5 / 0.5 / 4 62.5 / 70 / 90.5 Ordering data CP SNT 48W 12V 4 1 8754970000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..63

connectpower INSTPOWER wenlok.com.mx connectpower Single-phase CP SNT 48W 24V 2 L C/DC N PWM + DC L N FUSE + voltage current frequency Turn-on current limit fuse voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...264 V C / 110...370 V DC 500 m at rated load @ 230 V C 50/ 60 Hz Yes Fusible link 2.5 (T) / 250 V 15...28 V DC (adjustable via potentiometer) 2 48 W 120 mv SS 105 %...150 % I const of max. output load; automatic reset Varistor 11 ms @ 115 V C / 50 ms @ 230 V C 1% 10000 µf 0.5 kv 1.5 kv 3 kv 4 kv -10...70 C (Derating ab 55 C) -20 C...85 C 78% DIN EN 50178 (PELV), DIN EN 60950 (SELV) ccsus; curus; EC; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 Max. 3 devices (rated voltages are to be calibrated at ±20 mv) Derating curve Current () 3 2.5 2 1.5 1 0.5 0 0 10 20 30 40 50 60 70 80 mbient temperature ( C) Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 2.5 / 0.5 / 4 62.5 / 70 / 90.5 Ordering data CP SNT 48W 24V 2 1 8739140000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..64

connectpower INSTPOWER connectpower Single-phase CP SNT 48W 48V 1 L C/DC N PWM + DC L N FUSE + voltage current frequency Turn-on current limit fuse voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Standards EMC standards Parallel connection option 85...264 V C / 110...370 V DC 500 m at rated load @ 230 V C 50/ 60 Hz Yes Fusible link 2.5 (T) / 250 V 46...55 V DC (adjustable via potentiometer) 1 48 W 120 mv SS 105 %...150 % I const of max. output load; automatic reset Varistor 11 ms @ 115 V C / 50 ms @ 230 V C 1% 10000 µf 0.5 kv 1.5 kv 3 kv 4 kv -10...70 C (Derating ab 55 C) -20 C...85 C 80% DIN EN 50178 (PELV), DIN EN 60950 (SELV) ccsus; curus; EC; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 Max. 3 devices (rated voltages are to be calibrated at ±20 mv) Derating curve Current () 2 1.5 1 0.5 0 0 10 20 30 40 50 60 70 80 mbient temperature ( C) Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 2.5 / 0.5 / 4 62.5 / 70 / 90.5 Ordering data CP SNT 48W 48V 1 1 8879230000 ccessories The internal varistor found in a switch-mode power supply does not replace the necessary surge protection in a system..65

connectpower INSTPOWER - ccessories Small screwdriver Type Blade type Size/F a b c Order No. SDIK PH1 1.00 80 9008570000 SDIS 0.5X3.0X100 B 0.5 3 100 9008380000 Markers End bracket For DIN rail TS 35 Type Colour Qty. Order No. SM 18/9.5 K MC NE WS white 200 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Order No. WEW 35/1 SW black 1.2 Nm 50 1162600000.66

connectpower WVEPOWER connectpower Single-phase CP SNT 12W 24V 0.5 L C/DC N PWM + DC voltage current frequency fuse Surge protection voltage current power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data mbient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction 85...265 V C, 120...300 V DC 260 m @ 115 V C; 180 m @ 230 V C 50/ 60 Hz 2 time-lag fuse (internal) Varistor 24 V DC 0.5 12 W 0.1 % Surge current / thermal cut-out Varistor 30 ms @ 115 V C / 80 ms @ 230 V C 0.6% No 0.5 kv 1.5 kv 3 kv 4 kv -20...50 C -40 C...85 C 80% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CS; culus; EC; GOSTME25 Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 2.5 / 0.5 / 2.5 112.4 / 22.5 / 92.4 Ordering data CP SNT 12W 24V 0.5 1 9918840024 ccessories The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Supply voltage 24 V and 0 V can be cross-connected with ZQV 2.5N/2.67

