Report No. 071L112-RFCEP02V01-A. Test Report. Model No. MS-1719 Transmitter Module. Intel / 4965AGN. Date of Receipt Jan. 23, 2007

Similar documents
Report No. 074L001-RFCEP02V01. Test Report. Model No. MS-1221, PR200 Transmitter Module. Intel / 4965AGN. Date of Receipt Mar.

Report No R-RFCEP02V01. Test Report. Model No. MS-163C Transmitter Module. Intel / 4965AGN. Date of Receipt July 03, 2007

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1223, MS-1331 Transmitter Module. MSI / MS Date of Receipt Apr.

Report No R-RFCEP02V01. Test Report. Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. MSI / MS Date of Receipt Jul.

Report No R-RFCEP02V01. Test Report. Model No. MS-163A,GX600,GX600X Transmitter Module. Intel / 4965AGN

Report No R-RFCEP02V01. Test Report. Model No. MS-6638, AE 1900 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1674, EX620 Transmitter Module. MSI / MS-6890

Test Report MS-1651, GX620, GT620. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Report No R-RFCEP02V01-B. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. Atheros / AR5BXB63

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1452, EX460, EX461 Transmitter Module. MSI / MS-6891

Report No R-RFCEP02V01-A. Test Report. Product Name Notebook Model No. MS-1731 Transmitter Module MSI / MS-6894

Report No R-RFCEP02V01. Test Report. Model No. MS-N033,U123 Transmitter Module. MSI / MS-6894

Report No R-RFCEP02V01-A. Test Report MS-1644, PR621, PR621X

Test Report. Model No. MS-1049, MS-1049B, L710, 7100U Series (with MS-6833)

Report No. 09C136R-RFCEP76V01-B. Test Report. Product Name Notebook Model No. MS-1681, CR620, A6200 Transmitter Module MSI / MS-3870

Report No. 062L020-RF-CE-P02V01-1. Test Report. MS-1034, MS-1034B, MS-10341, MS-10341B, MS-10342, MS-10342B Transmitter Module.

Report No R-RFCEP76V01. Test Report

Report No R-RFCEP02V01. Test Report. Date of Receipt Apr. 28, Issued Date May. 23, 2008

Test Report. Model No. MS-6421, Media Live Transmitter Module. MSI / MS-6874

Report No. 062L020-RF-CE-P02V01-2. Test Report. Model No. MS-1613 Transmitter Module. Intel / WM3945ABG. Date of Receipt Dec.

Report No R-RFCEP02V01. Test Report. Date of Receipt Jun. 04, Issued Date Jul. 21, 2008

Report No R-RFCEP02V01. Test Report MS-1644, PR621, PR621X

Test Report. Applicant MICRO-STAR INT L CO., LTD Address No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan. Date of Receipt Dec.

Test Report. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan. Date of Receipt Mar.

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Test Report. MS-1031,M640,6400,6400 series. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

Report No R-RFCEP76V01. Test Report

Report No R-RFCEP76V01. Test Report MS-6681, DC520, DE520

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS Date of Receipt : Apr. 22, Date of Test : May 09, Report No.

Report No R-RFCEP76V01. Test Report

CERTIFICATE. Issued Date: Sep. 21, 2007 Report No.: R-ITCEP07V04. : HMLCD19L, HMLCD19xxxxx (X=0~9, A~Z) : Honeywell Video Systems

Report No R-RFCEP76V01-A. Test Report

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

Test Report. Product Name : MEGABOOK Model No. : MS-1010, M620

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

Report No. 11B347R-RFCEP76V01. Test Report

Report No: 073L039-RFCEP17V01. Test Report. Applicant MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Test Report. Product Name : IPC Model No.

Test Report. : 09A255R-ITCEP28V01 Report Version : V1.0

Test Report. Wireless 11g + Bluetooth Combo MiniPCI Card. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

Test Report. Applicant : ICP DAS Co., LTD Address : No. 111, Kuang-Fu N. Rd., Hsin-Chu Industrial Park, Hukou Shiang, HSINCHU 303, Taiwan

Report No: R-RFCEP14V02. Test Report. For:Intel

Test Report. Applicant ICP DAS CO., LTD. Address No. 111, Kuangfu N. Rd., Hukou Shiang, Hsinchu, Taiwan 303, R.O.C.

Test Report : ITB-010

CERTIFICATE. Issued Date: Aug. 22, 2008 Report No.: R-ITCEP07V03 This is to certify that the following designated product

CERTIFICATE. Issued Date: July 27, 2007 Report No.: 076L030-ITCEP07V03

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Test Report. Product Name : MEGA BOOK Model No. : MS-1049, MS-1049B, L710, 7100U Series

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Test Report. Applicant : Moxa Networking Co., Ltd. Address : Fl.8, No.6, Alley 6,Lane 235, Pao-Chiao Rd. Shing Tien City, Taiwan, R.O.C.

Report No.: R-RFCEP14V01. Test Report

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : 2000 IEC Edition 1.

CERTIFICATE EN 55022: 2006 EN 55024: 1998+A1: 2001+A2: EN :2006 IEC Edition 1.2: (Level 3)

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

1 SUMMARY OF STANDARDS AND RESULTS

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Test Report. Product Name : MEGA BOOK Model No. : MS-1022, S425, S425B

CE TEST CERTIFICATION

CERTIFICATE EN 55022: 2006+A1: 2007 EN 55024: 1998+A1: 2001+A2: 2003

CERTIFICATE. Issued Date: Jul. 22, 2009 Report No. : R-ITUSP02V02

CE TEST CERTIFICATION

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC Test report for LED Panel Light Models , , , , ,

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

EMC VERIFICATION SUMMARY Report No.: SZHH

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

CERTIFICATE. Issued Date: May 21, 2008 Report No.: R-ITUSP02V01

Test Report. Product Name : b P3 Wireless LAN PCMCIA Card Model No. : WN-110 FCC ID : QDWWN110

CERTIFICATE. Issued Date: Aug. 20, 2009 Report No.: R-ITUSP02V01

Report No R-RFCEP39V01. Test Report. For:Intel

CE EMC Test Certification

Report No: R-RFCEP38V01. Test Report

Report No R-RFUSP28V01. FCC Test Report. Applicant Fluidmesh Networks, LLC Barlcay Blvd.,Buffalo Grove, IL USA

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

CERTIFICATE. Issued Date: Oct. 18, 2010 Report No.: 10A097R-ITCEP07V03

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: 2003

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT. according to

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

CERTIFICATE. Product : IPC Trade name : VISION BOX Model Number : VB-115C/VB-115H/VB-115C-XXX/VB-115H-XXX Company Name : ICPDAS CO.

