Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

Similar documents
SKDG Cable Repair Kit Instructions

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

UPC-LL Power Connection Kit

Field Installed Connectors for TraceTek 7000-HUV Bulk Cable Installation Instructions

unit 3: GENErAL ElectriCAL SySTEM DiAGNOSiS

Termination of D-621 Triaxial Connectors to Shielded Twisted Pair Cable for MIL-STD-1553B Applications

Terminating D /-0289 Subminiature SolderTact Contacts to Twisted-Pair Cable

2 Recommended Tools / Supplies

1. General Repair Methods

Terminal Replacement Procedures

AMPSEAL* Automotive Plug Connector and Header Assembly

ELECTRICAL CABLE SPLICE KIT. Roctest Limited, All rights reserved.

Service Bulletin Terminal Replacement Instructions (Replaces , dated May 2, 1995) December 18, 2000 ALL

C-L-X ARMOR REMOVAL PROCEDURES

GORE Aerospace Ethernet Cables

MiniSeal D-436 Series Sealed Crimp Splice Products Installation Guidelines

GORE Aerospace Ethernet Cables

window installation Guide wood FRaMinG New Construction

Water Level Meter: Op Instructions

Youth Explore Trades Skills

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

Crimping Instructions

3M Power Clamp Wiremount Connectors

HAND CRIMP TOOL SPECIFICATION SHEET Order No

Mat 100w/150w/200w LIFETIME INSTALLATION MANUAL WARRANTY

Miniature Waterproof Shielded Connectors

SOLDER SLEEVES AIRWORTHINESS BULLETIN. Overview. Repair and Maintenance Techniques for Wiring Systems Date : 29 July 2005.

INSTALLATION INSTRUCTION HEATSHRINK TRIFURCATING TRANSITION JOINT TO SUIT 3 CORE

Installation Instructions

Crimping Instructions

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Wiring Repair WIRING REPAIR

ROVs in a Bucket Building an Underwater Robot. 5.0 Building the Tether

OCT 15 Rev E

LAGGING PIPES UP TO 125 mm IN DIAMETER WITH K-FLEX TUBING

4200 JSP, KSP, LSP and MSP Cabinets

3M 200 Amp Loadbreak Connector System

MaxLite Linear Strip ECO Series

ELECTRICAL WIRING SOLDERING AND CRIMPING Article No. REPAIRS SERVICE TIPS

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

Signal Mirror Installation Instructions

BASIC TOOLS AND MATERIALS NEEDED. Introduction HOW TO CARE FOR YOUR DOOR

Nano v3 pinout 19 AUG ver 3 rev 1.

Experiment 3 Ohm s Law

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

Hand Crimp Tool Specification Sheet Order No

Page 1 of 18. SunRail System Installation Instructions

Pacific Antenna 20 and 40M Lightweight Dipole Kit

MIL-STD B (SH) UPDATE

HEADLIGHT CONNECTOR REPLACEMENT

HAND CRIMP TOOL SPECIFICATION SHEET Order No (Replaces (HTR1031E) And (HTR1031E1))

Miniature Waterproof Shielded Connectors

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

Wiring Techniques for Wiring a Lamp

Construction Guide: Spiderbeam 40m Add-On Dipole

Tools required by installer: Materials required by installer:

Custom Pendant- Hardwire Assembly and Installation Instructions

Pacific Antenna 20 and 40M Lightweight Dipole Kit

Zip Block MODEL ZB INSTALLATION INSTRUCTIONS

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

ACC-6SMRP2U Data Sheet

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Installation Instructions

OpenROV. Guide 3 - Electronics. We will now move to the assembly of the electronics that will control the ROV. Written By: OpenROV

S e r v i c e B u l l e t i n # doc

Features & Benefits: For Use with OSI QUAD Window & Door System. Recommended For:

VERSION 1.7 PRT-ES USER GUIDE. ZiPPERTUBiNG CO. THE. (480)

NRS Installation Manual

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

SolderSleeve One-Step Wire and Cable Terminators. Selection Guide

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

Instructions for Lighting an S Scale Caboose

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Application Note. Athearn RTR AC4400CW Tsunami Digital Sound Decoder Installation Notes