connectpower DC/DC converter wenlok.com.mx connectpower CP DCDC 50W 22-24V 2 CP DCDC 50W 20-24V 2 Chopper Transformer Rectifier and filtering Chopper Transformer Rectifier and filtering voltage fuse voltage current Overload protection General data mbient temperature (operational) Storage temperature Status indication Switching frequency 18...30 V DC, typ. 24 V DC, ± 15% internal 22...24 V DC 2 Surge current cut-out with self-reset -10...60 C (Derating ab 50 C) -40 C...85 C Green LED 200 khz CE; CS; CSEX; culus; EC 10 14 V DC, typ. 12V DC, ± 15% internal 20.5...29.5 V DC 2 Surge current cut-out with self-reset -10...60 C (Derating ab 50 C) -40 C...85 C Green LED 200 khz CE; CS; CSEX; culus; EC Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 4 / 0.1 / 4 131 / 57 / 98 / 4 / 0.1 / 4 131 / 57 / 98 Ordering data CP DCDC 50W 22-24V 2 1 9919372424 CP DCDC 50W 22-24V 2 1 9919371224 ccessories Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000.68

connectpower DC/DC converter CP DCDC 50W 12V 3 Chopper Transformer Rectifier and filtering 18...30 V DC, typ. 24 V DC, ± 15% internal 10.5...14.5 V DC 3 Surge current cut-out with self-reset -10...60 C (Derating ab 50 C) -40 C...85 C Green LED 200 khz CE; CS; CSEX; culus; EC / 4 / 0.1 / 4 131 / 57 / 98 CP DCDC 50W 12V 3 1 9919372412 Bracket for wall mounting: 7920560000.69

connectpower DC/DC converter wenlok.com.mx connectpower CP DCDC 50W 15V 3 CP DCDC 50W 5V 8 Chopper Transformer Rectifier and filtering Chopper Transformer Rectifier and filtering voltage fuse voltage current Overload protection General data mbient temperature (operational) Storage temperature Status indication Switching frequency 18...30 V DC, typ. 24 V DC, ± 15% internal 15 V DC 3 Surge current cut-out with self-reset -10...60 C (Derating ab 50 C) -40 C...85 C Green LED 200 khz CE; CS; CSEX; culus; EC 18...30 V DC, typ. 24 V DC, ± 15% internal 5 V DC 8 Surge current cut-out with self-reset -10...60 C (Derating ab 50 C) -40 C...85 C Green LED 200 khz CE; CS; CSEX; culus; EC Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm / 4 / 0.1 / 4 131 / 57 / 98 / 4 / 0.1 / 4 131 / 57 / 98 Ordering data CP DCDC 50W 15V 3 1 9919372415 CP DCDC 50W 5V 8 1 9919372405 ccessories Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000.70

.71

connectpower DC/DC converter wenlok.com.mx connectpower DC/DC converter DC voltage converter for preparation and potential isolation in 24 V DC systems Overvoltage category III Class III protection Status of relay contact DC OK transistor output % { \ u Pout [% Pn] Temperature derating 130 120 110 100 90 80 70 60 20 30 40 50 60 70 80 mbient temperature [ C] General technical specifications characteristic curve / current limit IU / > 120 % I R Earth discharge current < 0.005 m mbient temp. Operating / storage temperature 25 C +70 C / 40 C +85 C Max. permitted humidity (operational) 5 % 95 % RH Protection degree IP 20 Class of protection III Contamination degree 2 Insulation voltage 2.5 kv C 1 min. / 1.5 kv C 1 min. / 0.5 kv C 1 min. Overvoltage category III MTBF > 500,000 hrs. according to IEC 1709 (SN29500) Protection against load reverse voltages 33 34 V DC Parallel capability (without diode module) Yes, max. 5 Mountable side-by-side without gaps Yes Housing version, metal Resistant to corrosion Signal operations LED green / red Mounting position, installation notice Horizontal on TS 35 DIN rail, above and below 50 mm Clearance for air circulation, suitable for aligning without clearance gap For installation in rotating systems Metal clip-on foot Yes EMC / shock / vibration Noise emission according to EN55022 Class B Interference immunity tests, according to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) Limiting of mains voltage harmonic currents ccording to EN 61000-3-2 Resistance against vibration and shock ccording to EN50178, shock: 5 g in all directions Electrical safety (applied standards) Electrical equipment of machines ccording to EN60204 Safety transformers for switched-mode power units ccording to EN61558-2-17 Machinery with electronic equipment ccording to EN50178 / VDE0160 Safety extra-low voltage SELV according to EN60950, PLEV according to EN60204 Protective separation / protection against electrical shock VDE0100-410 / according to DIN57100-410 Protection against dangerous shock currents ccording to VDE0106-101 ccessories Diode module (for redundant power supply) CP M DM 20 1 1222210000 Capacity module (for pulse triggering of circuit breakers) CP M CP 1 1222240000.72