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

CERTIFICATE EN 55022: 2006 EN 55024: 1998+A1: 2001+A2: EN :2006 IEC Edition 1.2:

Transcription:

Test Report Product Name Notebook Model No. MS-1719 Transmitter Module. Intel / 4965AGN Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Date of Receipt Jan. 23, 2007 Issued Date Apr. 19, 2007 Report No. 071L112-RFCEP02V01-A The Test Results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Page: 1 of 50

Test Report Certification Issued Date: Apr. 19, 2007 Report No.: 071L112-RFCEP02V01-A Accredited by DNV, Nemko and NIST (NVLAP) Product Name Applicant Address Manufacturer Model No. Rated Voltage EUT Working Voltage Trade Name Notebook MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. MICRO-STAR INT L Co., LTD. MS-1719 AC 230V/50Hz AC 230V/50Hz MSI Applicable Standard ETSI EN 301 489-17:V1.2.1 (2002-08) ETSI EN 301489-1: V1.6.1 (2005-09) Test Result Complied The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Documented By : ( Senior Engineering Adm. Specialist / Anita Chou ) Tested By : Approved By : (Assistant Engineer/ Tom Hsieh ) (President /Gene Chang ) 0914 Page: 2 of 50

TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION...5 1.1. EUT Description...5 1.2. Tested System Details...7 1.3. Configuration of Test System...8 1.4. EUT Exercise Software...8 1.5. Test Facility...9 2. Conducted Emission...10 2.1. Test Equipmen...10 2.2. Test Setup...10 2.3. Limits...11 2.4. Test Procedure...12 2.5. Test Specification...12 2.6. Uncertainty...12 2.7. Test Result...12 3. Radiated Emission...13 3.1. Test Equipment...13 3.2. Test Setup...13 3.3. Limits...14 3.4. Test Procedure...14 3.5. Test Specification...14 3.6. Uncertainty...14 3.7. Test Result...14 4. Power Harmonics, Voltage Fluctuation and Flicker...15 4.1. Test Equipment...15 4.2. Test Setup...15 4.3. Limits...15 4.4. Test Procedure...16 4.5. Test Specification...16 4.6. Uncertainty...16 4.7. Test Result...16 5. Electrostatic Discharge (ESD)...17 5.1. Test Equipment...17 5.2. Test Setup...17 5.3. Test Level...17 5.4. Test Procedure...18 5.5. Test Specification...18 5.6. Uncertainty...18 5.7. Test Result...18 6. Radiated Susceptibility (RS)...19 6.1. Test Equipment...19 6.2. Test Setup...19 6.3. Test Level...19 6.4. Test Procedure...20 6.5. Test Specification...20 6.6. Uncertainty...20 6.7. Test Result...20 7. Electrical Fast Transient/Burst (EFT/B)...21 7.1. Test Equipment...21 Page: 3 of 50

7.2. Test Setup...21 7.3. Test Level...22 7.4. Test Procedure...22 7.5. Test Specification...22 7.6. Uncertainty...22 7.7. Test Result...22 8. Surge...23 8.1. Test Equipment...23 8.2. Test Setup...23 8.3. Test Level...23 8.4. Test Procedure...24 8.5. Test Specification...24 8.6. Uncertainty...24 8.7. Test Result...24 9. Conducted Susceptibility (CS)...25 9.1. Test Equipment...25 9.2. Test Setup...25 9.3. Test Level...25 9.4. Test Procedure...26 9.5. Test Specification...26 9.6. Uncertainty...26 9.7. Test Result...26 10. Voltage Dips and Interruption...27 10.1. Test Equipment...27 10.2. Test Setup...27 10.3. Test Level...27 10.4. Test Procedure...28 10.5. Test Specification...28 10.6. Uncertainty...28 10.7. Test Result...28 11. EMC Reduction Method During Compliance Testing...29 12. Test Result...30 12.1. Test Data of Conducted Emission...31 12.2. Test Data of Radiated Emission...38 12.3. Test Data of Power Harmonics, Voltage Flucturation and Flicker...39 12.4. Test Data of Electrostatic Discharge...42 12.5. Test Data of Radiated Susceptibility...43 12.6. Test Data of Electrical Fast Transient...44 12.7. Test Data of Surge...45 12.8. Test Data of Conducted Susceptibility...46 12.9. Test Data of Voltage Dips and Interruption...47 Attachment 1: EUT Test Photographs Attachment 2: EUT Detailed Photographs Reference : Laboratory of License Page: 4 of 50

1. GENERAL INFORMATION 1.1. EUT Description Product Name Notebook Trade Name MSI Model No. MS-1719 EUT Working Voltage AC 230V/50Hz Frequency Range 2412-2472MHz, 5150-5350MHz and 5470-5725MHz Number of Channels 802.11b/g/n-20MHz/n-40MHz: 13, 802.11a/n-20MHz: 19 802.11n-40MHz: 4 Maximum Data Rate 802.11b: 11Mbps, 802.11a/g: 54Mbps, 802.11n: 300Mbps Channel Separation 802.11b/g/n-20MHz: 5 MHz, 802.11a/n-20MHz: 20MHz 802.11n-40MHz: 40MHz Type of Modulation DSSS/OFDM Channel Control Auto Antenna Gain Refer to the table Antenna List Antenna Type Connector Power Adapter LI SHIN, LSE0202C1990 Input: AC 100-240V, 50/60Hz, 1.5A Output: DC 19V, 4.74A Cable Out: Shielded, 1.8m, with one ferrite core bonded. Power Cord: Shielded, 1.8m Antenna List No. Manufacturer Part No. Peak Gain 1 HIGH-TEK S79-1800240-H39 (Main) S79-1800230-H39 (Aux) -0.10dBi for 2.4 GHz -1.79dBi for 5.0 GHz Page: 5 of 50

802.11b/g/n-20MHz Center Frequency of Each Channel: Channel Frequency Channel Frequency Channel Frequency Channel Frequency Channel 01: 2412 MHz Channel 02: 2417 MHz Channel 03: 2422 MHz Channel 04: 2427 MHz Channel 05: 2432 MHz Channel 06: 2437 MHz Channel 07: 2442 MHz Channel 08: 2447 MHz Channel 09: 2452 MHz Channel 10: 2457 MHz Channel 11: 2462 MHz Channel 12: 2467 MHz Channel 13: 2472 MHz 802.11a/n-20MHz Center Working Frequency of Each Channel: Channel Frequency Channel Frequency Channel Frequency Channel Frequency Channel 1: 5180 MHz Channel 2: 5200 MHz Channel 3: 5220 MHz Channel 4: 5240 MHz Channel 5: 5260 MHz Channel 6: 5280 MHz Channel 7: 5300 MHz Channel 8: 5320 MHz Channel 9: 5500 MHz Channel 10: 5520 MHz Channel 11: 5540 MHz Channel 12: 5560 MHz Channel 13: 5580 MHz Channel 14: 5600 MHz Channel 15: 5620 MHz Channel 16: 5640 MHz Channel 17: 5660 MHz Channel 18: 5680 MHz Channel 19: 5700 MHz 802.11n-40MHz Center Working Frequency of Each Channel: Channel Frequency Channel Frequency Channel Frequency Channel Frequency Channel 1: 5190 MHz Channel 2: 5310 MHz Channel 3: 5510 MHz Channel 4: 5670 MHz Note: 1. QuieTek verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: EMI Mode EMS Mode Mode 1: Normal Operation (4965AGN) Mode 1: Normal Operation (4965AGN) Page: 6 of 50