Framing & Electrical Rough-in for Recess Mount IS Panel System

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

Included in Hardware Kit 2. FLAT STYLE FENDER FLARE. Jeep Wrangler YJ. Set Part # Rev STEP 1 PRIOR TO INSTALLATION

3M No Polish SC/APC Angle Splice Connector Jacket for 2 x 3 mm FRP and 1.6 to 3.0 mm Cable 8802-T/APC/AS/1.6-3

Mat 100w/150w/200w LIFETIME INSTALLATION MANUAL WARRANTY

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

Repairing MagSafe Connector

QSLVM2500 QSLV-M Cold Shrink Insulator

Application Tooling Specification Sheet

Manual Version July 2007

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

Flat Style Fender Flares Front Pair. Jeep. Included in Hardware Kit:

Signal Mirror Installation Instructions Honda Odyssey

General Installation Instructions LED

LAND AND CONDUCTOR REPAIR (DVD-97ABC)

Technical Bulletin SSG 5.1

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

ARMA-CHEK SILVER APPLICATION MANUAL. T. +49 (0)

Signal Mirror Installation Instructions Toyota Tacoma

QUICK GUIDE. Easy Home. Wiring. Repairs. A Homeowner s Guide

Application Tooling Specification Sheet

Spiderbeam Balun Construction Guide

SONARRAY SR1 SYSTEM INSTRUCTION MANUAL

Included in Hardware Kit 2. FLAT STYLE FENDER FLARE. Jeep Wrangler YJ Fronts. Set Part # Rev STEP 1 PRIOR TO INSTALLATION

Transcription:

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable 555758 03/2018 2018 Schluter Systems L.P. DITRA and HEAT E are registered trademarks of Schluter Systems

CONTENTS 3 List of tools required and contents of the repair kit 4 Freeing the cable at the location of the break Types of repairs covered in this guide 4 Heating portion of the cable 7 Transition splice (between the gray cable and black power lead) 10 End splice (end of gray cable) Appendix: 12 A-1: Repair technician data table (Indicate the cable product no., as well as its conductor size (AWG) required to be stripped from its insulation sheathing) 13 A-2: Conductor size (AWG) table according to the heating section of the cable product no. 2 Schluter -Systems written installation instructions shall have Heating cables must be installed by a qualified precedence person over in referenced accordance industry with this standard handbook guidelines and with and the installation National Electric Code (USA) or Canadian Electric procedures Code Part insofar I (CAN) as referenced as applicable. information All electrical may connections contain overlapping must be or made by a qualified electrician, according conflicting to the electrical requirements. and building Type, thickness, codes effective and format in your of region. the ceramic or stone tile surface covering must be suitable for the intended application.

DITRA-HEAT-E-HK Heating Cable Repair Kit 1) TOOLS REQUIRED Heat gun for shrink tubes Hot glue gun and hot glue Wire stripper 10 AWG to 20 AWG Wire stripper 20 AWG to 30 AWG Wire cutter Hammer and chisel Safety glasses Utility knife Piece of cloth Ohmmeter or multimeter Megohmmeter (range set to 1000 volts) Measuring tape or ruler Felt pen or marker KIT CONTENTS Item A B C Description Heat shrink solder sleeve (small) Heat shrink solder sleeve (big) (D>d) 1 (only available in repair kit DHE-HK-SK) Copper foil D Heat shrink with sealant Ø E Heat shrink with sealant Ø 1/2" F Insulated wire (heating wire) 2 G Braided gray cable 2 1 Diameter D is larger than diameter d 2 Use 10 AWG wire stripper to strip outer grey jacket, and 20 AWG to strip the insulated wires D d WARNINGS Heating cable repairs must be conducted by a qualified technician in accordance with this heating cable repair procedure, the National Electric Code (USA) or Canadian Electric Code Part I (CAN) as applicable and the Schluter -DITRA-HEAT Installation Handbook. All electrical connections must be made by a qualified electrican, according to the electrical and building codes effective in your region. Do not use this repair kit to splice different heating cables together. The kit is only intended for making repairs within a cable. The heating cable cannot be shortened or altered to fit. Very important: Never CUT the heating cable. This could change the cable resistance and could lead to cable overheating and damage. WARRANTY DISCLAIMER: Damage to the DITRA-HEAT-E-HK heating cables voids the Schluter -DITRA-HEAT 10-Year Limited Warranty and warranty coverage is not reinstated upon repair of the heating cable. SCHLUTER SYSTEMS FURTHER DISCLAIMS ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ANY AND ALL LIABILITY ARISING FROM THE ELECTRICIAN SERVICES. 3

