A realistic environmental approach for the construction of a perceptual typology of industrial noise sources

Similar documents
Please refer to the figure on the following page which shows the relationship between sound fields.

Environmental Noise Propagation

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

Field noise measurement in the huge industrial plants for accurate prediction

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation

An experimental evaluation of a new approach to aircraft noise modelling

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Protocol for Ambient Level Noise Monitoring

ISO INTERNATIONAL STANDARD

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE

ACOUSTIC SIGNATURE OF OPEN CUT COAL MINES

METHODOLOGY FOR VERIFICATION OF SOFTWARE FOR NOISE ATTENUATION CALCULATION ACCORDING TO ISO STANDARD

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

Investigation of Noise Spectrum Characteristics for an Evaluation of Railway Noise Barriers

WITHIN GENERATOR APPLICATIONS

CHAPTER 3 NOISE FUNDAMENTALS

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

Xtratherm Limited Kells Road, Navan, Co Meath

A SYSTEM IMPLEMENTATION OF AN ACTIVE NOISE CONTROL SYSTEM COMBINED WITH PASSIVE SILENCERS FOR IMPROVED NOISE REDUCTION IN DUCTS SUMMARY INTRODUCTION

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Assessment of rail noise based on generic shape of the pass-by time history

Validation of lateral fraction results in room acoustic measurements

Performance of Roadside Sound Barriers with Sound Absorbing Edges

Validation and evolution of the road traffic noise prediction model NMPB-96 - Part 1: Comparison between calculation and measurement results

HARMONOISE: NOISE PREDICTIONS AND THE NEW EUROPEAN HARMONISED PREDICTION MODEL

Roche Ireland Limited

Field experiment on ground-to-ground sound propagation from a directional source

Directivity Loss at a Duct Termination

Problems with the INM: Part 2 Atmospheric Attenuation

Roche Ireland Limited

Trials of a mobile MLS technique for characterising road surface absorption. Abstract

BASELINE NOISE MONITORING SURVEY

Black. LWECS Site Permit. Stearns County. Permit Section:

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

Measuring procedures for the environmental parameters: Acoustic comfort

Methods for rating and assessing industrial and commercial sound

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

ROOM SHAPE AND SIZE ESTIMATION USING DIRECTIONAL IMPULSE RESPONSE MEASUREMENTS

Sound level meter directional response measurement in a simulated free-field

Modeling Diffraction of an Edge Between Surfaces with Different Materials

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ACOUSTICAL COMPUTER SIMULATIONS OF THE ANCIENT ROMAN THEATRES

Muswellbrook Coal Company

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

CHAPTER ONE SOUND BASICS. Nitec in Digital Audio & Video Production Institute of Technical Education, College West

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

Appendix G Noise and Vibration Assessment

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

HIIUMAA OFFSHORE WINDFARM, ESTONIA LOW FREQUENCY NOISE AND INFRASOUND SURVEY

Noise Certification Workshop

ACTIVE LOW-FREQUENCY MODAL NOISE CANCELLA- TION FOR ROOM ACOUSTICS: AN EXPERIMENTAL STUDY

MEASURING SOUND INSULATION OF BUILDING FAÇADES: INTERFERENCE EFFECTS, AND REPRODUCIBILITY

A. INTRODUCTION B. METHODOLOGY

APPENDIX A SOUND PROPAGATION THEORY & METHODOLOGIES

Appendix N. Preliminary Noise Assessment Technical Memorandum

Revision of ISO Standards on field sound insulation testing. Carl Hopkins

City and Borough of Juneau

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Pipeline Blowdown Noise Levels

SOURCE DIRECTIVITY INFLUENCE ON MEASUREMENTS OF SPEECH PRIVACY IN OPEN PLAN AREAS Gunilla Sundin 1, Pierre Chigot 2.