1.2. Tested System Details The types for all equipment, plus descriptions of all cables used in the tested system (including inserted cards) are: Product Manufacturer Model No. Serial No. Power Cord 1 Printer EPSON StyLus C63 FAPY093574 Non-Shielded, 1.9m 2 Monitor BenQ LT-20BW7BK N/A Non-Shielded, 1.8m 3 USB 2.0 HDD TeraSys F12-UF A0100215-64b0019 N/A 4 USB 2.0 HDD TeraSys F12-UF A0100215-64b0013 N/A 5 USB Mouse Logitech M-BE58 HCA30103299 N/A 6 Microphone & PCHOME N/A N/A N/A Earphone 7 Walkman AIWA HS-TA164 N/A N/A 8 Monitor SAMSUNG 1200NF 800083Z Non-Shielded, 1.8m 9 TS9980 R&S N/A N/A N/A 10 Notebook PC DELL PP18L 42649348672 Non-Shielded, 1.8m 11 Exchange Network Sun Moon Star PX-4 95170087 Non-Shielded, 1.8m Signal Cable Type Signal cable Description A USB Cable Shielded, 1.5m B HDMI Cable Shielded, 2.0m C USB Cable Shielded, 1.5m D 1394 Cable Shielded, 1.2m E USB Mouse Cable Shielded, 1.5m F Earphone & Microphone Cable Non-Shielded, 1.6m G Audio Cable Non-Shielded, 1.6m H D-SUB Cable Shielded, 1.8m, with two ferrite cores bonded I LAN Cable Non-Shielded, 4.0m J TELECOM Cable Non-Shielded, 2.0m K TELECOM Cable Non-Shielded, 2.0m L COAXIAL Cable Shielded, 7.0m Page: 7 of 50

1.3. Configuration of Test System 1.4. EUT Exercise Software (1) Setup the EUT and peripherals as shown in section 1.3. (2) Turn on the power of all equipments. (3) Boot the EUT. (4) The EUT reads test software from the hard disk. The EUT, the monitor, and the notebook will show the transmitting and receiving characteristics when (5) the communication is success. (6) The wireless LAN function is used to perform the wireless data transmission. (7) Repeat the step 5 and 6. Page: 8 of 50

1.5. Test Facility Ambient conditions in the laboratory: Items Test Item Required (IEC 68-1) Actual Temperature ( C) 15-35 20-35 Humidity (%RH) IEC 61000-4-2 30-60 50-55 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 20-35 Humidity (%RH) IEC 61000-4-5 10-75 50-65 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC 61000-4-4 15-35 20-35 Barometric pressure (mbar) IEC 61000-4-11 860-1060 950-1000 Site Description: Accredited by NVLAP NVLAP Lab Code: 200533-0 Site Name: Site Address: Accredited by DNV Statement No. : 413-99-LAB11 Accredited by Nemko Certificate No.: ELA 165 Accredited by TUV Rheinland Certificate No.: 10011438-1-2004 Accredited by CNLA Accredited Number: 0914 Quietek Corporation No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : service@quietek.com 0914 Page: 9 of 50

2. Conducted Emission 2.1. Test Equipmen The following test equipment are used during the conducted emission test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. Remark 1 Test Receiver R & S ESCS 30 / 825442/018 Sep., 2006 2 Artificial Mains Network R & S ENV4200 / 848411/10 Feb., 2007 Peripherals 3 LISN R & S ESH3-Z5 / 825562/002 Feb., 2007 EUT 4 Pulse Limiter R & S ESH3-Z2 / 357.8810.52 Feb., 2007 5 4-wire ISN R & S ENY41 / 837032/001 Feb., 2007 6 Double 2-Wire ISN R & S ENY22 / 835354/008 Feb., 2007 7 No.1 Shielded Room Note: All equipments are calibrated every one year. 2.2. Test Setup Shielded Room 0.8m Peripheral ( EUT ) 40cm 80cm AMN for Peripheral AMN for EUT 50 ohm Terminator Test Receiver Page: 10 of 50

2.3. Limits (1) Mains terminal Frequency MHz Limits (dbuv) Limit for conducted emissions of equipment intended to be used in Limit for conducted emissions telecommunication centers only QP AV QP AV 0.15-0.50 79 66 66-56 56-46 0.50-5.0 73 60 56 46 5.0-30 73 60 60 50 Remarks: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz ~ 0.50 MHz. (2) Telecommunication ports Limits (dbuv) Frequency MHz Limit for conducted emissions from telecommunication ports of equipment intended for use in telecommunication centers only Limit for conducted emissions from telecommunication ports QP AV QP AV 0.15 0.50 97-87 84-74 84-74 74-64 5.0 30 87 74 74 64 Remarks: In the above table, the tighter limit applies at the band edges. Page: 11 of 50

2.4. Test Procedure AC Mains: The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm /50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of AC line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ETSI EN 301489-1: V1.6.1 (2005-09) on conducted measurement. The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz. Telecommunication Port: The mains voltage shall be supplied to the EUT via the LISN when the measurement of telecommunication port is performed. The common mode disturbances at the telecommunication port shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB LCL is wed for alternative one. 2.5. Test Specification According to ETSI EN 301489-1: V1.6.1 (2005-09) EN 55022:1998+A1: 2000 +A2: 2003 2.6. Uncertainty ± 2.26 db 2.7. Test Result The emission from the EUT was below the specified limits. The worst-case emissions are shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 12 of 50