REPAIR PROCEDURE Before starting the repair procedure, ensure the circuit is turned OFF! Note: The repair cannot alter the resistance greater than 3% of the nominal resistance of the heating cable. 2) FREE THE CABLE WHERE THE BREAK IS LOCATED Wear safety glasses. Cover the tile with a piece of cloth and break it with a hammer. Remove the broken pieces of tile to locate the break in the heating cable. Note: At this stage, determine the cause of the cable failure. Using a chisel, free the heating cable from the mortar. Remove the mortar around the cable and within the perimeter of the tile that was broken. Clean this perimeter well. Take note of the heating cable product number (see silver identification label in junction box) and using the table provided in Appendix A-2, find the gauge of the conductor (red heating wire) and fill this information in the data table provided in Appendix A-1. 3) TYPES OF REPAIRS COVERED IN THIS GUIDE Repairing the heating portion of the heating cable (gray cable): see section 3.1. Repairing the transition splice (between the gray cable and black lead): see section 3.2. Repairing the end splice (end of gray cable): see section 3.3. 3.1) REPAIRING THE HEATING PORTION (GRAY CABLE) A) Preparing the heating cable Cut and remove the faulty section of the cable to obtain two intact segments. Free the cable to a length at least 9-1/2" (241 mm) longer than the length removed (LR) on one side, and 3-1/2" (89 mm) on the other side. (See Fig. 3.1) 4 For example: if the length removed (LR) = 2-1/2" (63.5 mm), the cable must be uncovered LR + 9-1/2" = 12" (305 mm) on one side and 3-1/2" (89 mm) on the other. Make a cavity in the floor to house the repaired joint. LR min = 2-1/2" (63.5 mm) (must be respected) LR 3-1/2" LR + 9-1/2" Fig. 3.1

Make sure that the joint does not exceed the membrane height so as not to interfere with the installation of replacement tiles. Cut the heat shrink tube Ø 1/2" (item E) to a length at least 4" (101.6 mm) longer than the length removed (LR). For example, if a section of 2-1/2" (64 mm) was removed from the heating cable, a heat shrink tube of at least 6-1/2" (165 mm) long will be required. (See Fig. 3.2). Slide the heat shrink over the longest segment of intact cable and protect it with a damp cloth. (See Fig. 3.3). Fig. 3.2 Fig. 3.3 LR + 4" LR B) Preparing heating cable ends Strip the gray sheath (outer jacket) of each section of the heating cable 1-1/2" (38 mm), using a 10 AWG wire stripper, exposing the ground braid. (See Fig. 3.4 and 3.5) 1-1/2" 1-1/2" Fig. 3.4 Be careful not to damage the tinned copper braid during this step. Push back the ground braid over the gray sheath of the heating cable to expose the heating wire. (See Fig. 3.5 and 3.6) Using a wire stripper*, strip the heating wire (6 mm) to expose the heating element (conductor). (See Fig. 3.6) Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. In order to assure that there are no additional faults in the heating cable, perform an insulation resistance test using a megohmmeter (range set to 1000 volts) between the ground braid and each conductor on both sides of the exposed cable. A successful test will provide a measurement equal to or greater than 1 Gigaohms (1 Gigaohms = 1 G ohms = 1000 Mega ohms = 1000 M ohms). Fig. 3.5 Fig. 3.6 Fig. 3.7 * Refer to appendix A-2 at the end of this document to determine the conductor size (AWG) to use with the wire stripper, based on the product no. of the heating cable to repair. C) Replacing missing section of heating cable Situation 1: If the length removed (LR) of the cable is less than 6" (152.4 mm), use the heating wire (item F) from the kit. (See Fig. 3.1 and 3.7) Fig. 3.8 4" Fig. 3.8A LR + 1/2" Prepare the cable ends as described in the previous section (Section 3.1, Point B) Situation 2: If the length removed (LR) of the cable is more than 6" (152.4 mm), use the braided gray cable (item G) from the kit (See Fig. 3.1, 3.8 and 3.8A) Fig. 3.9 5

