Inductive Proximity Detectors Technical Guide

Similar documents
Order/Technical Support Tel: (800) / FAX: (800) /

PROXIMITY SENSOR TERMINOLOGY

Proximity Sensor Terminology

Limit Switch Style Inductive Prox

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Induct. Inductive proximity sensors. Inductive sensors. Double sensing range. Triple sensing range. Single sensing range. Flush installation

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Inductive Proximity Sensor

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Inductive proximity switches IFL

Inductive sensor BI2-Q4,7-AN6X

Exercise 7. Inductive Proximity Switches EXERCISE OBJECTIVE

Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

FOR RELIABLY MEASURING +

PROXIMITY SENSORS report the LOCATION of an important item that must be monitored. Whether the DOOR is open or closed, the FLOW on or off, the LEVEL

E2B PROXIMITY SENSORS

Magnetoinductive SMARTSENS BIL. Magneto-inductive. Position Sensors Contents

Inductive Analog-Sensors

Analog Sensors Selection Guide

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Inductive sensor slot-type SI2-K08-AP7

More Precision. mainsensor // Magneto-inductive displacement sensors

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Rectangular Type APS-S/M Series

3mm - 6.5mm Inductives

Fluoro plastic housing for highest chemical and detergent resistance

Inductive BEROs. 5/2 Summary of ranges. 5/6 Introduction. 5/20 Operating distance 0.6 mm. 5/20 Operating distance 0.8 mm. 5/22 Operating distance 1 mm

I Kanson Electronics, Inc.

EE-SPX303/403. Ordering Information. Large Slot Width (13 mm) Not Influenced by External Light. H Easy adjustment and optical axis monitoring

Distance-setting Photoelectric Sensor

Ultraminiature Photoelectric Switches with Self-contained Amplifier

E2S World's Smallest Square Sensor with Built-in Amplifier

1. Position detection on a spindle drive unit by means of a linear potentiometer

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Express Delivery. Axial. Connection

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Heat Exchanger & Boiler Tube Inspection Techniques

E L E V A T O R S ELEVATORS Impaginato_2009_UK.indd :34:14

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

M5x0.5. M5x0.5 LED LED. Switching Distance Sn:mm 1mm 1mm 2mm 4mm LED Indicator Operating Voltage

5. Transducers Definition and General Concept of Transducer Classification of Transducers

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Capacitive Proximity Sensor

Proximity sensors. Inductive. Connection. magnetic. Festo Didactic Training and Consulting Sensors

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Magnetically Actuated Linear Position Sensor WIM100-Q25L-LIU5X2-H1141

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Distance-setting Photoelectric Sensor

SENSORS S62 SERIES. Telephone: Visit Our Website: us: DISTRIBUTED & SUPPORTED by:

MIG Encoders BEGE MIG NOVA+ Your drive, our (trans)mission. BEGE Power Transmission

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS.

Inductive linear position sensor LI400P0-Q25LM0-LIU5X3-H1151

Inductive, Photoelectric, Ultrasonic and Capacitive Proximity Switches

EE-SPY311/411/312/412

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Speed sensors for general applications:

Cylindrical Photoelectric Sensor

SENSORS S2Z SERIES MAXI SENSORS CARATTERISTICHE APPLICATIONS HIGHLIGHTS

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

USER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Inductive, Photoelectric and Ultrasonic Proximity Switches

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Industry's standard of transparent object detection sensor

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Cubic capacitive Sensor CQ55. Proximity Sensors

EE-SPY311/411/312/412

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Inductive Angle Sensor With Analog Output RI360P1-QR14-ELIU5X2

SALES SERVICE +358 (0)

Cubic capacitive Sensor CQ50. Proximity Sensors

Cylindrical Photoelectric Sensor. 6. Connection F Sensing Distance. 100: 100 mm. 300: 300 mm 2M: 2 Meters 5M: 5 Meters. 5. Output NPN - NO, NC

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Screw jack options. When stainless steel screws are specified, we can supply the flange end and rod end in stainless if requested.