3. Radiated Emission 3.1. Test Equipment The following test equipment are used during the Radiated emission test: Test Site Equipment Manufacturer Model No./Serial No. Last Cal. Site # 1 Test Receiver R & S ESVS 10 / 834468/003 July, 2006 Spectrum Analyzer Advantest R3162/ 00803480 May, 2006 Pre-Amplifier Advantest BB525C/ 3307A01812 May, 2006 Bilog Antenna SCHAFFNER CBL6112B / 2697 Nov., 2006 Site # 2 Test Receiver R & S ESCS 30 / 836858 / 022 Nov., 2006 Spectrum Analyzer Advantest R3162 / 100803466 May, 2006 Pre-Amplifier Advantest BB525C/3307A01814 May, 2006 Bilog Antenna SCHAFFNER CBL6112B / 2705 Oct., 2006 Horn Antenna ETS 3115 / 0005-6160 July, 2006 Pre-Amplifier QTK QTK-AMP-01/ 0001 July, 2006 Site # 3 Test Receiver R & S ESI 26 / 838786 / 004 May, 2006 Spectrum Analyzer Advantest R3162 / 100803480 May, 2006 Pre-Amplifier QTK QTK-AMP-03 / 0003 May, 2006 Bilog Antenna SCHAFFNER CBL6112B / 2697 May, 2006 Horn Antenna ETS 3115 / 0005-6160 July, 2006 Pre-Amplifier QTK QTK-AMP-01 / 0001 July, 2006 Note: 1. All equipments are calibrated every one year. 2. The test instruments marked by X are used to measure the final test results. 3.2. Test Setup 10m FRP Dome 1m to 4m Non-Conducted Table Load EUT Antenna Mast Dipole or Horn Antenna Antenna height can be moved from 1m to 4m, Antenna and turntable distance 3m 80cm Test Receiver Fully Soldered Ground Plane TO Controller To Receiver Page: 13 of 50

3.3. Limits Limits (dbuv/m) Frequency MHz Limit for radiated emissions from ancillary equipment intended for use in telecommunication centers only, and measured on a stand alone basis QP Limit for radiated emissions from ancillary equipment, measured on a stand alone basis QP 30-230 40 30 230-1000 47 37 3.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 10 meters.the antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated according to ETSI EN 301489-1: V1.6.1 (2005-09) on radiated measurement. The additional motch filter below 1GHz was used to measure the level of harmonics radiated emission during field dtrength of harmonics measurement. The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30) is 120 khz, and 1MHz bandwidth is adpted above 1GHz. The frequency range from 30MHz to 10 th harmonics is checked. 3.5. Test Specification According to ETSI EN 301489-1: V1.6.1 (2005-09) EN 55022:1998+A1: 2002+A2: 2003 3.6. Uncertainty ± 3.8 db 3.7. Test Result The emission from the EUT was below the specified limits. The worst-case emissions are shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 14 of 50

4. Power Harmonics, Voltage Fluctuation and Flicker 4.1. Test Equipment Item Instrument 4Manufacturer Type No/Serial No. Last Calibration 1 Power Harmonics Tester SCHAFFNER Profline 2105-400 S/N: HK54148 June, 2006 2 Analyzer SCHAFFNER CCN 1000-1/X71887 June, 2006 3 No.3 Shielded Room Note: All equipments are calibrated every one year. 4.2. Test Setup Controller PC Power Analyzer Impedance Network Power Source EUT Load Non-Conducted 4.3. Limits Limits of Class A Harmonics Currents Harmonics Order n Maximum Permissible harmonic current A Odd harmonics Harmonics Order n Maximum Permissible harmonic current A Even harmonics 3 2.30 2 1.08 5 1.14 4 0.43 7 0.77 6 0.30 9 0.40 8 n 40 0.23 * 8/n 11 0.33 13 0.21 15 n 39 0.15 * 15/n Limits of Class B Harmonics Currents For Class B equipment, the harmonic of the input current shall not exceed the maximum permissible values given in table that is the limit of Class A multiplied by a factor of 1.5. Page: 15 of 50

Limits of Class C Harmonics Currents Report No. 071L112-RFCEP02V01-A Harmonics Order Maximum Permissible harmonic current Expressed as a percentage of the input current at the fundamental frequency n % 2 2 3 30.λ * 5 10 7 7 9 5 11 n 39 3 (odd harmonics only) *λ is the circuit power factor Limits of Class D Harmonics Currents Harmonics Order Maximum Permissible harmonic current per watt ma/w Maximum Permissible harmonic current A n 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33 13 n 39 (odd harmonics only) 4.4. Test Procedure 3.85/n See limit of Class A The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed. 4.5. Test Specification According to EN 61000-3-2:2000+A1: 2001, EN 61000-3-3:1995+A1: 2001 4.6. Uncertainty ± 3.23 % 4.7. Test Result The measurement of the power harmonics, which test at the extremes of EUT s supply range, was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Test Result: (See Test Result) PASS FAIL Note: According to clause 7 of EN 61000-3-2: 2000, equipment with a rated power of 75W or less, no limits apply. The test result is only for reference. Page: 16 of 50

5. Electrostatic Discharge (ESD) 5.1. Test Equipment Item Instrument Manufacturer Type No/Serial No. Last Calibration 1 ESD Simulator System SCHAFFNER NSG-438 S/N: 167 June, 2006 2 Horizontal Coupling Plane (HCP) 3 Vertical Coupling Plane (VCP) 4 No.3 Shielded Room QuieTek HCP AL50 N/A QuieTek VCP AL50 N/A Note: All equipments are calibrated every one year. 5.2. Test Setup Vertical Coupling Plane Insulation EUT Loads: Active Horizontal Coupling Plane 80cm Non-Conducted table ESD Simulator 470K ohm Resistor Metal Ground Plane 470K ohm Resistor 5.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Electrostatic Discharge kv(charge Voltage) ±8 Air Discharge ±4 Contact Discharge B Page: 17 of 50

5.4. Test Procedure Direct application of discharges to the EUT: Contact discharge was applied only to conductive surfaces of the EUT. Air discharges were applied only to non-conductive surfaces of the EUT. During the test, it was performed with single discharges. For the single discharge time between successive single discharges will be keep longer 1 second. It was at least ten single discharges with positive and negative at the same selected point. The selected point, which was performed with electrostatic discharge, was marked on the red label of the EUT. Indirect application of discharges to the EUT: Vertical Coupling Plane (VCP): The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. Horizontal Coupling Plane (HCP): The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. 5.5. Test Specification According to EN 61000-4-2:1995+A1: 1998+A2: 2001 5.6. Uncertainty ± 6.003 % 5.7. Test Result The measurement of the electrostatic discharge was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 18 of 50

6. Radiated Susceptibility (RS) 6.1. Test Equipment Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 Signal Generator R & S SMY02 / 825454/029 Oct., 2006 2 Power Amplifier A & R 100W10000M7 / A285000010 N/A 3 RF Power Amplifier OPHIRRF 5022F / 1075 N/A 4 Bilog Antenna Chase CBL6112B / 2452 Sep., 2006 5 Power Meter R & S NRVD / 100219 Jan., 2007 6 Directional Coupler A & R DC6180 / 22735 Jan., 2007 7 No.5 EMC Fully Chamber Note: All equipments are calibrated every one year. 6.2. Test Setup Antenna Mast 3 m Sensor Full-Anechoic Chamber Camera system EUT Load 1m 80cm Power Amplifier Field Meter Power Meter Signal Generator Computer controller Camera Monitor 6.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Radio-Frequency MHz 80-1000 1400-2000 Electromagnetic Field V/m(Un-modulated, rms) 3 A Amplitude Modulated % AM (1kHz) 80 Page: 19 of 50

