Spiral gypsum plasterboard fixing No pre-drilling: in single sheet gypsum plasterboard No surface cracking due to special thread geometry High load bearing values up to 8 kg in gypsum plasterboard per fixing point PZ2 drive for easy installation www. You Tube.com/toxgermany Description & application Glass fibre-reinforced plasterboard fixing Reinforced centring tip for simple installation with no additional setting tool For single sheet gypsum plasterboard Spiral + screw: with PZ2 drive Handling & installation Centre-punch the gypsum plasterboard using the centring tip before starting to screw in 1. Insert fixing 3. Turn the screw Not suitable for gypsum fibre board and tiled gypsum fibre board Short fixing length means little space required behind the board Use only chipboard and self-tapping screws with ø 4.5 Minimum screw length = fixing length 32 + thickness of the object to be mounted 2. Position the object to be mounted Result behind boards Pre-positioned installation 144
Building materials & load bearing values Spiral 9.5 12.5 2x 12.5 Gypsum fibre board 12.5 32 7 kg 8 kg - - - Splint/ plywood 10 When fixing in gypsum plasterboards, the board manufacturer's load bearing values must be observed at all times. Approved fixings must be used for mountings where safety is a factor (see also fixing 1x1). Packaging Art. no. Type Ø length size Drill Ø Min. cavity depth Board thickness Size of object to be mounted Approval Spiral 068 100 231 32 50x - ø - 32 4.5 ø - 25* 20 - - Spiral + screw 068 101 231 32 S 50x 50x - 32 4.5 x 45 ø - 25* 20 22 - Spiral 068 260 23 32 70x - ø - 32 4.5 ø - 25* 20 - - Spiral + screw 068 261 23 32 S 45x 45x - 32 4.5 x 45 ø - 25* 20 22 - Spiral 068 700 231 32 10x - ø - 32 4.5 ø - 25* 20 - - Spiral + screw 068 701 231 32 S 4x 4x - 32 4.5 x 45 ø - 25* 20 22 - * With 9.5 gypsum plasterboard. For other boards, 23 is sufficient. 145
Spiral Plus gypsum plasterboard fixing No pre-drilling: In gypsum plasterboard in directly No special tool required Very high load bearing values up to 20 kg in gypsum fibre board per fixing point www. You Tube.com/toxgermany Description & application Metal fixing (zinc die-casting) with drill bit and distinct outer thread Also suitable for double sheet gypsum plasterboard PZ2 drive for easy installation Spiral Plus + screw: with PZ2 drive Handling & installation Not suitable for tiled gypsum plasterboard Pre-drill gypsum fibre boards with 8 Short fixing length means little space required behind the board Use only chipboard and self-tapping screws with ø 4.5 Minimum screw length = fixing length 32 + thickness of the object to be mounted Centre-punch the board's cardboard cover before installing fitting Flush wall connection Pre-positioned installation 1. Insert fixing 2. Position the object to be mounted 3. Turn the screw Result behind boards 146
Building materials & load bearing values Spiral Plus 9.5 12.5 2x 12.5 Gypsum fibre board 12.5 37 7 kg 8 kg 15 kg 20 kg - Splint/ plywood 10 When fixing in gypsum plasterboards, the board manufacturer's load bearing values must be observed at all times. Approved fixings must be used for mountings where safety is a factor (see also fixing 1x1). Packaging Art. no. Type Ø length size Drill Ø Min. cavity depth Board thickness Size of object to be mounted Approval Spiral Plus 068 100 021 37 50x - - 32 4.5 5.0 ø - 28 25 - - Spiral Plus + screw 068 101 021 37-2 S 50x 50x - 32 4.5 x 35 ø - 28 25 12 - Spiral Plus + screw 068 101 041 37-4 S 50x 50x - 32 4.5 x 50 ø - 28 25 27 - Spiral Plus + screw 068 701 041 37-4 S 4x 4x - 32 4.5 x 50 ø - 28 25 27-147