connectpower DC/DC converter connectpower DC/DC converter CP DCDC 250W 24V 10 + DC DC + DC OK 14 13 Rated input voltage / DC input voltage range DC current consumption Inrush current fuse (internal) Recommended back-up fuse Rated output voltage voltage Ramp-up time Residual ripple, breaking spikes Rated (nominal) output current @ U Nom Short-circuit protection / Overload protection Powerboost @ 24 V DC, 60 C General data Degree of efficiency Power loss C failure bridging time @ I Nom Tightening torque Reverse polarity protection Depth x width x height / Weight Signalling Status indicator DC OK transistor output 1 (max. load) DC OK transistor output 0 / DC OK short circuit resistant Floating contact Contact load Relay on/off Connection data Wire connection method Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max 24 V DC / 18... 31.2 V DC Typ.: 11, Max.: 15.5 Max. 10 Yes 16 / DI/II safety fuse, 16, Char. B circuit breaker, 16, Char. C circuit breaker 24 V DC ± 1 % 100 ms < 50 mv SS @ 24 V DC, I N 10 @ 60 C Yes / Yes 12 for 1 min, ED = 5 % typ. 91% Idle: max. 2 W, Nominal load: 24 W > 7 ms @ 24 V DC 0.5...0.6 Nm Yes 150 / 60 / 130 mm / 1250 g LED green (DC OK): output voltage 21.6 V, LED red (fault): output voltage 20.4 V voltage 21.6 V ( max. 250 m) voltage 20.4 V / Yes Yes max. 30 V DC / 0.5 voltage > 21.6 V / < 20.4 V culus; EC; GL; TUEV 2 for (+ -) 7 for (DCOK, 13,14, + + --) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 Ordering data CP DCDC 250W 24V 10 1 1313320010 ccessories.73

.74

Contents Uninterruptible power supplies (UPS) Uninterruptible power supplies (UPS) Uninterruptible power supplies (UPS) Overview B.2 UPS control unit B.4 Battery modules B.6 B Buffer modules B.8 B.1

Uninterruptible power supplies (UPS) Overview wenlok.com.mx Uninterruptible power supplies (UPS) B Uninterruptible power supplies Weidmüller s uninterruptible power supplies reliably protect 24 V DC consumers from voltage drop-outs and dips, such as those that could occur as a result of mains faults. These products therefore play a key role in increasing systems availability. The buffer module is the perfect solution for bridging short-term power supply failures or dips of up to 100 ms. The capacitor-based technology enables maintenance-free operation, depending on the application, of up to 10 years. The UPS control unit, together with the accompanying battery module and the power supply, form a complete DC UPS system with support times in minutes or hours. The modular construction allows for the overall load to be distributed into non-safe and safe load circuits, such that often a smaller UPS can be designed. huge variety of operating types are available to suit the particular application precisely. remote input to block battery operation, as well as multiple signal outputs, enable remote operation of the UPS. UPS with battery module UPS with buffer module Mains PRO-M C DC Relay and transistor ouput CP DC BUFFER 24V 20 + Buffer module Safe load + +24 V DC +24 V DC Non-safe load B.2

Uninterruptible power supplies (UPS) Overview Can your facility afford to experience a power failure? llow us to connect you so that you are safe from failure and downtime. Let s connect. Uninterruptible power supplies (UPS) B It is critical to safeguard a facility s power supply in the event of an outage. You cannot do without the important signals from the field, which serve to control the entire process. In addition, you also need to monitor a whole range of functions and performance parameters for your facility. Our highly modular power supply concept will support you in the practical fulfilment of all your requirements. t the same time, we will also familiarise ourselves with your future requirements and provide you with an individual, tailor-made solution, with components that are precisely aligned to work with one another. For a continual, lasting power supply and clean control voltage, we use redundant circuits, selective short-circuit solutions, battery reservoirs and DC/DC converters. nd because lightning and power surges can put an uninterrupted power supply in a production facility at risk, we also provide lightning and overvoltage protection. The VPU series provides unrestricted operation of power supplies and automation devices such as sensors, actuators and control units. The subsequent availability of the power supply means that all devices will restart in a controlled manner. Let s connect. PRO-M Used to save space in automation technology Individual modulation of the output power Up to 5 devices can be switched directly, in parallel Optional diode modules with fault signalling Expanded temperature range 25 C to 70 C UPS control unit Different status relays for status monitoring Direct switchover to battery operation in the event of malfunction utomatic reconnection to load when power recovers Long battery life due to integrated deep discharge protection Optimised charging feature B.3