Acoustic Performance of Helmholtz Resonator with Neck as Metallic Bellows

An Introduction to Digital Steering

3rd European Conference on Underwater Acoustics Heraklion, Crète GREECE June 1996

Muswellbrook Coal Company

ECMA-74. Measurement of Airborne Noise emitted by Information Technology and Telecommunications Equipment. 12 th Edition / December 2012

Real time spectrum analyser sound level meters

A BEM study of the influence of musicians on onstage sound field measures in auditoria

Psychoacoustic Cues in Room Size Perception

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report

6-channel recording/reproduction system for 3-dimensional auralization of sound fields

DESIGN AND APPLICATION OF DDS-CONTROLLED, CARDIOID LOUDSPEAKER ARRAYS

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

REVERBERATION CHAMBER FOR EMI TESTING

DESIGN OF ROOMS FOR MULTICHANNEL AUDIO MONITORING

Offaly County Council

Creating an urban street reverberation map

Broad band air ultrasound reference sound source

APPLICATIONS OF A DIGITAL AUDIO-SIGNAL PROCESSOR IN T.V. SETS

NOISE IMPACT ASSESSMENT 2016

Organisation Internationale de Métrologie Légale

Acoustic Calibration Service in Automobile Field at NIM, China

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements

Assessing the accuracy of directional real-time noise monitoring systems

A comparing overview on ECAC Doc.29 3 rd Edition and the new German AzB

Simple Feedback Structure of Active Noise Control in a Duct

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

Rec. ITU-R P RECOMMENDATION ITU-R P PROPAGATION BY DIFFRACTION. (Question ITU-R 202/3)

ANALYTICAL NOISE MODELLING OF A CENTRIFUGAL FAN VALIDATED BY EXPERIMENTAL DATA

Further Comparison of Traffic Noise Predictions Using the CadnaA and SoundPLAN Noise Prediction Models

Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations

ECMA-74. Measurement of Airborne Noise emitted by Information Technology and Telecommunications Equipment. 15 th Edition / June 2018

Sound Systems: Design and Optimization

McGill Environmental Ltd.

Reducing the influence of microphone errors on in- situ ground impedance measurements

Influence of ground reflections and loudspeaker directivity on measurements of in-situ sound absorption

SERIES K: PROTECTION AGAINST INTERFERENCE

Attended Noise Monitoring Program

Behrens & Associates Environmental Noise Control, Inc.

Pfizer Ireland Pharmaceuticals

Transcription:

A realistic environmental approach for the construction of a perceptual typology of industrial noise sources Guillaume Le Nost, Stéphanie Viollon EDF R&D, 1 av. du Général de Gaulle, 92141 Clamart Cedex, France, {guillaume.le-nost, stephanie.viollon}@edf.fr, Catherine Marquis-Favre LASH / DGCB URA CNRS 1652, ENTPE, 2 rue Maurice Audin, 69518 Vaulx-en-Velin Cedex, France, marquis@entpe.fr Industrial noise sources are various and may cause annoyance around industrial sites, especially when the installations work 24 hours a day. To better understand the environmental impact of permanent industrial sources, a first step consists in creating a perceptual typology of these sources. This typology will be used in future laboratory studies in order to assess the relative annoyance of industrial noise sources. Based on a bibliographical study, a physical classification of major industrial sources has been drawn up. A recording campaign was set up, aiming at collecting each noise source separately in the proximity of the source in order to avoid unwanted noises. Seventy sources were recorded with a stereophonic system (ORTF technique), mainly on French electricity production sites. Sound stimuli are created by filtering the recordings in order to simulate the sound attenuation between the on-site recording point and another point which would represent a dwelling located further away from the source. The filters are calculated with third octave definition by a sound propagation software, which takes into account the influence of distance, atmosphere and ground effects. For a given test-case, the constructed stimuli are compared with real recordings to confirm the choice of propagation parameters for the calculation of filters. A listening test using these stimuli is set up in laboratory conditions in order to obtain perceptual groups of sources. The audio database of industrial sources, the stimuli generation technique and the listening test protocol are presented. 1 Introduction To assess the noise impact of industrial sources, some countries (France, Australia) base their legislation standards on the concept of sound emergence. In France [1], this criterion is defined as the difference between the A-weighted equivalent sound pressure level of the ambient noise (source on) and the A- weighted equivalent sound pressure level of the residual background noise (source off). The maximum legal value for the sound emergence varies with the type of installation, the working duration and the considered period (day or night). In France, the strictest limits are 5 db(a) for the day period and 3 db(a) for the night period, whereas in Australia, the limit is 5 db(a) for day and night periods [2]. Like the sound emergence, the British standard [3] is also based on a comparison with the background noise level: the estimated A-weighted equivalent sound pressure level of a specific industrial noise should be 5 db(a) below background noise. In some cases, the French legislation standard seems inappropriate: a previous study [4] found that at a given emergence level, annoyance judgments differ according to the kind of source. If penalties accounting for acoustic features of noise (such as tonal or impulsive character) do exist, laboratory experiments show that they are not adapted to sound stimuli where acoustic features are complex, which is often the case for real industrial noises [5]. For instance, listening tests led by Berry and Porter [6] have shown that an addition of penalties corresponding to specific acoustic features cannot account for annoyance of an industrial noise with multiple acoustic features (in the case of an industrial noise with twotone complexes or an industrial noise with impulsive and tonal character). It would be thus interesting to develop improved descriptors related to perceptual categories of sources. In order to define noise annoyance criteria that would be related to categories of permanent industrial sources, a first step consists in creating a perceptual typology of these sources. The typology should classify the sources as they are perceived by people living in the neighbourhood of industrial sites. This paper describes a realistic environmental approach for the creation of sound stimuli which simulate the sound of one industrial source at a given distance of the source. Three major points are detailed: the general method, the construction of a high-quality representative audio database of separate industrial sources and background noises, the design of a filtering method for generating representative environmental sound stimuli near dwellings. 1825

2 General method Let us consider a point M representing a virtual dwelling located at a given distance (typically several hundred meters) from an industrial site. The industrial site can be represented by a set of various industrial noise sources. It is usually not possible to record directly the contribution of one source S at point M, because of the contribution of other noise sources to the ambient noise at point M. It is then necessary to record the noise of the source S at a point R located near the source itself, in order to avoid unwanted noises. The recordings are filtered to simulate the propagation effects between R and M. Figure 1 illustrates the principle. The choice of the point R must respect two antagonistic conditions which can lead to a practical compromise. Firstly, R must be located in the far-field of the source, which allows us to consider the industrial source as a point-source. Secondly, the point R should be chosen so as to minimize the influence of the environment of the source (buildings reflections, other sources ) on the recording. In far-field conditions, the sound pressure level L p (R) in a given frequency band can be written as: L p (R) = L w - A(S,R) where L w is the sound power level of the source S in the frequency band, and A(S,R) corresponds to the attenuation between S and R, due to propagation phenomena (details are given in section 4.1.). Writing the sound pressure level at the point M, L p (M), leads to : L p (M) = L p (R) + A(S,R) - A(S,M) Therefore, the chosen approach is to simulate the noise at the point M by applying a frequency filter of gain per band A(S,R)-A(S,M) to the recording at the point R. 3 Collecting audio recordings 3.1 Functional typology of industrial noise sources A bibliographical study was conducted in order to identify industrial noise sources. The reference list of sources was extracted from the Imagine Project [7], and completed using references concerning industrial noise [8, 9, 10, 11]. The resulting typology is given in Table 1. Note that all indoor sources have been gathered in one category machinery halls, considering the sources enclosure as a whole. Table 1: Functional typology of industrial noise sources Categories combustion devices electrical machinery liquid flow devices gas flow mechanical devices machinery halls material extraction / handling Details furnaces, flares, internal combustion engines transformers, alternators, motors, high voltage wires cooling towers, mixing tanks, pumps fans, valves, blowers, gas jets, exhaust stacks, compressors, piping, turbines, wind turbines indoor sources located in a same enclosure conveyors and other devices A(S,R) and A(S,M) are calculated with third octave definition by a sound propagation software. S S R one unwanted one recording point near the source industrial noises industrial source source filter simulating propagation M M recording point it is impossible to isolate S from other noises Figure 1: general method for simulating the noise of an industrial source S at a point M, located several hundred meters away from the source. receiver point, close to dwellings P(M) is the simulated contribution of S 1826