Spiral Pro gypsum plasterboard fixing No pre-drilling in gypsum plasterboard No special tool required in directly No special tool required Extremely high load bearing values up to 25 kg in gypsum plasterboard per fixing point Spiral Pro + screw: Same bit for turning in the fixing and the screw www. You Tube.com/toxgermany Description & application Metal fixing (zinc die-casting) with drill bit, toggle blade and distinct outer thread PZ2 drive Toggle blade for high load bearing values Spiral Pro + screw: with PZ2 drive Handling & installation Not suitable for tiled wall boards Suitable for board thicknesses of 9 13 Short fixing length means little space required behind the board Use only the screws supplied Pre-drill gypsum fibre boards with 11 Pre-positioned installation 1. Insert fixing 2. Position the object to be mounted 3. Turn the screw Result behind boards 148
Building materials & load bearing values Spiral Pro 9.5 12.5 2x 12.5 Gypsum fibre board 12.5 39 10 kg 15 kg - 25 kg - Splint/ plywood 10 When fixing in gypsum plasterboards, the board manufacturer's load bearing values must be observed at all times. Approved fixings must be used for mountings where safety is a factor (see also fixing 1x1). Packaging Art. no. Type Ø length size Drill Ø Min. cavity depth Board thickness Size of object to be mounted Approval Spiral Pro + screw 068 101 031 39-3 S 50x 50x - 39 4.5 x 45 ø - 30 9 13 12 - Spiral Pro + screw 068 101 051 39-5 S 25x 25x - 39 4.5 x 60 ø - 30 9 13 27 - Spiral Pro + screw 068 701 051 39-5 S 4x 4x - 39 4.5 x 60 ø - 30 9 13 27-149
Spagat spring toggle fixing Automatic toggle fixing with springloaded expansion To bridge large wall thicknesses For single and double sheet wall boards Independent bridging Automatic toggle fixing Description & application Galvanised zinc-plated cavity toggle fixing made from metal with two toggle blades, metal washer and knurled nut Handling & installation Note minimum cavity depth, board thickness and drill Ø (see table on the left) Note vertical installation position for wall installation Pre-positioned installation 1. Drill 2. Insert fixing 3. Turn the screw Result behind boards 150
Building materials & load bearing values Spagat 9.5 12.5 2x12.5 Gypsum fibre board 12.5 M3 15 kg 20 kg 40 kg 10 kg 15 kg M4 15 kg 20 kg 40 kg 10 kg 20 kg M5 15 kg 20 kg 40 kg 10 kg 30 kg M6 15 kg 20 kg 40 kg 10 kg 40 kg Splint/ plywood 10 When fixing in gypsum plasterboards, the board manufacturer's load bearing values must be observed at all times. Approved fixings must be used for mountings where safety is a factor (see also fixing 1x1) Packaging Art. no. Type Washer Ø length Thread Drill Ø Min. cavity depth Min. insertion depth Min. anchorage depth Approval Spagat 024 100 011 M3 50x 20x5.3x0.5 024 100 111 M3 20x 20x5.3x0.5 024 100 061 M4 50x 20x5.3x0.5 024 100 161 M4 20x 20x5.3x0.5 024 100 091 M5 25x 25x6.4x1.0 024 100 191 M5 10x 25x6.4x1.0 024 100 141 M6 25x 25x6.4x1.0 dl metric - 85 M3-85 M3-90 M4-90 M4-100 M5-100 M5-100 M6 / d1 ø h1 hef (+1) 12 / 4 30-70 - 12 / 4 30-70 - 14 / 5 35-70 - 14 / 5 35-70 - 18 / 6 45-80 - 18 / 6 45-80 - 18 / 7 50-80 - Spagat 024 700 011 M3 2x 20x5.3x0.5 024 700 061 M4 2x 20x5.3x0.5 024 700 091 M5 2x 25x6.4x1.0 dl metric - 85 M3-90 M4-100 M5 / d1 ø h1 hef (+1) 12 / 4 30-70 - 14 / 5 35-70 - 18 / 6 45-80 - h1 d1 1 dl 151
Spagat Pro toggle fixing Extremely high load bearing values in cavities Ideally suited for wall installation Universal attachment points with hexagonal screws To bridge large wall thicknesses For single and double sheet boards During wall installation, the tilt mechanism independently orients itself to the optimum angle for the load Description & application Galvanised zinc-plated metal cavity fixing with a toggle blade, a threaded rod, a large and small metal washer and two hexagonal nuts (SW 13) For wall and ceiling installation For gypsum plasterboard, gypsum fibre board and chipboard as well as hollow brick and pre-stressed concrete hollow ceiling boards Handling & installation Note minimum cavity depth, board thickness and drill Ø (see table on the left) Note vertical installation position for wall installation Pre-positioned installation 1. Drill 4. Turn the screw 2. Insert fixing Result behind boards 3. Position object to be mounted 152