6.4. Test Procedure The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with one coincident with the calibration plane such that the distance from antenna to the EUT was 3 meters. Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on measurement. In order to judge the EUT performance, a CCD camera is used to monitor EUT screen. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 3 V/m Level 2 2. Radiated Signal AM 80% Modulated with 1kHz sinusoidal audio signal 3. Scanning Frequency 80MHz - 1000MHz, 1400MHz - 2000MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 6.5. Test Specification According to EN 61000-4-3:1996+A1: 1998+A2: 2001 6.6. Uncertainty ± 6.17 % 6.7. Test Result The measurement of the radiated susceptibility was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 20 of 50

7. Electrical Fast Transient/Burst (EFT/B) 7.1. Test Equipment Item Instrument Manufacturer Type No/Serial No. Last Calibration Fast Transient/Burst 1 Generator 2 No.2 Shielded Room SCHAFFNER NSG 2050 S/N: 200124-031AR June, 2006 Note: All equipments are calibrated every one year. 7.2. Test Setup Page: 21 of 50

7.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria Ports for signal lines and control lines kv (Peak) +0.5 Fast Transients Common Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 Input DC Power Ports kv (Peak) +0.5 Fast Transients Common Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 Input AC Power Ports kv (Peak) +1 Fast Transients Common Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 7.4. Test Procedure The EUT and load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. For Signal Ports and Telecommunication Ports: The EFT interference signal is through a coupling clamp device couples to the signal and control lines of the EUT with burst noise for 1min. For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the EFT interference signal. Each of the Line and Neutral conductors is impressed with burst noise for 1 min. The length of power cord between the coupling device and the EUT shall be 1m. 7.5. Test Specification According to EN 61000-4-4:1995+A1: 2001+A2: 2001 7.6. Uncertainty ± 8.80 % 7.7. Test Result The measurement of the Electrical Fast Transient/Burst was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 22 of 50

8. Surge 8.1. Test Equipment Item Instrument Manufacturer Type No/Serial No. Last Calibration 1 Surge Generator SCHAFFNER NSG 2050 S/N: 200124-031AR 2 No.6 Shielded Room June, 2006 Note: All equipments are calibrated every one year. 8.2. Test Setup PC Surge Generator EUT Load Non-Conducted Table Non-Conducted Table 8.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria Telecommunication Ports (See 1) and 2)) Surges Tr/Th us Line to Ground kv Telecommunication Ports in Telecom Centres (See 1) and 2)) Surges Tr/Th us Line to Ground kv AC Input and AC Output Power Ports Surges Line to Line Line to Ground Tr/Th us kv kv AC Input and AC Output Power Ports in Telecom Centres Surges Tr/Th us Line to Line kv Line to Ground kv 1.2/50 (8/20) ± 1 1.2/50 (8/20) ± 0.5 1.2/50 (8/20) ±1 ± 2 1.2/50 (8/20) ±0.5 ± 1 B B B B Notes: 1) Applicable only to ports which according to the manufacturer s may directly to outdoor cables. 2) Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity test shall be required. Page: 23 of 50

8.4. Test Procedure The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The length of power cord between the coupling device and the EUT shall be 2m or less. For Signal Ports and Telecommunication Ports The disturbance signal is through a coupling and decoupling networks (CDN) device couples to the signal and Telecommunication lines of the EUT. For Input and Output AC Power or DC Input and DC Output Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the Surge interference signal. The surge noise shall be applied synchronized to the voltage phase at 0 0, 90 0, 180 0, 270 0 and the peak value of the a.c. voltage wave. (Positive and negative) Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with interval of 1 min. 8.5. Test Specification According to EN 61000-4-5:1995+A1+ 2001 8.6. Uncertainty ± 7.93 % 8.7. Test Result The measurement of the Surge was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 24 of 50

9. Conducted Susceptibility (CS) 9.1. Test Equipment Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 CS SYSTEM SCHAFFNER NSG 2070 March, 2007 2 CDN SCHAFFNER CDN M016S / 20822 Dec., 2006 3 CDN SCHAFFNER CDN M016S / 20823 Dec., 2006 4 FIXED PAD SCHAFFNER INA 2070-1 / 2115 N/A 5 EM Clamp KEMZ 801 / 21024 March, 2007 6 No.6 Shielded Room Note: All equipments are calibrated every one year. 9.2. Test Setup Aux equipment CDN EUT CDN Aux equipment Ground Reference Plane T Non-Conducted Table T2 RF-Generator PA 9.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria AC Input and AC Output & DC Input and DC output Power Ports & Functional Earth Ports Radio-Frequency Common Mode. Amplitude Modulated MHz V (rms, Unmodulated) % AM (1kHz) Source Impedance Ω 0.15-80 3 80 150 A Page: 25 of 50

9.4. Test Procedure The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. For Signal Ports and Telecommunication Ports The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp device couples to the signal and Telecommunication lines of the EUT. For Input DC and AC Power Ports The EUT is connected to the power mains through a coupling and decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. Used CDN-M2 for two wires or CDN-M3 for three wires. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 130dBuV(3V) Level 2 2. Radiated Signal AM 80% Modulated with 1kHz sinusoidal audio signal 3. Scanning Frequency 0.15MHz 80MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 9.5. Test Specification According to EN 61000-4-6:1996 +A1: 2001 9.6. Uncertainty ± 6.17 % 9.7. Test Result The measurement of the Conducted Susceptibility was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 26 of 50

10. Voltage Dips and Interruption 10.1. Test Equipment Item Instrument Manufacturer Type No/Serial No. Last Calibration 1 Voltage Dips Generator SCHAFFNER NSG 2050 S/N: 200124-031AR 2 No.6 Shielded Room June, 2006 Note: All equipments are calibrated every one year. 10.2. Test Setup To AC Line Voltage Dips/ Interruptions /Variations Simulator AC Power Line to EUT EUT Load Non-Conducted Table 80cm Controller Computer Printer 10.3. Test Level Item Environmental Phenomena Units Test Specification Performance Criteria AC Input and AC Output Power Ports Voltage Dips % Reduction ms 30 10 B Voltage Dips % Reduction ms 60 100 C Voltage Interruptions % Reduction ms > 95 % 5000 C Page: 27 of 50