UPS control unit wenlok.com.mx Uninterruptible power supplies (UPS) Two 24 V models in 10 /20 and 40 Temperature-compensated charging feature for long battery life Integrated battery diagnostics including continuous availability test Status relay and additional transistor outputs for remote monitoring Convenient LED displays for easy error analysis B % { \ u Indication Status relay ( max.load 30 V C/DC 0.1 ) Transistor outputs (24 to 27 V DC max. load 150 m) LED status indicator Fault (alarm), battery operation (buff.), charging (charg.) Fault (alarm), battery operation (buff.), charging (charg.) Three-colour LED: battery capacities > 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing) Green/yellow LED: normal / buffering Yellow/red LED: temperature alarm / alarm Yellow/red LED: switch-off / battery fault General technical data mbient temperature (operational) 25 C +70 C Storage temperature 40 C +85 C Max. perm. air humidity 5 95 % Protection degree IP 20 Class of protection 3 Pollution severity level 2 Overvoltage category III Insulation voltage input/output to housing/ground 1300 V DC 1 min (typetest) MTBF > 500,000 hours acc. to IEC 1709 Protection against reverse voltages from the load 32 34 V DC Parallel connection option Yes, only with diode module for redundancy Housing version Metal, corrosion resistant Mounting position, installation notice Horizontal on mounting rail TS 35, 50 mm above and below Space for free movement of air Overload protection Yes Short-circuit protection Yes EMC / shock / vibration Interference emission cc. to EN55022 Class B Interference immunity tests cc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields), EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted), EN61000-4-11 (dips) Resistance against vibration and shock cc.to IEC60954 Vibration: 2.3 g, cc.to IEC60068-2-31 shock: 30 g in all directions Electrical safety (applied standards) Electrical equipment of machines cc. to EN60204 Safety transformers for switch-mode power supplies cc. to EN61558-2-17 Machinery with electronic equipment cc. to EN50178 / VDE0160 Extra-low voltage protection SELV acc. to EN60950, PLEV acc. to EN60204 Block diagram Cabling Interlock 1 Interlock + 2 Temperature 6 Sensor 7 Selector switches Buffer time Battery size DIP switch 10/20 (only1370050010) + 24V DC Battery Capacity Normal / Buffering larm Cut-off / Bat.Failure Bat + + µc Charger 3 larm 4 Buffering 5 Charging 11 14 larm 12 21 24 Buffering 22 31 34 Charging 32 + 24V DC Unbuffered DC Load + Buffered DC Load + + + + + + + 24V DC Battery Power Supply DC UPS Battery Module PRO M Series CP DC UPS 24V DC 20/10 CP BTTERY 24V DC.. h CP DC UPS 24V DC 40 1 2 3 4 5 11 21 31 6 7 12 14 22 24 32 34 7 6 Temperature Sensor B.4