Building materials & load bearing values Spagat Pro 9.5 12.5 2x12.5 Gypsum fibre board 12.5 M8 20 kg 40 kg 120 kg 35 kg 200 kg Splint/ plywood 10 When fixing in gypsum plasterboards, the board manufacturer's load bearing values must be observed at all times Approved fixings must be used for mountings where safety is a factor (see also fixing 1x1) Packaging Art. no. Type Width across Washer length Thread Drill Ø Min. cavity depth Min. insertion depth Size of object to be mounted Approval Spagat Pro per pack SW 023 100 071 M8 20x 13 023 100 171 M8 10x 13 small / large lg metric 16 / 30 100 M8 16 / 30 100 M8 / d1 ø h1 hef (+1) 20 / 10 75-60 - 20 / 10 75-60 - h 1 l g d 0 d1 d p t fi x 1 t fi x 16 30 153
toggle bolt Spagat Plus NEW PRODUCT Extremely high retaining values for pore volumes Suitable for metric screws For board thicknesses of 9.5-70 * Tilting mechanism will adjust automatically to the angle most suitable for the load capacity No setting tools required Simple and quick installation *a longer screw mig need to be used Packaging Order no. Type Content Content Ø Drive size Drill Ø min. depth Board thickness Strength attachment Approval part Spagat Pro per package ø dp ETA 036 600 021 M5 2x 2x 036 600 041 M6 2x 2x - PH2 M5x60 - PH3 M6x60 13 55 9.5-70 50 1-13 55 9.5-70 50 1-1 depending on board thickness
Materials & Retaining values Spagat Plus Sheetrock board 9.5 Sheetrock board 12.5 Sheetrock board 2x12.5 Fibre reinforced plasterboard 12.5 M5 20 kg 25 kg 50 kg 40 kg 60 kg M6 20 kg 30 kg 55 kg 45 kg 65 kg For fixings in sheetrock, the retaining value indication of the board manufacturer must be observed Use certified fixings for safety-relevant fastenings (refer also to the TOX guide for choosing the rig fixing) Chipboard / Plywood board 10 Description & Area of application fixing with variable length from plastic with metal tilting wings For wall and ceiling installations For sheetrock boards, fibre reinforced plaster boards and plywood as well as hollow bricks and pre-stressed hollow core concrete slabs Handling & Installation Observe minimum cavity depth, board thickness and drill bit Ø (refer to table on the left) 1. Drill 5. in screw Observe vertical installation position for wall installations Pre-positioning installation Position screw with little pressure and screw in 2. Set fixing Result in construction material 3. Fasten fixing 4. Remove installation aid
Metal cavity fixing Acrobat Rotary protection Quick handling with mounting pliers (can be installed without mounting pliers) For small cavity depths cap with rotary protection prevents rotation in the construction material Suitable for single and double wall board layers dd M www. You Tube.com/toxgermany Packaging Order no. Type Content Content Ø length size Drive Drill Ø min. depth Board thickness Strength attachment part Approval Acrobat pro Pack pro Pack dd ø ETA 035 101 021 M4 x 32 50x 50x 035 101 031 M4 x 38 50x 50x 035 101 061 M5 x 37 50x 50x 035 101 071 M5 x 52 50x 50x 035 101 081 M5 x 65 25x 25x 035 101 111 M6 x 37 25x 25x 035 101 121 M6 x 52 25x 25x 035 101 131 M6 x 65 25x 25x 8 32 M4 x 39 PH2 8 38 M4 x 45 PH2 10 37 M5 x 45 PH2 10 52 M5 x 58 PH2 10 65 M5 x 71 PH2 12 37 M6 x 45 PH3 12 52 M6 x 58 PH3 12 65 M6 x 71 PH3 8 35 3-11 23-8 35 8-16 20-10 37 6-13 21-10 48 7-18 28-10 51 17-32 28-12 37 6-13 21-12 48 7-18 28-12 51 17-32 28 - Acrobat pro Pack pro Pack dd ø ETA 035 101 171 M8 x 55 25x 25x 035 101 181 M8 x 68 25x 25x 12 55 M8 x 60 SW13 12 68 M8 x 71 SW13 12 55 8-16 26-12 55 17-32 27 - Acrobat pro Pack pro Pack dd ø ETA 035 701 021 M4 x 32 4x 4x 8 32 M4 x 39 PH2 8 35 3-11 23-035 701 031 M4 x 38 4x 4x 8 38 M4 x 45 PH2 8 35 8-16 20-035 701 061 M5 x 37 4x 4x 10 37 M5 x 45 PH2 10 37 6-13 21-035 701 071 M5 x 52 4x 4x 035 701 081 M5 x 65 4x 4x 035 701 111 M6 x 37 4x 4x 10 52 M5 x 58 PH2 10 65 M5 x 71 PH2 12 37 M6 x 45 PH3 10 48 7-18 28-10 51 17-32 28-12 37 6-13 21-035 701 121 M6 x 52 4x 4x 12 52 M6 x 58 PH3 12 48 7-18 28-035 701 131 M6 x 65 2x 2x 12 65 M6 x 71 PH3 12 51 17-32 28 - Acrobat pro Pack pro Pack dd ø ETA 035 701 171 M8 x 55 2x 2x 035 701 181 M8 x 68 2x 2x 12 55 M8 x 60 SW13 12 68 M8 x 71 SW13 12 55 8-16 26-12 55 17-32 27 -