Item G (See Fig. 3.8A) must be prepared as follows: total length of cable = LR + 1/2". Using a wire stripper, remove 4" (102 mm) of the gray insulating jacket from each end of the cable segment. Next, roll back the ground braid as shown in Fig. 3.8A and strip (6 mm) from each of the conductors. Fig. 3.10 D) Measuring, cutting and stripping the wire (item F) or the braided cable (item G, already prepared) Measure and cut the wire (item F) or the braided cable (item G, already prepared) in such a way that the ends are long enough to be in contact with the ends of the insulated wires previously stripped in step B. (See Fig. 3.9) Using a wire stripper*, strip the ends of wire (F) or cable (item G) (6 mm). (See Fig. 3.9) * Refer to appendix A-2 at the end of this document to determine the conductor size (AWG) to use with the wire stripper, based on the product no. of the heating cable to repair. Fig. 3.10A Fig. 3.10B E) Connections (steps to perform for all the joints in the repair process) Before sliding on the small heat shrink tube (item A), try as much as possible to align the 2 conductors so they are perfectly parallel. Slide a heat shrink tube with integrated solder ring (item A) on one of the conductors and then insert the replacement conductor. (See Fig. 3.9 and 3.10) Place the conductors on each side of the heat shrink tube in such a way that the bare portions overlap within the integrated solder ring. (See Fig. 3.10) Using a heat gun, adequately heat the shrink tube with integrated solder ring. The solder ring will melt and bond the two conductors together and the heat shrink will shrink completely. Cut 2" sections of heat shrink (item D) (qty 4). Slide one of these sections over item A making sure it is centered over the connection and heat to shrink. (See Fig. 3.10A and 3.10B) Fig. 3.10C Fig. 3.10D Fig. 3.10E Fig. 3.11 Slide another 2" section over the heat shrink installed in the previous step and protect it with a damp cloth. (See Fig. 3.10C) Next, slide another heat shrink with integrated solder ring (item A) over the end of the wire make sure that the bare portions of the conductors overlap within the integrated solder ring. Then, heat item A. (See Fig. 3.10D and 3.10E) Slide and center the 2" heat shrink that was protected by the damp cloth over the new connection and heat to shrink. Repeat this sequence of steps for the other conductor. (See Fig. 3.10E and 3.11) 6

F) Re-establishing the continuity of the ground braid Pull the tinned copper braided ground wire, covering the conductors on each end of the heating cable, towards the center. (See Fig. 3.12). Fig. 3.12 Align the end of the copper foil (Item C) with the gray sheath on both ends and cut. (See Fig. 3.13) C Remove the paper back protective layer, if any, from the copper foil, and slide it under the repaired joint, with adhesive on top (if any), and fold it tightly around and over it. (See Fig. 3.15) Fig. 3.13 The copper foil must have good contact with the ground braid at both ends and must not touch the gray sheath. (See Fig. 3.14 and 3.15) Before continuing, verify the repair with the following tests: Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. Perform a resistance test, using an ohmmeter or multimeter, between the two conductors. A successful test will provide a nominal cable resistance close to the one found on the cable label on the cold lead. Note: The repair cannot alter the resistance greater than 3% of the nominal resistance of the heating cable. Perform an insulation resistance test using a megohmmeter (range set to 1000 volts) between the ground braid and each conductor. A successful test will provide a measurement equal to or greater than 1 Gigaohms (1 Gigaohms = 1 G ohms = 1000 Mega ohms = 1000 M ohms). G) Placing the heat shrink (Item E) Using a felt pen or marker, mark a distance of 1" (25.4 mm) on the gray sheath from the beginning of the repaired joint. (See Fig. 3.16) Slide the black heat shrink (Item E) to the marked point in order to properly seal the repaired joint. (See Fig. 3.17) Using a heat gun, heat the heat shrink until it completely seals the gray sheath on each side of the heating cable. (See Fig. 3.18) Repeat the resistance test and the insulation resistance test as outlined at step F. Once the repair is complete and the tests pass, embed the repaired joint in the cavity using hot glue. Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. Fig. 3.14 Fig. 3.15 Fig. 3.16 Fig. 3.17 Fig. 3.18 1" 1" 7