10.4. Test Procedure The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used the shortest power cord as specified by the manufacturer. For Voltage Dips/ Interruptions test: The selection of test voltage is based on the rated power range. If the operation range is large than 20% of lower power range, both end of specified voltage shall be tested. Otherwise, the typical voltage specification is selected as test voltage. The EUT is connected to the power mains through a coupling device that directly couples to the Voltage Dips and Interruption Generator. The EUT shall be tested for 30% voltage dip of supplied voltage and duration 10ms, with a sequence of three voltage dips with intervals of 10 seconds, for 60% voltage dip of supplied voltage and duration 100ms with a sequence of three voltage dips with intervals of 10 seconds, and for 95% voltage interruption of supplied voltage and duration 5000ms with a sequence of three voltage interruptions with intervals of 10 seconds. Voltage phase shifting are shall occur at 0 0, 45 0, 90 0,135 0,180 0,225 0, 270 0,315 0 of the voltage. 10.5. Test Specification According to EN 61000-4-11:1994+A1: 2001 10.6. Uncertainty ± 2.03 % 10.7. Test Result The measurement of the Voltage Dips and Interruption was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test. Page: 28 of 50

11. EMC Reduction Method During Compliance Testing No modification was made during testing. Page: 29 of 50

12. Test Result The test results in the emission and the immunity were performed according to the requirements of measurement standard and process. Quietek Corporation is assumed full responsibility for the accuracy and completeness of these measurements. The test data of the emission is listed as below. All the tests were carried out with the EUT in normal operation, which was defined as: EMI Mode EMS Mode Mode 1: Normal Operation (4965AGN) Mode 1: Normal Operation (4965AGN) Page: 30 of 50

12.1. Test Data of Conducted Emission Product : Notebook Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 1 Test Mode : Mode 1: Normal Operation (4965AGN) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv LINE 1 Quasi-Peak 0.189 0.202 54.000 54.202-10.684 64.886 0.252 0.204 50.720 50.924-12.162 63.086 0.502 0.216 42.410 42.626-13.374 56.000 0.880 0.231 41.180 41.411-14.589 56.000 3.459 0.329 40.690 41.019-14.981 56.000 3.709 0.339 42.150 42.489-13.511 56.000 Average 0.189 0.202 51.640 51.842-3.044 54.886 0.252 0.204 47.400 47.604-5.482 53.086 0.502 0.216 39.410 39.626-6.374 46.000 0.880 0.231 41.080 41.311-4.689 46.000 3.459 0.329 38.610 38.939-7.061 46.000 3.709 0.339 41.470 41.809-4.191 46.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 31 of 50

Product : Notebook Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 2 Test Mode : Mode 1: Normal Operation (4965AGN) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv LINE 2 Quasi-Peak 0.189 0.202 49.830 50.032-14.854 64.886 0.257 0.203 43.600 43.803-19.140 62.943 0.375 0.214 32.680 32.894-26.677 59.571 1.701 0.262 37.060 37.322-18.678 56.000 2.646 0.305 35.600 35.905-20.095 56.000 11.787 0.627 30.530 31.157-28.843 60.000 Average 0.189 0.202 46.720 46.922-7.964 54.886 0.257 0.203 35.710 35.913-17.030 52.943 0.375 0.214 29.620 29.834-19.737 49.571 1.701 0.262 37.050 37.312-8.688 46.000 2.646 0.305 35.540 35.845-10.155 46.000 11.787 0.627 27.050 27.677-22.323 50.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 32 of 50

Product : Notebook Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) (GIGA Voltage) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv Quasi-Peak 0.283 20.103 41.260 61.363-18.837 80.200 0.564 20.107 33.910 54.017-19.983 74.000 0.685 20.109 35.910 56.019-17.981 74.000 1.189 20.116 27.680 47.796-26.204 74.000 2.451 20.132 29.200 49.332-24.668 74.000 16.297 20.317 36.660 56.977-17.023 74.000 Average 0.283 20.103 41.250 61.353-8.847 70.200 0.564 20.107 30.830 50.937-13.063 64.000 0.685 20.109 28.210 48.319-15.681 64.000 1.189 20.116 22.160 42.276-21.724 64.000 2.451 20.132 27.600 47.732-16.268 64.000 16.297 20.317 28.520 48.837-15.163 64.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 33 of 50

Product : Notebook Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) (GIGA Current) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv Quasi-Peak 0.185 0.102 10.890 10.992-28.008 39.000 0.795 0.110 10.270 10.380-19.620 30.000 9.658 0.229 8.200 8.429-21.571 30.000 11.295 0.250 8.290 8.540-21.460 30.000 13.416 0.279 8.190 8.469-21.531 30.000 18.662 0.349 8.940 9.289-20.711 30.000 Average 0.185 0.102 10.170 10.272-18.728 29.000 0.795 0.110 7.870 7.980-12.020 20.000 9.658 0.229 3.090 3.319-16.681 20.000 11.295 0.250 3.190 3.440-16.560 20.000 13.416 0.279 3.310 3.589-16.411 20.000 18.662 0.349 3.960 4.309-15.691 20.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 34 of 50

Product : Notebook Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) (ISN-100Mbps) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv Quasi-Peak 5.236 9.770 50.200 59.970-14.030 74.000 10.244 9.816 53.750 63.566-20.434 84.000 11.892 9.828 55.510 65.338-18.662 84.000 13.357 9.838 58.240 68.078-15.922 84.000 16.228 9.856 62.420 72.276-11.724 84.000 17.693 9.866 60.460 70.326-13.674 84.000 Average 5.236 9.770 47.840 57.610-6.390 64.000 10.244 9.816 51.860 61.676-12.324 74.000 11.892 9.828 53.480 63.308-10.692 74.000 13.357 9.838 56.120 65.958-8.042 74.000 16.228 9.856 60.180 70.036-3.964 74.000 17.693 9.866 58.250 68.116-5.884 74.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 35 of 50

Product : Notebook Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) (ISN-10Mbps) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv Quasi-Peak 0.283 9.793 48.040 57.833-22.367 80.200 0.360 9.784 44.370 54.154-23.846 78.000 5.048 9.767 44.200 53.967-20.033 74.000 8.517 9.803 44.920 54.723-29.277 84.000 10.009 9.813 61.550 71.363-12.637 84.000 15.025 9.840 45.140 54.980-29.020 84.000 Average 0.283 9.793 37.267 47.060-23.140 70.200 0.360 9.784 43.120 52.904-15.096 68.000 5.048 9.767 23.120 32.887-31.113 64.000 8.517 9.803 23.850 33.653-40.347 74.000 10.009 9.813 41.920 51.733-22.267 74.000 15.025 9.840 25.730 35.570-38.430 74.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 36 of 50

Product : Notebook Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) (Telecom) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv db dbuv Quasi-Peak 0.287 9.794 41.490 51.284-28.802 80.086 0.564 9.767 39.710 49.477-24.523 74.000 1.134 9.735 40.770 50.505-23.495 74.000 3.650 9.758 40.100 49.858-24.142 74.000 6.033 9.780 35.750 45.530-28.470 74.000 7.338 9.788 35.440 45.228-28.772 74.000 Average 0.287 9.794 40.690 50.484-19.602 70.086 0.564 9.767 37.070 46.837-17.163 64.000 1.134 9.735 38.410 48.145-15.855 64.000 3.650 9.758 35.460 45.218-18.782 64.000 6.033 9.780 28.840 38.620-25.380 64.000 7.338 9.788 28.200 37.988-26.012 64.000 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 37 of 50