Materials & Retaining values Acrobat Sheetrock board 9.5 Sheetrock board 12.5 Sheetrock board 2x12.5 For fixings in sheetrock, the retaining value indication of the board manufacturer must be observed Use certified fixings for safety-relevant fastenings (refer also to the TOX guide for choosing the rig fixing) Fibre reinforced plasterboard 12.5 M4x32 15 kg - - - 25 kg M4x38 15 kg 20 kg - - 25 kg M5x37 15 kg 20 kg - 30 kg 30 kg M5x52 15 kg 20 kg - 30 kg 30 kg M5x65 - - 20 kg - - M6x37 15 kg 20 kg - 30 kg 30 kg M6x52 15 kg 20 kg - 30 kg 30 kg M6x65 - - 35 kg - - M8x55 15 kg 25 kg - - 30 kg M8x68 - - 35 kg - - Chipboard / Plywood board 10 Description & Area of application Galvanised metal cavity fixing with fixing cap, rotary protection and metric screw with hexagon (SW13) or cross slotted head When placing the fixing, the expansion elements will expand over a large surface on the back of the board Handling & Installation The fixing should be installed with the TOX mounting pliers Acrobat Speed-Plus or Acrobat Speed-Pro, if possible, but installation with an electric drill or screwdriver is possible as well Make sure to use the defined drill Ø The rotary protection can be pressed back into the original form, if required (e.g. on tiled sheetrock boards) Observe minimum cavity depth and board thickness The bore hole in sheetrock boards must be made with a wood or metal drill Fire resistant according to DIN 4102 (class A1) Pre-positioning installation 1. Drill 2. Set fixing Result behind boards 3. Tigen with mounting pliers 4. in screw
Acrobat Speed-Plus installation tongs Install in one process in just Continuous installation without readjusting the screw Fast and convenient Acrobat installation Short design for confined spaces Comfort handle to make working comfortable and safe Packaging Art. no. Contents Acrobat Speed-Plus www. You Tube.com/toxgermany 035 900 94 1x Description & application For fixing the Acrobat Metal installation tongs with tongs head, two tongs handles with anti-slip device Larger screw slot ensures secure expansion of the Acrobat Handling & installation Place the fixing with screw head in the slot on the tongs head Activate the tong handles several times to install the fixing Lift the tongs sligly to release the Acrobat and secure the object Pre-positioned installation 1. Drill 2. Place fixing in tong head 5. Loosen screw 6. Turn the screw 3. Insert in the drill hole Result behind boards 4. Tigen with installation tongs 156
Acrobat Speed-Pro professional installation tongs Robust, high-quality professional design Fast and simple Acrobat installation Anti-trapping device on the handle Packaging Art. no. Contents Acrobat Speed-Pro 035 900 92 1x Description & application For fixing the Acrobat Metal installation tongs with tongs head, two tongs handles with anti-slip device and safety lever Handling & installation Place the fixing with the screw head in the slot on the tong head Insert the fixing in the drill hole Press the tong handles together Release the tongs If the fixing has not expanded fully, turn the screw sligly into the fixing and repeat the previous steps 1. Drill 2. Place fixing in tong head 5. Loosen screw 6. Turn the screw 3. Insert in the drill hole Result behind boards 4. Tigen with installation tongs 158