3.2) REPAIRING THE TRANSITION SPLICE (BETWEEN GRAY CABLE AND BLACK COLD LEAD) 3-1/2" LR LR + 9-1/2" A) Preparing the heating cable and the cold lead Fig. 3.21 Cut and remove the faulty section of the cable to obtain two intact segments. Free the cable to a length at least 9-1/2". (241 mm) longer than the length removed (LR) on one side, and 3-1/2" (89 mm) on the other side. (See Fig 3.21) Fig. 3.22 LR + 5 LR For example, if the length removed (LR) = 5" (127 mm), the cable must be uncovered LR + 9-1/2 = 14.5" (368 mm) on one side and 3-1/2" (89 mm) on the other. Re-use the cavity in the floor that housed the transition splice. Make sure that the repaired joint does not exceed the membrane height so as not to interfere with the installation of replacement tiles. Fig. 3.23 Fig. 3.24 1-1/2" 1-1/2" Cut the heat shrink tube Ø 1/2" (12.7 mm) (item E) to a length at least 4" (101.6 mm) longer than the length removed (LR). For example, if a section of 5" (127 mm) was removed from the heating cable, a heat shrink tube of at least 9" (229 mm) long will be required. (See Fig. 3.22) Slide the heat shrink over the longest segment of intact cable. (See Fig. 3.23) B) Preparing each cable end Fig. 3.25 Fig. 3.26 Cold lead Heating wire Strip the black sheathing of the cold lead end and the gray sheath of the heating cable end each by 1-1/2" (38 mm) using a utility knife, exposing the ground braid. (See Fig. 3.24 and 3.25) In both cases, be careful not to damage the tinned copper braid. Push back the ground braid over the sheathed portion of each cable section to expose the insulated conductors. (See Fig 3.25 and 3.26) Using a wire stripper*, strip the cold lead wires and the heating wires (6 mm) exposing the insulated conductors. (See Fig 3.26) * Refer to Appendix A-2 at the end of this document to determine the conductor size (AWG) to use with the wire stripper, based on the product no. of heating cable to repair. 8

Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. In order to assure that there are no additional faults in the heating cable, perform an insulation resistance test using a megohmmeter (range set to 1000 volts) between the ground braid and each conductor on both sides of the exposed cable. A successful test will provide a measurement equal to or greater than 1 Gigaohms (1 Gigaohms = 1 G ohms = 1000 Mega ohms = 1000 M ohms). Fig. 3.27 (Item F) Fig. 3.28 (Item G) C) Replacing missing section of the heating cable Situation 1: If the length removed (LR) of the cable is less than 6" (152 mm), use the heating wire (item F) from the kit. (See Fig. 3.21 and 3.27) Prepare the cable ends as described in the previous section (B). Situation 2: Fig. 3.29 14 AWG wire If the length removed (LR) of the cable is more than 6" (152 mm), use the braided gray cable (item G) from the kit (See Fig. 3.21 and 3.28) Fig. 3.29A Item B Item A Prepare the cable as shown in Fig 3.28A. Note: 4" (101.6 mm) of the gray sheath from item G must be removed for the side facing the gray heating cable, and 1-1/2" must be removed from it for the side facing the black cold lead. Fig. 3.30 D) Measuring, cutting, and stripping the insulated wire (item F) or the braided gray cable (item G) D d Measure and cut the insulated wire (F) or the braided gray cable (G) in such a way that the ends are long enough to be in contact with the ends of the insulated wires previously stripped. (See Fig 3.29) Fig. 3.30A: The diameter of D is larger than d (ØD > Ød) Using a 20 AWG wire stripper, strip the ends of wire (F) or cable (G) (6 mm). (See Fig 3.29) E) Connections Cut heat shrink tubing item D to a length of 2" (50.8 mm). Two pieces are required to cover heat shrink solder sleeve item A for each wire at a later stage. Slide a heat shrink with integrated solder ring (item B) on one of the cold lead conductors (14 AWG), and then insert one of the replacement heating wire conductor. (See Fig. 3.29A and 3.30A) Place the conductors on each side of the shrink tube in such a way that the bare portions overlap within the integrated solder ring. The cold lead conductor and heating wire conductor must be adjacent to one another. (See Fig. 3.30) Caution: insert the larger diameter D on the 14 AWG 9