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Capacitive BEROs. 6/2 Introduction. 6/4 DC 10 to 65 V. 6/6 AC 20 to 250 V

Lexium integrated drives

NCS3 Series Isolated 3W 4:1 Input Single Output DC-DC Converters

Inductive switches. Dimensioned drawing

Aluminum Electrolytic Capacitors Axial High Temperature, High Ripple Current

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects

Telemetrie-Messtechnik Schnorrenberg

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

KFS. Flap-type flow meter. Design and range of application

Technical Guide Proximity Sensors

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

Type matrix of inductive sensors

Easy to replace. A pigtailed type sensor with connector (CY- -J), which is easy to replace, is also available. Environment resistant

Cylindrical type proximity sensor

Transcription:

Operating principles Figure 1 illustrates the principle of an Inductive Proximity Detector (I.P.D.) M Method of measuring sensing distances: according to standard EN 50010. Lateral approach and axial approach: Axial approach : target centred on reference axis Target S Oscillator O D V Pulse shaper Amplifier The I.P.D. signals the presence of a object "M" close to its sensing face. It contains a high-frequency oscillator "O" whose oscillating circuit coil "S", located in a magnetic ferrite open on one side, forms the sensing face. An alternating magnetic field is created in front of this. On entering this field, any part "M" causes eddy currents, thus reducing the amplitude of oscillation. This reduced amplitude is converted by the pulse shaper "D" into an output signal amplified by "V". H Lateral approach : target perpendicular to reference axis B A H Detector Actual sensing distance Sensing face Operating characteristics: Sensing distance S: Distance at which the target determines a change in the status of the output signal, as it approaches the sensing face. Nominal sensing distance Sn: Conventional value used to describe the device. Does not take account of dispersion (due to manufacturing, temperature, voltage). Actual sensing distance Sr: Actual value measured from constant parameters (temperature, voltage, installation conditions etc), which must be between 90 and 110 % of the nominal sensing distance Sn. 0.9 Sn < Sr < 1.1 Sn Usable sensing distance Su: Value measured within the specified limits of the temperature and voltage zones, which must be between 81% and 121% of the nominal sensing distance Sn. 0.81 Sn < Su < 1.21 Sn Operating sensing distance Sa: Distance within which the detector will operate correctly in specified conditions. 0 < Sa < 0.81 Sn Repeatability R: Value of variation in the actual sensing distance Sr in specified conditions (time, temperature, voltage). Differential travel H: Distance between the pick-up point when the target approaches the detector and the drop-out point when the target moves away. Target Electrical characteristics: Normally open function (NO): Corresponds to a detector whose output allows the current to pass through when the target is detected. Normally closed function (NC): Corresponds to a detector whose output blocks the current when the target is detected. Equivalent circuit diagram NO NC Voltage drop Ud: Voltage measured across the active output of the detector in closed state under its nominal operating current (load current Ia). current Ia: Maximum current with which the detector permanently operates correctly. Leakage current Ir: Current which continues to circulate in the load and in the output circuit when the detector is in the open state. Minimum operating current Im: Current necessary to maintain conduction of the switching element. Time delay before availability Tv: Time necessary for the sensor output signal to operate when powering up. Un Supply voltage Tv Detector status accepted Su max. Sr max. Sn Sr min. Su min. ON OFF Su max. + H Sr max. + H Sn + H Sr min. + H Su min. + H Switching frequency F: Number of operating cycles carried out during a specified time. It is measured according to the method shown below (Standard EN 50010 NFC 6075). m : width of the target. m 2m Detector 0.5x Sn Measuring plate Sa Guaranteed operation Sensing face Proximity detector m Rotation Disc Operating voltage Un: Voltage range within which the detector maintains its specified characteristics. Ripple voltage: Ratio between the amplitude of an alternating voltage (peak to peak) and the direct voltage on which it is superimposed. /115