UPS control unit UPS control unit CP DC UPS 24V 20/10 CP DC UPS 24V 40 Uninterruptible power supplies (UPS) Rated input voltage DC input voltage range current fuse (internal) DC current consumption Reverse polarity protection Rated output voltage voltage Rated (nominal) output current @ U Nom continous output current @ 24 V DC Powerboost @ 24 V DC, 60 C Integrated battery charger Charging feature Charging voltage (temperature compensated) Temperature coefficient Charging current Battery availability test Battery module Rated voltage Storage medium Parallel connection option [battery] Operating elements and control inputs current selector switch Selector switch battery Selector switch buffer times DIP switch Remote disconnection (Interlock) Temperature probe General data Buffer times Degree of efficiency Power loss Depth x width x height / Weight 24 V DC 20...30 V DC 13 (for 10), 23 (for 20) Yes max. 200 m (without battery), max. 0.5 (with fully charged battery) Yes 24 V DC ± 1 % Vo = Vin - 0.2 V normal operation (Imax), Vo = Vin - 0.3 V battery operation (Imax) 20 @ 60 C 24 @ 45 C, 20 @ 60 C, 15 @ 70 C 24 for 1 min, ED = 5 % IU characteristic curve 27, 48 V @ 20 C - 48 mv / C 0.15 C every minute 24 V 1.3 h, 3.4 h, 7.2 h, 12 h, 17 h, Selectable with rotary switch yes, max 2. 20, 10 1.3 h, 3.4 h, 7.2 h, 12 h, 17 h, No Battery, Service 0.5 min, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, 45 min,, w/0 Inversion of transistor outputs, Operation without temperature probe Yes NTC 100 kω Depending on the connected battery 96% normal mode, battery is being charged, 98% normal mode, battery is charged, 98% buffer mode < 10 W 150 / 66 / 130 mm / 980 g CE; EC; GL; GOSTME25 20...30 V DC 43 Yes max. 200 m (without battery), max. 0.5 (with fully charged battery) Yes 24 V DC ± 1 % Vo = Vin - 0.2 V normal operation (Imax), Vo = Vin - 0.3 V battery operation (Imax) 40 @ 60 C 48 @ 45 C, 24 @ 70 C, 40 @ 60 C 48 for 1 min, ED = 5 % IU characteristic curve 27, 48 V @ 20 C - 48 mv / C 0.15 C every minute 24 V 3.4 h, 7.2 h, 12 h, 17 h, Selectable with rotary switch yes, max 2. 3.4 h, 7.2 h, 12 h, 17 h, No Battery, Service 0.5 min, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, 45 min,, w/0 Inversion of transistor outputs, Operation without temperature probe Yes NTC 100 kω Depending on the connected battery 96% normal mode, battery is being charged, 98% normal mode, battery is charged, 98% buffer mode < 10 W 150 / 66 / 130 mm / 1000 g CE; EC; GL; GOSTME25 B Connection data Wire connection method Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque Nm /output/battery Signal 0.5 / 16 0.5 / 16 0.5 / 16 0.5 / 16 26 / 6 26 / 12 1.2...1.5 /output/battery Signal 0.5 / 16 0.5 / 16 0.5 / 16 0.5 / 16 26 / 6 26 / 12 1.2...1.5 Ordering data CP DC UPS 24V 20/10 1 1370050010 CP DC UPS 24V 40 1 1370040010 B.5

Battery modules Uninterruptible power supplies (UPS) Battery modules Maintenence-free lead-acid batteries from 3.4 h to 17 h Integrated temperature sensor for optimal battery charging Capacity up to 40 / 30 min or 1 / 30 hrs Robust metal housing for wall mounting wenlok.com.mx CP BTTERY 24V DC1.3H CP BTTERY 24V DC3.4H B Rated input voltage Nominal capacity Charging current, max. Overload and short circuit protection Buffer time 10 Buffer time 20 current, max. Parallel connection option Series switching capability Temperature probe General data Battery type Operating life mbient temperature Storage temperature Latest commissioning Max. perm. air humidity (operational) Class of protection Protection degree Vibration DIN rail/wall in accordance with IEC 68-2-6 Shock wall acc. to IEC 68227 Depth x width x height / Weight 24 V DC 1.3 h 0.2 15 fuse 3 min min 15 Yes No NTC 100 kω Maintenance-free GM lead-acid battery 6 9 years @ 20 C 0...+40 C (Charging); -15 +50 C (Discharging) -15 C...40 C 9 months 5 % 95 % RH III, with no ground connection, for SELV IP 20 0.7 / 0.7 g 30 g 124 / 52 / 148 mm / 1500 g culus; EC; GL 24 V DC 3.4 h 0.51 25 fuse 11.3 min 5 min 25 Yes No NTC 100 kω Maintenance-free GM lead-acid battery 6 9 years @ 20 C 0...+40 C (Charging); -15 +50 C (Discharging) -15 C...40 C 9 months 5 % 95 % RH III, with no ground connection, for SELV IP 20 0.7 / 0.7 g 30 g 137 / 108 / 144 mm / 3600 g culus; EC; GL Connection data Wire connection method Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, WG/kcmil min/max Tightening torque Nm /output/battery Signal Pluggable screw connection 0.2 / 4 0.2 / 4 0.2 / 4 0.2 / 4 30 / 12 30 / 12 0.5...0.5 /output/battery Signal Pluggable screw connection 0.2 / 6 0.2 / 1.5 0.5 / 6 0.2 / 1.5 22 / 10 28 / 16 0.5...0.6 Ordering data CP BTTERY 24V DC1.3H 1 1406930000 CP BTTERY 24V DC3.4H 1 1251070000 ccessories B.6