wire. (See Fig. 3.29A and 3.30A) Using a heat gun, adequately heat the shrink tube with integrated solder ring. The solder ring will melt and bond the two conductors together and the heat shrink will shrink completely. (See Fig. 3.30B) Slide a 2" heat shrink with sealant (item D) over the heat shrink installed in the previous step and protect it with a damp cloth. Next, slide a heat shrink with integrated solder ring (item A) over the end of the replacement conductor and insert one of the heating wire conductor so that so that the stripped portions overlap within the integrated solder ring. Fig. 3.30B: Protect item D with a damp cloth Fig. 3.30C: Protect item D with a damp cloth Using a heat gun, heat the shrink tube until the integrated solder ring has completely melted. (See Fig. 3.29A and 3.30C) Slide and center the 2" (50.8 mm) heat shrink that was protected by the damp cloth over the new connection and heat to shrink. (See Fig. 3.30D) Fig. 3.30D Repeat this sequence of steps for the other conductor. (See Fig. 3.31) F) Re-establishing the continuity of the ground braid Pull the tinned copper braided ground wire, covering the conductors on each end of the heating cable, towards the center. (See Fig. 3.32) Align the end of the copper foil (Item C) with the gray sheath on one end and the black sheath on the other end and cut. (See Fig. 3.33) Remove the paper back protective layer, if any, from the copper foil, and slide it under the repaired joint with adhesive on top, if any, (See Fig. 3.34) and fold it tightly around and over it. (See Fig. 3.35) The copper foil must have good contact with the ground braid at both ends and must not touch either the gray sheath or the black sheath at each end. (See Fig. 3.34 and 3.35) Before continuing; verify the repair: Fig. 3.31: Push the heat-shrink tubing further back and cover with damp cloth before soldering tubes. Fig. 3.32 Fig. 3.33 Fig. 3.34 Fig. 3.35 Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. Perform a resistance test, using an ohmmeter or multimeter, between the two conductors. A successful test will provide a nominal cable resistance close to the one found on the cable label on the cold lead. Note: The repair cannot alter the resistance greater than 3% of the nominal resistance of the heating cable. 10 Perform an insulation resistance test using a megohmmeter

(range set to 1000 volts) between the ground braid and each conductor. A successful test will provide a measurement equal to or greater than 1 Gigaohms (1 Gigaohms = 1 G ohms = 1000 Mega ohms = 1000 M ohms). Placing the heat shrink. (item E): Using a felt pen or marker, mark a distance of 1/2" (13 mm) on the gray sheath of the heating cable from the beginning of the repaired joint. (See Fig. 3.36) Fig. 3.36 Fig. 3.37 1/2" Slide the black heat shrink (Item E) to the marked point in order to properly seal the repaired joint. (See Fig. 3.37 and 3.37A) Using a heat gun, heat the heat shrink until it completely seals the gray sheath on each side of the heating cable. (See Fig. 3.38 and 3.38A) Repeat the resistance test and the insulation resistance test as outlined in step F. Once the repair is complete and the tests pass, embed the repaired joint in the cavity using hot glue. Fig. 3.37A: Align the heat-shrink tube with the line. Fig. 3.38 Fig. 3.38A 3.3) REPAIRING THE END SPLICE (END OF GRAY HEATING CABLE) A) Stripping procedure to expose the ground braid Cut the defective end splice completely (complete portion having black heat shrink) and remove it. Free the heating cable from the mortar and make sure to have a minimum of 3" (76.2 mm) available for the repair. Strip the gray sheath (outer jacket) 1- (31.8 mm). (See Fig. 3.40) Be careful not to damage the tinned copper braid during this step. Fig. 3.40 Fig. 3.41 B) Unbraiding and preparing for soldering Pull the ground braid back over the non-stripped portion of the cable to expose the insulated conductors. (See Fig. 3.41) Use wire strippers to strip 5/8" (16 mm) of the insulation from both conductors. (See Fig. 3.42) * Refer to appendix A-2 at the end of this document to determine the conductor size (AWG) to use with the wire stripper, based on the product no. of heating cable to repair. Twist the copper strands together. (See Fig. 3.43) Fig. 3.42 Fig. 3.43 5/8" C) Soldering Slide the heat shrink with integrated solder ring (item B) over the conductors making sure that the integrated solder ring is centered over the twisted bare conductors. (See Fig. 3.44) Fig. 3.44 11