3.2 Recording protocol A stereophonic system (ORTF technique) was used in order to get realistic recordings. Sound level at the recording point was measured in the same time by a sound level meter. The recording point R was located in the vicinity of the source, considering the following points : R is close to the source, so as to avoid noise from other sources, R is located in the far-field of the source, i.e. at a distance d > max (3l, 3λ, 3l²/λ) if l is the characteristic dimension of the source and λ its emitted acoustic wavelength, distances between the microphones and any building are at least 2 m [1], the microphones are positioned at 1.2 m above the ground. When possible, the ground is chosen of lesser flow resistivity (for example, grass will be preferred to asphalt). For noise sources with non uniform directivity pattern, relative position of point R was chosen along the radius corresponding to the maximal measured equivalent sound level. Dimensions of the source, height of the source, distances between source and point R were measured. The ground was classified into basic flow resistivity categories (grass, gravel, asphalt), the resistivity value was chosen according to material database. A picture of the source was taken on-site. 3.3 The audio database Seventy industrial noises were recorded, covering all categories listed in Table 1. Far-field conditions were well respected except for cooling towers (because of their dimensions). A database has been set-up, containing the audio recordings and all information relative to the source and the measure itself. The database also contains a dozen background noises, corresponding to typical locations of an industrial site during the night or the day. Categories are listed in Table 2. Table 2: categories of background noises Categories quiet area in open country major road water Details area undisturbed by noise coming from road traffic or from industrial and recreational activities national roads and highways area near a river, a lake or the sea 4 Simulating outdoor sound propagation As explained in section 2, sound propagation between points R and M is simulated by filtering the audio signals recorded at point R. Amplitude of the filters depends on the attenuations A(S,R) and A(S,M), which are calculated by a sound propagation software developed by EDF R&D and merely based on ISO 9613-2 [12]. 4.1 Phenomena and models The calculation of A(S,R) and A(S,M) accounts for the following propagation mechanisms: geometrical divergence, atmospheric attenuation, downward refraction conditions, ground effect, reflections of buildings near the source (for A(S,R) only). Geometrical divergence corresponds to a sound level decay of 6 db per doubling of distance from a point source. Atmospheric attenuation is calculated according to ISO 9613-2 [12]. Ground effect is represented by reflection of the acoustic waves on a plane surface with finite impedance, assuming Delany and Bazley complex impedance model [13]. Downward refraction conditions are simulated by adding ground reflections according to ISO 9613-2 method [12]. Reflections on buildings are calculated using an image-source method. Sources are modeled as omnidirectional point sources. Cooling towers were not recorded with far-field conditions (see section 3.3.) and will be modeled as extended sources. 1827