Battery modules CP BTTERY 24V DC7.2H CP BTTERY 24V DC12H CP BTTERY 24V DC17H Uninterruptible power supplies (UPS) B 24 V DC 7.2 h 1.08 2x25 fuse 26.5 min 11.5 min 50 Yes No NTC 100 kω 24 V DC 12 h 1.8 2x25 fuse 51 min 22.7 min 50 Yes No NTC 100 kω 24 V DC 17 h 2.55 2x25 fuse 81 min 34.2 min 50 Yes No NTC 100 kω Maintenance-free GM lead-acid battery 9 12 years @ 20 C 0...+40 C (Charging); -15 +50 C (Discharging) -15 C...40 C 9 months 5 % 95 % RH III, with no ground connection, for SELV IP 20 - / 0.7 g 30 g 134 / 162 / 155 mm / 5900 g culus; EC; GL Maintenance-free GM lead-acid battery 6 9 years @ 20 C 0...+40 C (Charging); -15 +50 C (Discharging) -15 C...40 C 9 months 5 % 95 % RH III, with no ground connection, for SELV IP 20 - / 0.7 g 30 g 134 / 229 / 155 mm / 9220 g culus; EC; GL Maintenance-free GM lead-acid battery 6 9 years @ 20 C 0...+40 C (Charging); -15 +50 C (Discharging) -15 C...40 C 9 months 5 % 95 % RH III, with no ground connection, for SELV IP 20 - / 0.7 g 30 g 160 / 242 / 178 mm / 13400 g culus; EC /output/battery Signal Pluggable screw connection 0.2 / 16 0.2 / 1.5 0.5 / 16 0.2 / 1.5 22 / 6 28 / 16 1.2...1.5 /output/battery Signal Pluggable screw connection 0.2 / 16 0.2 / 1.5 0.5 / 16 0.2 / 1.5 22 / 6 28 / 16 1.2...1.5 /output/battery Signal Pluggable screw connection 0.2 / 16 0.2 / 1.5 0.5 / 16 0.2 / 1.5 22 / 6 28 / 16 1.2...1.5 CP BTTERY 24V DC7.2H 1 1251080000 CP BTTERY 24V DC12H 1 1251090000 CP BTTERY 24V DC17H 1 1251110000 B.7

Uninterruptible power supplies (UPS) Buffer modules Buffer modules Maintenance-free UPS on capacitor basis with a capacity to support 20 / 260 ms Parallel switching to increase the output current or support time Status notification via LED and relay contact wenlok.com.mx CP DC BUFFER 24V 20 B Rated input voltage current Max. approved input current Surge protection voltage current current, max. Parallel connection option Overload protection Surge protection Status relay (max. load) Display Status indicator General data Degree of efficiency Insulation voltage, input/output Storage medium Buffer times MTBF mbient temperature (operational) Storage temperature Humidity Depth x width x height / Weight For use with electronic equipment EMC standards 24 V DC 0 22 22 31... 34 V (only at discharge) 24 V 20 22 Yes, without diode module 22 (only at discharge) 31... 34 V (only at discharge) voltage OK (30 V C/DC 2), Ready for operation (24 V C/ DC 300 m) Green LED 95 % 1 kv Internal condenser 250 ms at 20, 6 s at 1 > 500,000 h acc. to IEC 1709 (SN29500-25 C...70 C -40 C...85 C 5...95 %, no condensation 150 / 66 / 130 mm / 1150 g cc. to EN50178 / VDE0160 CE; TUEV; culus; curus Connection data Wire connection method Wire cross-section, rigid min/max Signal Ordering data CP DC BUFFER 24V 20 1 1251220000 ccessories B.8