Using a heat gun, adequately heat the heat shrink and integrated solder ring making sure the solder melts and the shrink provides a good seal. Pull the tinned copper braid ground wires over the the heat shrink solder sleeve which was previously heated and shrunk. (See Fig. 3.45) D) Verify the repair Before continuing, verify the repair. Note: Undo the thermostat connections to the heating cable in the junction box, in order to verify the repair. Perform a resistance test, using a ohmmeter or multimeter between the two conductors. A successful test will provide a nominal cable resistance close to the one found on the cable label on the cold lead. Note: The repair cannot alter the resistance greater than 3% of the nominal resistance of the heating cable. Perform an insulation resistance test using a megohmmeter (range set to 1000 volts) between the ground braid and each conductor. A successful test will provide a measurement equal to or greater than 1 Gigaohms (1 Gigaohms = 1 G ohms = 1000 Megaohms = 1000 M ohms). E) Heat shrink tube (item D) Make a mark, using a felt pen or marker, at a distance of 1/2" (12 mm) on the gray sheath. (See Fig. 3.46) Cut a 3" section of heat shrink (item D) Slide the black heat shrink (Item D) to the marked point in order to properly seal the repaired joint. Using a heat gun, heat the heat shrink until it completely seals the gray sheath on the heating cable. (See Fig. 3.47 and 3.48) Pinch the heat shrink at the end of the cable using pliers to properly seal the termination point. (See Fig. 3.48) F) Anchor the cable to the floor Make a groove in the floor to accommodate the repair. Anchor the repaired cable using hot glue. Make sure the repaired joint does not interfere with the laying of the replacement tile or tiles. Repeat the resistance test and the insulation resistance test as outlined in step D. Fig. 3.45 Fig. 3.46 Fig. 3.47 Fig. 3.48 1/2" 12

Appendix A-1: Repair Technician Data Table SUMMARY OF WIRE SIZES (AWG) Supplied with the repair kit Item F Cable being repaired Cold lead (black) 14 AWG 20 AWG Utility knife Be careful not to damage the braid Item G Heating cable (grey) 10 AWG 20 AWG 10 AWG Varies depending on product. See appendix A-2 Be careful not to damage the braid Be careful not to damage the braid DATA TABLE (AWG) Repair Product number AWG (appendix A-2) A B C D E 13

Appendix A-2 CABLE PRODUCT NO. AND THEIR HEATING CONDUCTOR SIZES (AWG) Product number (120 V) Heating conductor size (AWG)* DHEHK12011 27 DHEHK12016 27 DHEHK12021 25 DHEHK12027 26 DHEHK12032 24 DHEHK12038 26 DHEHK12043 25 DHEHK12051 23 DHEHK12064 26 DHEHK12073 25 DHEHK12083 24 DHEHK12092 23 DHEHK120102 22 DHEHK120113 21 DHEHK120134 20 Product number (240 V) Heating conductor size (AWG)* DHEHK24011 28 DHEHK24016 26 DHEHK24021 27 DHEHK24027 25 DHEHK24032 27 DHEHK24038 27 DHEHK24043 25 DHEHK24053 26 DHEHK24064 24 DHEHK24075 26 DHEHK24085 25 DHEHK240103 23 DHEHK240129 26 DHEHK240145 25 DHEHK240167 24 DHEHK240183 23 DHEHK240204 22 DHEHK240225 21 DHEHK240269 20 14 * Recommended wire stripper size to remove insulation from conductor.