12.2. Test Data of Radiated Emission Product : Notebook Test Item : General Radiated Emission Test Site : No.3 OATS Test Mode : Mode 1: Normal Operation (4965AGN) Frequency Correct Reading Measurement Margin Limit Factor Level Level MHz db dbuv dbuv/m db dbuv/m Horizontal 150.820 11.559 11.980 23.538-6.462 30.000 240.000 11.949 14.110 26.059-10.941 37.000 312.000 13.768 8.350 22.118-14.882 37.000 480.110 18.760 11.610 30.370-6.630 37.000 720.166 20.873 7.210 28.083-8.917 37.000 960.000 22.907 5.310 28.216-8.784 37.000 Vertical 150.830 10.408 12.940 23.348-6.652 30.000 192.000 9.381 11.810 21.191-8.809 30.000 240.000 12.342 15.000 27.342-9.658 37.000 319.490 14.191 6.770 20.961-16.039 37.000 480.000 18.475 7.100 25.575-11.425 37.000 700.000 20.666 1.240 21.906-15.094 37.000 Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 38 of 50

12.3. Test Data of Power Harmonics, Voltage Flucturation and Flicker Product : Notebook Test Item : Power Harmonics Classification : Class D Test Mode : Mode 1: Normal Operation (4965AGN) Test Result: Pass Source qualification: Normal Current & voltage waveforms 0.9 300 Current (Amps) 0.6 0.3 0.0-0.3-0.6 200 100 0-100 -200 Voltage (Volts) -0.9-300 Harmonics and Class D limit line European Limits Current RMS(Amps) 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 4 8 12 16 20 24 28 32 36 40 Harmonic # Test result: Pass Worst harmonic was #15 with 15.21% of the limit. Page: 39 of 50

Test Result: Pass Source qualification: Normal THC(A): 0.05 I-THD(%): 13.52 POHC(A): 0.005 POHC Limit(A): 0.038 Highest parameter values during test: V_RMS (Volts): 229.81 Frequency(Hz): 50.00 I_Peak (Amps): 0.734 I_RMS (Amps): 0.401 I_Fund (Amps): 0.382 Crest Factor: 1.965 Power (Watts): 89.1 Power Factor: 0.967 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.044 0.303 14.4 0.046 0.454 10.13 Pass 4 0.000 5 0.007 0.169 3.9 0.008 0.254 2.86 Pass 6 0.000 7 0.008 0.089 9.1 0.008 0.134 6.21 Pass 8 0.000 9 0.006 0.045 14.2 0.007 0.067 10.22 Pass 10 0.000 11 0.005 0.031 15.7 0.005 0.047 10.82 Pass 12 0.000 13 0.005 0.027 16.9 0.006 0.040 14.81 Pass 14 0.000 15 0.004 0.023 16.0 0.005 0.034 15.21 Pass 16 0.000 17 0.003 0.020 13.3 0.004 0.030 12.11 Pass 18 0.000 19 0.002 0.018 11.1 0.002 0.027 8.29 Pass 20 0.000 21 0.002 0.016 11.0 0.002 0.025 7.82 Pass 22 0.000 23 0.002 0.015 10.9 0.002 0.022 8.55 Pass 24 0.000 25 0.001 0.014 10.6 0.002 0.021 8.73 Pass 26 0.000 27 0.001 0.013 10.7 0.002 0.019 8.10 Pass 28 0.000 29 0.001 0.012 12.2 0.002 0.018 10.56 Pass 30 0.000 31 0.002 0.011 14.5 0.002 0.017 11.78 Pass 32 0.000 33 0.002 0.010 15.1 0.002 0.016 12.10 Pass 34 0.000 35 0.002 0.010 15.6 0.002 0.015 12.20 Pass 36 0.000 37 0.001 0.009 16.1 0.002 0.014 11.79 Pass 38 0.001 39 0.001 0.009 16.2 0.002 0.013 11.93 Pass 40 0.001 1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. 2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W. Others the result should be pass. Page: 40 of 50

Product : Notebook Test Item : Voltage Fluctuations and Flicker Test Mode : Mode 1: Normal Operation (4965AGN) Test Result: Pass Status: Test Completed Pst i and limit line European Limits 1.00 0.75 Pst 0.50 0.25 5:31:15 Plt and limit line Plt 0.6 0.5 0.4 0.3 0.2 0.1 5:31:15 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.77 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass Page: 41 of 50

12.4. Test Data of Electrostatic Discharge Product : Notebook Test Item : Electrostatic Discharge Test Site : No.3 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) Item Amount of Discharge Voltage Required Criteria Complied To Criteria (A, B, C) Results Air Discharge 10 10 +8kV -8kV B B B B Pass Pass Contact Discharge 25 25 +4kV -4kV B B B B Pass Pass Indirect Discharge 50 +4kV B B Pass (HCP) 50-4kV B B Pass Indirect Discharge 50 +4kV B B Pass (VCP Front) 50-4kV B B Pass Indirect Discharge 50 +4kV B B Pass (VCP Left) 50-4kV B B Pass Indirect Discharge 50 +4kV B B Pass (VCP Back) 50-4kV B B Pass Indirect Discharge 50 +4kV B B Pass (VCP Right) 50-4kV B B Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. NR: No Requirement Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. Page: 42 of 50

12.5. Test Data of Radiated Susceptibility Product : Notebook Test Item : Radiated Susceptibility Test Site : No.5 EMC fully Chamber Test Mode : Mode 1: Normal Operation (4965AGN) Frequency (MHz) Position (Angle) Polarity (H or V) Field Strength (V/m) Required Criteria Complied To Criteria (A, B, C) Results 80-1000 Front H 3 A A Pass 80-1000 Front V 3 A A Pass 80-1000 Back H 3 A A Pass 80-1000 Back V 3 A A Pass 80-1000 Left H 3 A A Pass 80-1000 Left V 3 A A Pass 80-1000 Right H 3 A A Pass 80-1000 Right V 3 A A Pass 80-1000 Top H 3 A A Pass 80-1000 Top V 3 A A Pass 80-1000 Down H 3 A A Pass 80-1000 Down V 3 A A Pass 1400-2000 Front H 3 A A Pass 1400-2000 Front V 3 A A Pass 1400-2000 Back H 3 A A Pass 1400-2000 Back V 3 A A Pass 1400-2000 Left H 3 A A Pass 1400-2000 Left V 3 A A Pass 1400-2000 Right H 3 A A Pass 1400-2000 Right V 3 A A Pass 1400-2000 Top H 3 A A Pass 1400-2000 Top V 3 A A Pass 1400-2000 Down H 3 A A Pass 1400-2000 Down V 3 A A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at at frequency MHz. No false alarms or other malfunctions were observed during or after the test. V/m Page: 43 of 50