Small metal foot Large metal foot wenlok.com.mx UPS control unit - ccessories Small plastic foot Large plastic foot Uninterruptible power supplies (UPS) Type Order No. MT 30 MF 1251320000 Type Order No. MT 45 MF 1251310000 Type Order No. MT 30 BK 1168970000 Type Order No. MT 45 BK 1962250000 B Small wall mounting Large wall mounting Temperature probe Type Order No. CP WLLDPTER 30 MM 1461870000 Type Order No. CP WLLDPTER 45 MM 1461850000 Type Cable length Order No. CP DC UPS TF25 2.5 m 1444540000 CP DC UPS TF05 0.5 m 1444480000 Small screwdriver Large screwdriver Type Blade type Size/F a b c Order No. SDIS 0.5X3.0X100 B 0.5 3 100 9008380000 Type Blade type Size/F a b c Order No. SDIS 1.0X5.5X125 B 1 5.5 125 9008410000 Markers End bracket For DIN rail TS 35 Type Colour Qty. Order No. SM 18/9.5 K MC NE WS white 200 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Order No. WEW 35/1 SW black 1.2 Nm 50 1162600000 B.9

Uninterruptible power supplies (UPS) B B.10

Contents Fuse protection for 24 V DC circuits Fuse protection for 24 V DC circuits Fuse protection for 24 V DC circuits Overview C.2 WVEGURD C.4 C C.1

Fuse protection for 24 V DC circuits Overview wenlok.com.mx Fuse protection for 24 V DC circuits C Fuse protection 24 V DC control voltage has become the standard in the automation industry. Selective fuse protection is often used when the power is being supplied by PLC-guided controllers. It divides the total load into separate, logically connected safety circuits. For example, the CPU, actuators and sensors can be separated in the load circuits. This selective load protection helps to decrease facility downtime and also to simplify troubleshooting. When a disruption (short circuit) occurs on a standard protective system, the entire power supply is interrupted. In a system using selective fuse protection, only the fuse in the one disrupted load circuit is triggered. If the fuse is triggered quick enough so that other loads (and particularly the CPU) can continue functioning properly, then various control algorithms can be used to deal with the disruption. It is then possible to shut down the facility in an orderly and controlled fashion. fundamental problem when using ordinary fuses is that they take a relatively long time to trigger. Usually, a switched-mode power supply is already well over the surgecurrent limit (typically 120 % of I nom ) before its fuse triggers. Ordinary fuses are therefore not suitable for constructing a selective fuse protective system. Such systems present DC fuses with special challenges. They must be able to switch off quickly enough but they must also be able to tolerate the start-up surge currents from consumer loads. Weidmüller s electronic fuses, from our established WVEGURD line, are the answer to both of these challenges: they are quick acting but can also tolerate start-up currents. You can easily implement selective load protection using our WVEGURD models. In addition, Weidmüller s electronic fuses feature a floating alarm contact and a reset input. This allows a PLC controller to query the status of the fuse or to perform an automated reset after troubleshooting. This provides you with a convenient method for remotely maintaining a complex facility. s a result, you save both time and money. C.2

Fuse protection for 24 V DC circuits Overview Fuse protection for 24 V DC circuits Resetting BLOCK DIGRM WVEGURD The WVEGURD family can be reset manually or by using an external signal. They can be reset remotely by simply applying a 24 V signal pulse on the reset input. The reset occurs on the falling edge of the signal. : cyclical automatic reset is not permitted and can lead to a malfunction. INPUT 24 V Reset 0V (8) (1) (7) gn re fail (9) (2) (3) OUTPUT 24 V NC contact 50 V uc /0.05 C Signalling red LED displays when the electronic fuse has been triggered. n alert is also sent out over a floating alarm contact. green LED signals that the unit is switched on. The alarm contact uses an NC contact. WVEGURD C.3

WVEGURD wenlok.com.mx Fuse protection for 24 V DC circuits 24 V DC 1.6 24 V DC 3.15 C INPUT 24 V Reset 0V (8) (1 ) (7 ) gn rt fail OUTPUT (9 ) 24 V (2 ) (3 ) NC contact 50 V uc /0.05 Current ( ) 20 18 16 14 12 10 8 6 4 2 0 Time (ms) 0 20 40 60 80 100 12 0 140 16 0 Current 24 22 20 18 16 14 12 10 8 6 4 2 0 ( ) 0 10 1520 253035 404550 5560 6570 Time (ms) Rated control voltage Rated current Reset Status relay / CO contact Signalling delay General data mbient temperature (operational) Storage temperature Status indication Standards EMC standards Sliding switch 24 V DC 1.6 Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 ; for low voltage only! 3.5 ms typ. 0 C...55 C -20 C...85 C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off ccsus; CE; curus; EC; GOSTME25 24 V DC 3.15 Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 ; for low voltage only! 3.5 ms typ. 0 C...55 C -20 C...85 C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off ccsus; CE; curus; EC; GOSTME25 Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 C, Tension single module clamp connection 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 C, Tension single module clamp connection Ordering data Tension-clamp connection WGS 24Vdc 1,6 1 8618890000 WGZ 24Vdc 1,6 1 8621040000 WGS 24Vdc 3,15 1 8618910000 WGZ 24Vdc 3,15 1 8621030000 ccessories Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2 C.4