Therefore, the simulated attenuations A(S,R) and A(S,M) depend of the following parameters: geometry of the model {source, ground, R, M}, summation of the direct and reflected waves in pressure (interferences) or in energy (no interferences), vicinity of buildings (and their façade absorption coefficient), ground resistivity, measured with third octave definition by sound intensity technique. In the idea of testing the filters types for different propagation environments between S and R, additional recordings are performed: one case with gravel-type ground, and another case with a building located at a distance of behind the source. Configurations are detailed in Table 3. Table 3: measurement configurations position of the added ground reflections for A(S,M) (downward refraction conditions). Name Source height Distance Source - microphones Ground / buildings 4.2 Filter design For every third-octave band from center frequency f C =16 Hz to 16000 Hz, a gain G = [A(S,M) - A(S,R)] is calculated. A linear phase Finite Impulse Response filter is designed by inverse FFT of a narrow band interpolation of the (f C,G) values. Audio recording at point R is convoluted by this FIR filter to constitute a sound stimulus at point M. (S,R 1 ) (S,R 2 ) (S,R 3 ) (S,M) 12m 12 m 12 m 100 m gravel & building at behind source S 4.3 A test-case for optimal choice of calculation parameters In order to get an optimal choice of the parameters detailed in section 4.1, filtered audio recordings at point R are compared with reference noises (resulting from measurements at point M) for a propagation testcase above plane ground, using a reference sound source. Several filters types are designed to study the perceptual influence of the following calculation parameters : calculation mode for A(S,R): with or without interferences, calculation mode for A(S,M): with or without interferences, value of the parameter which determines the position of the added ground reflections (downward refraction conditions) for the calculation of A(S,M), ground resistivity value. For the field measurements, a loudspeaker (B&K 4296) is placed at a height h S on a flat, grassy terrain. At a distance of d=12 m (point R) and 100 m (point M) of the source, the stereophonic recording system and a sound level meter are positioned at a height of 1.2 m. Audio recordings and third-octave sound levels measurements are performed for two noises (pink noise, transformer noise) and two values of h S ( and ). The acoustic power level of the source is also For each point R (R1, R2 and R3), each source height (1.5 and ) and each noise (pink noise, transformer noise), the corresponding filters are calculated and applied to the audio recordings at point R to constitute sound stimuli. In order to choose the optimal filter type, these sound stimuli are compared to the reference noises, using both a physical approach (spectral analysis) and a perceptual approach (listening test). Results and analysis of the physical and perceptual comparisons will be presented at the conference. 5 Perspectives The sound stimuli created with optimised filters will be used in future listening tests (categorization tasks) in order to obtain perceptual groups of industrial sources. For each perceptual group, industrial noises will then be mixed with various background noises to assess noise annoyance with the sound emergence criterion. References [1] AFNOR, Acoustique : Caractérisation et mesurage des bruits de l environnement, NF S 31-010. Paris : AFNOR, 1996, 48p. [2] Environment Protection Authority, NSW Industrial Noise Policy, EPA 00/1. Sydney : EPA, 1828

2000, 62p. Available at: www.epa.nsw.gov.au/ publications/epa/noise.htm [3] British Standard Institution, Method for rating industrial noise affecting mixed residential and industrial areas, BS 4142:1997. [4] S. Viollon, C. Marquis-Favre, F. Junker & C. Baumann, Environmental assessment of industrial noises annoyance with the criterion sound emergence, Proc. 18th ICA, Kyoto, Japan, 2004. [5] B.F. Berry & N.D. Porter, Review and analysis of published research into the adverse effects of industrial noise, in support of the revision of planning guidance, DEFRA report n NANR5. London: DEFRA Publications, 2004, 91p. Available at: www.defra.gov.uk/environment/ noise/industrial/index.htm [6] B.F. Berry & N.D. Porter, The evaluation of acoustic features in industrial noise, Proc. Internoise 1994, Yokohama, Japan, vol. 2, pp. 803-808. [7] Imagine project website: www.imagine-project.org [8] R.F. Barron, Industrial noise control and acoustics, New York : Marcel Dekker Inc., 2003, pp. 164-206. [9] L.W. Bell & D.-H. Bell, Industrial noise control Fundamentals and applications, New York : Marcel Dekker Inc., 1994, chapter 13. [10] E.P. Bergmann, Severe sources of industrial machinery noise : task report, Washington : National technical information service, 1974, n 271930. [11] S.J. Stephenson & B.C. Postlethwaite, Final report on Defra Research Project : noise mapping industrial sources, Technical report AT5414/2 rev1. London : DEFRA, 2003, 232 p. [12] ISO, Acoustics: Attenuation of sound during propagation outdoors - part 2 : general method of calculation, ISO 9613-2 1996. Genève : ISO, 1996, 18 p. [13] M. Delany & E. Bazley, Acoustical properties of fibrous absorbent materials, Applied Acoustics, Vol. 3, 1970, pp.105-116. 1829