12.6. Test Data of Electrical Fast Transient Product : Notebook Test Item : Electrical Fast Transient Test Site : No.2 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) Inject Line Polarity Voltage (kv) Inject Time (Second) Inject Method Required Criteria Complied to Criteria Result L + N +PE ± 1 60 CDN B A Pass LAN ± 0.5 90 Clamp B A Pass Telecom ± 0.5 90 Clamp B A Pass Coaxial ± 0.5 90 Clamp B A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at Line. No false alarms or other malfunctions were observed during or after the test. kv of Page: 44 of 50

12.7. Test Data of Surge Product : Notebook Test Item : Surge Test Site : No. 6 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) Inject Line Polarity Angle Voltage (kv) Time Interval (Second) Inject Method Required Criteria Complied to Criteria Result L-N ± 0 1 60 Direct B A Pass L-N ± 90 1 60 Direct B A Pass L-N ± 180 1 60 Direct B A Pass L-N ± 270 1 60 Direct B A Pass N-PE ± 0 2 60 Direct B A Pass N-PE ± 90 2 60 Direct B A Pass N-PE ± 180 2 60 Direct B A Pass N-PE ± 270 2 60 Direct B A Pass L+PE ± 0 2 60 Direct B A Pass L+PE ± 90 2 60 Direct B A Pass L+PE ± 180 2 60 Direct B A Pass L+PE ± 270 2 60 Direct B A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at Line. No false alarms or other malfunctions were observed during or after the test. kv of Page: 45 of 50

12.8. Test Data of Conducted Susceptibility Product : Notebook Test Item : Conducted Susceptibility Test Site : No. 6 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) Frequency Voltage Inject Tested Port of Required Performance Result Range Applied Method EUT Criteria Criteria (MHz) dbuv(v) Complied To 0.15~80 130(3V) CDN AC IN A A PASS 0.15~80 130(3V) CDN LAN A A PASS 0.15~80 130(3V) CDN LAN (GIGA) A A PASS 0.15~80 130(3V) CDN Telecom A A PASS 0.15~80 130(3V) CDN Coaxial A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 46 of 50

12.9. Test Data of Voltage Dips and Interruption Product : Notebook Test Item : Voltage Dips and Interruption Test Site : No.6 Shielded Room Test Mode : Mode 1: Normal Operation (4965AGN) Voltage Dips and Interruption Reduction (%) Angle Test Duration (ms) Required Performance Criteria Performance Criteria Complied To Test Result 30 0 10 B A PASS 30 45 10 B A PASS 30 90 10 B A PASS 30 135 10 B A PASS 30 180 10 B A PASS 30 225 10 B A PASS 30 270 10 B A PASS 30 315 10 B A PASS 60 0 100 B A PASS 60 45 100 B A PASS 60 90 100 B A PASS 60 135 100 B A PASS 60 180 100 B A PASS 60 225 100 B A PASS 60 270 100 B A PASS 60 315 100 B A PASS >95 0 5000 C A PASS >95 45 5000 C A PASS >95 90 5000 C A PASS >95 135 5000 C A PASS >95 180 5000 C A PASS >95 225 5000 C A PASS >95 270 5000 C A PASS >95 315 5000 C A PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 47 of 50

Attachment 1: EUT Test Photographs Page: 48 of 50

Report No.: 071L112-RFCEP02V01-A Attachment 1: EUT Test Setup Photographs Front View of Conducted Test Back View of Conducted Test Page : 1 of 10

Report No.: 071L112-RFCEP02V01-A Front View of Conducted Test (ISN) - GIGA VOL Back View of Conducted Test (ISN) - GIGA VOL Page : 2 of 10

Report No.: 071L112-RFCEP02V01-A Front View of Conducted Test (ISN) - GIGA CUR Back View of Conducted Test (ISN) - GIGA CUR Page : 3 of 10

Report No.: 071L112-RFCEP02V01-A Front View of Conducted Test (ISN) Back View of Conducted Test (ISN) Page : 4 of 10

Report No.: 071L112-RFCEP02V01-A Front View of Radiated Test Back View of Radiated Test-Clamp Page : 5 of 10

Report No.: 071L112-RFCEP02V01-A Power Harmonics Test Setup ESD Test Setup Page : 6 of 10

Report No.: 071L112-RFCEP02V01-A Radiated Susceptibility Test Setup EFT/B Test Setup Page : 7 of 10

Report No.: 071L112-RFCEP02V01-A EFT/B Test Setup Clamp SURGE Test Setup Page : 8 of 10

Report No.: 071L112-RFCEP02V01-A Conducted Susceptibility Test Setup Conducted Susceptibility Test Setup- CDN Page : 9 of 10

Report No.: 071L112-RFCEP02V01-A Voltage Dips Test Setup Page : 10 of 10

Attachment 2: EUT Detailed Photographs Page: 49 of 50

Report No.: 071L112-RFCEP02V01-A 附件 2: 待測物內部相片 (1) EUT Photo (2) EUT Photo Page : 1 of 12

Report No.: 071L112-RFCEP02V01-A (3) EUT Photo (4) EUT Photo Page : 2 of 12

Report No.: 071L112-RFCEP02V01-A (5) EUT Photo (6) EUT Photo Page : 3 of 12

Report No.: 071L112-RFCEP02V01-A (7) EUT Photo (8) EUT Photo Page : 4 of 12

Report No.: 071L112-RFCEP02V01-A (9) EUT Photo (10) EUT Photo Page : 5 of 12

Report No.: 071L112-RFCEP02V01-A (11) EUT Photo (12) EUT Photo Page : 6 of 12

Report No.: 071L112-RFCEP02V01-A (13) EUT Photo (14) EUT Photo Page : 7 of 12

Report No.: 071L112-RFCEP02V01-A (15) EUT Photo (16) EUT Photo Page : 8 of 12

Report No.: 071L112-RFCEP02V01-A (17) EUT Photo (18) EUT Photo Page : 9 of 12

Report No.: 071L112-RFCEP02V01-A (19) EUT Photo (20) EUT Photo Page : 10 of 12

Report No.: 071L112-RFCEP02V01-A (21) EUT Photo (22) EUT Photo Page : 11 of 12

Report No.: 071L112-RFCEP02V01-A (23) EUT Photo (24) EUT Photo Page : 12 of 12

Report No.: 071L112-RFCEP02V01-A (25) EUT Photo (26) EUT Photo Page : 13 of 12

Reference: Laboratory of License Page: 50 of 50