WVEGURD 24 V DC 6.3 24 V DC 8 Fuse protection for 24 V DC circuits INPUT 24 V Reset 0V (8) (1 ) (7 ) gn rt fail OUTPUT (9 ) 24 V (2 ) (3 ) NC contact 50 V uc /0.05 Current ( ) 26 24 22 20 18 16 14 12 10 8 6 4 Time (ms) 0 10 15 20 25 30 35 40 45 50 55 60 Current ( ) 65 60 55 50 45 40 35 30 25 20 15 10 5 Time (ms) 0 5 10 15 20 25 30 35 40 45 50 C Rated control voltage Rated current Reset Status relay / CO contact Signalling delay General data mbient temperature (operational) Storage temperature Status indication Standards EMC standards Sliding switch 24 V DC 6.3 Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 ; for low voltage only! 3.5 ms typ. 0 C...55 C -20 C...85 C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off ccsus; CE; curus; EC; GOSTME25 24 V DC 8 Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 ; for low voltage only! 3.5 ms typ. 0 C...55 C -20 C...85 C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off ccsus; CE; curus; EC; GOSTME25 Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 C, Tension single module clamp connection 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 C, Tension single module clamp connection Ordering data Tension-clamp connection WGS 24Vdc 6,3 1 8618930000 WGZ 24Vdc 6,3 1 8621020000 WGS 24Vdc 8,0 1 8618940000 WGZ 24Vdc 8,0 1 8621010000 ccessories Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2 C.5

WVEGURD wenlok.com.mx Fuse protection for 24 V DC circuits 24 V DC 0.5...5 C INPUT 24 V Reset 0V (8) (1 ) (7 ) gn rt fail OUTPUT (9 ) 24 V (2 ) (3 ) NC contact 50 V uc /0.05 Rated control voltage Rated current Reset Status relay / CO contact Signalling delay General data mbient temperature (operational) Storage temperature Status indication Standards EMC standards Sliding switch 24 V DC 0.5...5 adjustable Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 ; for low voltage only! 3.5 ms typ. 0 C...55 C -20 C...85 C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off ccsus; CE; curus; EC; GOSTME25 Derating curve Dynamic tripping characteristic Tripping current: 0.5 Tripping current () 25 20 15 10 5 0 Time (ms) 0 20 40 60 80 100 120 140 Tripping current: 5.0 Tripping current () 25 20 15 10 5 0 Time (ms) 0 20 40 60 80 100 120 140 Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 C, Tension single module clamp connection Ordering data Tension-clamp connection WGS 24Vdc 0.5...5 1 8710270000 WGZ 24Vdc 0.5...5 1 8727630000 ccessories Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2 C.6

Contents Unregulated power supplies Unregulated power supplies Unregulated power supplies Overview D.2 compactpower D.4 D D.1

Unregulated power supplies Overview wenlok.com.mx Unregulated power supplies D Unregulated power supplies compactpower Compact power supply units are important links in the power supplies for controllers. They are used where processes or control voltages are required that vary from the mains voltage. Transformers provide the electrical isolation between the input circuit and the output circuit. The minimum requirement (to VDE 0550) is 2,000 V. Screw terminals secure the input-side connection to the mains. The single-phase devices are rated for a nominal voltage of 230 ± 15 V, or 400 V ± 15 V, 50/60 Hz, the 3-phase devices for 3 x 400 V ± 5 %. The secondary DC voltage from the transformer is conducted to a bridge rectifier where it is rectified. The pulsating DC voltage is then fed from the rectifier and filtered to a low residual ripple by means of an electrolytic capacitor. This DC voltage is then fed to the output terminal. These are designed as pluggable screw terminals. varistor is integrated in the output circuitry to attenuate voltage peaks. The operating status is indicated by means of a green LED via the output circuit. Devices with 600 W and higher are equipped with a fan. Single-phase unregulated power supplies Three-phase unregulated power supplies D.2