Detection characteristic curves - cylindrical CENELEC types Screened versions Non-screened versions - Approach detection curve - - Withdrawal detection curve (side detection) Sn Nominal sensing distance - Approach detection curve - - Withdrawal detection curve (side detection) Sn Nominal sensing distance SCREENED IPD Dimensions (mm) Nominal Ø mm of sensed plate sensing distance of A7 steel Sn (mm) Ø4 5 x 5 x 1 0...0.8 M5 5 x 5 x 1 0...0.8 Ø6.5 8 x 8 x 1 0...1.5 M8 8 x 8 x 1 0...1.5 M8 ext 8 x 8 x 1 0... M12 12 x 12 x 1 0...2 M12 ext 12 x 12 x 1 0...6 M18 18 x 18 x 1 0...5 M18 ext 18 x 18 x 1 0...12 M0 0 x 0 x 1 0...10 NON-SCREENED IPD Dimensions (mm) Nominal Ø mm of sensed plate sensing distance of A7 steel Sn (mm) Ø6.5 8 x 8 x 1 0...2.5 M8 8 x 8 x 1 0...2.5 M12 12 x 12 x 1 0...4 M18 18 x 18 x 1 0...8 M0 0 x 0 x 1 0...15 Notes When materials other than steel are detected, the following correction factors must be applied : Material Correction factor A7 mild steel 1 16 stainless steel 0.85 Brass 0.40 Aluminium 0.5 Copper 0.0 /116

Electrical connection PNP version -wire DC Brown Polarity reversible 2-wire AC (4) NO (2) NC black cable (NO or NC) 2 blue brown blue load PNP output: load connected to negative supply 1 NPN version brown Earth wire only available in housings (4) NO (2) NC black cable (NO or NC) blue NPN output: load connected to positive supply Installation "Screened" sensors can be inset in surrounding rising flush with the sensing face. With "non-screened" versions, check that there is no in the immediate vicinity of the sensing face. European standards define the minimum distance which must be allowed between two sensors and/or between sensors and surrounding articles so that the sensors will not be affected. The figures given below (which are in line with European standards) are for mounting in mild steel (A 7) with non-restrictive operating conditions. Where there are multiple constraints (deposits, temperature, etc) additional correcting factors will need to be applied. Screened Non-screened free zone Sn target Sn 2 Sn free zone target sensor d1 sensor 2 d1 d1 2 Sn The sensing face of the sensor must not be positioned below the surface of the. Sn: Nominal sensing distance d1: diameter of IPD Where two sensors are installed facing one another, a gap of 10 x Sn must be left between the two sensing faces. /117

Mechanical installation advice Protection: Protect the cable against sharp objects or excessive heat. Do not exert a pulling force of more than 5 kg on the cable. The detectors are unable to withstand severe mechanical impact. The bracket must be sufficiently rigid to resist shock and vibration. Avoid using the detectors in a corrosive environment such as near strong acids, etc. (e.g. Nitric Acid). When a plastic detector is used in a chemical environment it is advisable to first verify the plastic's resistance to the chemical. Electrical installation advice Power supply: Power source Connection: C + - Opposite is an example of a DC power supply for detectors using smoothing. To ensure that the resulting voltage is less than the maximum operating voltage of the detector, use a capacitor "C" to remove spikes and ripples greater than ± 10 %. Ideally, use a transformer with a secondary voltage less than your required voltage. Eg. 17.5 VAC from the secondary of the transformer to obtain less than 24 VDC. Metal conduit Power cable Connecting more than one sensor: Series installation: a (-) Limit the length of the cables to 100 m and the capacitance of the line to 0.1 µf. Also separate detector cables and power cables as far as possible. 2-wire detectors AC or DC It is possible to connect detectors in series: a (-) - Ensure that the voltage at the terminals of each sensor is less than or equal to the minimum operating voltage (in off-state). - In on-state, check that there is sufficient voltage available to activate the load. This connection method is not possible if multivoltage sensors are used. -wire DC detectors Detector 2 With this connection method, add the voltage drop of each detector together and deduct from the supply voltage to ensure there is sufficient voltage to activate the load. Note: detector 1 carries all the current for the additional detectors. (-) /118

Parallel installation: a 2-wire AC detectors With this type of installation the sum of the off-state leakage currents must be less than the current needed to drive the load. Note: this installation should only be used with detectors which are activated one at a time. a -wire DC detectors It is possible to connect -wire detectors in this configuration without any problems. (-) Examples of applications Part positioning Parts recognition - Metal detection /119

Examples of applications Detection of broken drill Control of robot grip Rotation control Screw detection /120